• Title/Summary/Keyword: Test Socket

Search Result 119, Processing Time 0.026 seconds

The Measurement of Airtightness Performance of Multi-Family Housing (다가구 및 다세대 원룸주택의 기밀성능 실측연구)

  • Baek, Nam-Choon;Han, Seung-Hyeon;Lee, Wang-Je;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.117-121
    • /
    • 2014
  • Even though a study of airtightness performance of apartment and detached house have been done constantly, there are few of studies of multi-family housing which increasing every year. Therefore, this study analyzed airtightness performance of 20 households of one room in Daejeon to investigate airtightness performance standard. All experiments were performed under the same conditions except sealing windows to investigate airtightness performance without sealing windows (natural condition) and airtightness performance with sealing windows of studio apartment. As results, (1) average ACH50 without sealing windows was 19.2/h for pressurization, and 12.8/h for depressurization and (2) average ACH50 with sealing windows was 16.0/h for pressurization, and 10.7/h for depressurization and ACH50 in both condition, ACH50 under pressurization was about 50% higher than that under depressurization. Throughout this experiment, we can figure out that about 16% of air infiltration rate is occurred in windows, and the other 84% is occurred in rest of places such as Junction structure, socket and ventilating opening.

A study on the street security light management system using Zigbee network (지그비 통신망을 이용한 보안등 관제 시스템에 관한 연구)

  • Jeon, Joong Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.430-436
    • /
    • 2014
  • This paper relates to the study about the street security light management system. The purpose of the wireless remote management system is to manage street security lights efficiently. The system is composed of three components like light controller, CDMA gateway and web based remote management server. The zigbee solution is adopted to make local wireless network between street security lights. The CDMA network is used for the wireless communication between street security light controller and the remote control center. The gateway to interconnect zigbee network and CDMA was designed with low power 32 bits Cortex M3 micro-controller. For the data communication between the management server and the gateway, SMS and socket based TCP streaming is used. The management server sends SMS to the gateway to deliver light control and management requests, and the gateway replies with the light controllers report via TCP streaming. By using both SMS and TCP streaming communication, it was verified that simple cost effective management is possible for street security lights. We tried real test for 95 street security lights in real environment during two months and analyzed the practical possibility for mass supply.

The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets

  • Jun, Sang Ho;Park, Chang-Joo;Hwang, Suk-Hyun;Lee, Youn Ki;Zhou, Cong;Jang, Hyon-Seok;Ryu, Jae-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.8.1-8.6
    • /
    • 2018
  • Background: This study was to evaluate the effect of bone graft procedure on the primary stability of implants installed in fresh sockets and assess the vertical alteration of peri-implant bone radiographically. Methods: Twenty-three implants were inserted in 18 patients immediately after tooth extraction. The horizontal gap between the implant and bony walls of the extraction socket was grafted with xenografts. The implant stability before and after graft procedure was measured by Osstell Mentor as implant stability quotient before bone graft (ISQ bbg) and implant stability quotient after bone graft (ISQ abg). Peri-apical radiographs were taken to measure peri-implant bone change immediately after implant surgery and 12 months after implant placement. Data were analyzed by independent t test; the relationships between stability parameters (insertion torque value (ITV), ISQ abg, and ISQ bbg) and peri-implant bone changes were analyzed according to Pearson correlation coefficients. Results: The increase of ISQ in low primary stability group (LPSG) was 6.87 ± 3.62, which was significantly higher than the increase in high primary stability group (HPSG). A significant correlation between ITV and ISQ bbg (R = 0.606, P = 0.002) was found; however, age and peri-implant bone change were not found significantly related to implant stability parameters. It was presented that there were no significant peri-implant bone changes at 1 year after bone graft surgery. Conclusions: Bone graft procedure is beneficial for increasing the primary stability of immediately placed implants, especially when the ISQ of implants is below 65 and that bone grafts have some effects on peri-implant bone maintenance.

Examination on the Mounting Status of Cigar Lighter Receptacle for Vehicles and Analysis of its Tracking Characteristics (차량용 시가 잭의 장착 실태조사 및 트레킹 특성 분석)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.4
    • /
    • pp.28-33
    • /
    • 2009
  • This study examined the mounting status of cigar lighter receptacles for vehicles and analyzed the tracking phenomenon that occurs when foreign material entered a cigar lighter receptacle to obtain data for the analysis of accident investigation. Regardless of the vehicle's output, cigar lighter receptacles are mounted in a vehicle horizontally, vertically, or at tilting or inclined angle. The tilting type cigar lighter receptacle is much easier to use but current leakage resulting from foreign materials (coffee, beverages, water, etc.) falling into the cigar lighter receptacle may cause a fire to start. This study used a vehicle battery (DC 12V) as a power supply for the tracking test and configured its circuit in the same way as that of an electrical device in a vehicle. The tracking phenomenon that occurred in the standby mode of the vehicle exhibited a fine flame and an irregular occurrence of smoke. While this tracking phenomenon was occurring, the leakage current and the reaching distance of the flame were measured to be approximately 930mA and $20{\sim}50cm$, respectively. It is thought that the resultant flame may ignite toluene, dust, cigarettes, etc. It was observed that as the tracking progressed, the internal metal socket melted and a hole was created, the surface of which was also severely carbonized. In addition, the electrical resistance of the carbonized conductive path was measured to be approximately $30{\Omega}$. It is thought that this much resistance may cause local heating when leakage current flows and could ignite any nearby flammable material.

A Study on the Application of Zero Copy Technology to Improve the Transmission Efficiency and Recording Performance of Massive Data (대용량 데이터의 전송 효율 및 기록 성능 향상을 위한 Zero Copy 기술 적용에 관한 연구)

  • Song, Min-Gyu;Kim, Hyo-Ryoung;Kang, Yong-Woo;Je, Do-Heung;Wi, Seog-Oh;Lee, Sung-Mo;Kim, Seung-Rae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1133-1144
    • /
    • 2021
  • Zero-copy is a technology that is also called no-memory copy, and through its use, context switching between the user space and the kernel space can be reduced to minimize the load on the CPU. However, this technology is only used to transmit small random files, and has not yet been widely used for large file transfers. This paper intends to discuss the practical application of zero-copy in processing large files via a network. To this end, we first developed a small test bed and program that can transmit and store data based on zero-copy. Afterwards, we intend to verify the usefulness of the applied technology in detail through detailed performance evaluation

Combination of metal artifact reduction and sharpening filter application for horizontal root fracture diagnosis in teeth adjacent to a zirconia implant

  • Debora Costa Ruiz;Larissa de Oliveira Reis;Rocharles Cavalcante Fontenele;Murilo Miranda-Viana;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.3
    • /
    • pp.289-295
    • /
    • 2024
  • Purpose: This study examined the influence of metal artifact reduction (MAR), the application of sharpening filters, and their combination on the diagnosis of horizontal root fracture (HRF) in teeth adjacent to a zirconia implant on cone-beam computed tomography (CBCT) examinations. Materials and Methods: Nineteen single-rooted teeth (9 with HRF and 10 without) were individually positioned in the right central incisor socket of a dry human maxilla. A zirconia implant was placed adjacent to each tooth. Imaging was performed using an OP300 Maxio CBCT (Instrumentarium, Tuusula, Finland) unit with the following settings: a current of 8 mA, both MAR modes(enabled and disabled), a 5×5 cm field of view, a voxel size of 0.085 mm, and a peak kilovoltage of 90 kVp. Four oral and maxillofacial radiologists independently evaluated the CBCT scans under both MAR conditions and across 3 levels of sharpening filter application (none, Sharpen 1×, and Sharpen 2×). Diagnostic metrics were calculated and compared using 2-way analysis of variance (α=5%). The weighted kappa test was used to assess intra- and inter-examiner reliability in the diagnosis of HRF. Results: MAR tool activation, sharpening filter use, and their combination did not significantly impact the area under the receiver operating characteristic curve, sensitivity, or specificity of HRF diagnosis (P>0.05). Intra- and inter-examiner agreement ranged from fair to substantial. Conclusion: The diagnosis of HRF in a tooth adjacent to a zirconia implant is not affected by the activation of MAR, the application of a sharpening filter, or the combination of these tools.

A Study of Future Internet Testbed Construction using NetFGA/OpenFlow Switch on KOREN/KREONET (KOREN/KREONET기반 NetFPGA/OpenFlow 스위치를 이용한 미래인터넷 테스트 베드 구축 방안 연구)

  • Park, Man-Kyu;Jung, Whoi-Jin;Lee, Jae-Yong;Kim, Byung-Chul
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.7
    • /
    • pp.109-117
    • /
    • 2010
  • Building a large-scale testbed for Future Internet is very important to evaluate a new protocol and new network architecture designed by clean-slate approach. In Korea, new Future Internet testbed project, called FIRST (Future Internet Research for Sustainable Testbed), has been started since Mar. 2009 to design and test new protocols. This project is working together with ETRI and 5 universities. The FIRST@PC is to implement a virtualized hardware-accelerated PC-node by extending the functions of NetFPGA card and build a Future Internet testbed on the KOREN and KREONET for evaluating newly designed protocols and interesting applications. In this paper, we first briefly introduce FIRST@PC project and explain a 'MAC in IP Capsulator' user-space program using raw-socket in Linux to interconnect OpenFlow enabled switch sites on the KOREN and KREONET. After that, we address test results for TCP throughput performance for varying packet size. The test results show that the software based capsulator can support a reasonable bandwidth performance for most of applications.

A Study on the Properties Analysis of an Iron Fittings Type CSST Damaged by the PCITS (PCITS에 의해 소손된 강이음쇠형 CSST의 특성 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.121-127
    • /
    • 2016
  • This study analyzed the structural and electrical characteristics of an iron fittings type Corrugated Stainless Steel Tubing (CSST) damaged by the Primary Current Injection Test System (PCITS). CSST consists of cladding, tube, nuts, clamp ring, flare cap, socket, and ball valve. For an evaluation of the dielectric withstand voltage, the area between the live part and non-live part of the CCST shall withstand a voltage of 220 V AC for one minute. For an evaluation of the insulation performance by 500 V DC, it is required that the insulation exceed more than $1M{\Omega}$ before the temperature rise test, $0.3M{\Omega}$ after the test. Although the average resistance of the product was $11.5m{\Omega}$, that of the product damaged at a current of 130 A by the PCITS was $11.50m{\Omega}$. Furthermore, parts of the cladding were melted and black smoke appeared when a current of 130 A applied for 10 s. After 60 s, most parts were heated and turned red. At 120 s, the parts that turned red had widened. Although it did not form a normal distribution because the P value was 0.019 with a confidential interval of 95%, it revealed outstanding characteristics with an AD (Anderson-Darling) value of 0.896 and a standard deviation of 0.5573.

Motor Control IP Design and Quality Evaluation from the Viewpoint of Reuse (ICCAS 2004)

  • Lee, Sang-Deok;Han, Sung-Ho;Kim, Min-Soo;Park, Young-Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.981-985
    • /
    • 2004
  • In this paper we designed the motor control IP Core and evaluate its quality from the viewpoint of IP reuse. The most attractive merit of this methodology, so called IP-based hardware design, is hardware reuse. Although various vendors designed hardware with the same specification and got the same functional results, all that IPs is not the same quality in the reuse aspect. As tremendous calls for SoC have been increased, associated research about IP quality standard, VSIA(Virtual Socket Interface Alliance) and STARC(Semiconductor Technology Academic Research Center), has been doing best to make the IP quality evaluation system. And they made what conforms to objective IP design standard. We suggest the methodology to evaluate our own designed motor control IP quality with this standard. To attain our goal, we designed motor control IP that could control the motor velocity and position with feedback compensation algorithm. This controller has some IP blocks : digital filter, quadrature decoder, position counter, motion compensator, and PWM generator. Each block's functionality was verified by simulator ModelSim and then its quality was evaluated. To evaluate the core, We use Vnavigator for lint test and ModelSim for coverage check. During lint process, We adapted the OpenMORE's rule based on RMM (Reuse Methodology Manual) and it could tell us our IP's quality in a manner of the scored value form. If it is high, its quality is also high, and vice versa. During coverage check ModelSim-SE is used for verifying how our test circuits cover designs. This objective methods using well-defined commercial coverage metrics could perform a quantitative analysis of simulation completeness. In this manner, We evaluated the designed motor control IP's quality from the viewpoint of reuse. This methodology will save the time and cost in designing SoC that should integrate various IPs. In addition to this, It can be the guide for comparing the equally specified IP's quality. After all, we are continuously looking forward to enhancing our motor control IP in the aspect of not only functional perfection but also IP reuse to prepare for the SoC-Compliant motor control IP design.

  • PDF

Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading (새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력)

  • Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.151-155
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate screw removal torque of the two-piece zirconia abutment with the novel titanium component compared to the conventional one-piece titanium abutment in the internal connection implant before and after dynamic cyclic loading. Materials and methods: Two types of the abutment assemblies with internal connection were prepared and divided into the groups; titanium abutment-titanium abutment screw assemblies as control, and zirconia abutment-titanium socket-titanium abutment screw assemblies as experimental group. A total of 12 abutments and implants were used of six assemblies each group. Each assembly was tightened to 30 Ncm. A cyclic load of 300 N at an angle of 30 degrees in reference to the loading axis was applied until one million cycles or failure. The removal torque values (RTVs) of the abutment screws were measured with a digital torque gauge before and after cyclic loading. The RTVs of the pre load and post load were analyzed with t-test, and P-values < .05 were considered statistically significant. Results: The assemblies of both groups survived all after the dynamic cyclic loading test without screw loosening. The statistically significant differences were found between the mean RTVs before and after the cyclic loading in both groups (P < .05). The RTV differences for the control and the experimental group were $-7.25{\pm}1.50Ncm$ and $-7.33{\pm}0.93Ncm$, respectively. Statistical analysis revealed that the RTV differences in both groups were not significantly different from each other (P > .05). Conclusion: Within the limitation of this study, the two-piece zirconia abutment with the titanium component did not show a significant RTV difference of the abutment screw compared to the titanium abutment after dynamic cyclic loading.