• Title/Summary/Keyword: Test Site

Search Result 3,367, Processing Time 0.033 seconds

Effects of EMLA Cream in Intradermal Skin Test of Ampicillin Sodium Antibiotics (EMLA 크림이 ampicillin sodium 항생제 피내반응검사에 미치는 효과)

  • Kim, Jin;Kang, Hee-Young
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.1
    • /
    • pp.46-53
    • /
    • 2011
  • Purpose: The purpose of this study was to identify the effects of EMLA cream (eutectic mixture of local anesthetics, lidocaine and prilocaine) on pain during ampicillin sodium intradermal (ID) skin test, and also to assess skin reaction after the skin test. Methods: Forty-three nurse-volunteers had skin tests with 0.01ml-0.05ml ampicillin sodium antibiotics. Skin tests were done on each forearm to compare the pain level of the skin test site after application of EMLA cream with the pain level when no EMLA cream was applied. EMLA cream was applied at the ID skin test site with an occlusive dressing for one hour. Pain was evaluated using a visual analogue scale and pain sensation using the short form McGill Pain Questionnaire. The transverse diameter of the wheal and redness was read right after and at 15 minutes after the skin test. The results were compared using independent t-tests. Results: Pain score and sensation with EMLA cream treatment were significantly lower than when EMLA cream was not applied. There was no difference in skin reactions; reading of the skin test was not affected by EMLA cream. Conclusions: EMLA cream was found to be an effective local anesthetic to relieve the pain of clients having ampicillin sodium antibiotics ID skin tests.

A Study on Concrete Material Quality Management Based on Various Test of Construction Condition under Hot Weather Circumstance (서중(暑中) 환경에서 현장 콘크리트 시험을 통한 재료 품질관리 방안)

  • Park, Shin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.3 s.17
    • /
    • pp.91-99
    • /
    • 2005
  • It is required to study systematical on the concrete quality management to extend structure life because rebuilding effect is reducing under present condition of large sized and high stories structure. Concrete, which shows its intensity by hydrating action and a big change in quality according to hot weather and temperature, produces a lot of qualify problem under hot and cold weather Because of each specification and construction plan which does not have basic standard on site, concrete's quality is irregular and makes some defect. As a result, Daegu is turned out to be the longest area after investigating application period and days focused on 8 cities weather information about relationship between hot weather circumstance and construction environment. Therefore, we first surveyed the concrete material in the region and found out the problem of quality nanagement. Then figure out the way of solution. Moreover, we integrated concrete material quality management, which is applied differently to each site, to have equal quality and to reduce defect from construction site. And then, based on various test of construction condition and analysis of quality management item, we suggest effective concrete quality management to make concrete material construction standard guide and plan under hot weather.

Development of Unmanned Seabed type Marine Cone Penetration Testing System (무인 착저식 해양 콘관입시험기 개발)

  • Jang, In-Sung;Kwon, O-Soon;Chung, Choong-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.611-622
    • /
    • 2007
  • In the design and construction of the coastal/offshore structures, it is very important to evaluate the geotechnical characteristics of marine soils, which support the structures. Although the offshore site investigation is much more difficult than onshore, safe and precise jobs have not been accomplished in Korea because of the insufficiency of the test equipments especially for the site with deep water depth. The main objective of this study is to develop a new type of marine cone penetration testing(CPT) system, which can be utilized to even deep sea and high depth of soil layer. The system is one of seabed types and employs the conventional cone, which shows more reliable results than miniature cone. The most important parts of the marine CPT including continuous rod system, cone penetration system with wheel drive, automatic cone rod assembly/dissembly system etc., were designed and manufactured. Some tests to verify the developed marine CPT system were performed at both onshore and offshore sites as well as mechanical test in laboratory. The test results show the consistent and promising performance of the new equipment, and thereafter the system would be applicable to various sites with practical/economical advantages.

  • PDF

[ $PERIOTEST^{(R)}$ ] ASSESSMENT OF DENTAL IMPLANT MOBILITY : A CLINCAL STUDY ($PerioTest^{(R)}$를 이용한 임플란트 동요도에 관한 임상적 연구)

  • Kim, Sun-Jai;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.5
    • /
    • pp.758-771
    • /
    • 1998
  • Assessment of implant mobility is an important and reliable method to clinically evaluate implant stability. PerioTest is a precise and reproducible device that cam dynamically measure the reaction of damping characteristics of peri-implant tissue. The aim of this study is to evaluate the effects of amount of implant surface area, diameter, type, implantation site, degrees of cortical engagement, and length of time in function on PTVs and to find out the most determining factor on PTVs. The results are as follows 1. 5.0mm diameter implants show significantly lower PTV than that of 3.75mm diameter implants. 2. PTV in the mandible is significantly lower than that of the maxilla 3. In the maxilla, there is no significant difference in PTV during the first year of implant function, but during the second year a significant decrease in PTV is noted. 4. In the mandible, there is a significant decrease in PTV during the first and second year of implant function. 5. Implantation site seems to be the most determining factor on PTV among the influencing factors in this study. In conclusion, the amount of implant surface area, type, degrees of cortical engagement had no significant effect on PTV, but installation site and diameter influenced significantly on PTV

  • PDF

Trend in Off-Line PD Monitoring with HVAC Testing (배전반 설비의 온라인 모니터링 및 진단의 동향)

  • Yun, Ju-Ho;Hong, Chang-Il;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.529-530
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

Comparison between Shear and Tensile Adhesion Strength of Cement for Ceramic Tiles and an Experimental Evaluation on the Cutting Effect of Tile for Tensile Adhesion Strength (타일 시멘트 전단접착강도와 인장부착강도 비교 및 인발부착강도 타일커팅 영향에 관한 실험적 평가)

  • Lee, Sang-Hyun;Ki, Jun-Do;Cho, Hong-Bum;Kim, Young-Sun;Moon, Hyung-Jae;Jeon, Hyun-Su
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.181-182
    • /
    • 2021
  • Selecting a proper tile cement for ceramic tile is important to secure tile construction quality. But there is some ambiguity in standards about evaluating adhesion test such as using KS L 1593 in Lab test but using KS L 1592 in site. So, this study aims to how to select proper tile cement for securing adhesion strength in site considering both tensile and shear adhesion strength of cement for ceramic tile. Also, when doing tensile adhesion test in site, there may be adhesion drop because of cutting tile with grinder. As a result, drop of adhesion strength is about 9% ans quality manager consider these factor and should select proper tile cement.

  • PDF

Soil Improvement using Vertical Natural Fiber Drains (연직천연섬유배수재를 이용한 연약지반 개량)

  • Kim, Ju-Hyong;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.4
    • /
    • pp.37-45
    • /
    • 2008
  • A pilot test using environmentally friendly drains, was carried out to evaluate their applicability potential in the field. The pilot test site was divided into 5 different areas, with several combinations of vertical and horizontal drains installed for evaluation. Conventional natural fiber drains (FDB), new developed straw drain board (SDB) and plastic drain board (PDB) were used as vertical drains, while sand and fiber mats were used as horizontal drains. Surface settlement rates and excess pore pressure generation/dissipation tendency of PDB and FDB are almost identical except those of SDB. Cone tip resistance obtained from cone penetration test measured at the end of 1st consolidation stage for upper soft layer definitely increased irrespective of types of vertical drains. The monitoring and site investigation test data obtained at the pilot test site prove the vertical natural fiber drains can be used as substitutes of conventional plastic and sand material.

  • PDF

Accuracy Evaluation of the Alternative Site Blood Glucose Test Using Error Grid (에러그리드를 사용한 대체부위 혈당검사의 유용성 검증)

  • Park, Kyung-Soon;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • Blood glucose information is important for self regulation in daily life, but the frequency of self test remains to be only 17%(9 tests/month) in Korea, mainly due to pain during blood sampling. The present study tried to validate the clinical efficacy of the forearm as an alternative sampling site with minimized pain. Capillary blood was sampled both on the index finger($G_F$) and the forearm($G_A$), immediately followed by glucose measurements in 531 subjects, 25 who visited the Health Enhancement Center of C University Hospital, then venous blood($G_V$) was sampled for glucose test. The blood glucose concentration measured on the forearm was closer to the venous glucose than on the finger. The mean difference between $G_V$and $G_F$ was only 10 mg/dL well within the internationally accepted error limit. Error grid analyses of $G_F-G_V$, $G_A-G_V$ and $G_A-G_F$ revealed that the number of data points in regions A and B took 100%, 99.8%, and 97.9%, respectively. These results demonstrate the forearm blood glucose test is not only accurate but also clinically valid. Therefore, the forearm blood glucose test can be a useful way of self managing the chronic diabetes with minimized sampling pain.

A Study on Skin Friction Estimation of Drilled Shaft Socketed in Weathered Granite by IGM's Theory (화강풍화암에 근입된 현장타설말뚝의 주면마찰력 산정에 대한 IGM 이론의 적용)

  • Hong, Soon Taek;Lee, Jong In;Shin, Young Wan;Lee, Seung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6C
    • /
    • pp.241-250
    • /
    • 2011
  • The design method of IGM proposed by FHWA to predict bearing capacities of drilled shaft socketed in weathered granite has been used generally. In this study, site investigations were performed in a pilot test site, and disturbance and roughness were measured. Geotechnical properties were assorted as cohesive material and undisturbed and smooth surface. A simple relationship was proposed to predict unconfined strength ($q_u$) of weathered granite using static load test results, load transfer test results and N values. It was confirmed that the design method to estimate bearing capacities of drilled shaft could improve IGM's theory for weathered granite from this research.

Characteristics of Anchor Behavior Resisting Buoyancy Forces in the Weathered Rock (풍화암에 시공된 부력저항 앵커의 거동특성)

  • Yoo, Nam-Jae;Lee, Gun-Chag;Jeong, Gil-Soo;Park, Byung-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.698-705
    • /
    • 2005
  • This study contains actual scaled site experiments on mediation factors affecting ultimate pulling force of the buoyancy resisting anchor which is installed underground water level suffering buoyancy force and breaking mechanism. Site buoyancy test selected the buoyancy acting site where acting buoyancy to the station structure since the stream and reservoir is neighboured to the vicinity ground and executed site experiments leading to variation of anchoring length, drilling diameter and tendon diameter at the weathered rock ground. The test result showed that pulling force getting increased more and more proportionate to increase of anchoring length, drilling diameter and tendon diameter, and as a result of analysis for correlations between anchoring length-ultimate limited load and drilling diameter-ultimate load (on the basis of 254mm settlement), modulus of correlation showed very high relation 0.9 and 0.99 respectively and correlation formular showed the limited load is increasing proportionate to cubic meters of anchoring length as well as the ultimate load proportionate to alignment of drilling diameter. It is also showed that limited load increased about 42.5% from 392kN to 559kN as a result of change the tendon diameter to 36mm and 50mm.

  • PDF