• Title/Summary/Keyword: Test Temperature

Search Result 10,040, Processing Time 0.035 seconds

The performance evaluation of dam management by using Granger causal analysis (그랜저 인과분석을 통한 댐관리 성과평가)

  • Cho, Sung-Min;Yoo, Myoung-Kwan;Lee, Deokro
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.2
    • /
    • pp.135-144
    • /
    • 2021
  • This paper attempted to find implications for water resource management and water quality improvement by analyzing the causal relationship among discharge, water temperature and pollution index, which were expected to have a great effect on water quality with the rise of water temperature and precipitation change as the warming effect in recent years. For this purpose, the unit root test, cointegration test, and Granger causal test were carried out for 10 multi-purpose dams in Korean major water systems using time series data on discharge, water temperature, BOD, COD and DO. It was analyzed that the fluctuation of water temperature affected the pollution index more than the fluctuation of discharge volume. Also, Hapcheon dam and Chungju dam were the best water quality management dams based on the high causal relationship between water quality and discharge. The second rank was Daecheong dam. The third-ranking group were Yongdam and Andong dam, whose causal relationships between water quality and discharge were low. The last group were the remaining five dams.

Thermal Performance Test of the On-Board Blackbody System in the orbital environment for Non-Uniformity Correction of an Infrared Sensor (적외선 센서 교정용 위성 탑재 흑체 시스템의 궤도 환경 열성능 평가 시험)

  • Pil-Gyeong, Choi;Hye-In, Kim;Hyun-Ung, Oh;Byung-Cheol, Yoo;Kyoung-Muk, Lee;Jin-Suk, Hong
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.6
    • /
    • pp.90-98
    • /
    • 2022
  • The output of an infrared (IR) sensor mounted on an EO/IR payload is known to change during a mission period in an orbital environment. As it is required to calibrate the output of the IR sensor periodically to obtain high-quality images, an on-board black body system is mounted on the payload. All systems operating in the space environment require performance tests on ground to verify the target performance in the orbital environment. Therefore, it is also required to test the black body system to verify the performance of the surface temperature uniformity and the estimated representative temperature error within the target temperature range in the operating environment. In this study, calibration of the estimated representative temperature error and verification of the thermal performance of the black body system were conducted by performed a performance test in the thermal vacuum chamber applying deep space radiation cooling effect of an orbital environment.

Reliability and responsiveness of Equivital Lifemonitor and photoplethysmography based wristwatch for the assessment of physiological parameters during a simulated fatigue task

  • Anwer, Shahnawaz;Li, Heng;Umer, Waleed;Antwi-Afari, Maxwell Fordjour;Wong, Arnold YL
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.257-264
    • /
    • 2020
  • Objective: To investigate test-retest reliability and responsiveness of Equivital Lifemonitor and photoplethysmography based wristwatch tools in assessing physiological parameters during a simulated fatigue task. Methods: Ten university students (Mean age, 30.6 ± 1.7 years) participated in this pilot study. Participants were asked to perform a 30-minute of a simulated fatigue task in an experimental setup in a lab. The physiological parameters (e.g., heart rate, heart rate variability, respiratory rate, electrodermal activity, and skin temperature) were measured at baseline and immediately after the fatigue task. An intraclass correlation coefficient (ICC2,1) was used to evaluate the test-retest reliability of each tool in assessing physiological measures. In addition, the responsiveness of each tool to measure changes from baseline to posttest was calculated using a standardized response mean. Results: The Equivital Lifemonitor has shown good to excellent test-retest reliability for the assessment of heart rate (ICC, 0.97), heart rate variability (ICC, 0.86), respiratory rate (ICC, 0.77), and local skin temperature (ICC, 0.76). However, photoplethysmography based wristwatch showed moderate to good test-retest reliability for the assessment of heart rate (ICC, 0.71), heart rate variability (ICC, 0.73), electrodermal activity (ICC, 0.80), and skin temperature (ICC, 0.72). A large standardized response mean (>0.8) indicates that both tools can capture the changes in heart rate, heart rate variability, respiratory rate, skin temperature, and electrodermal activity after a 30-minute of fatigue task. Conclusions: The Equivital Lifemonitor and photoplethysmography based wristwatch devices are reliable in measuring physiological parameters after the fatigue task. Additionally, both devices can capture the fatigue response after a simulated construction task. Future field studies with a larger sample should investigate the sensitivity and validity of these tools in measuring physiological parameters for fatigue assessment at construction sites.

  • PDF

Effects of Increasing Ambient Temperatures on the Static Load Performance and Surface Coating of a Gas Foil Thrust Bearing (외기 온도 증가가 가스 포일 스러스트 베어링의 하중지지 성능과 표면 코팅에 미치는 영향)

  • Hyunwoo Cho;Youngwoo Kim;Yongbum Kwon;Tae Ho Kim
    • Tribology and Lubricants
    • /
    • v.40 no.3
    • /
    • pp.103-110
    • /
    • 2024
  • Gas foil thrust bearings (GFTBs) are oil-free self-acting hydrodynamic bearings that support axial loads with a low friction during airborne operation. They need solid lubricants to reduce dry-friction between the runner and top foil and minimize local wears on their surfaces during start-up and shutdown processes. In this study, we evaluate the lift-off speeds and load capacity performance of a GFTB with Polytetrafluoroethylene (PTFE) surface coating by measuring drag torques during a series of experimental tests at increasing ambient temperatures of 25, 75 and 110℃. An electric heat gun provides hot air to the test GFTB operating in the closed booth to increase the ambient temperature. Test results show that the increasing ambient temperature delays the lift-off speed and decreases the load capacity of the test GFTB. An early developed prediction tool well predicts the measured drag torques at 60 krpm. After all tests, post inspections of the surface coating of the top foil are conducted. Scanning electron microscope (SEM) images imply that abrasive wear and oxidation wear are dominant during the tests at 25℃ and 110℃, respectively. A quantitative energy dispersive spectroscopy (EDS) microanalysis reveals that the weight percentages of carbon, oxygen, and nitrogen decrease, while that of fluorine increases significantly during the highest-temperature tests. The study demonstrates that the increasing ambient temperature noticeably deteriorates the static performances and degrades the surface coating of the test GFTB.

A Numerical Study on the Thermal Behavior Evaluation of Bentonite Buffer (벤토나이트 완충재의 열적 거동 평가에 관한 수치해석적 연구)

  • Yoon, Chan-Hoon;Choi, Young-Chul;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.2
    • /
    • pp.99-112
    • /
    • 2015
  • In this study, laboratory test equipment was designed and installed to evaluate the thermal behavior of bentonite, which is used as a buffer in high-level waste disposal systems. The thermal analysis was conducted to verify the test results using ABAQUS, a finite element analysis code. In view of the seasonal changes seen during the test, the thermal behavior of bentonite with a temperature of outside air was evaluated. Of the cases examined, the results of the analysis model using stainless steel (Case 3) approximates to the test results, showing an error of about 1℃. The results of the thermal analysis into seasonal temperature distributions are consistent with trends seen in lab-test results. These analyses show that the effects of the thermal conductivity of the material surrounding the buffer and outside air temperature, are very important factors in the thermal behavior of bentonite. In the future, it is expected that a moisture saturation test of a bentonite buffer containing a heat source will be carried out. Therefore, the development of a numerical analysis model is required for the prediction and verification of the laboratory test results.

Evaluation of the Applicability of Structural Steels to Cold Regions by the Charpy Impact Test (샤르피 충격시험을 통한 구조용강재의 극한지 적용성 검토)

  • Lee, Chin-Hyung;Shin, Hyun-Seop;Park, Ki-Tae;Yang, Seunng-Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.483-491
    • /
    • 2011
  • The fabrication of steel structural members always involves welding process such as flux cored arc welding. Therefore, for the application of structural steels to cold regions, it is a prerequisite to clarify the service temperature of the welded joints in order to ensure the structural integrity of the welded parts. In this study, the Charpy impact test was conducted to evaluate the service temperature of structural steel weld. The Charpy impact test is a commercial quality control test for steels and other alloys used in the construction of metallic structures. The test allows the material properties for service conditions to be determined experimentally in a simple manner with a very low cost. Standard V-notch Charpy specimens were prepared and tested under dynamic loading condition. The service temperatures of the weld metal, HAZ (heat affected zone) and base metal were derived by the absorbed energy and the impact test requirements; thus the applicability of the structural steels to cold regions was discussed in detail.

Effect of Hydraulic Loading Rate of a Continuous Stirred Tank Reactor(CSTR) on the Removal Efficiency of Pollutants of Pig Slurry (CSTR의 수리학적 부하율이 돈슬러리의 유기물 및 영양염류 저감효율에 미치는 영향)

  • 정우철;최홍림
    • Journal of Animal Environmental Science
    • /
    • v.5 no.3
    • /
    • pp.189-196
    • /
    • 1999
  • Anaerobic digestion is a naturally occuring microbial process involving the decomposition of organic materials such as livestock manure. This study explores the effect of the operating conditions, HRT (Hydraulic Retention Time) and feeding frequency on treatment efficiency for digestion of pig slurry, which has been one of most difficult organic waste for proper treatment in livestock production industry in Korea at the present time. The pilot-scale CSTR of 5 m3 in volume was designed. manufactured, and operated at the temperature of 35$\pm$1$^{\circ}C$. The digester was designed to hydraulically stir for complete mixing and to supply heat from the water bath to maintain mesophilic temperature. The HRT of the digester for Test 1 and Test 2, and Test 3 was set for 17 days and 13 days respectively and pig slurry was fed once a day with 300$\ell$ each for Test 1 and Test 3, while twice with 150$\ell$each for Test 2. Test 2 showed better performance by increase of 4% in VS removal efficiency and 5% in biogas production rate. This is mainly attributed to smaller temperature drop by feeding frequently with half amount, which eventually led to lesser impact on anaerobic mocrobes in the digester. Test 2 maintained optimum pH 7.8 which uplifted the activaton of sulfur-reduction bacteria, alkalinity of around 4,000mg/$\ell$, VA of over 3,000mg/$\ell$ for whole period of experiment. Further research may require to provide the practical operation strategy of anaerobic treatment system for treatment of pig slurry.

Performance Test of Cooling System for the KEPCO HTS Power Cable (한전 초전도전력케이블 냉각시스템 성능시험)

  • Yang, H.S.;Kim, D.L.;Sohn, S.H.;Lim, J.H.;Choi, H.O.;Lee, B.S.;Choi, Y.S.;Ryoo, H.S.;Hwang, S.D.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2206-2210
    • /
    • 2007
  • As a power transmission line supplying power to a densely populated city, the high temperature superconducting (HTS) cable is expected to one of the most effective cables with a compact size because of its high current density. The verification of HTS power cable system have been progressed by KEPRI. A cooling system for a 3-phase 100m HTS power cable with 22.9kV/1.25kA was installed and tested at KEPCO's Gochang power testing center in Korea. The system consists of a liquid nitrogen decompression cooling system with a cooling capacity of 3kW and a closed circulation system of subcooled liquid nitrogen. Several performance tests of the cable system with respect to the cooling such as cooling capacity, heat load and temperature stability, were performed at several temperatures. Thermal cycle test, cool-down to liquid nitrogen temperature and warm-up to room temperature, was also performed to investigate thermal cycle influences. The outline of the installed cooling system and performance test results are presented in this paper.

  • PDF

An Experimental Study on the Thermal Performance Measurement of Standing Column Well type Borehole Heat Exchanger (스탠딩컬럼웰형(SCW) 지중열교환기의 열성능 측정에 관한 실험적 연구)

  • Lee, Sanghoon;Choe, Yongseok;An, Kunmuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.122.2-122.2
    • /
    • 2010
  • Knowledge of ground thermal properties is most important for the proper design of BHE(borehole heat exchanger) systems. The configure type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for in-situ determination of design data for Standing Column Well apply. The main purpose has been to determine in-situ values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a sub-circulation pump, a boiler, temperature sensors, flow meter and a data logger for recording the temperature and circulation fluid flow data. A constant heating power is injected into the SCW through the test rig and the resulting temperature change in the SCW is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective in-situ values of rock thermal conductivity and thermal resistance of SCW.

  • PDF

Yielding Behavior and Strain Aging Properties of Bake Hardening Steel with Dual-Phase Microstructure (2상 조직을 갖는 소부경화강의 항복 거동과 변형 시효 특성)

  • Lee, Seung-Wan;Lee, Sang-In;Hwang, Byoungchul
    • Korean Journal of Materials Research
    • /
    • v.30 no.6
    • /
    • pp.315-320
    • /
    • 2020
  • This study deals with the yielding behavior and strain aging properties of three bake hardening steels with dual-phase microstructure, fabricated by varying the annealing temperature. Bake hardening and aging tests are performed to examine the correlation of martensite volume fraction with yielding behavior and strain aging properties of the bake hardening steels with dual-phase microstructure. The volume fraction of martensite increases with increasing annealing temperature. Room-temperature tensile test results show that the yielding behavior changes from discontinuous-type to continuous-type with increasing volume fraction of martensite due to higher mobile dislocation density. According to the bake hardening and aging tests, the specimen with the highest fraction of martensite exhibited high bake hardening with low aging index because solute carbon atoms in ferrite and martensite effectively diffuse to dislocations during the bake hardening test, while in the aging test they diffuse at only ferrite due to lower aging temperature.