• 제목/요약/키워드: Test field

검색결과 9,479건 처리시간 0.043초

시험도로 건설과 계측시스템 구축 (A Review of Instrumentation System and Construction of Korea Highway Test Road)

  • 최준성;김도형;김성환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.603-606
    • /
    • 2000
  • The cost needed for the construction and management of highways in the whole nation is rapidly growing so the research that can decrease the cost is required. However, most of the highway specs have simply converted from those of other countries, including USA. Therefore, some of our design and construction specs were not the optimum ones based on our own situation, requiring a research under the actual traffic and environment of our nation. The use of test road develops many aspects of highway engineering. Those are evaluation of construction materials, a general overview of korea pavement design and serviceability under the actual traffic and environmental condition of the nation. It is also economical and efficient compared to the trial construction of each item in spreaded form. A test road, 7.7km long with two lanes, is being constructed on the Inner Central Expressway. In this test road, 2.7km is planned for asphalt pavement and 3.4km is planned for concrete pavement. Three test bridges and five earth retaining structures will be included in the test road. Based on the master plan, the major performance was progressing such as detailed research modules of each area, preliminary research for the future research, sensor surveys for the behavior analyses of pavements and structures with installation methods and data acquisition systems, the foundation research of Integrated Instrumentation System and the Management Plan for automated measurement. Some area(structure research division, geotechnical research division) was designed the instrumentation plan because some instrument sensors must be installed during the construction of the test road. And then the instrumentation plan of each area was enforcing because a large majority of the instrument sensors must be installed after the construction of the test road. The field surveys with material property tests and pilot instrumentation test with sensor tests was also performing in accordance with the construction in the field.

  • PDF

현장직접전단시험기의 개발 및 현장적용에 관한 연구 (Development of an In Situ Direct Shear Test Apparatus and Its Field Application)

  • 김용필;이영균;이성국;엄정기
    • 터널과지하공간
    • /
    • 제21권3호
    • /
    • pp.181-191
    • /
    • 2011
  • 단층대, 파쇄대 또는 풍화대가 발달한 암반은 실내시험을 위한 시료 성형이 어렵다. 기존에 현장에서 수행된 직접전단시험은 갱도 내벽의 수직반력을 이용하여 수행되었다. 이 연구에서 개발된 현장직접전단시험기는 터널내부 또는 노천의 현장상태 암반에서 시험을 수행할 수 있다. 현장직접전단시험기의 주요 구성은 전단하중 반력판 및 하중전달판, 유압실린더 시스템, 로드셀, 다단계 전단상자, 전단상자 고정장치, 수직하중 반력판 및 하중전달판, 마찰저항 감소용 롤러 등이다. 공시체는 각주형의 블록으로 최대 크기는 $400{\times}400{\times}460$ mm이며 현장에서 형성하는 방법 및 절차가 제시되었다. 개발된 시험기의 현장적용성 평가를 위하여 연구지역에 대한 지질공학적 조사 분석 연구를 통하여 성능시험을 위한 공시체 형성에 적합한 위치가 선정되었다. 현장적용 결과 개발된 현장용 시험기는 암석의 강도 및 변형과 관련하여 필요한 대부분의 정보를 제공할 수 있는 성능을 확보하였음을 확인하였다.

여름철 농민의 서열 부담 경감을 위한 냉각조끼의 성능 평가 (Efficacy of Cooling Vests for Alleviating Heat Strain of Farm Workers in Summer)

  • 최정화;김명주;이주영
    • 한국의류학회지
    • /
    • 제29권8호
    • /
    • pp.1176-1187
    • /
    • 2005
  • The purpose of this study was to evaluate the efficiency of cooling vests developed for farm workers harvesting red pepper in summer. The study was performed using the following two steps: 1) Climatic chamber test, 2) Field test. For the chamber test, a work environment was simulated as $33^{\circ}C$ and $65\%$RH, and the thermo-physiological and subjective responses were measured with and without cooling vests. Twelve young males participated as subjects. For the field test, three farmers participated while harvesting red pepper on the form, in summer. The measurements used were same as in the chamber test. Subjects were tested without any cooling vests, as a control. They were tested wearing vests with 2 frozen gel packs (CV2: Cooling area, $308cm^2$), and vests with 4 frozen gel packs (CV4: Sooting area, $616cm^2$). As a result of the chamber test, rectal temperature($T_{re}$) and mean skin temperature( $T_{sk}$) were lower in both CVs than in Control, and this tendency was statistically significant in CV4 (p<.05). Clothing microclimate temperature ($T_{clo}$) and total sweat rate (TSR) were significantly lower when wearing cooling vests (p<.05) Heart rate (HR) was also lower in wearing cooling vests than in Control, and the speed of recovery to the comfort level was faster when the subjects wore cooling vests. In addition, subjects felt 'less hot, less humid, and less uncomfortable' in both CVs than in Control. Field tests showed a similar tendency with the chamber tests. In particular, wearing the cooling vest was effective in restraining the raise of $T_{clo}$ on the back. It can be concluded that the cooling vest was effective in alleviating heat strain and discomfort in both the chamber test and the field test, despite the cooling area of the cooling vest being just $3.4\%$ of the body surface area ($616cm^2$).

Students' Field-dependency and Their Mathematical Performance based on Bloom's Cognitive Levels

  • Alamolhodaei, Hassan;Hedayat Panah, Ahmad;Radmehr, Farzad
    • 한국수학교육학회지시리즈D:수학교육연구
    • /
    • 제15권4호
    • /
    • pp.373-386
    • /
    • 2011
  • Students approach mathematical problem solving in fundamentally different ways, particularly problems requiring conceptual understanding and complicated strategies. The main objective of this study is to compare students' performance with different thinking styles (Field-dependent vs. Field independent) in mathematical problem solving. A sample of 242 high school males and females (17-18 years old) were tested based on the Witkin's cognitive style (Group Embedded Figure Test) and by a math exam designed in accordance with Bloom's Taxonomy of cognitive level. The results obtained indicated that the effect of field dependency on student's mathematical performance was significant. Moreover, field-independent (FI) students showed more effective performance than field-dependent (FD) ones in math tasks. Male students with FI styles achieved higher results compared to female students with FD cognitive style. Moreover, FI students experienced few difficulties than FD students in Bloom's Cognitive Levels. The implications of these results emphasize that cognitive predictor variables (FI vs. FD) could be challenging and rather distinctive factor for students' achievement.

고온초전도 Homopolar 전동기용 계자코일의 설계 및 특성평가 (Design and Test of HTS Homopolar Motor Field coil)

  • 이재득;이상호;김호민;이언용;백승규;권영길;홍정표;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.784-785
    • /
    • 2008
  • In general, in most case of high temperature superconducting (HTS) rotating machinery, HTS field coil is rotated. HTS homopolar motor field coil is nat necessary to be rotated and the torque of motor is not strongly related with the field coil. Therefore, HTS homopolar motor has a superior mechanical stability comparing with other HTS rotating machines. These advantages can make the design of HTS field coil and cryostat much more simple. In this paper, HTS field coil was fabricated and tested. Before test, authors habe estimated the critical current of HTS field coil at 77K by simulation using FEA (Finite Element Analysis) software and power law equation. The experiment details and results are presented in this paper, and discussed. The field windings are made with HTS Bi-2223 wire which operates at 77K.

  • PDF

지구자기장 기반 실내측위기술의 건설현장 적용 가능성 검토 (A Review on the Applicability of Geomagnetic Field-Based Indoor Positioning in Construction Site)

  • 김현민;이창우;김형준;이창수;임바다;조훈희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.123-124
    • /
    • 2023
  • Despite the acuuracy, stability, and economic feasibility of geomagnetic field-based indoor positioning, its applicability in construction sites needs to be thoroughly discussed due to the issue of distortion of geomagnetic fields around ferromagnetic objects such as rebars. In this study, the possibility of applying the geomagnetic field-based indoor positioning in construction sites was reviewed through the Student's t-test after measuring the changes in geomagnetic field values depending on the presence or absence of rebars. The statistical analysis revealed that there is a high probability (over 80%) of significant changes in geomagnetic field values when measuring points are located within 60cm from the rebars. On the other hand, the probability of minimal changes in geomagnetic field values is over 90% when measuring points are located more than 60cm from the rebars. This suggests the application of geomagnetic-based indoor positioning in construction sites would be possible if the issue of distortion in geomagnetic field values near rebars within 60cm is resolved.

  • PDF

자기장 영향에 따른 자기유변탄성체의 구름 마찰 특성 연구 (A Study on Rolling Friction Characteristics of Magneto-Rheological Elastomer under Magnetic Fields)

  • 연성룡;이광희;김철현;이철희
    • Tribology and Lubricants
    • /
    • 제30권4호
    • /
    • pp.234-239
    • /
    • 2014
  • Magneto-rheological elastomer (MR elastomer) is a smart material, because it has mechanical properties that change under a magnetic field. An MR elastomer changes its stiffness characteristics when the inner particles (iron particles) align along the direction of a magnetic field. There has been much research to make use of this characteristic to control vibration issues in various mechanical systems, such as for mounting systems in the automotive field, home appliances, etc. Furthermore, the friction and wear properties of MR elastomer have been studied, as these relate to the durability of the material needed to meet engineering requirements. Rolling friction (or rolling resistance) is one of these friction properties, but has not yet been studied in the context of MR elastomers. In this study, an MR elastomer is fabricated in the shape of a hollow cylinder to evaluate the rolling friction characteristic under a magnetic field. The test apparatus is setup and a strain gauge is used to calculate the rolling resistance under test conditions. Permanent magnets are used to supply the magnetic field during tests. The load and rolling speed conditions are also considered for the tests. The test results show that rolling friction characteristic has a different trend under different magnetic field, load, and rolling speed conditions. It is assumed that the stiffness change of an MR elastomer under a magnetic field has an effect on the rolling friction characteristic of the MR elastomer. For the future work, the rolling friction characteristics of MR elastomers will be controlled by adjusting the strength of the magnetic field using electromagnets.

다짐밀도 측정장비(Non-nuclear Type)를 사용한 현장 다짐밀도 평가 (Evaluation of Field Compaction Density by Non-nuclear Density Gauge)

  • 김영민;임정혁;양성린;김기현;황성도;정규동
    • 한국도로학회논문집
    • /
    • 제17권1호
    • /
    • pp.51-58
    • /
    • 2015
  • PURPOSES : The objective of this study is to compare the densities of asphalt pavements measured both in the field and in the laboratory, and also to evaluate the applicability of field density measuring equipment, such as the pavement quality indicator (PQI), by using statistical analysis. METHODS : For the statistical analysis of the density measured from asphalt pavement, student t-tests and a coefficient of correlation are investigated. In order to compare the measured densities, two test sections are prepared, with a base layer and an intermediate layer constructed. Each test section consists of 9 smaller sections. During construction, the field densities are measured for both layers (base and intermediate) in each section. Core samples are extracted from similar regions in each section, and moved to the laboratory for density measurements. All the measured densities from both the field and laboratory observations are analyzed using the selected statistical analysis methods. RESULTS AND CONCLUSION : Based on an analysis of measured densities, analysis using a correlation coefficient is found to be more accurate than analysis using a student t-test. The correlation coefficient (R) between the field density and the core density is found to be very low with a confidence interval less than 0.5. This may be the result of inappropriate calibration of the measuring equipment. Additionally, the correlation coefficient for the base layer is higher than for the intermediate layer. Finally, we observe that prior to using the density measuring equipment in the field, a calibration process should be performed to ensure the reliability of measured field densities.

양산지역 점토의 비배수 전단강도 특성 (Characteristics of Undrained Shear Strength of Yangsan Clay)

  • 김길수;임형덕;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 연약지반처리위원회 학술세미나
    • /
    • pp.71-78
    • /
    • 2000
  • SHANSEP method involves the consolidation to stresses in excess of the preconsolidation pressure in order to overcome sample disturbance effect. The concept of SHANSEP is based on an approach to laboratory test which attempts to reproduce the in-situ conditions more closely than is possible in routine tests and evaluates normalized strength parameters for the soil as a function of OCR. But SHANSEP method can be applied only to fairly uniform clay deposits, and is unsuitable for a random deposit. In this study, CK/sub o/U triaxial compression test and incremental loading consolidation test were performed for the application of SHANSEP method on Yangsan clay. During the K/sub o/-consolidation, triaxial specimens were consolidated to stress equal to two times the in-situ vertical effective stress. And for overconsolidated condition, the specimens were swelled to a known vertical effective stress in order to have the desired OCR. With the results of CK/sub o/U triaxial compression test using the block samples, the relationship between c/sub u//σ/sub vc/' and OCR on Yangsan clay was established. For evaluating the undrained shear strength of Yangsan clay with depth, CK/sub o/U triaxial compression test was performed using the piston samples taken from Yangsan site. And also undrained shear strength was analyzed from the in-situ test such as Cone Penetration Test(CPT), Dilatometer Test(DMT), and Field Vane Test(FVT) and was compared with that of CK/sub o/U triaxial compression test.

  • PDF