• 제목/요약/키워드: Test Temperature

검색결과 10,026건 처리시간 0.054초

기계류부품의 고온상승, 고 토크와 미소토크의 시험장치 개발 (Development of machinery parts test device for the rising high temperature and measuring large and tiny scale torque)

  • 이용범;박종원;이근호
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제13권1호
    • /
    • pp.11-18
    • /
    • 2013
  • For a reliability assessment of machinery parts, accurate performance test, environmental test, life test, etc. are required on the sample. In the performance test conditions of various machinery parts, some problems happen such as needs to rise temperature rapidly with large flow of oil having very low thermal conductivity and to measure very high torque or tiny torque, etc. This study brings out the method to apply heat to rise temperature for large flow of oil without chemical change in a performance test of oil cooler. To measure large scale of torque in a performance test of planetary gearbox of excavator, the method of torque measurement is proposed by replacing the large torque meter priced very expensive. To measure very small torque on lubricated friction, a methode of force balance type test mechanism is introduced for tests of piston assembly.

다구찌 설계를 이용한 듀플렉스 스테인리스강 S31083용 DL-EPR 시험용액의 최적화 (Optimization of DL-EPR Test Solution for Duplex Stainless Steel S31083 Using Taguchi Design)

  • 정광후;김성종
    • Corrosion Science and Technology
    • /
    • 제20권2호
    • /
    • pp.77-84
    • /
    • 2021
  • This study aims to optimize the DL-EPR test solution for duplex stainless steel S31083 using the Taguchi design. The test solution parameters applied to the Taguchi design are H2SO4, NaCl, KSCN concentration, and temperature. In the experimental design, an orthogonal array of 4 levels 4 factor L16(44) was used. Output values for the orthogonal array were used for resolution (degree of sensitization) and selective etch (Ia) values. The optimal test solution conditions were selected by comparing the normalized S/N ratio for the two reaction properties. As a result, the H2SO4 and NaCl were identified as the main factors influencing the sensitivity measurement, but the delta statistics showed that the KSCN concentration and temperature had relatively low influence. The optimal condition was identified as 1.5 M H2SO4+0.03 M KSCN+1.5M NaCl at 30 ℃. The degree of sensitization presented a tendency to depend on the heat treatment temperature and time in the optimal test solution. This investigation confirmed the possibility of optimizing the experiment solution for the DL-EPR test of stainless steel using the Taguchi technique.

반도체 테스트 핸들러의 온도제어 시스템 개발 II - 제어기 설계 (Development of Temperature Control System for Semiconductor Test Handler II - Controller Design)

  • 김재용;강태삼;이호준;선기상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.77-80
    • /
    • 1997
  • In this paper presented is a temperature controller for a semiconductor test handler. Using ARMAX model and least square method, the chamber model for the design of a controller is identified through experiment. With the identified model an LQG/LTR controller is designed. Experiment with a real test handler demonstrated good performance in that its overshoot is small and response time is fast.

  • PDF

금형주조한 Mo-Ni-Cu계 구상흑연주철의 오스템퍼링 온도 및 시간에 따른 파괴특성 (Fracture Properties of Mo-Ni-Cu Austempered Ductile Iron Cast in Permanent Mold with Austempering Temperature and Time)

  • 이영상;강인찬
    • 한국주조공학회지
    • /
    • 제11권4호
    • /
    • pp.331-337
    • /
    • 1991
  • Various test specimens were prepared by austempering low alloyed Mo-Ni-Cu ductile iron blocks of high graphite nodule count at 270, 320 or $370^{\circ}C$ for 0.5, 1, 3 or 9hrs. Tensile test, CVN impact test and plane-strain fracture toughness test(compact tension specimen of 50mm W) were done for each heat treatment condition at room temperature. X-ray diffractometer and optical microscope were used to investigate the change of microstructure and relationships between microstructure and test results. The highest retained austenite volume percent at each austempering temperature was corresponded to the highest mechanical property. The highest elongation value of 17%, U.T.S. value of 1,600 MPa or $K_{IC}$ value of 90MPa${\surd}$m were reached at each optimum condition. The best heat treatment condition for fracture toughness were 3hrs' holding time combined with the austempering temperature of 270 and $320^{\circ}C$, and 1hr's of $370^{\circ}C$.

  • PDF

Practical Application of Lead-free Solder in Electronic Products

  • Cho Il-Je;Chae Kyu-Sang;Min Jae-Sang;Kim Ik-Joo
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2004년도 ISMP Pb-free solders and the PCB technologies related to Pb-free solders
    • /
    • pp.93-99
    • /
    • 2004
  • At present, LG Electronics pushes ahead to eliminate the Pb(Lead) -a hazardous material- from all products. Especially, we have performed to select the optimum standard composition of lead free alloy for the application to products for about 3 years from 2000. These days, we have the chance for applying to the mass-production. This project constructed the system for applying the lead free solders on consumer electronic products, which is one of the major products of the LG Electronics. To select the lead free solders with corresponding to the product features, we have passed through the test and applied with Sn-3.0Ag-0.5Cu alloy system to our products, and for the application to the high melting temperature composition, we secured the thermal resistance of the many parts and substrate and optimized the processing conditions. We have operated the temperature cycling test and the high temperature storage test under the standards to confirm the reliability of the products. On these samples, we considered the consequence of our decision by the operating test. For the long life time of the product, we have operated the temperature cycling test at $-45^{\circ}C-+125^{\circ}C$, 1 cycle/hour, 1000 cycles. Also we have tested the tin whisker growth about lead free plating on lead finish. We have analyzed with the SEM, EDS and any other equipment for confirming the failure mode at the joint and the tin whisker growth on lead free finish.

  • PDF

Effects of Temperature and Compost Conditions on the Biodegradation of Degradable Polymers

  • Jung, Eun-Joo;Shin, Pyong-Kyun;Bae, Hee-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권4호
    • /
    • pp.464-468
    • /
    • 1999
  • The effectiveness of current biodegradation test methods for degradable polymers under controlled composting conditions was studied in regards to the test temperature and compost condition. When biodegradability tests for the natural (starch, cellulose, PHB/HV) and synthetic (PCL, SG, PLA) polymers were conducted at temperature levels of 35 and $55^{\circ}C$ with compost cured at ambient temperature, the degradations of cellulose and starch were higher at $35^{\circ}C$ because of the priming effect. On the other hand, degradations of other polymers were higher at $55^{\circ}C$. In the biodegradation test at $55^{\circ}C$, compost harvested right after the thermophilic degradation stage showed higher biodegradation activities than the cured compost for both the synthetic aliphatic polyester (SG) and a natural polymer, cellulose. These results suggest that the biodegradation test conducted at $55^{\circ}C$ with the compost, harvested right after the thermophilic degradation stage during composting, showed the highest biodegradation activity under controlled composting conditions.

  • PDF

CaO가 첨가된 Mg-3Al, Mg-6Al 및 Mg-9Al Eco-Mg 합금의 발화 저항성 평가 (Ignition resistance of CaO added Mg-3Al, Mg-6Al and Mg-9Al Eco-Mg alloys)

  • 이진규;김세광
    • 한국주조공학회지
    • /
    • 제31권2호
    • /
    • pp.60-65
    • /
    • 2011
  • Molten magnesium alloys and magnesium products are easily oxidized and burned when they are exposed to high temperature for manufacturing process and by accident. In order to solve these problems, CaO addition in magnesium alloys has been developed. The ignition resistance of CaO added Mg-3Al, Mg-6Al, and Mg-9Al Eco-Mg alloys were investigated in comparison with those of magnesium alloys without CaO. The ignition resistance was examined by three methods : DTA, furnace chip ignition test, and torch ignition test. DTA was carried out for obtaining quantitative ignition temperature data with respect to specimen geometry and test environment; the furnace ignition test for burr and chip ignition temperature data; and the torch test for ignition temperature data for manufactured products. The ignition resistance of magnesium alloys under all conditions greatly increased by CaO addition.

Charpy 충격시편을 이용한 압력용기 재료의 파괴인성 측정 (Evaluation of Fracture Toughness of Pressure Vessel Steel Using Charpy Impact Test Specimens)

  • Han, Dae-June;Park, Sun-Pil
    • Nuclear Engineering and Technology
    • /
    • 제19권1호
    • /
    • pp.1-9
    • /
    • 1987
  • 원자로 압력용기 재료인 SA 533 Grade B Class 1강의 파괴인성에 대하여 -4$0^{\circ}C$~288$^{\circ}C$의 온도 구간에서 Charpy 충격시편을 이용하여 연구하였다. 동적 파괴인성은 계장화 충격시험으로, 정적 파괴인성은 unloading compliance 방법에 따라 3-point bend test로 수행되었으며, 결과는 큰 시편에 의한 자료와 비교하였다. 온도에 대한 재료의 적절한 파괴인성치(하한값)는 천이온도 이상에서는 정직 파괴인성을, 그 이하의 온도에서는 동적 파괴인성을 택함으로써 유추할 수 있음을 알게 되었으며 side-groove가 14%이상일 때 시험은 ASTM E 813의 조건을 만족함을 보였다.

  • PDF

무연솔더 동판부식 시험법 연구 (Cu Corrosion Test Method for Lead-Free Solders)

  • 김미송;홍원식;오철민;김근수
    • Journal of Welding and Joining
    • /
    • 제35권3호
    • /
    • pp.21-27
    • /
    • 2017
  • A soldering temperature of ($235{\pm}3$) $^{\circ}C$ is described in ISO 9455-15 for the copper corrosion test. However, this temperature is not suitable for performing lead-free solder pastes. We evaluated the compatibility of a lead-free solder paste in the experimental conditions of (Liquidus temperature + ($35{\pm}3$)) $^{\circ}C$. Based on the results after a Cu corrosion test, a proper temperature for Pb-free soldering was (melting point+($35{\pm}3$)) $^{\circ}C$. Criteria used to evaluate corrosion due to discoloration of flux residue is described in ISO 9455-15, but a more quantitative evaluation standard is needed. In this study, experimental error level was estimated by analyzing flux residue after a corrosion test for 72, 500 hours of specimens using EDS analysis with acceleration voltage. It was determined that the copper area at the flux residue boundary is suitable for the EDS analysis area.

혈압 관리를 위한 4주간의 착의훈련이 고혈압 전단계자의 내열성에 미치는 영향 (Effects of a Four-week Clothing Program for Improving Vascular Compliance on Heat Tolerance)

  • 최정화;박준희
    • 한국지역사회생활과학회지
    • /
    • 제22권3호
    • /
    • pp.445-454
    • /
    • 2011
  • This study was performed on 5 prehypertensive male participants to investigate the effects of the clothing program for improving the vascular compliance on heat tolerance. The clothing program means the alternate stimulation of the temperature using clothes. The participants wore two different garments with $1.5^{\circ}C$ difference in the temperature inside clothing in a climatic chamber ($18.8{\pm}0.2^{\circ}C$, $38{\pm}3%RH$) alternately for 4 weeks. Heat tolerance tests were conducted in the climatic chamber of $35.2{\pm}0.5^{\circ}C$, $54{\pm}3%RH$ before and after the clothing program. The results were as follows. The $\overline{T}$sk, Tr and heart rate were lower in the post test than in the pre test (p<.01). The whole body and local sweat rates as well as systolic and diastolic blood pressures had reduced the tendencies in the post test. Participants felt less wet and more comfortable in the post test than in the pre test(p<.01). These results showed that the clothing program through the alternate stimulation of the temperature positively affected the improvement of heat tolerance.