• Title/Summary/Keyword: Test Site

Search Result 3,356, Processing Time 0.037 seconds

Evaluation of Piezocone Factors Applicable to Soft Ground Around Siwha Lake by Statistical Analysis (시화호 주변 연약지반 피에조콘계수 산정에 관한 통계적 분석)

  • Chung, Jin-Hyuck;Park, Soo-Beom;Lee, Song
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.4
    • /
    • pp.89-100
    • /
    • 2008
  • Applying graph and correlation developed in other countries to the domestic field has limits. Therefore, it is necessary that Piezocone factor should be determined by including ground characteristics obtained from various test results in the domestic site for better application. In this study, laboratory tests and field tests were performed to find the characteristics of soft ground which was widely distributed around Siwha lake. A comparative analysis of these tests with Piezocone penetration test was performed and the Piezocone factor was estimated by correlationship analysis of undrained shear strength and cone resistance. Also, an appropriate Piezocone factor in the study site was reestimated by utilizing statistical analysis method for deriving reliable result.

Analysis of Interoperability Test between a Different Kind of Train Control System (이종(異種) 열차제어시스템간의 상호운영성 시험 분석)

  • Baek, Jong Hyen;Seul, Nam-O
    • Journal of Korea Entertainment Industry Association
    • /
    • v.5 no.1
    • /
    • pp.122-126
    • /
    • 2011
  • In this paper, for the purpose of improving the future domestic train control systems and securing interoperability according to the global development trends of train control systems, we present the test results of interoperability between wayside train control system installed in existed line, and the onboard train control system. Due to the safety-critical characteristics of train systems, the site test in the section where the wayside equipment is installed, leads to a danger against safety. Therefore, by way of constructing a simulation environment of train control systems, we confirm the T/R data systems of the equipment for interoperability and test the interoperability by applying these systems to onboard equipment.

A Study of the Construction of Comprehensive Flight Testing Infrastructure to Increase Aviation Safety (항공안전 증진을 위한 비행종합시험 인프라 구축 방안 연구)

  • Kim, Seung-Han;Kim, Gyou-Beom;Yim, Jae-Hyun
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.9
    • /
    • pp.147-153
    • /
    • 2020
  • As demand for drone test flight is rapidly increasing, it is difficult for Goheung Aviation Center alone to meet the test flight demand. Newly developed drones or modified existing aircraft carry potential flight risks due to unpredictable flight performance or poor pilot skill when performing test flights outside the test site. Therefore, it is necessary to ensure sufficient test flight space for the safety verification of manned and unmanned aircraft. Therefore, this study analyzed the status of domestic flight test site and chapter 5 of ICAO DOC 9184-AN / 902 Part 1 (Airport Planning Manual). And to build a comprehensive flight test infrastructure, the methodology for preliminary evaluation of candidate sites for flight test sites and a method for evaluating infrastructure test sites was presented.

The Observation of the Skin Contact Allergic Sensitization Test of Rhus-II with Guinea Pig Maximization Test (Guinea Pig Maximization Test에 의한 옻나무 추출액(Rhus-II)의 접촉 알러지성 자극에 관한 연구)

  • Choi Changsun;Han Dong Un
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.1
    • /
    • pp.13-17
    • /
    • 2005
  • The purpose of the present study was to investigate differences in the sensitizing potential of Rhus Veniciflua(Rhus-II), when tested by the guinea pig maximization test(GPMT) and Freund's complete adjuvant test(FCAT) with an identical, intradermal induction concentration. A new grading classification of the sensitization potential is proposed. The GPMT was conducted according to OECD guideline $\#406$, using a multiple-dose design and test results were analysed with logistic regression analysis. During the induction stage, we injected intradermally each three site 0.1 ml(l mg/animal) test material, 0.1 ml complete Freund's adjuvant and 0.lml the test agent emulsified in the adjuvant. 7 days later, we induced weak sensitization with $10\%$ sodium lauryl sulfate(SLS) and applide 1ml(l0mg/animal) test agent topically on the same site and made a tight occlusion. 14 days later we challenged with 1 ml(l 0mg/animal) of test material on the flank and observed ant 24 hours and 48 hours later. The results were also observed $0\%$ at 24 hours challenge. The results observed 48 hours after challenge were the identical. These data indicated that, although Rhus-II is a no contact allergen. It was reported that the skin sensitization by Rhus-II was not detected the skin sensitization in the guinea pig maximization test (GPMT). Consequently, it was confirmed that Rhus-II had no contact allergic sensitization in guinea pig maximization test.

An Experimental Study of the Effect of the Test-well Arrangement on the Partitioning Interwell Tracer Test for the Estimation of the NAPL Saturation (지하수 유동 방향에 대한 관정배열이 분배추적자 시험에 미치는 영향 분석)

  • Kim, Bo-A;Kim, Yongcheol;Yeo, In Wook;Ko, Kyung-Seok
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.111-122
    • /
    • 2014
  • Partitioning interwell tracer test (PITT) is a method to quantify and qualify a site contaminated with NAPLs (Non-Aqueous Phase Liquids). Analytical description of PITT assumes that the injection-pumping well pair is on the line of the ambient groundwater flow direction, but the test-well pair could frequently be off the line in a real field site, which could be an erroneous factor in analyzing PITT data. The purpose of this work is to study the influence of the angle of the test-well pair on the ambient groundwater flow direction based on the result from PITT. From the experiments, it was found that the obliqueness of the test-well pair to the ambient groundwater flow direction could affect the tracer test resulting in a decreased NAPL estimation efficiency. In case of an oblique arrangement of the test-well pair to the ambient flow direction, it was found that the injection of a chase fluid could enhance the estimation efficiency. An increase of the pumping rate could enhance the recovery rate but it cannot be said that a high pumping rate can increase the test efficiency because a high pumping rate cannot give partitioning tracers enough time to partition into NAPLs. The results have a implication that because the arrangement of the test-well pair is a controlling factor in performing and interpreting PITT in the field in addition to the known factors such as heterogeneity and the source zone architecture, flow direction should be seriously considered in arranging test-well pair.

RELATIONSHIP BETWEEN DENTOCULT-SM TEST, MICROBIAL ANALYSIS AND DENTAL CARIES IN THE PRE-SCHOOL CHILDREN (미취학아동들의 유치우식경험도와 개량형 Dentocult-SM 검사 및 치면세균막 세균활성과의 관련성)

  • Shin, Doo-Kyo;Kim, Ji-Young;Song, Keun-Bae;Nam, Soon-Heyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.254-262
    • /
    • 2003
  • Dental caries has a multifactorial aetiology in which there is an interplay of three principal factors: the host(saliva and teeth), the microflora(dental plaque) and the substrate(diet), and a fourth factor time. There is no single test that takes into consideration all these factors and can accurately predict an individual's susceptibility to dental caries. The risk of dental caries can be evaluated by analysing and integrating several causative factors. The objective of the study was to clarify the relationship between caries activity and the status of caries of primary teeth and the relationship between the quantity of S. mutans in the dental plaque and the status of dental caries. Forty nine children ages 5 were examined with caries indices, Dentocult-SM and quantity of S. mutans. The results were as follows: All the survey results were similar with national means of 5-6 years Korean preschool children. The deft index of subjects was 5.46 and defs index was 9.81. There was 8.6% of negative, 10.9% of mild, 28.1% of moderate and 52.3% of active results at screening strip test. 8.6% was negative, 17.2% was mild, 33.6% was moderate and 40.6% was active in site strip test. The Spearman correlation coefficient was 0.775, and overall kappa index was 0.496 between screening strip test and site strip test. There also was a high correlation between caries incidence, Dentocult-SM test, and quantity of S. mutans. Dentocult-SM test as a caries activity test is a reliable method for measuring the status of dental caries in primary teeth.

  • PDF

Theoretical Curve of Classical Site Attenuation for Forced Resonant Type EMI Dipole Antennas (강제 공진형 EMI 다이폴 안테나에 대한 시험장 감쇠량 이론 곡선)

  • Ju Chang-Hyun;Park Eun-Jung;Kim Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.571-579
    • /
    • 2005
  • This paper presents the classical site attenuation characteristics of a forced resonant electromagnetic interference (EMI) dipole antenna for frequencies below 80 MHz. The coupled integral equations for unknown current distribution are solved by the Galerkin's method of moments with piecewise sinusoidal functions. The results show that the forced resonant type EMI dipole antenna for frequencies below 80 MHz can be used effectively for measuring the classical site attenuation of horizontal polarization. The theoretical site attenuation curves presented can be used as reference curves for evaluating the performance of an open area test site.

An Ecological Study on the Aquatic Animal Community in Tan Stream, Seoul (서울 탄천의 수서동물 군집에 관한 생태학적 연구)

  • 배경석;구본관;한선규;신재영;박성배
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.1-8
    • /
    • 1997
  • The aquatic animals of Tan stream were composed of 46 species, 28 families, 11 orders, 6 classes in 4 phyla during the survey period of April, 1996 to December, 1996. They were composed of 31 species in aquatic insecta, 6 species in annelida, 3 species in mollusca, 1 species in crustacea, and 5 species in fishes, respectively. Major dominant species in Tan stream were Chironomidae sp.1, Chironomidae sp.2, Chironomidae sp.3, Tubufucidae sp.1, Physa acuta and hirudo niponica. Dominance indices of benthic macroinvertebrates ranged highly from 95.74 to 100.00% at lower stream(site 4), but ranged 50.00 to 95.85% at site 1 through site 3. The aquatic animals ranged from 25 to 32 species at site 1 through site 3, but they were only 3 species at site 4 for survey period. Tan stream in the light of urban stream ecosystem has a little less riffle areas and hydrophyte areas by cementation of riparian area and channel type of water course. Therefore, the species of aquatic animals in Tan stream decreased because of deterioration of water quality according to reduction of self-purifcation ability and loss of microhabitat according to reduction of hydrophyte areas and riparian areas. The tendency of decreasing species of aquatic animals appeared seriously at lower stream From drive licence test authority at Kangnam-ku, Seoul to conjunction point of the Han river.

  • PDF