• Title/Summary/Keyword: Test Equipments

Search Result 744, Processing Time 0.03 seconds

Hydraulic Experiments on the Measuring Equipments of Ronoff and Soil Loss (유출수 및 유실토량 측정장치에 관한 수리시험)

  • 유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.10 no.1
    • /
    • pp.1377-1387
    • /
    • 1968
  • In order to measure runoff and soil losses produced in a small test plot during rainfall, it is usually insufficient to use a tank only, necessitating the combined use of a main tank and a subsidiary tank. Accordingly. exact measurement largely depends on how to connect those two measuring tanks. The main purpose of this thesis is to improve the connecting parts of two measuring tanks so as to assure exact measurement of runoff and soil losses. In this experiment, two types of main tank, i. e. A-type and B-type, were used. A-type is a square tank having a flume at its end. At the flume, ten apertures are provided by using metal columns so as to be able to catch one tenth of total muddy flow discharging at the end of the flume, One tenth of total flow is led to the subsidiary tank through a slot sampler fixed to an aperture. B-type differes in that its flume does not have apertures and slot sampler is fixed directly to the end of the flume, other features being the same as those of A-type. Discharge volumes were measured by using weighing tanks and compared. The effect of baffle screen provided in the flume was also observed in connection with exact measurements. In order to keep main tank and its flume in a horizontal position, bolts and nuts mechanism was used. Vertical and horizontal screens were provided in the main to prevent coarse sands coming into the flume. The conclusion derived through this experiment is as follows: (1) The discharge through slot sampler at each aperture is almost the same for A-type. However, it is slightly more than one tenth of total discharge volume. (2) In case that baffle screen is provided in the flume of A-type tank, the discharge volume of slot sampler is less than that of the same type without screen. (3) For B-type tank, slot sampler discharge increases as slot sampler nears toward the center of flume. (4) When baffle screen is provided in the flume of B-type, slot sampler discharge is less than that of the same type without screen, and this phenomenon is more apparent as compared with A-type. (5) In case that the slot width of slot sampler for B-type is one inch, slot sampler discharge exceeds one tenth of total discharge volume. (6) When the slot width for B-type is 15/16 inch and slot sampler is fixed 3/8 inch apart from either flume wall, slot sampler discharge is approximately equal to one tenth of total discharge volume.

  • PDF

Evaluation on HACCP prerequisite-program performance within general hospital foodservice operations (종합병원 급식소의 HACCP 선행요건 관리 수행도 평가)

  • Song, Yoon-Ji;Bae, Hyun-Joo
    • Journal of Nutrition and Health
    • /
    • v.49 no.1
    • /
    • pp.43-50
    • /
    • 2016
  • Purpose: This study was conducted to examine prerequisite-program performance of the hospital foodservice operation and develop measures for improvement of prerequisite-program performance. Methods: Data were collected through surveys administered to 168 hospital dieticians in the Seoul, Incheon, Gyeonggi-do, Daegu, and North Gyeongsang areas. Out of total questionnaires, 65 questionnaires were usable and the response rate was 38.7%. Statistical analyses were performed using the SPSS program (ver 20.0) for ${\chi}^2-test$ and one-way ANOVA. Results: According to the result of the prerequisite-program evaluation, the percentage of 'appropriate', 'needs to be improved', and 'inappropriate' was 44.6%, 47.7%, and 7.7%, respectively. The score for the 'inappropriate' group was significantly lower than that of the 'appropriate' group or 'needs to be improved' group on the food safety management (p < 0.001), preparation facility management (p < 0.001), water management (p < 0.001), and storage transportation management (p < 0.05) parts. Holding rate of foodservice facility and equipments in the 'appropriate' group were significantly higher than in the others on convection oven (p < 0.01), air conditioner (p < 0.01), three-compartment sink (p < 0.01), hot-holding equipment (p < 0.01), cold-holding equipment (p < 0.05), exclusive thawing refrigerator (p < 0.05), and sterilizer for sanitary shoes (p < 0.05) items. Conclusion: To improve the quality of hospital foodservice, foodservice managers and HACCP specialists should develop and implement a prerequisite-program and a HACCP plan considering the characteristics of the hospital foodservice operation.

Evaluation of the Characteristics of Asphalt Release Agents (국내 아스팔트 릴리스 에이전트의 특성 평가)

  • Kim, Boo-Il
    • International Journal of Highway Engineering
    • /
    • v.9 no.2 s.32
    • /
    • pp.13-25
    • /
    • 2007
  • Viscosity, adhesion and cohesion of asphalt binder are very important characteristics in asphalt pavement. However, these characteristics can cause some problems such as inaccurate amount of asphalt mixture, reduction of asphalt content and loss of workability during asphalt pavement construction. Asphalt release agent has been used to solve these problems. Diesel oil and vegetable oil are generally used as an asphalt release agent in Korea. However, these agents have been criticized from environmental and binder integrity reasons. Therefore, this study evaluated the characteristics of asphalt release agents including diesel oil, vegetable oil and two emulsion type oils. From the study, it was found that the diesel oil resolved the binder within ten minutes and vegetable oil stripped the binder from mixture within one hour after contacting with asphalt mixture. And also, from the test for estimating the application cycle of asphalt release agent, it appears that diesel oil and vegetable oil should be applied to construction equipments every time in their uses. However, diesel oil and vegetable oil showed a good performance as a lubricant for detaching the asphalt mixtures from the truck bed.

  • PDF

A Study on Color Difference Discrimination for PVC Deco-Film using Entry-Level Digital Device (보급형 디지털 장비를 이용한 Deco-Film용 PVC의 색차판별에 대한 연구)

  • Im, Hoyoun;Kim, Minsoo
    • The Journal of Society for e-Business Studies
    • /
    • v.22 no.1
    • /
    • pp.1-13
    • /
    • 2017
  • Though digital imaging devices such as smart phones, digital cameras and office scanners have improved significantly over the past years, they are seldom used for industrial application. This may be attributable to high level of quality and performance requirement for industrial application, but there lacks a test or an objective evaluation whether the upgraded performance of entry-level device is sufficiently enough to replace existing industrial equipments or not. If there exists an industrial application area where the applicability of entry-level equipment is proved by some objective tests, then companies will be able to reduce investment on expensive industrial equipment. In this study, applicability of entry-level digital devices for color difference discrimination of PVC (Polyvinyl chloride) color sheet is tested. By testing smart phone, digital camera, and office scanner for color difference discrimination, authors have found that office scanner shows consistent result with less measurement error. Additional experiment on comparing office scanner with industrial spectrophotometer has confirmed that there exists high correlation between the two devices' results. Based on this result, office scanner may be applicable to discriminate the color difference of PVC sheet instead of expensive industrial spectrophotometer if proper management criteria are established.

Fabrication and characterization of boron free E-glass fiber compositions (붕소를 함유하지 않는 E-glass fiber의 제조 및 특성에 대한 연구)

  • Lee, Ji-Sun;Lim, Tae-Young;Lee, Yo-Sep;Lee, Mi-Jai;Hwang, Jonghee;Kim, Jin-Ho;Hyun, Soong-Keun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.1
    • /
    • pp.44-50
    • /
    • 2013
  • E-glass fiber is the most widely used glass fiber for reinforced composite materials of aircrafts, automobiles and leisure equipments. But recently researches are being progressed to reduce boric oxide from 8 % to 0 (zero), as is called 'Boron free E-glass', because of increasing material cost, environmental problem, and improving chemical resistance and mechanical properties of E-glass fiber. In this study, we fabricated the bulk glass and fiber glass of 'Boron free E-glass (BF) compositions', and characterized thermal properties and optical properties. 'Boron free E-glass (BF)' was obtained by the melting of mixed batch materials at $1550^{\circ}C$ for 2 hrs with different $Al_2O_3$ compositions 5~10 %. We obtained transparent clear glass with high visible light transmittance value of 81~86 %, and low thermal expansion coefficient of $4.2{\sim}4.9{\times}10^{-6}/^{\circ}C$ and softening point of $907{\sim}928^{\circ}C$. For the chemical resistance test of 'BF' fiber samples, we identified that the higher alumina contents gives the better corrosion resistance of glass fiber.

240 channel Marine Seismic Data Acquisition by Tamhae II (탐해2호의 240채널 해양탄성파 탐사자료취득)

  • Park Keun-Pil;Lee Ho-Young;Koo Nam-Hyung;Kim Kyeong-O;Kang Moo-Hee;Jang Seong-Hyung;Kim Young-Gun
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.2
    • /
    • pp.77-85
    • /
    • 1999
  • The 3-D seismic research vessel, Tamhae II, was built to raise up the probability of the hydrocarbon discovery in the Korean continental shelf and the first test survey was completed in the East Sea. During the survey, the 240 channel 2-D marine seismic data were acquired by the Korean flag vessel for the first time. Tamhae II has been equipped with source, receiver, recording equipment, and navigation equipment as well as an onboard processing system. The source is composed of four subarrays and each subarray has six airguns. Total airgun volume is 4578 $in^3$. The receiver consists of two sets of 3 km long 240 channel streamer. In the first survey, the successful acquisition of 2-D seismic data was accomplished. From the result of the data processing, we confirmed that the high quality seismic data were acquired. For the high quality data acquisition, technology of survey design and planning, operation of vessel and equipments and systematic quality control should be developed.

  • PDF

ULTRASTRUCTURAL STUDY FOR VEIN REGENERATION AFTER MICROVASCULAR ANASTOMOSIS IN RABBIT FEMORAL VEIN (가토 대퇴정맥 미세정맥문합술 후 정맥 문합부 재생에 관한 미세조직학적 연구)

  • Rho, Hong-Seop;Kim, Chul-Hwan;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.340-349
    • /
    • 2007
  • Free flap transplantation with microvascular anastomosis has been successfully performed by development of surgical technique, materials and postoperative monitoring equipments of flap. But success rate of microvascular anastomosis is influenced by various factors, and failure rate is about 5-10%. The most influential factor for success rate is surgical technique and other factors that influence failure of microvascular anastomosis are ischemic time of free flap, thrombus formation of anastomosis region and vascular spasm. In this study, vascular patency and thrombus formation in experimental micro-venous anastomosis, and endothelial repair were observed with histologic analysis, scanning electron microscopy, transmission electron microscopic examination. The results were obtained as follows: 1. In vascular patency test in 30 minute and 7 days after micro-venous anastomosis with heparin irrigation, all of 12 anastomosis site were good vascular patency. 2. In thrombus formation in 2 weeks group(Experimental I), 2 site of 6 cases were observed thrombus, and in 4 weeks group(Experimental II), 1 site of 6 cases were observed thrombus. 3. In histologic examination, normal vein(Control Group) showed continued internal elastic lamina, well formed thick smooth muscle layer and connective tissue. The group of 2 weeks after microvenous anastomosis(Experimental I) showd locally recovered internal lamina, discontinued internal lamina, disorganized smooth muscle cells and granulation tissue around suture silk. In the group of 4 weeks after micro-venous anastomosis(Experimental II), anastomosis site showed almostly continued internal lamina, disorganized smooth muscle cells and cicartrized tissue around suture silk. 4. In scanning electron microscope examination in 2 weeks(Experimental I) after micro-venous anastomosis, mesh fibrin formation showed near to endothelial cells, and in 4 weeks after micro-venous anastomosis(EXperimental II), numerous blood cells and fibrin mesh formation was seen associated with irregular endothelial cell arrangement. 5. In transmission electron microscope examination in 2 weeks after micro-venous anastomosis(Experimental I), irregular arrangement of smooth muscle cells was seen adjacent to collagenized tissue around suture silk. In 4 weeks after micro-venous anastomosis(Experimental II), denuded venous wall composed of relatively well arranged smooth muscle cells was covered by endothelial cells, but fibroblast cells and foreign body giant cells near to suture silk was remained. From the results obtained in this study, results of good vascular patiency and anti-thrombotic effect of heparin were obtained as a local irrigation solution, and repair of venous endothelial cell was observed in 2 weeks after micro-venous anastomosis.

A Study on Activation of Oriental Medicine in Public Health Sector : The role of Oriental Public Health Physicians (한방 공공의료의 활성화에 관한 연구 - 공중보건 한의사의 활동을 중심으로 -)

  • Yi Sang-Gu;Moon Ok-Ryun;Piao Song-Lin;Lee Shin-Jae;Yoon Tae-Ho;Jeong Baek-Geun;Wen Yong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.4 no.1
    • /
    • pp.1-16
    • /
    • 2000
  • From 1998, Oriental Medical Physicians(OMP) is distributed in Public Health Sector. but long term plan for Oriental Medicine in Public Health is not existed. So, this study is designed for the activation of OMP Subjects in this study were comprised 3 groups of oriental medicine related persons, the group of which are Students of 11 Oriental Medical Schools, Oriental Medical Physicians in Public Health Sector, Specialist Croup of Oriental medicine Policy(total 1,458 persons). Data were collected from July 1st to November 30, 1999. Direct interview with key persons, systematic interview by using of interview protocol, e-mail and facsimile have been conducted. The results of survey were coded by Excel 5.0, and analysed with SAS 6.12 statistical package. Inter-group difference determined by T-test, and descriptive statistics have been examined. Major findings can be epitomized as follows. 1) OMP disposition to multifarious organizations and institutes such as Public Health Centers, Public Health Sub-centers, Public Hospitals, Private Hospitals in Remote-Vulnerable Area, Community Social Welfare Centers, Institutes for Heath Policy Research, etc, will promise an effective use of Oriental Medical Physician. 2) Average number of patients treated by OMP was 22.8, average budget for oriental medical department, in which OMP were affiliated, was 39.6 million Won per year. Direct cost per every patient visit was 7,210.9 Won, which is considered expensive for public health service. Therefore, development and transformation for Oriental Medical Service in Public Health Sector is desirable in economic and political aspects. 3) It is recommended that ${\ulcorner}Advisory\;Committee{\lrcorner},{\ulcorner}Planning\;Commission\;for\; Public\;Health\;in\;Oriental\;Medicine{\lrcorner}$ should be established for the activation and for the support of Oriental Medical Physician in Public Health Sector, 4) Most effective programmes for oriental public health doctor are health service programmes for the elderly, Home health visit, chronic degenerative disease control services(p<0.001). 5) Standard guideline for facilities and equipments of Oriental Medicine Department in Public Health Center is needed for optimal supply of resources and activation of public health activity.

  • PDF

Evaluation of Nutrient Intakes in the Hemodialysis Patients According to the Socioeconomic Status - In Daejeon and Chungnam Areas - (혈액투석환자의 사회경제적 수준에 따른 영양소 섭취상태의 평가 - 충남지역을 중심으로 -)

  • Chung, Young-Jin;Park, Yoo-Sin;Kim, Han-Sook;Chang, Yu-Kyung;Kim, Chan
    • Journal of Nutrition and Health
    • /
    • v.35 no.5
    • /
    • pp.544-557
    • /
    • 2002
  • This study was performed to evaluate the quality of nutrient intakes of the hemodialysis patients (26 men and 23 women) according to the socioeconomic status by 3-day dietary recall in Daejeon city and Chungnam area, Korea. Mean age of the subjects was 50.7 yrs and BMI was 22.0 $\pm$ 0.4 kg/$m^2$. Education level was divided into two groups ($\leq$ 9 years: LE group, 9 years: HE group), and monthly family income level was divided into three groups (< 500,000 won: LI group, 500,000-1,499,999 won: MI group, $\geq$ 1,500,000 won : HI group). The data were analyzed by Student t-test and Oneway ANOVA using SPSS 9.0 version at p < 0.05 level. Intakes of energy, carbohydrates, cholesterol, potassium, thiamin and riboflavin were significantly higher in HE group than in LE group (p < 0.05). Intakes of all the nutrients except protein and phosphorus were less than Korean RDA, and INQs (Index of Nutritional Quality) of most nutrients were lower than 1.0 but cholesterol, phosphorus. thiamin and niacin being over 1.0 in HE group. MAR (Mean adequacy ratio) of all the nutrients (e.g., energy, protein, calcium, phosphorus, iron, vitamin A, vitamin C, thiamin, riboflavin and niacin) was significantly higher in HE group (0.61 $\pm$ 0.04) than in LE group (0.48 $\pm$ 0.03) at p = 0.036. Intakes of energy, protein (total, animal and plant), fat, cholesterol, potassium, calcium, phosphorus, iron, vitamin A, thiamin and riboflavin were also significantly higher in HI group than in LI and MI group (p < 0.05). Daily intakes of most nutrients were less than Korean RDA except protein ed phosphorus in HI poop, and INQs of thiamin, niacin and phosphorus were higher than 1.0, while those of calcium, iron, vitamin A and riboflavin were lower than 1.0. MAR of energy and 9 nutrients was significantly higher in HI group (0.70 $\pm$ 0.04) than in LI group (0. 56 0.04) and MI poop (0.47 $\pm$ 0.03) at p = 0.000. In conclusion, quality of nutrient intakes, especially energy and protein, was significantly influenced by socioeconomic status such as education and monthly income (p < 0.05). This result suggests that it would be very helpful to develop nutritional education programs considering hemodialysis patients' education levels, and to improve public supports (e.g., medical insurance system, low-rate lease system of dialysis equipments, etc.) focusing on the patients' family income levels f3r their better nutrition and health.

A Study on Comparison of Massive Data Recording Equipments for VLBI Radio Observation Data (VLBI 전파 관측데이터를 위한 대용량 기록장치 비교에 관한 연구)

  • Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Jung, Dong-Kyu;Hwang, Ju-Yeon;Oh, Chungsik;Kim, Hyo-Ryoung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.125-132
    • /
    • 2018
  • KVN(Korean VLBI Network) introduced the Mark6 system of the MIT haystack observatory as a recorder for data recording up to 32 Gbps for VLBI(Very Long Baseline Interferometry) observation. The Mark6 recorder can record data at up to 32Gbps when two systems and 64 HDDs are installed. However, because of the unique recording method that is characteristic of Mark6, we are introducing a large amount of data into a virtual file system, or using a general RAID method, which causes data loss when reading and transferring files at the highest recording speed or file system have. The Flexbuff system, a software recorder developed by JIVE(Joint Institute for VLBI ERIC), can be configured to operate as a data recorder through RAID configuration and network upgrades. In particular, when installed in the Mark6 system, it can record VLBI data at a maximum speed of 32 Gbps with less loss of data compared to the existing Mark6 by utilizing Mark6 resources well. In this paper, we propose that the existing Mark6 system can be operated as Mark6-Flexbuff by installing jive5ab software, and it is verified through experiment that it can be effectively used for VLBI observation operation through data recording test.