Bond Characteristics of Reinforcing Bars Embeded in High Strength Concrete (고강도 콘크리트에 매립된 철근의 부착특성)

  • 최종수;유석형;안종문;이광수;신성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.319-324
    • /
    • 1994
  • Bond test was carried out to assess the effect of several variables on bond characteristics between reinforcing bar and concrete. Key variables are concrete compressive strength(low, medium high, and ultra-high), bar diameter(13mm and 22mm), and concrete cover(25mm; 1-inch, 38mm; 1.5-inch, and 51mm; 2-inch). Confining effect and bar spacing are not taken into account. Thirty-two specimens subjected to uniaxial tension were tested under hypothesis uniform bond stress distribution along the reinforcing bar embeded in concrete. Test results(ultimate bond stress) were compared with bond and development provisions of the ACI building Code(ACl 318-89) and local bond stress versus slip relationship diagram represented to show effect of the above variables.

  • PDF

Uniaxial bond stress-slip behavior of reinforcing bars embedded in lightweight aggregate concrete

  • Tang, Chao-Wei
    • Structural Engineering and Mechanics
    • /
    • v.62 no.5
    • /
    • pp.651-661
    • /
    • 2017
  • This paper presents an experimental study of bond-slip behavior of reinforced lightweight aggregate concrete (LC) and normal weight concrete (NC) with embedded steel bar. Tests were conducted on tension-pull specimens that had cross-sectional dimension with a reinforcing bar embedded in the center section. The experimental variables include concrete strength (20, 40, and 60 MPa) and coarse aggregate type (normal-weight aggregate and reservoir sludge lightweight aggregate). The test results show that as concrete compressive strength increased, the magnitudes of the slip of the LC specimens were greater than those of the NC specimens. Moreover, the bond strength and stiffness approaches zero at the loaded end, or close to the central anchored point of the specimen. In addition, the proposed bond stress-slip equation can effectively estimate the behavior of bond stress and steel bar slipping.

High strain rate tensile test of sheet metals with a new tension split Hopkinson bar (박판의 고변형률에서의 기계적특성을 얻기위한 Tension Split Hopkinson bar의 제작 및 실험)

  • Jung, Dong-Taek;Huh, Hoon;Kang, Woo-Jong;Cho, Sang-Soon
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.106-110
    • /
    • 1997
  • A split Hopkinson bar has been used for obtaining material properties in high strain rate state, In this paper, the apparatus was modified to obtain the high strain rate properties of sheet metal for an autobody. From the experiments with the new apparatus, the material properties of SPCEN in the high strain rate state have been acquired and compared with quasi-static experimental results.

  • PDF

Connection Apparatus using Coupling Device and Linking Method for Reinforcing Bar (철근연결구를 이용한 철근이음장치(LK-DK) 개발에 관한 연구)

  • Woo, Jong-Yeol;Hong, Seong-Wook;Park, Seung-Hwan;Ann, Tae-Han;Choe, Min-Kwon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.175-176
    • /
    • 2012
  • In this study, coupler on the safety of meeting the requirements and construction and economy to satisfy the number of parts to minimize an LK-DK coupler has been developed, affordability existing reinforcing bar joint, welded joint, mechanical joints, compared with a favorable one to the understanding, and also facilitate the construction and logistics, etc. I've found that there is no additional pay because the amount of product performance through the tensile test after test, if commercialization is expected to be greater ramifications.

  • PDF

Experimental Study of Bond Properties Using Coated Bars (도막재료에 따른 철근의 부착성능에 관한 실험적 고찰)

  • 김영진
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.211-216
    • /
    • 2003
  • Coated bars are protecting reinforcing bars from corrosion and enhancing durabilities of reinforced concrete structures are tested to evaluate corrosion protection properties. Tests are performed based on the relevant standards of ACI and ASTM, such as chemical resistance, salt water spray, salt crack test and chloride permeability test with the main variable of the coating thickness. Three type materials are tested by Polyethylene, epoxy and bare bar. Test results show good chemical protection property and chloride permeability. Polyethylene coated bar is good coating material than any other materials.

  • PDF

FE simulation for the Reconstruction of Deceleration Profile in Steel Bar Breaking System (강철봉 제동 시스템에서의 감속파형 재현을 위한 유한 요소 해석)

  • Lee, J.K.;Suk, H.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.213-216
    • /
    • 2008
  • Sled test id widely used to evaluate the performance of occupant's safety system in frontal crash environment without having to conduct a full-scale crash test. Steel bar breaking system is used to generate deceleration profile which is experienced by passengers in frontal crash. In this study, deformation analyses of steel bars were conducted using a commercial FE code. Several guidelines were proposed to improve the accuracy of simulation.

  • PDF

A Study on the Characteristics of Direct Tensile Fatigue of the Domestic PS Bar at High Stress Range (국산 PS 강봉의 고응력범위에서의 직접 인장피로 특성)

  • Yoo, Sung Won;Suh, Jeong In
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.2
    • /
    • pp.137-145
    • /
    • 2003
  • In this study, direct tensile fatigue tests of the PS bar were performed in terms of diameter, minimum stress level, and maximum stress level. In the static test, the stress - strain curve and ultimate streng th of the PS bar were determined. Results of the fatigue test indicate that the diameter of the PS bar was not influenced by fatigue life. Minimum stress also had quite an influence on the fatigue of the PS bar. Thus, the fatigue characteristic equation was proposed in terms of stress range and minimum stress through statistical process. Strains on specimen that loaded direct tension were measured in the fatigue test, with the secant modulus of elasticity calculated from measured strains. The strain development consisted of three different stages, i.e., rapid increases during the initial fatigue life, uniform increases during the middle stage, and rapid increases until failure. The secant modulus of elasticity decreased during the fatigue life with increasing strain. However, stress level seemed to have no influence on the secant modulus of elasticity.

An Experimental Study on Flexural Behavior of RC Beams Strengthened with Hi-Strength Bars(3) (고장력 인장봉으로 보강된 RC 보의 휨 거동에 관한 실험적 연구(3))

  • Shin, Kyung-Jae;Kim, Yoon-Jung;Moon, Jeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.351-358
    • /
    • 2007
  • Unlike external bonded steel plate or carbon fiber, the external unbonded strengthening using hi-strength bar has some advantages in speed and simplicity of installation. It is not required surface preparations and not affected by environmental conditions. A set of nine laboratory tests on RC beams strengthened using the hi-tension bars are reported. Anchoring pin developed in former research is installed at the end of beam to connect the hish-tension bar to RC beam. The test results strengthened by hi-tension bars are compared with those of non-strengthened specimens. The main test parameters are the cross-sectional area of the high-tension bar, distance of stirrups and condition of supports. Test results show that the beams reinforced are superior to reference specimens, especially for the strength and deformation capacity. Also, shear resisting effect of hi-strength bar can be confirmed in the specimens which have lack of stirrups.

Experimental Study on Shear Strength of Concrete Deep Beam Reinforced FRP Bars (FRP Bar로 보강된 콘크리트 깊은보의 전단강도에 관한 실험적 연구)

  • Cho, Jang-Se;Kim, Min-Sook;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.1
    • /
    • pp.23-31
    • /
    • 2011
  • This study carried out shear experiment for concrete deep beam reinforced FRP(Fiber Reinforced Polymers) bar to investigate shear strength of deep beam. The test conducted for 15 specimens, and the variables were shear span-to-depth ratio, reinforcement ratio, effective depth, reinforcement components of shear strength. crack, deflection are investigated based on shear experimental. We compared shear strength using ACI 318-08 STM with proposed equations that considered arching action according to shear span-to-depth ratio. Consequently shear strength of deep beam reinforced FRP bar presented higher shear strength than steel bar. ACI STM's predictions are better accurate than other predicting equations.

An Experimental Research on the Flexural Behavior of Concrete Beams with Lock Joint Coupler Bars (커플러 이음 철근을 사용한 철근콘크리트 보의 휨 거동에 대한 실험적 연구)

  • Park, Sun-Kyu;Lee, Kwal;Ko, Won-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.3
    • /
    • pp.197-204
    • /
    • 2000
  • Tensile strength (stress) of bar splice is important in the research of mechanical behavior of reinforced concrete structures-beam, column etc.- with bar splice. The purpose of this research is to evaluate the flexural behavior - deflection of beam specimens, strain of main bars - of reinforced concrete beam with Lock Joint Coupler. To make a comparative research, reinforced concrete beam specimens with normal deformed bar and lap splice are tested and analyzed. Test results, Comparing a deflection of three types flexural specimens, a flexural specimen with Lock Joint Coupler is 40% greater than the other flexural specimens. At the center of flexural specimen, the strain of main bar(D29) with lock joint coupler is 50% less, and vice versa, at the point of 14cm far from the center of flexural specimen, the strain of main bar(D29) with lock joint coupler is 9% larger than the strain of main bar(D29) which calculated using the classical flexure theory. A discords, between a deflection behavior of the flexural specimens and a strain of the main bar, are caused by the difference of strain between the lock joint coupler and main bar, near the lock joint coupler. So, additional research is need to verify as stated above discords.

  • PDF