• Title/Summary/Keyword: Test evaluation

Search Result 15,308, Processing Time 0.054 seconds

Mechanical Property Evaluation of Dielectric Thin Films for Flexible Displays using Organic Nano-Support-Layer (유기 나노 보강층을 활용한 유연 디스플레이용 절연막의 기계적 물성 평가)

  • Oh, Seung Jin;Ma, Boo Soo;Yang, Chanhee;Song, Myoung;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.33-38
    • /
    • 2021
  • Recently, rollable and foldable displays are attracting great attention in the flexible display market due to their excellent form factor. To predict and prevent the mechanical failure of the display panels, it is essential to accurately understand the mechanical properties of brittle SiNx thin films, which have been used as an insulating film in flexible displays. In this study, tensile properties of the ~130 nm- and ~320 nm-thick SiNx thin films were successfully measured by coating a ~190 nm-thick organic nano-support-layer (PMMA, PS, P3HT) on the fragile SiNx thin films and stretching the films as a bilayer state. Young's modulus values of the ~130 nm and ~320 nm SiNx thin films fabricated through the controlled chamber pressure and deposition power (A: 1250 mTorr, 450 W/B: 1000 mTorr, 600 W/C: 750 mTorr, 700 W) were calculated as A: 76.6±3.5, B: 85.8±4.6, C: 117.4±6.5 GPa and A: 100.1±12.9, B: 117.9±9.7, C: 159.6 GPa, respectively. As a result, Young's modulus of ~320 nm SiNx thin films fabricated through the same deposition condition increased compared to the ~130 nm SiNx thin films. The tensile testing method using the organic nano-support-layer was effective in the precise measurement of the mechanical properties of the brittle thin films. The method developed in this study can contribute to the robust design of the rollable and foldable displays by enabling quantitative measurement of mechanical properties of fragile thin films for flexible displays.

Assessment of Productivity and Vulnerability of Climate Impacts of Forage Corn (Kwangpyeongok) Due to Climate Change in Central Korea (국내 중부지역에 있어서 기후변화에 따른 사료용 옥수수의 생산성 및 기후영향취약성 평가)

  • Chung, Sang Uk;Sung, Si Heung;Zhang, Qi-Man;Jung, Jeong Sung;Oh, Mirae;Yun, Yeong Sik;Seong, Hye Jin;Moon, Sang Ho
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.39 no.2
    • /
    • pp.105-113
    • /
    • 2019
  • A two-year study was conducted from 2017 to 2018 by the establishment of a test field at Chungju-si and Cheongyang-gun. Plant height, number of leaves, insects and diseases, and fresh and dry matter yields for corn hybrid('Kwangpyeongok') were investigated. Daily average, maximum, and minimum temperature, monthly average temperature, daily precipitation, and sunshine duration during the growing season were investigated. We selected climate-critical factors to corn productivity and conducted an evaluation of vulnerability to climate change from 1999 to 2018 for both regions. In 2018, the dry matter yield of forage corn was 6,475 and 7,511 kg/ha in Chungju and Cheongyang, respectively, which was half of that in 2017. The high temperature and drought phenomenon in the 2018 summer caused the corn yield to be low. As well as temperature, precipitation is an important climatic factor in corn production. As a result of climate impact vulnerability assessment, the vulnerability has increased recently compared to the past. It is anticipated that if the high temperature phenomenon and drought caused by climate change continues, a damage in corn production will occur.

Comparison of Productivity and Feed Value at Different Harvest Stages and Seeding Methods of Bermudagrass and Bahiagrass Cultivars (Bermudagrass와 Bahiagrass의 품종별 수확시기 및 파종방법에 따른 생산성 및 사료가치 비교)

  • Lee, Wang Shik;Im, Suk Ju;Kim, Bum Jun;Kim, Young Jin;Kim, Dong Hoon;Hwang, Kyung Jun;Kim, Si Hyun;Woo, Jae Hoon;Park, Nam Geon
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.38 no.4
    • /
    • pp.310-319
    • /
    • 2018
  • The southern type grasses announced for the test were the Bermudagrass cultivars (Giant, Cheyenne, Mohawk, Panchero Frio, Common and Tifton 85) and the Bahiagrass cultivars (TifQuik, Tifton 9), and the changes in the productivity and nutrient content were surveyed in Jeju area (450m altitude). The different cultivars were sowed by broadcasting or drill seeding method, and Tifton 85 was transplanted from sprigs. The fresh and dry matter yield showed varying significant differences for different cultivars (p<0.05). The fresh yields of Tifton 85, TifQuik and Tifton 9 were excellent, compared to the other cultivars, and for the dry matter yield, Tifton 85 and Tifton 9 were excellent when compared to the other cultivars. Crude protein content showed significant differences among different cultivars (p<0.05). Cheyenne, Mohawk, Panchero Frio, and Common showed differences in the crude protein content by sowing method and harvest time (p<0.05). The different cultivars showed differences in the crude fiber content (p<0.05), and Tifton 9 registered significantly high content and Mohawk and Tifton 85 showed significant crude fiber content by harvest time (p<0.05). According to these results, the southern type grass cultivars showed big differences in the regenerative capacity against damage from frost, productivity, and nutrient content, so they need to be chosen according to the purposes, and to increase their usage, their evaluation needs to be conducted at various altitudes.

The influence of the decision making time by using point-of-care creatinine in patients with acute abdomen (급성 복증 환자에서 현장검사 크레아티닌을 이용한 의사결정 시간의 단축)

  • Choi, Younhyuk;Cho, Sunguk;Ahn, Hongjoon;Min, Jinhong;Jeong, Wonjoon;Ryu, Seung;Oh, Segwang;Kim, Seunghwan;You, Yeonho;Lee, Jinwoong;Park, Jungsoo;Yoo, Insool;Cho, Yongchul
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.663-670
    • /
    • 2018
  • Objective: Radio-contrast abdomino-pelvic computed tomography (APCT) is considered the gold standard diagnostic tool for an acute abdomen in the emergency department. On the other hand, APCT has a risk of contrast-induced nephropathy. Emergency physicians evaluate the creatinine (Cr) level prior to taking a APCT for the above reason but it takes time to evaluation the serum Cr level. This study hypothesized that Cr measured by a point-of-care test (POCT) can shorten the time to making clinically important decisions for patients with an acute abdomen. Methods: This prospective randomized study was conducted between March 2017 and October 2017. The subjects were divided into two groups (Cr measured by laboratory vs. Cr measured by POCT). To analyze the clinical acceptability for creatinine, agreement was demonstrated graphically by Bland-Altman plots. This study compared the time to make a clinically important decision by physicians and the length of stay at the emergency department in both groups. Results: A total of 76 patients were eligible for the study, 38 patients were assigned to each group. There was no statistically significant difference in the time to the first medical examination (P=0.222) and emergency department stay time (P=0.802). On the other hand, the time to recognition of the Cr level (P<0.001), time to performing APCT (P<0.001), time to decision making (P<0.001), and time to initiation of treatment (P<0.001) were shortened significantly in the point-of-care creatinine group. Conclusion: In this study, the POCT for creatinine can allow rapid decision making by shortening the time to performing the radio-contrast APCT than the laboratory for patients with an acute abdomen.

Preservative Efficacies according to the Composition of 1, 3-Butylene Glycol and Alkane Diols in Cosmetics (화장품에서 1,3-부틸렌 글라이콜 및 알칸디올계 조성에 따른 방부력에 관한 연구)

  • Suh, Ji Young;Yun, Mid Eum;Lee, Ye Seul;Xuan, Song Hua;Park, Dong Soon;Park, Soo Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.44 no.4
    • /
    • pp.363-373
    • /
    • 2018
  • In recent years, parabens used as preservatives in cosmetics have become a problem of human safety. Therefore, in this study, we tried to evaluate the preservative efficacy of 1,3-butylene glycol, 1,2-hexanediol, and 1,2-pentanediol as a preservative system to replace parabens. 1,3-Butylene glycol was added to cosmetic creams at a concentration of between 5 and 25%. The preservative efficacy of 1,3-butylene glycol was determined using a M-3 challenge test, as recommended by the Personal Care Products Council (formally CTFA). The alkane diols, such as 1,2-hexanediol and 1,2-pentanediol, were assessed in a similar manner. An evaluation of the preservative efficacy of 1,3-butylene glycol revealed that it was effective against all tested microbial strains at a concentration of 25%. We also investigated the efficacy of combinations of 0.3% phenoxyethanol and 0.1% ethylhexylglycerin. Finally, we tested the alkane diols, including 1,2-hexanediol and 1,2-pentanediol, as an alternative to the preservative 0.3% phenoxyethanol. Both 1% 1,2-hexanediol and 1% 1,2-pentanediol demonstrated preservative efficacy. Taken together, our study demonstrated that the formulation of 25% 1,3-butylene glycol and 0.1% ethylhexylglycerin, 1% 1,2-hexanediol, and 1% 1,2-pentanediol had the best preservative efficacy of the compositions tested. Thus, this study suggests that the formulation is a possibility of substituting parabens preservatives, which has been used in cosmetics and has become a safety issue.

Evaluation of the influence of a visual design of an examination guide on patient comprehension and testing accuracy (검사 안내문의 시각적 디자인화가 환자의 검사 이해도 및 정확성에 미치는 영향 평가)

  • Kang, Young-Eun;Jung, Woo-Young;Hong, Bo-Ruem
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • Purpose An examination guide is a useful medium to provide the patient with an overview, pre- and post-test preparation, and precautions of nuclear testing. The design and arrangement of existing written texts and announcements were evaluated to elucidate the comprehension of patients undergoing testing. Materials and Methods Informational material describing bone scanning and $^{201}thallium$ myocardium perfusion single-photon emission computed tomography (SPECT), as a secondary examination, which accounts for the largest portion of gamma imaging at Asan Hospital (Seoul, South Korea), was selected as an improvement target in consultation with a national innovation center. Existing informational material was dispensed to patients scheduled for bone scans from November 2016 to February 2017 and the revised material was issued from March 2017 to May 2017. A survey was conducted of 200 patients who underwent $^{201}thallium$ myocardium perfusion SPECT before and after the revisions (n = 100 each time period) to assess the patients' understanding of the informational material. Results When comparing the use of the conventional vs. revised material, the number of patients who received treatment before bone scanning had decreased from 130 to 60, while the number of those who required additional imaging decreased from 53 to 14. Prior to the revision, 43% of patients underwent testing before preparation and 18% underwent additional testing. The decreased need for additional image acquisition after revision of the informational material resulted in a decrease in acquisition time of about 2 min, from 16.5 to 14.2 min. In the case of $^{201}thallium$ myocardium perfusion SPECT, patient comprehension of all five items surveyed had increased, while the number of patients who had repeatedly asked about various facets of the procedure pre- and post-testing had decreased from 36% to 16% and 31% to 14%, respectively. Conclusion Lower patient comprehension is accompanied by a decrease in image quality due to non-compliance during pre-testing and may lead to repetitive questions from the patient, which may also negatively affect the fatigue and work efficiency of the examiner. Improved readability and visibility of informational material through visualization was correlated with greater patient comprehension as well as improved image quality and acquisition time.

Performance Evaluation of Reconstruction Algorithms for DMIDR (DMIDR 장치의 재구성 알고리즘 별 성능 평가)

  • Kwak, In-Suk;Lee, Hyuk;Moon, Seung-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose DMIDR(Discovery Molecular Imaging Digital Ready, General Electric Healthcare, USA) is a PET/CT scanner designed to allow application of PSF(Point Spread Function), TOF(Time of Flight) and Q.Clear algorithm. Especially, Q.Clear is a reconstruction algorithm which can overcome the limitation of OSEM(Ordered Subset Expectation Maximization) and reduce the image noise based on voxel unit. The aim of this paper is to evaluate the performance of reconstruction algorithms and optimize the algorithm combination to improve the accurate SUV(Standardized Uptake Value) measurement and lesion detectability. Materials and Methods PET phantom was filled with $^{18}F-FDG$ radioactivity concentration ratio of hot to background was in a ratio of 2:1, 4:1 and 8:1. Scan was performed using the NEMA protocols. Scan data was reconstructed using combination of (1)VPFX(VUE point FX(TOF)), (2)VPHD-S(VUE Point HD+PSF), (3)VPFX-S (TOF+PSF), (4)QCHD-S-400((VUE Point HD+Q.Clear(${\beta}-strength$ 400)+PSF), (5)QCFX-S-400(TOF +Q.Clear(${\beta}-strength$ 400)+PSF), (6)QCHD-S-50(VUE Point HD+Q.Clear(${\beta}-strength$ 50)+PSF) and (7)QCFX-S-50(TOF+Q.Clear(${\beta}-strength$ 50)+PSF). CR(Contrast Recovery) and BV(Background Variability) were compared. Also, SNR(Signal to Noise Ratio) and RC(Recovery Coefficient) of counts and SUV were compared respectively. Results VPFX-S showed the highest CR value in sphere size of 10 and 13 mm, and QCFX-S-50 showed the highest value in spheres greater than 17 mm. In comparison of BV and SNR, QCFX-S-400 and QCHD-S-400 showed good results. The results of SUV measurement were proportional to the H/B ratio. RC for SUV is in inverse proportion to the H/B ratio and QCFX-S-50 showed highest value. In addition, reconstruction algorithm of Q.Clear using 400 of ${\beta}-strength$ showed lower value. Conclusion When higher ${\beta}-strength$ was applied Q.Clear showed better image quality by reducing the noise. On the contrary, lower ${\beta}-strength$ was applied Q.Clear showed that sharpness increase and PVE(Partial Volume Effect) decrease, so it is possible to measure SUV based on high RC comparing to conventional reconstruction conditions. An appropriate choice of these reconstruction algorithm can improve the accuracy and lesion detectability. In this reason, it is necessary to optimize the algorithm parameter according to the purpose.

Swimming Performance Evaluation of Four Freshwater Fish Species from the South Korea (국내에 서식하는 담수어류 4종에 대한 유영능력 평가)

  • Misheel, Bold;Kim, Kyu-Jin;Min, Kun-Woo;Jang, Min-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.2
    • /
    • pp.118-125
    • /
    • 2019
  • Swimming performance of fish is an important factor in the survival of fish. Also, swimming performance of fish is used in the form of habitat, or as a condition to consider when creating a fish ladder. However in Korea, researches in swimming performance of Korean freshwater fish were scarce and inadequate in some part, thus fish ladders were installed without considering their swimming performance. Therefore, in this study, we measured swimming performance of 4 Korean freshwater fish species to consider importance of swimming performance test. The fish used in this study were Carassius auratus, Zacco koreanus, Gnathopogon strigatus, Acheilognathus lanceolata intermedia species which was collected during October to November, 2018 at Geum River, and measurement for swimming speed of each fish was done by using $Loligo^{(R)}$ System, swim tunnel respirometer in January to February of 2019. The average value of the burst critical swimming speed ($U_{crit}$) for each species was $0.8{\pm}0.04m\;s^{-1}$ for C. auratus, $0.77{\pm}0.04m\;s^{-1}$ for Z. koreanus, $0.95{\pm}0.04m\;s^{-1}$ for G. strigatus, $0.73{\pm}0.03m\;s^{-1}$ for A. lanceolata intermedia and the average value of prolonged critical swimming speed was $0.54m\;s^{-1}$ for C. auratus, $0.67m\;s^{-1}$ for Z. koreanus, $0.7m\;s^{-1}$ for G. strigatus, $0.54m\;s^{-1}$ for A. lanceolata intermedia. Since the fish used in this experiment were collected from a small part of the water system in Korea and there were only 4 species, they were not enough to represent the species that inhabit the entire Korean water system. It will be necessary to continue evaluating the swimming performance of other freshwater species in Korea.

Evaluation of Composting Characteristics According to the Air Supply Change in Farm-Sized Swine Manure (농가규모 양돈분뇨 퇴비화시 공기공급량 변화에 따른 퇴비 특성 평가)

  • Lee, Sunghyoun;Jeong, Gwanghwa;Lee, Dongjun;Lee, Donghyeon;Jang, Yuna;Kwag, Junghoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.3
    • /
    • pp.49-61
    • /
    • 2019
  • Swine manure has been recognized as a organic sources for composting and many research was conducted to efficiently utilize and treat. This study was to evaluate a feasibility for producing swine manure compost under various treatment with mixture of swine manure and saw dust. Treatments were designed as follows; non aerated composting pile(REF), aerated composting pile of $100L/m^3$(EXP1), and aerated composting pile of $150L/m^3$(EXP2). The total days of fermentation were 28 days and each samples were collected at every 7 days from starting of composting. Temperature sensors were installed under 30~40cm from the surface of composting pile. Inner temperature in composting piles of EXP1 and EXP2 was rapidly increased to $67{\sim}75^{\circ}C$ within 1~2 days. The elevated temperatures found during the thermophilic phase are essential for rapid degradation of organic materials. While swine manure composted, moisture content, total nitrogen, EC of EXP1, EXP2 in sample at 28 days were lower than those of REF. But, pH and organic matter of EXP1, EXP2 in sample at 28 days were higher than those of REF. After finishing fermentation experiment, maturity was evaluated with germination test. Calculated germination index(GI) at REF, EXP1 and EXP2 were 23.49, 68.50 and 51.81, respectively. The values of germination index were higher at EXP1 and EXP2 which is aerated composting piles than REF which is non aerated composting pile. According to the results, composting process by aerated static pile compost had significant effect on the reduction of required period for composting. Supplying adequate amount of air to compost swine manure will greatly reduce composting period.

Development and Effect of Cooperative Consumption Education Program Using Design Thinking in Home Economics Education: Focusing on the Improvement of Cooperative Problem Solving Competency of Middle School Students (디자인씽킹을 활용한 가정교과 협력적 소비 교육 프로그램의 개발 및 적용 효과: 중학생의 협력적 문제해결 역량 향상을 중심으로)

  • Kim, Seon Ha;Park, Mi Jeong
    • Journal of Korean Home Economics Education Association
    • /
    • v.33 no.3
    • /
    • pp.85-105
    • /
    • 2021
  • The purpose of this study is to develop and implement cooperative consumption education programs using design thinking in middle school home economics education classes to understand the impact on students' cooperative problem solving competency. Accordingly, a cooperative consumption education program based on design thinking was developed according to the ADDIE model, and the evaluation was conducted on a total of 25 students. The results of the study were as follows. First, based on prior research, we developed a consumption education program based on D. school's design thinking process under the theme of 'Creating a Shared School' for the practice of cooperative consumption. As a result of expert validity verification of the teaching/learning course plan and workbook for the eight sessions, the average question was 4.72 (out of 5 points) and the average CVI was 0.93, indicating that the content validity and field suitability were excellent. Second, to summarize the results achieved from the implementation of the cooperative consumption education program, the pre-/post-test using the revised and supplemented cooperative problem-solving competency tool, and the open-ended survey, It was confirmed that the developed program had a significant effect on improving not only the students' knowledge and perceived necessity for cooperative consumption along with the awareness of practice, but also the cooperative problem-solving competency. As a follow-up study, we propose to expand the research to a wider audience, and to further conduct research and develop programs applied with design thinking in home economics curriculum and in consumer competency development. This study confirmed that cooperative consumption education programs using design thinking are effective in improving youth's cooperative problem-solving competency and is meaningful in that they developed consumption education programs under the theme of 'cooperative consumption' in response to changing consumer education needs.