• Title/Summary/Keyword: Test Unit

Search Result 4,007, Processing Time 0.032 seconds

A Study on a Test Platform for AWS (All-Wheel-Steering) ECU (Electronic Control Unit) of the Bi-modal Tram (저상굴절버스 조향시스템 전자제어장치의 테스트플랫폼 구축에 관한 연구)

  • Lee, Soo-Ho;Moon, Kyeong-Ho;Park, Tae-Won;Kim, Ki-Jung;Choi, Sung-Hun;Kim, Young-Mo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1051-1059
    • /
    • 2008
  • In the development process of an ECU (Electrical Control Unit), numerous tests are necessary to evaluate the performance and control algorithm. The vehicle based test is expensive and requires long time. Also, it is difficult to guarantee the safety of the test driver. To overcome the various problems faced in the development process, the ECU test has been done using HIL (Hardware In the Loop). The HIL environment has the actual hardware including an ECU and a virtual vehicle model. In this paper, the test platform environment is devloped for the AWS ECU black box test. The test platform is built on HIL (Hardware In the Loop) architecture. Using the developed test platform, the control algorithm of the AWS ECU can be evaluated under the virtual driving condition of the bi-modal tram. Driving conditions, such as a front steering angle and vehicle velocity, are defined through the PC (Personal Computer) input. Input signals are transformed to electrical signals in the PC. These signals become the input conditions of the AWS ECU. The AWS ECU is stimulated by arbitory input conditons, and responses of the system are observed.

  • PDF

Mechanism and Behavior Characteristic of Space Truss Unit for Post-tensioning

  • Kim, Jin-Woo;Kim, Sang-Jin
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.6 no.1
    • /
    • pp.38-43
    • /
    • 2003
  • This paper presents the results of a post-tensioning test and analysis of a pyramidal unit structure that is basic element for space structures. The behavior characteristics was analyzed and compared with the numerical analysis and the mechanism in test model was confirmed with geometrical analysis. The results of this paper show that the behaviors of space structures can be predicted in multi-directional Mero joint system. And the authors suggest the possibility of erection and shaping formation with comparatively small post-tensioning, and space structure with the mechanism should consider the nonlinear behavior due to large deformation.

  • PDF

Design of a Real Time Simulator for Inverter Unit Test of PM Synchronous Motor (인버터 장치 실험용 영구자석 동기전동기의 실시간 시뮬레이터 설계)

  • Oh, Hyuncheal;An, Byoung Woong;Cho, Kwan Yuhl;Kim, Hag Wone;Cho, Jung Gu;Moon, Yong Gi
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.116-117
    • /
    • 2013
  • The real time simulator for testing the high power inverter unit of a PM synchronous motor is proposed. The power converter of the real time simulator can replaces the dynamo test equipment that consists of a PMSM(PM synchronous motor) and load unit. It is verified by the simulation that the real time simulator has a similar electrical and mechanical characteristics of the PM synchronous motor.

  • PDF

Nonstationary Time Series and Missing Data

  • Shin, Dong-Wan;Lee, Oe-Sook
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.1
    • /
    • pp.73-79
    • /
    • 2010
  • Missing values for unit root processes are imputed by the most recent observations. Treating the imputed observations as if they are complete ones, semiparametric unit root tests are extended to missing value situations. Also, an invariance principle for the partial sum process of the imputed observations is established under some mild conditions, which shows that the extended tests have the same limiting null distributions as those based on complete observations. The proposed tests are illustrated by analyzing an unequally spaced real data set.

Near optimal production scheduling for multi-unit batch process

  • Kim, Kyeong-Sook;Cho, Young-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1718-1723
    • /
    • 1991
  • The determination of a production sequence is an important problem in a batch process operation. In this paper a new algorithm for a near optimal production sequence of N product in an M unit serial multiproduct batch process is proposed. The basic principle is the same as that of Johnson's algorithm for two-unit UIS system. Test results on a number of selected examples exhibit the superiority over previously reported results. In addition, a tabulation technique is presented to calculate the makespan of a given sequence of production for all processing units under UIS mode.

  • PDF

BAYESIAN INFERENCE FOR MTAR MODEL WITH INCOMPLETE DATA

  • Park, Soo-Jung;Oh, Man-Suk;Shin, Dong-Wan
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2003.05a
    • /
    • pp.183-189
    • /
    • 2003
  • A momentum threshold autoregressive (MTAR) model, a nonlinear autoregressive model, is analyzed in a Bayesian framework. Parameter estimation in the presence of missing data is done by using Markov chain Monte Carlo methods. We also propose simple Bayesian test procedures for asymmetry and unit roots. The proposed method is applied to a set of Korea unemployment rate data and reveals evidence for asymmetry and a unit root.

  • PDF

Unit Root Tests for Autoregressive Moving Average Processes Based on M-estimators

  • Shin, Dong-Wan;Lee, Oesook
    • Journal of the Korean Statistical Society
    • /
    • v.31 no.3
    • /
    • pp.301-314
    • /
    • 2002
  • For autoregressive moving average (ARMA) models, robust unit root tests are developed using M-estimators. The tests are parametric in the sense ARMA parameters are estimated jointly with unit roots. A Monte-Carlo experiment reveals superiority of the parametric tests over the semipararmetric tests of Lucas (1995a) in terms of both empirical sizes and powers.

Performance Evaluation of a Driving Power Transmission System for 50 kW Narrow Tractors

  • Hong, Soon-Jung;Ha, Jong-Kyou;Kim, Yong-Joo;Kabir, Md. Shaha Nur;Seo, Young Woo;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • v.43 no.1
    • /
    • pp.1-13
    • /
    • 2018
  • Purpose: The development of compact tractors that can be used in dry fields, greenhouses, and orchards for pest control, weeding, transportation, and harvesting is necessary. The development and performance evaluation of power transmission units are very important when it comes to tractor development. This study evaluates the performance of a driving power transmission unit of a 50 kW multi-purpose narrow tractor. Methods: The performance of the transmission and forward-reverse clutch, which are the main components of the driving power transmission unit of multi-purpose narrow tractors, was evaluated herein. The transmission performance was evaluated in terms of power transmission efficiency, noise, and axle load, while the forward-reverse clutch performance was evaluated in terms of durability. The transmission's power transmission efficiency accounts for the measurement of transmission losses, which occur in the transmission's gear, bearing, and oil seal. The motor's power was input in the transmission's input shaft. The rotational speed and torque were measured in the final output shaft. The noise was measured at each speed level after installing a microphone on the left, right, and upper sides. The axle load test was performed through a continuous equilibrium load test, in which a constant load was continuously applied. The forward-reverse clutch performance was calculated using the engine torque to axle torque ratio with the assembled engine and transmission. Results: The loss of power in the transmission efficiency test of the driving power unit was 6.0-9.7 kW based on all gear steps. This loss of horsepower was equal to 11-18% of the input power (52 kW). The transmission efficiency of the driving power unit was 81.5-89.0%. The noise of the driving power unit was 50-57 dB at 800 rpm, 70-77 dB at 1600 rpm, and 76-83 dB at 2400 rpm. The axle load test verified that the input torque and axle revolutions were constant. The results of the forward-reverse clutch performance test revealed that hydraulic pressure and torque changes were stably maintained when moving forward or backward, and its operation met the hydraulic design standards. Conclusions: When comprehensively examined, these research results were similar to the main driving power transmission systems from USA and Japan in terms of performance. Based on these results, tractor prototypes are expected to be created and supplied to farmhouses after going through sufficient in-situ adaptability tests.