• 제목/요약/키워드: Test apparatus

검색결과 984건 처리시간 0.025초

국산 핀애자의 라디오 방해 전압(RIV) 평가 (Evaluation on the radio influence voltage of ${7^1/2}$ pin type domestic insulators)

  • 양배덕
    • 전기의세계
    • /
    • 제25권6호
    • /
    • pp.65-68
    • /
    • 1976
  • For the RIV characteristics test of power apparatus, an indoor measuring system of radio influence voltage was set up and by means of this measuring unit SIV characteristics on the 7$^{1}$2/" pin-type domestic insulators were examined. According to the test data, RIV values of all the test pieces exceeded the maximum permissible level at 10kV applied voltage. The electrical resistivity of domestic semi-conductive glaze as good as importedone but un-uniformity of coating is turned out to be a main cause of failure.lure.

  • PDF

불포화토의 흙-수분 특성곡선 (Soil-Water Characteristic Curves for an Unsaturated Soil)

  • 송창섭;임성윤;김명환
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.179-182
    • /
    • 2003
  • The purpose of this paper was to investigate the soil-water characteristic curves for unsaturated soil. To this ends, a series of suction measured test was conducted on the selected 4 kinds of soil which is located in Korea, used the modified pressure plate apparatus. From the test results, the water contents, degree of saturation and volumetric water contents was analyzed with the suction. And was drawn the soil-water characteristic curves was drain from the test results for various factors.

  • PDF

넓은 영역의 온도범위를 가지는 급속 온도특성측정시스템 컨트롤러 설계 (Design Controller For Rapidity Temperature Measurement-system)

  • 신광식;정완영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.33-36
    • /
    • 2001
  • An automatic TCXO frequency-temperature test apparatus was firstly developed by using thermoelectric device may. The developed system swing stably the test temperature range from -40$^{\circ}C$ to +80$^{\circ}C$ for about 1 hour The rising temperature ratio was fairly linear with time in this test temperature range. The temperature could be controlled error in error range of ${\pm}$0.05$^{\circ}C$ in this system. The frequency-Temperature properties of TCXO or the thermoelectric properties of other electric device.

  • PDF

용융탄산염형 연료전지 전극의 미세구조와 특성 (Characteristics and microstructure of MCFC electrode)

  • 김귀열;엄승욱
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권5호
    • /
    • pp.544-550
    • /
    • 1995
  • In this paper, the anode for molten carbonate fuel cell have been prepared by doctor blade method and microstructure, pore distribution, sintering test of the electrode were investigated. Component analysis were done by Scanning Electron Micrograph, porosimeter and sintering test apparatus. As a result, median pore size was 11.mu.m order at the major specimen and porosity was about 70%. And thickness loss of the electrode was 1.5% at Ni-10Co anode after sintering test.

  • PDF

나사 풀림 방지를 위한 걸림턱 구조의 와셔 개발 및 성능 비교 (Development and Benchmark Test of Hole-Boss Locking Washers for the Prevention of Vibrational Loosening)

  • 오영탁;김기대
    • 한국기계가공학회지
    • /
    • 제19권8호
    • /
    • pp.28-34
    • /
    • 2020
  • In this study, hole-boss locking washers were developed to prevent vibrational loosening, and a benchmark test was conducted to compare these washers with existing wedge locking washers, which are imported and high-priced. The developed washers consist of an upper washer with bosses and a lower washer with holes, and the bosses are caught in the holes so that the bolt is not loosened. Additionally, the top side of the upper washer and the underside of the lower washer have small wedges perpendicular to the direction of the bolt loosening, suppressing slips. A test by the Korea Test Laboratory indicated that the ratio of the loosening torque to the joining torque is greater than 70%, confirming that the developed washers have a sufficiently high anti-loosening performance. A Junker test apparatus was manufactured for the testing of vibrational loosening and a test comparison between the proposed washers and the existing wedge locking washers shows that the proposed washers have a slower reduction in the clamping force and a higher loosening-resistance in a vibrational circumstance compared with the wedge locking washers. These results indicate that the developed washers demonstrate a high performance and boast price competitiveness.

Stress and strain behavior investigation on a scale model geotextile tube for Saemangeum dike project

  • Kim, Hyeong-Joo;Lee, Kwang-Hyung;Jo, Sung-Kyeong;Jamin, Jay C.
    • Ocean Systems Engineering
    • /
    • 제4권4호
    • /
    • pp.309-325
    • /
    • 2014
  • Geotextile tubes are basically a huge sack filled with sand or dredged soil. Geotextile tubes are made of permeable woven or non-woven synthetic fibers (i.e., polyester or PET and polypropylene or PP). The geotextile tubes' performances in strength, dewatering, retaining solid particles and stacked stability have been studied extensively in the past. However, only little research has been done in the observation of the deformation behavior of geotextile tubes. In this paper, a large-scale apparatus for geotextile tube experiment is introduced. The apparatus is equipped with a slurry mixing station, pumping and delivery station, an observation station and a data station. For this study the large-scale apparatus was utilized in the studies regarding the stresses on the geotextile and the deformation behavior of the geotextile tube. Model tests were conducted using a custom-made woven geotextile tubes. Load cells placed at the inner belly of the geotextile tube to monitor the total soil pressure. Strain gauges were also placed on the outer skin of the tube to measure the geotextile strain. The pressure and strain sensors are attached to a data logger that sends the collected data to a desktop computer. The experiment results showed that the maximum geotextile strain occurs at the sides of the tube and the soil pressure distribution varies at each geotextile tube section.

맥진기(脈診器)를 이용한 아토피 피부염 환자의 임상적 고찰 (A clinical study of atopic dermatitis patients as measured by Pulse diagnostic apparatus)

  • 신윤진;김윤범;윤상협
    • 한방안이비인후피부과학회지
    • /
    • 제21권2호
    • /
    • pp.112-119
    • /
    • 2008
  • Objective : The quantification of pulse diagnosis is an important subject utilizing as a modernization of Oriental medical diagnosis and as a basic data for collaborative access between East and West Medicine. This study was to observe the tendency of pulse diagnosis in atopic dermatitis patients as measured by pulse diagnostic apparatus. Methods : We did pulse diagnostic test about 11 new outpatients who had visited the department of ophthalmology, otolaryngology, dermatology in Kyunghee oriental medical center from March 1, 2007 to October 31, 2007 and had atopic dermatitis. Results : The results were as follows. 1. Among the 11 outpatients, the total number of male patients were 5 and female patients were 6, and the age distribution, the most frequently visited age groups were 10-19 years old and 20-29 years old(each 4 patients). 2. The most common period of onset to first examination were 3 years${\leq}$ (7 patients). 3. There were 8 patients who had emphasized T-wave. 4. There were 7 patients who had repeated pulse wave pattern. Conclusion : In 11 cases who had atopic dermatitis, 8 patients had emphasized T-wave and 7 patients had repeated pulse wave pattern.

  • PDF

소형 스크류 프로펠라의 부식제거장치 개발 (Development of Corrosion Removing Unit for Small Screw Propeller)

  • 김귀식;한세옹;현창해
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.260-265
    • /
    • 2004
  • The materials of ship screw propeller are commonly the manganese bronze. The seawater corrosion and cavitation of the screw propeller reduce tire propulsive performance of ship. In screw manufactory, tire corrosion rust of tire screw propeller is removed by a hand grinding. The grinding work makes the dust of the heavy metals from the manganese bronze. The dust makes indoor working environment poor. A friendly-environmental and automatic corrosion removing apparatus was developed for the improvement of screw processing and working environment. The corrosion rust of a screw propeller was remarkably removed by using apparatus. And the screw surface roughness was improved by a blasting effect of the apparatus performance test. Anode polarization curves on jour processing conditions, that is to say, grinding, blasting, wire-brushing, fine sand papering, were confirmed by a potentiostat. Especially, two kinds of medias, alumina and emery, were used in the blasting processing. Then, investigated tire cavitation erosion of specimen. This result proved that tire blasting work has considerably improved the corrosion resistance of a screw propeller.

  • PDF

암반의 경계조건을 고려한 절리면 직접전단시험기 개발 (Development of a New Direct Shear Apparatus Considering the Boundary Conditions of Rock Joints)

  • 이영휘;김용준
    • 한국지반공학회논문집
    • /
    • 제19권2호
    • /
    • pp.147-157
    • /
    • 2003
  • 사면이나 터널과 같은 암반 구조물의 안정성에 영향을 미치는 절리면은 크게 절리면의 상태(돌기 강도, 충전재, 돌기 경사)와 주위 암반에 의해 구속되는 경계조건에 따라 지배된다. 본 연구에서는 암반 구조물에 작용하는 경계조건 과 절리상태에 따른 전단특성을 규명하기 위하여 PID 알고리즘에 의해 서보제어가 되는 절리면 전단시험 장비를 개발하였다. 그리고 돌기 경사가 일정한 톱니형 형상의 절리면에 대하여 일련의 실험을 수행하여 시험장비의 제어성능을 확인하고 사면이나 터널과 같이 경계조건이 다른 암반구조물에서는 전단강도 평가기법을 달리하여야 함을 알 수 있었다.

폼제에 의해 개선된 흙의 물성 도출을 위한 실내 가압 베인 전단시험 및 개별요소법의 적용 (Application of Laboratory Pressurized Vane Shear Test and Discrete Element Method for Determination of Foam-conditioned Soil Properties)

  • 강태호;이효범;최항석;최순욱;장수호;이철호
    • 한국지반신소재학회논문집
    • /
    • 제19권4호
    • /
    • pp.65-74
    • /
    • 2020
  • 토압식(EPB, earth pressure balance) 쉴드 TBM 공법에서 첨가제 주입을 통해 굴착한 흙을 개량하는 쏘일 컨디셔닝(soil conditioning) 기법의 적용은 TBM의 굴진성능을 향상시키는데 필수적이다. 따라서 TBM 장비의 굴진 성능을 모사하는 수치해석 모델에서도 쏘일 컨디셔닝을 적용하는 것은 중요하나, 이를 해석적으로 모사하는 기법에 대한 연구는 현재까지 부족하다. 따라서 본 연구에서는 컨디셔닝 된 흙의 특성을 파악하기 위해 실내 가압 베인시험 장치를 고안하였다. 고안된 장치를 통해 폼에 의해 컨디셔닝 된 흙에 대하여 전단속도를 달리하며 시험을 수행하였으며, 시험은 개별요소법(DEM, discrete element method)을 통해 모델링 되었다. 시험결과와 해석결과의 비교를 통해 개별요소법에서의 입자 접촉조건을 결정하였으며, 이는 개별요소법을 사용한 TBM 굴진해석 모델에서 쏘일 컨디셔닝을 재현할 때 가압 베인시험과 개별요소법 모델의 적용 가능성을 보여준다.