• Title/Summary/Keyword: Test Gases

Search Result 398, Processing Time 0.029 seconds

Conceptual Design of KSLV-II 3rd Stage Engine Test Facility (한국형발사체 3단 엔진 연소시험설비 개념설계)

  • Kim, Seung-Han;Chung, Yong-Gap;Han, Yeoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.484-488
    • /
    • 2012
  • Korea Aerospace Research Institute (KARI) performed the conceptual design of rocket engine test facility for the development and qualification of the 3rd stage liquid rocket engine for KSLV-II. The 3rd stage rocket engine test facility, which are to be constructed at Naro Space Center, will supply propellants and high-pressure gases to engine for firing test at ground and altitude conditions. The altitude test condition is obtained using a supersonic diffuser operated by the self-ejecting jet from the liquid rocket engine.

  • PDF

Experimental Study on Tensile Test Method of Pipe with Jig (파이프의 지그 삽입 인장시험법에 대한 실험적 연구)

  • Park, Jin-Gun;Song, Hyun-Jung;Jin, Da-Jeong;Kim, Ji-Hoon;Cho, Hae-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.5
    • /
    • pp.28-33
    • /
    • 2022
  • A pipe is a hollow, long-form part that is primarily used to transport fluids, such as liquids or gases. Pipes are used in a range of applications in different fields from mechanical purposes to architecture and electrical uses. Despite the significance owing to various usability of pipes, few studies have been conducted using the physical property test method. The tensile test is widely used as a method to check the physical properties of the pipe. The existing pipe tension test contains the possibility to cause errors, which are fractures outside the gauge distance and cross-sectional deformation of the pipe. In this study, a novel pipe tension test method using a jig is presented and pipes with various materials are tested. It is expected that the proposed method can reduce errors that occur in conventional pipes and also obtain more accurate values to enable more efficient testing.

Estimation on the Emission Reduction of SULEV LPG Vehicles (SULEV LPG 자동차의 배출가스 저감효과 평가)

  • Park, Jun-Hong;Lee, Jong-Tae;Kim, Sun-Moon;Kim, Jeong-Soo;Kang, Dae-Il;Lim, Yun-Sung;Han, Bo-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.68-76
    • /
    • 2012
  • SULEV (Super Ultra Low Emission Vehicle) which is one of the emission standards in Fleet Average System introduced to Korea from 2009 is known as the most severe standard to achieve with internal combustion engine. Considering low sales volume of hybrid vehicles in Korea, vehicle manufacturers are required to develop SULEV technologies for conventional gasoline and LPG vehicles to meet the future Fleet Average standard. In this study, the comparison of emissions has been made between SULEV developed and ULEV LPG vehicles mainly produced in this time. To estimate the emission reduction of SULEV vehicles, CVS-75 and NIER test modes have been used. CVS-75 has been used for emission certification of gasoline and LPG vehicles. NIER modes cover various average vehicle speed and reflect Korean real driving patterns better than CVS-75. The test results show that SULEV LPG vehicles have very high potential to reduce $NO_x$ in regulated emissions, $N_2O$ in green house gases and toluene in VOCs. However, SULEV LPG vehicles don't affect much on the reduction of CO and total green house gases.

Development of a Fission Product Transport Module Predicting the Behavior of Radiological Materials during Severe Accidents in a Nuclear Power Plant

  • Kang, Hyung Seok;Rhee, Bo Wook;Kim, Dong Ha
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.237-244
    • /
    • 2016
  • Background: Korea Atomic Energy Research Institute is developing a fission product transport module for predicting the behavior of radioactive materials in the primary cooling system of a nuclear power plant as a separate module, which will be connected to a severe accident analysis code, Core Meltdown Progression Accident Simulation Software (COMPASS). Materials and Methods: This fission product transport (COMPASS-FP) module consists of a fission product release model, an aerosol generation model, and an aerosol transport model. In the fission product release model there are three submodels based on empirical correlations, and they are used to simulate the fission product gases release from the reactor core. In the aerosol generation model, the mass conservation law and Raoult's law are applied to the mixture of vapors and droplets of the fission products in a specified control volume to find the generation of the aerosol droplet. In the aerosol transport model, empirical correlations available from the open literature are used to simulate the aerosol removal processes owing to the gravitational settling, inertia impaction, diffusiophoresis, and thermophoresis. Results and Discussion: The COMPASS-FP module was validated against Aerosol Behavior Code Validation and Evaluation (ABCOVE-5) test performed by Hanford Engineering Development Laboratory for comparing the prediction and test data. The comparison results assuming a non-spherical aerosol shape for the suspended aerosol mass concentration showed a good agreement with an error range of about ${\pm}6%$. Conclusion: It was found that the COMPASS-FP module produced the reasonable results of the fission product gases release, the aerosol generation, and the gravitational settling in the aerosol removal processes for ABCOVE-5. However, more validation for other aerosol removal models needs to be performed.

Experimental Research on Effects of Water Sprayed Curtain On Anti-diffusion of Fire Gases in Case of Tunnel Fire (터널 화재시 물분무노즐에 의해 형성되는 제연수막의 연기층 확산방지성능에 관한 실험적 연구)

  • Park, Hyung-Joo;Choi, Young-Sang;Jee, Nam-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.97-103
    • /
    • 2004
  • In case of a fire in road or railway tunnel it is always necessary to keep the escape condition as good as possible. Most of the victims of major fires in tunnels are because they couldn't leave the tunnel in time and were trapped by smoke, or rescue teams couldn't reach the place of the accident due to low visibility and high temperature. In spring 2003 a comprehensive field experiment was undertaken in a large scaled tunnel in Youngin City to test the effectiveness of a new water spray curtain system, designed to the air qualify inside of a tunnel in case of fire during passenger's escape to safe routes, In order to control the smoke propagation, fixed water sprayed nozzles were used to make water curtain system, which can be installed or hanging water piping line below ceiling. The experiment was accompanied by an extensive measurement campaign in order to measure temperature dropping effect and flow conditions as well as CO concentration for various water sprayed curtains produced by sprinkler heads or water spray nozzle. Eventually comparison analysis were undertaken to investigate the performance of water curtains under fixed water pressure. Therefore most effective water curtain system was presented on the basis of water droplet size in long tunnel.

Effects of Regular Inspection Facility Standards Improvement on Particulate Matter (PM10) Emissions (정기검사 시설기준 개선이 입자상물질(PM10) 배출에 미치는 영향)

  • Choi, Soungkyu;Kim, Yongdal;Lee, Jaeyoung;Kim, Hogyeong;Noh, Kiseong;Park, Jungsoo
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.1
    • /
    • pp.36-39
    • /
    • 2019
  • The particulate matter that was emitted always come up by atmospheric environmental problem. Running on the road vehicles must have regular inspection at regular period and make sure the emissions of exhaust gases exceed the legal standards. Emission test for the atmospheric environment, but it is not free from the particulate matter. Currently, emission test of vehicle inspection is divided into regular inspection and close inspection. Regular inspection and close inspection differ not only the method of emission test, but also the facility standards that must have for this inspection. According to the "Regulations on the Implementation of Comprehensive vehicle Inspection, etc.", close inspection must have trapping device that is trap particulate matter by emission test to vehicle. However, regular inspection is different. Regular inspection do not specify any criteria for trapping facilities. Therefore, this study is confirm how to prevent the emission of particulate matter to the atmosphere during the year when mandatory trapping facilities are required to trapped particulate matter in the regular inspection.

Production of Carbon Monoxide and Carbon Dioxide Gases in the Combustion Tests (연소 시험에서 발생하는 일산화탄소와 이산화탄소의 발생)

  • Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.7-13
    • /
    • 2015
  • This study was performed to test the production of combustion toxic gases by Pinus rigida specimens treated with various types of methylpiperazinomethyl-bis-phosphonic acid $M^{n+}$ ($PIPEABPM^{n+}$) and methylpiperazinomethyl-bis-phosphonic acid (PIPEABP). Three coats of 15 wt% $PIPEABPM^{n+}$ and PIPEABP solutions were applied to plates of Pinus rigida at room temperature. After drying the treated specimens, the production of combustion toxic gases was examined using a cone calorimeter (ISO 5660-1). The specimens treated with $PIPEABPM^{n+}$ showed lower carbon monoxide production ($CO_{2\;peak}$; 0.0136~0.0178% at 532~678 s) than the PIPEABP plates, except for the specimen treated with $PIPEABPFe^{3+}$. In addition, the peak carbon dioxide production ($CO_{2\;peak}$) was lower (0.03648~0.3648% at 373~433 s) than that of the PIPEABP-treated plate. Notably, oxygen production was much higher than 15%, which can be fatal to humans. Therefore, the resulting risk could be eliminated. The results indicate that the combustion toxicities were partially decreased due to treatment of the virgin plate with $PIPEABPM^{n+}$.

Permeation Behavior of Olefin/Nitrogen Gases through Siloxane based Polymeric Membranes (실록산계 고분자 막을 통한 올레핀/질소 기체 투과 거동)

  • 이수복;신효진;최승학;김정훈;박인준;노재성;강득주
    • Membrane Journal
    • /
    • v.13 no.4
    • /
    • pp.246-256
    • /
    • 2003
  • For the olefin recovery from polyolefin off-gas, the permeation behaviors of olefins and nitrogen were investigated through three kinds of PDMS membranes - cross-linked PDMS membranes, a polysiloxaneimide membrane, and oligo-PDMS modified PDMS membranes. Their pure gas permeabilities were measured as a function of operation temperature(-20 to $50^{\circ}C$) and pressure(1 to 25 atm) with ethylene($C_2\;H_4$), propylene($C_3\;H_6$), butylene($C_4\;H_8$), and nitrogen($N_2$) gases. The permeabilities of olefins and nitrogen highly depended upon the nature of PDMS membranes. Among these membranes, cross-linked PDMS membranes showed stable and high olefin/nitrogen selectivities over a wide operation pressure range and further study in various test conditions. Their permeability of olefin and nitrogen were governed by the condensation temperature(solubility selectivity) and plasticization, not the order of the size(diffusivity selectivity) of gases, which matched well with the general permeation behavior of rubbery polymeric membranes for condensable and non-condensable gases. With increasing feed pressure or decreasing feed temperature, the permeabilities of more condensible olefins increase highly, presumably due to high solubility and plasticization, but that of non-condensible nitrogen decreases slightly and thus, the selectivities of olefin/nitrogen increase highly.

Performance Test for the Performance Reliability of the Heat Pipe for Cooling Power Semiconductors (전력반도체 냉각용 히트파이프의 성능안정성 파악을 위한 성능시험)

  • 강환국
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.203-212
    • /
    • 2004
  • The heat pipe for cooling power semiconductor is required no performance changing during the life cycle up to 20 years. For the long reliable performance of the heat pipe, my reasons that has possibility to generate non condensable gases we not allowed. In this research, the maximum heat transport rate and operation characteristics that are related to various geometric and thermal conditions are carried out. Also the test items, specifications and methods to guarantee the long life cycle of the heat pipe for power semiconductor cooling device are provided and the tests are performed.

Development of HC Sensor & System for Vehicles Exhaust Gas Check (HC 센서를 이용한 자동차 배기가스 감지 연구)

  • Chon, Young-Kap;Cho, Kook-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1011-1014
    • /
    • 1999
  • An on-board monitoring system for an automobile emission gas has a test chamber remote from the automobile's engine exhaust gas stream: apparatus for supplying the chamber with sampled exhaust gases. A single hydrocarbon sensor exposed to the exhaust gas in the chamber to render a signal responsive to the hydrocarbon. The conductive ions in emission gas was checked by the HC sensor in test chamber. A preferred application includes hydrocarbons in an automotive exhaust gas stream by exposing a transition porous alumina($Al_{2}O_{3}$) ceramic based sensor to the same exhaust gas stream. By combining the electrical signal, a measure of hydrocarbons can be provided.

  • PDF