• 제목/요약/키워드: Test Socket

검색결과 119건 처리시간 0.023초

Relationships Between the Transfemoral Socket Interface Pressure and Myoelectric Signal of Residual Limb During Gait

  • Hong, J.H.;Lee, J.Y.;Chu, J.U.;Lee, J.Y.;Mun, M.S.
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1070-1073
    • /
    • 2002
  • The biomechanical interaction between the stump and the prosthetic socket is critically important to achieve close-to-normal ambulation. Many investigators suggested that the pressure changes during gait of transfemoral amputees are closely related to the prosthetic alignment, the socket shape, the stump size, and the residual muscle activity. The effects of the prosthetic alignment, the socket shape, and the stump size on the interface pressure were investigated previously. However, there is no report how the residual muscle activities in the transfemoral stump affect the socket interface pressure characteristics during gait. Since designs of socket fur lower limb amputees need to consider the socket interface pressure characteristics, the interface pressure patterns by the residual muscle activities during gait should be investigated. In this study, myoelectric signals (MES) and socket interface pressure in residual limb of transfemoral amputees were measured during the stance and swing phases of gait. For the purpose, specially designed quadrilateral sockets that MES electrodes could be instrumented were fabricated. A total of two transfemoral amputees were participated in the experiments. The measured temporal MES amplitude and interface pressure in knee flexor (biceps femoris) and extensor (rectus femoris) had significant correlations (P < 0.05). Based on the test results, It was suggested that the residual muscle activity of transfemoral amputees stump is an important factor affecting socket pressure changes during walk.

  • PDF

Pressure Distribution in Stump/Socket Interface in Response to Socket Flexion Angle Changes in Trans-Tibial Prostheses With Silicone Liner

  • Kang, Pil;Kim, Jang-Hwan;Roh, Jung-Suk
    • 한국전문물리치료학회지
    • /
    • 제13권4호
    • /
    • pp.71-78
    • /
    • 2006
  • This study examined the effects of socket flexion angle in trans-tibial prosthesis on stump/socket interface pressure. Ten trans-tibial amputees voluntarily participated in this study. F-socket system was used to measure static and dynamic pressure in stump/socket interface. The pressure was measured at anterior area (proximal, middle, and distal) and posterior area (proximal, middle, and distal) in different socket flexion angles ($5^{\circ}$, $0^{\circ}$, and $10^{\circ}$). Paired t-test was used to compare pressure differences in conventional socket flexion angle of $5^{\circ}$ with pressures in socket flexion angles of $0^{\circ}$ and $10^{\circ}$ (${\alpha}$=.05). Mean pressure during standing in socket flexion angle of $10^{\circ}$ decreased significantly in anterior middle area (19.7%), posterior proximal area (10.4%), and posterior distal area (16.3%) compared with socket flexion angle of $5^{\circ}$. Mean pressure during stance phase in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (19.3%) and decreased significantly in anterior distal area (19.7%) compared with socket flexion angle of $5^{\circ}$. Mean pressure during stance phase in socket flexion angle of $10^{\circ}$ decreased significantly in anterior proximal area (19.6%) and increased significantly in anterior distal area (8.2%) compared with socket flexion angle of $5^{\circ}$. Peak pressure during gait in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (23.0%) compared with socket flexion angle of $5^{\circ}$ and peak pressure during gait in socket flexion angle of $10^{\circ}$ decreased significantly in anterior proximal area (22.7%) compared with socket flexion angle of $5^{\circ}$. Mean pressure over 80% of peak pressure ($MP_{80+}$) during gait in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (23.9%) and decreased significantly in anterior distal area (22.5%) compared with socket flexion angle of $5^{\circ}$. $MP_{80+}$ during gait in socket flexion angle of $10^{\circ}$ decreased significantly in anterior distal area (34.1%) compared with socket flexion angle of $5^{\circ}$. Asymmetrical pressure change patterns in socket flexion angle of $0^{\circ}$ and $10^{\circ}$ were revealed in anterior proximal and distal region compared with socket flexion angle of $5^{\circ}$. To provide comfortable and safe socket for trans-tibial amputee, socket flexion angle must be considered.

  • PDF

웹소켓을 이용한 모바일 앱 테스트 시스템 설계 (A Design of Mobile App Test System Using Web Socket)

  • 최경수;이길흥
    • 한국IT서비스학회지
    • /
    • 제17권3호
    • /
    • pp.63-75
    • /
    • 2018
  • In this paper, we propose a testing method of the quality of device application effectively reflecting the necessity of increasing mobile device application quality test, and designed and developed it as a web system. We have studied traditional software testing methods for designing and developing a system. We have developed a next-generation alternative technology that can analyze and compensate for the weaknesses of the web and weaknesses of the Android in order to realize the access system and the responsive web system. As an example applied to the system, we analyzed the requirements of the system implementation and expressed the functions of the system through the use case diagram. The test scenarios were conducted by connecting 5,000 devices to each system using the existing HTTP polling method and the proposed web socket method. After setting the comparative group, the result of the proposed web management system was observed and compared through repeated tests. The research shows that the proposed web socket system has better performance than HTTP polling. The more the number of simultaneous processing of the devices, the lower the server stability but the better the time efficiency. In conclusion, the more the number of devices to be tested is, the more the number of devices can be effectively tested using the proposed web management system.

제거식 쏘일네일의 고정자소켓 강도에 관한 실험적 해석 (Experimental Analysis of the fixed socket strength of a removable soil nail)

  • 김낙경;김성규;윤승권;조규완;김웅규;이충호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1250-1253
    • /
    • 2008
  • As a reinforcement technique, the application of removable soil nailing has been extended to solve the public grievance of typical soil nailing such as the geotechnical environmental problem and invasion of adjacent land. In the case of removable soil nailing, pullout capacity of the nail depends on the adhesive strength of a fixed socket. Because the existing fixed socket is made from a plastic product, the strength of a socket is less than a steel bar and then the yield failure by abrasion and deformation is occurred on the steel bar-socket contact surface. In this study, therefore, experimental analysis from laboratory test of a removable soil nail equipped with steel socket, improving the adhesive strength of steel bar-socket connection is performed to estimate the increase effect of pullout capacity of a soil nail.

  • PDF

안전형 비납땜 틀고정 영구 접속형 멀티콘센트 개발에 관한 연구 (A Study on Safe Permanent Joint Type Multiple Socket-Outlets Development without Soldering Crimped Connection)

  • 조원석;이위로
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.47-54
    • /
    • 2015
  • Normally, multiple socket-outlet is manufactured with soldered, welded permanent connection (termination). Because this procedure is very non-environmental and requires many labor forces, many companies skip this process. To solve this these problems, this research had to design permanent joint type multiple socket-outlet, develop safer multiple socket-outlet than is sold in markets. Progressing this research, we took 3 steps. First, we had to design device for fixing a frame suitable for multiple socket-outlet. Second, this multiple socket-outlet must pass fundamental standards through international standard (IEC 60884-1) and Korean standard (K 60884-1) tests. Third, it had to pass both several mechanical and electrical tests which is more strict than fundamental standards and vibration and impact tests following KS standards for enhancing its safety. After finishing 3 steps, we could obtain objective and fair data, develop environmental permanent joint type multiple socket-outlet without soldering crimped connection.

Failure Analysis of BGA Test Socket Pins

  • Kim, Myung-Sik;Bae, Kyoo-Sik
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2008년도 추계학술발표대회 및 제15회 신소재 심포지엄
    • /
    • pp.23.2-23.2
    • /
    • 2008
  • PDF

유입부 비대칭 노즐의 성능연구 (Performance Study of Supersonic Nozzle with Asymmetric Entrance Shape)

  • 이지형;김중근;이도형
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.40-45
    • /
    • 2005
  • 현재까지 적용되고 있는 추력제어 장치로는 크게 노즐의 확대부에 장착되어 화염의 방향을 조종하는 제트베인(jet vane), 제트탭(jet tab)방식과 노즐자체를 회전하는 방식인 볼/소켓형(ball & socket) 노즐, 플렉시블 씰형 (flexible seal)노즐로 구분된다. 본 연구는 노즐자체를 회전하여 추력방향을 제어하는 볼/소켓형(ball & socket) 노즐이 회전할 경우 발생되는 유입부의 비대칭성이 노즐 성능에 미치는 영향을 예측하기 위하여 수행한 3차원 수치해석결과와 공압시험 결과를 수록하였다. 유동해석 결과 유입부의 비대칭성이 유동에 미치는 영향은 노즐 목까지 점차적으로 줄어들고 하류 유동에 미치는 영향이 미비하였으며 해석된 주 추력의 크기는 시험에서 측정된 추력과 비슷한 경향을 나타내었으나 측 추력의 경우 시험 값보다 낮게 나타났다.

  • PDF

IC 소켓 검사용 다중 채널 측정 시스템 개발 (Development of Multiple Channel Measurement System for IC Socket)

  • 강상일;송성용;윤달환
    • 전기전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.315-321
    • /
    • 2021
  • 본 논문에서는 초소형 반도체 부품 IC 소켓 검사에 필요한 다중 채널 시험장치를 개발한다. 이 시험장치는 저 저항(수 mΩ급)으로 저전류(수 uA급)~5A 범위의 미세전류상태에서 생산 시스템 요구 규격에 맞는 IC를 다양한 형태로 시험분석을 실행한다. 0.25 mm이하의 리드피치(Lead Pitch)를 가진 IC 소켓 채널수의 증가로 다양한 시험을 동시에 실행해야하는 시험장비는 회로의 고집적화를 위하여 여러 개의 SMU(Source Measure Unit) 보드를 동시에 탑재하도록 구성된다. Daisy chain test method를 통하여 채널지점(Channel Point)당 약 2분 소요되는 시험시간(Test Time)을 40 초(sec) 이내로 단축이 가능하고, 그래픽 기반 인터페이스, 분석 도구(I-V Curve Mode 등) 및 데이터 로깅(Data Logging)을 통한 테스트 플로우 분석을 구현함으로써 시험시간과 소요비용을 절감한다.

유한요소법을 이용한 고압유압펌프용 오목형 피스톤 조립체의 소켓 형상 설계 (Finite Element Approach to Socket Shape Design of a Concave Piston Assembly for a High Pressure Hydraulic Pump)

  • 엄재근;이민철;최인수;조유종;전만수
    • 대한기계학회논문집A
    • /
    • 제30권11호
    • /
    • pp.1433-1438
    • /
    • 2006
  • A systematic approach to socket shape design of a concave piston assembly for a high pressure hydraulic pump of an excavator is presented in this paper. A design model is given and a methodology of socket shape design is proposed. An axisymmetric rigid-plastic finite element method is employed for predicting the approximate socket shape formed by a rotary forming process as well as for simulating the test process for separating the shoe from the piston assembly designed. It is verified that the predictions are in good agreement with the experiments. The approach is successfully applied to developing an optimal concave piston assembly.

반도체 생산 시스템의 자동 Socket 관리 기술 개발 (Development of an Auto Socket Management Technique for Semicon Production Syste,)

  • 정화영;김종훈
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 1999년도 가을 학술발표논문집 Vol.26 No.2 (3)
    • /
    • pp.167-169
    • /
    • 1999
  • 산업응용 시스템에 있어서의 생산성이란 시스템의 성능 및 효율성에 관한 척도가 된다. 따라서, 시스템의 개발 전과정에서 이를 향상시키려는 많은 노력이 이루어진다. 특히 반도체의 제조공정에서는 이를 위한 노력이 민감하게 발전되어 왔다. 이들 중 IC Test Handler의 Socket관리는 제품(Device)의 생산량과 함께 시스템의 효율성에 직접적인 영향을 주는 부분으로 많은 연구 및 개발이 이루어지고 있다. 본 논문에서는 이러한 생산성 및 효율성을 높이기 위한 자동 Socket 관리 시스템을 개발하여 사용자(Operator)에게 보다 향상된 시스템 환경을 제공하고자 한다. 이를 위해 PC 환경의 GUI 시스템을 도입하였으며, 실제적인 제어부분은 Real Time 운영체제를 탑재한 VME 시스템이 담당하였다. 또한, 신뢰성을 위하여 날짜별 데이터를 하드디스크에 저장하여 Socket 데이터를 사용자가 확인할 수 있도록 하였다.

  • PDF