• Title/Summary/Keyword: Test Accuracy

Search Result 4,922, Processing Time 0.036 seconds

Characteristic Test of High Force Linear Motor Feed Unit for High Speed Machine Tool (고속가공기용 고추력 리니어모터 이송계의 특성 평가)

  • 송창규;황주호;박천홍;이후상;정재한
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.977-981
    • /
    • 2000
  • Direct drive linear motors have large potential for use as high speed machine tool feed units since they can increase machining rates and improve servo accuracy by eliminating gear related machining problems. So, in this paper, characteristic of 2-axis linear motor feed unit are studied and control gain are adjusted considering positioning, velocity, acceleration and static stiffness. We confirm linear motor feed unit are affected value of control gain sensitively, because drive directly. From the experiment, this feed unit has l${\mu}{\textrm}{m}$ micro step resolution, 5.7${\mu}{\textrm}{m}$ positioning accuracy and under 60${\mu}{\textrm}{m}$ circularity.

  • PDF

Box Feature Estimation from LiDAR Point Cluster using Maximum Likelihood Method (최대우도법을 이용한 라이다 포인트군집의 박스특징 추정)

  • Kim, Jongho;Yi, Kyongsu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.4
    • /
    • pp.123-128
    • /
    • 2021
  • This paper present box feature estimation from LiDAR point cluster using maximum likelihood Method. Previous LiDAR tracking method for autonomous driving shows high accuracy about velocity and heading of point cluster. However, Assuming the average position of a point cluster as the vehicle position has a lower accuracy than ground truth. Therefore, the box feature estimation algorithm to improve position accuracy of autonomous driving perception consists of two procedures. Firstly, proposed algorithm calculates vehicle candidate position based on relative position of point cluster. Secondly, to reflect the features of the point cluster in estimation, the likelihood of the particle scattered around the candidate position is used. The proposed estimation method has been implemented in robot operating system (ROS) environment, and investigated via simulation and actual vehicle test. The test result show that proposed cluster position estimation enhances perception and path planning performance in autonomous driving.

Research on Shellfish Recognition Based on Improved Faster RCNN

  • Feng, Yiran;Park, Sang-Yun;Lee, Eung-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.5
    • /
    • pp.695-700
    • /
    • 2021
  • The Faster RCNN-based shellfish recognition algorithm is introduced for shellfish recognition studies that currently do not have any deep learning-based algorithms in a practical setting. The original feature extraction module is replaced by DenseNet, which fuses multi-level feature data and optimises the NMS algorithm, network depth and merging method; overcoming the omission of shellfish overlap, multiple shellfish and insufficient light, effectively solving the problem of low shellfish classification accuracy. In the complexifier test environment, the test accuracy was improved by nearly 4%. Higher testing accuracy was achieved compared to the original testing algorithm. This provides favourable technical support for future applications of the improved Faster RCNN approach to seafood quality classification.

Evaluation of horizontal position Accuracy of Facilities in Digital Map (수치지도 상에 있는 시설물들에 대한 수평위치 정확도 평가)

  • Choi, Seung-Pil;Yang, In-Tae;Cho, Jee-Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.10 no.4 s.22
    • /
    • pp.95-103
    • /
    • 2002
  • The accuracy of Digital Map does not meet the user's expectation, including the many errors caused while producing the project, this will be useless resulting waste of enormous national budget. To solve this Accuracy problem, clear regulations about the position accuracy of scaled Digital Map should be set immediately and provide the users with accurate information about Digital Map enabling the users to use Digital Map for each GIS application field. For this reason, the position accuracy evaluation of existing Digital Maps produced in diverse methods is on demand. In this study, therefore, we performed horizontal position survey of local selected Facilities Total Station equipment to evaluate the horizontal position accuracy of 1:1,000, 1:5,000 scaled Digital Map, obtained standard deviation using the results, performed T-Test to confirm the presence of bias and evaluated the position accuracy of Digital Map.

  • PDF

Evaluating Accuracy according to the Evaluator and Equipment Using Electronic Apex Locators

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • v.13 no.2
    • /
    • pp.52-58
    • /
    • 2020
  • Purpose: Using two types of electronic apex locators, this study aimed to investigate the differences in accuracy according to the evaluator and equipment. Materials and Methods: Artificial teeth of the lower first premolars and two mandibular acrylic models (A and B) were used in this study. In the artificial teeth, the pulp chamber was opened and the access cavity was prepared. Using calibrated digital Vernier calipers, the distance from the top of the cavity and the root apex was measured to assess the actual distance between two artificial teeth. The evaluation was conducted by 20 dentists, and each evaluator repeated measurements for each electronic apex locator five times. The difference between the actual distance from the top of the cavity to the root apex and the distance measured using electronic measuring equipment was compared. For statistical analysis, the Friedman test the Mann-Whitney U-test were conducted and the differences between groups were analyzed (α=0.05). Result: As for the accuracy of measurement according to the two types of electronic apex locators, the value of the measurement error was 0.4753 mm in Dentaport ZX and 0.3321 mm in E-Cube Plus. Moreover, electronic apex locators Dentaport ZX and E-Cube Plus showed statistically significant differences (P<0.05). As for the difference in the accuracy of the two types of electronic apex locators according to the evaluator, the resulting values differed depending on the evaluator and showed a statistically significant difference (P<0.001). Conclusion: Electronic apex locator E-Cube Plus showed higher accuracy than did Dentaport ZX. Nevertheless, both types of electronic apex locators showed 100% accuracy in finding the region within root apex ±0.5 mm zone. Furthermore, according to the evaluator, the two electronic apex locators showed different resulting values.

Effect of internal structures on the accuracy of 3D printed full-arch dentition preparation models in different printing systems

  • Teng Ma;Tiwu Peng;Yang Lin;Mindi Zhang;Guanghui Ren
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.145-154
    • /
    • 2023
  • PURPOSE. The objective of this study was to investigate how internal structures influence the overall and marginal accuracy of full arch preparations fabricated through additive manufacturing in different printing systems. MATERIALS AND METHODS. A full-arch preparation digital model was set up with three internal designs, including solid, hollow, and grid. These were printed using three different resin printers with nine models in each group. After scanning, each data was imported into the 3D data processing software together with the master cast, aligned and trimmed, and then put into the 3D data analysis software again to compare the overall and marginal deviation whose results are expressed using root mean square values and color maps. To evaluate the trueness of the resin model, the test data and reference data were compared, and the precision was evaluated by comparing the test data sets. Color maps were observed for qualitative analysis. Data were statistically analyzed by one-way analysis of variance and Bonferroni method was used for post hoc comparison (α = .05). RESULTS. The influence of different internal structures on the accuracy of 3D printed resin models varied significantly (P < .05). Solid and grid models showed better accuracy, while the hollow model exhibited poor accuracy. The color maps show that the resin models have a tendency to shrink inwards. CONCLUSION. The internal structure design influences the accuracy of the 3D printing model, and the effect varies in different printing systems. Irrespective of the kind of printing system, the printing accuracy of hollow model was observed to be worse than those of solid and grid models.

Studying the Ephemeris Effect on Position Accuracy Based on Criteria Applied to Baseline Lengths by New MATLAB Program (NMP)

  • Shimaa Farouk;Mahmoud El-Nokrashy;Ahmed Abd-Elhay;Nasr Saba
    • Journal of Astronomy and Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.113-122
    • /
    • 2023
  • Although the Relative Global Navigation Satellite System (GNSS) positioning technique provides high accuracy, it has several drawbacks. The scarcity of control points, the long baselines, and using of ultra-rabid and rabid products increased position errors. This study has designed a New MATLAB Program that helps users automatically select suitable IGS stations related to the baseline lengths and the azimuth between GNSS points and IGS stations. This study presented criteria for the length of the baselines used in Egypt and an advanced estimated accuracy before starting the project. The experimental test studies the performance of the position accuracy related to the relation between three factors: observation session, final, rabid, and ultrarabid products, and the baseline lengths. Ground control point mediates Egypt was selected as a test point. Nine surrounding IGS stations were selected as reference stations, and the coordinates of the tested point were calculated based on them. Baselines between the tested point and the IGS stations were classified regarding proposal criteria. The coordinates of the tested point were obtained in different observation sessions (0.5, 1, 2, 4, 5, 6, 7, 7.5 h). The results indicated that the lengths of the baseline in Egypt were classified short (less than 600 km), medium (600-1,200 km), and long (greater than 1,200 km) and required a minimum observation time of 4, 5, and 7 h to obtain accuracy 10, 19, 48 mm sequentially. The position accuracy was superior for the rapid and the final than the ultra-rapid products by 16%. A short baseline was at the best case; there was a performance in position accuracy with a 57% deduction in observation time compared with the long baseline.

EVALUATION OF THE ACCURACY OF FIXTURE-LEVEL IMPRESSION TECHNIQUE FOR INTERNAL CONNECTION IMPLANT USING CLINICAL METHODS (임상적 방법을 이용한 내부연결 임플랜트에서 고정체수준 인상법의 정확도 평가)

  • Choi Jung-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.421-431
    • /
    • 2006
  • Statement of problem : Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression technique in internal connection implant system. Purpose: This study evaluated the accuracy of splinted fixture-level impression technique using clinical methods and the effect of internal hex on fit of superstructure in internal connection implant system (Astra Tech). Material and method : Two metal master frameworks made from two abutments (Cast-to Abutment ST) each for parallel and divergent conditions and a corresponding. passively fitting, dental stone master cast with four future replicas (Fixture Replica ST) were fabricated. Ten dental stone casts were made with vinyl polysiloxane impressions from the master cast by acrylic resin splinted fixture-level impression technique. To evaluate the accuracy of impression technique, the fit of master frameworks for test models was evaluated using screw resistance test (SRT) and one-screw test. The results of SRT were recorded as SRT values from grade 1 to grade 5 by 1/4 turn. And to evaluate the effect of hex on fit of superstructure, the same tests were performed after removing hexes of master frameworks. Results: 1. There was only one case (2.5%) showing SRT value of test model below ade 2 in total before and after removing hexes of master frameworks. And, by removing hexes. SRT values decreased in only one test model (5%) and did not change in 17 test models (85%). 2. SRT values of the 1$^{st}$ screws were grade 2 in 80% of cases before, and grade 1 in 80% of cases after removing hexes. And, by removing hexes, SRT values decreased in 72.5% of cases. 3. SRT values of the 2$^{nd}$ screws were grade 3 in 85% of cases before, and grade 3 in 95% of cases after removing hexes. And, by removing hexes, SRT values did not change in 85% of cases. 4. There were only 2 cases regarded as acceptable fit by one-screw test, and SRT values of 2$^{nd}$ screws of both cases were grade 2. Conclusion. Within the limitations of this study, future-level impression of internal connection implant system is considered to obtain inaccurate working cast, even using acrylic resin splinted impression technique. And, it is considered to be unable improve the fit to remove the hexes of implant restoration.

An Assessment of the Accuracy for Digital Radiography Image (디지털 방사선투과영상의 정밀성 평가에 관한 연구)

  • Park, Sang-Ki;Ahn, Yean-Shik;Gil, Doo-Song
    • Journal of Welding and Joining
    • /
    • v.27 no.2
    • /
    • pp.51-56
    • /
    • 2009
  • Film based radiography imaging technique has been applied to the non-destructive test in medical, aircraft, and power industries contributing to the development of the industries. However, the complex process for imaging and analysis has increasingly demanded the reformation of the radiography test. A digital radiography imaging technologies has been com out from the demand. This study was mainly focused on the assessment on the accuracy for the each image from digital radiography test and film radiography test was proven to crate a better image in sensitivity than film radiography test. In the IQI(Image quality indicator) transmission test, one or two more line can be seen in digital image than in film image. When applying to the boiler tube weld, film image is detectable to the 1.0mm depth flaw; and digital image to the 0.5mm depth flaw. As a result of this study, digital radiography technology is determined to enhance the image quality, compared to film radiography technologies

Experimental Study on Hydrodynamic Coefficients of Autonomous Underwater Glider Using Vertical Planar Motion Mechanism Test (VPMM 시험을 통한 무인 수중 글라이더 모형의 동유체력 계수 추정에 관한 연구)

  • Jung, Jin-Woo;Jeong, Jae-Hun;Kim, In-Gyu;Lee, Seung-Keon
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.119-125
    • /
    • 2014
  • A vertical planar motion mechanism(VPMM) test was used to increase the prediction accuracy for the maneuverability of an underwater glider model. To improve the accuracy of the linear hydrodynamic coefficients, the analysis techniques of a pure heave test and pure pitch test were developed and confirmed. In this study, the added mass and damping coefficient were measured using a VPMM test. The VPMM equipment provided pure heaving and pitching motions to the underwater glider model and acquired the forces and moments using load cells. As a result, the hydrodynamic coefficients of the underwater glider could be acquired after a Fourier analysis of the forces and moments. Finally, a motion control simulation was performed for the glider control system, and the results are presented.