• 제목/요약/키워드: Tensioning method

검색결과 107건 처리시간 0.019초

Use of a Barbed Suture Tie-Over Technique for Skin Graft Dressings: A Case Series

  • Joyce, Kenneth M.;Joyce, Cormac W.;Mahon, Nicola;Kelly, Jack L.
    • Archives of Plastic Surgery
    • /
    • 제42권3호
    • /
    • pp.341-345
    • /
    • 2015
  • Background A tie-over dressing is the accepted method to secure skin grafts in order to prevent haematoma or seroma formation. We describe the novel application of a barbed suture tie-over for skin graft dressing. The barbs act as anchors in the skin so constant tensioning of the suture is not required. Methods From January 2014 to August 2014 we used the technique in 30 patients with skin defects requiring split-thickness or full-thickness grafts. Patient demographics, clinicopathological details and graft outcome were collected prospectively. Results The majority of cases were carried out for split-thickness skin grafts (n=19) used on the lower limb (n=20). The results of this novel technique were excellent with complete (100%) graft take in all patients. Conclusions Our results demonstrate the clinical application of a barbed device for securing skin grafts with excellent results. We find the technique quick to perform and the barbed device easy to handle, which can be applied without the need for an assistant.

막장력 측정을 통한 막구조물의 장력 유지관리 시스템 검토 (Review of Membrane Tension Maintenance System for Membrane Structures through Membrane Tension Measurement)

  • 진상욱;손수덕;이승재
    • 한국공간구조학회논문집
    • /
    • 제16권2호
    • /
    • pp.39-45
    • /
    • 2016
  • Membrane structure is a system that is stabilized by maintaining a tensile state of the membrane material that originally cannot resist the bending or pressure. Also, it is a system that allows the whole membrane structure to bear external loads caused by wind or precipitation such as snow, rain and etc. Tension relaxation phenomenon can transpire to the tension that is introduced to the fabric over time, due to the innate characteristics of the membrane material. Thus, it is important to accurately understand the size of the membrane tension after the completion of the structures, for maintenance and management purposes. The authors have proposed the principle of theoretically and indirectly measuring the tension by vibrating the membrane surface with sound waves exposures against the surface, which is compartmentalized by a rectangular boundary, and by measuring the natural frequency of the membrane surface that selectively resonates. The authors of this paper measured the tension of preexisting membrane structure for its maintenance by using the developed portable measurement equipment. Through analyzing the measurement data, the authors review the points that should be improved and the technical method for the new maintenance system of membrane tension.

Flexural behavior of post-tensioned precast concrete girder at negative moment region

  • Choi, Seung-Ho;Heo, Inwook;Kim, Jae Hyun;Jeong, Hoseong;Lee, Jae-Yeon;Kim, Kang Su
    • Computers and Concrete
    • /
    • 제30권1호
    • /
    • pp.75-83
    • /
    • 2022
  • This study introduced a post-tensioned precast concrete system that was developed and designed to improve the performance of joints by post-tensioning. Full-scaled specimens were tested to investigate flexural performances at the negative moment region, where the test variables were the presence of slabs, tendon types, and post-tensioned lengths. A specimen with slabs exhibited significantly higher stiffness and strength values than a specimen without slabs. Thus, it would be reasonable to consider the effects of a slab on the flexural strength for an economical design. A specimen with unbonded mono-tendons had slightly lower initial stiffness and flexural strength values than a specimen with bonded multi-tendons but showed greater flexural strength than the value specified in the design codes. The post-tensioned length was found to have no significant impact on the flexural behavior of the proposed post-tensioned precast concrete system. In addition, a finite element analysis was conducted on the proposed post-tensioned precast concrete system, and the tests and analysis results were compared in detail.

IPC 거더를 이용한 장지간 철도교 설계에 관한 연구 (Development of Long-Span Railway Bridges Design Using IPC Girder)

  • 장원석;박준명;박선규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.149-158
    • /
    • 2003
  • 기존의 프리스트레스 콘크리트 거더의 설계개념은 초기에 긴장된 강선의 긴장력으로 초기상태에서의 응력과 사용상태에서의 응력이 허용한계내에 들도록 설계하여 왔다. 이러한 설계방법은 거더의 단면이 커지는 단점이 있다. 본 연구에서는 철도하중을 받는 교량에 대하여 강선의 긴장력을 단계적으로 증가시키는 프리스트레스 콘크리트 설계이론을 제안하여 거더의 단면을 감소시켜 설계의 간편성과 시공성 및 경제성을 확보하고자 하였다. 그리고 제안된 설계방법을 적용하여 기존의 철도교보다 거더의 단면을 감소시켜 장지간의 교량을 설계하였으며 긴장재를 연속적으로 배치하여 IPC교량의 연속화를 제안하였다.

Unified equivalent frame method for post-tensioned flat plate slab structures

  • Choi, Seung-Ho;Lee, Deuck Hang;Oh, Jae-Yuel;Kim, Kang Su;Lee, Jae-Yeon;Lee, Kang Seok
    • Computers and Concrete
    • /
    • 제20권6호
    • /
    • pp.663-670
    • /
    • 2017
  • The post-tensioned (PT) flat plate slab system is commonly used in practice, and this simple and fast construction method is also considered to be a very efficient method because it can provide excellent deflection and crack control performance under a service load condition and consequently can be advantageous when applying to long-span structures. However, a detailed design guideline for evaluating the lateral behavior of the PT flat plate slab system is not available in current design codes. Thus, typical design methods used for conventional reinforced concrete (RC) flat plate slab structures have inevitably been adopted in practice for the lateral load design of PT flat plate structures. In the authors' previous studies, the unified equivalent frame method (UEFM) was proposed, which considers the combined effect of gravity and lateral loads for the lateral behavior analysis of RC flat plate slab structures. The aim of this study is to extend the concept of the UEFM to the lateral analysis of PT flat plate slab structures. In addition, the stiffness reduction factors of torsional members on interior and exterior equivalent frames were newly introduced considering the effect of post-tensioning. Test results of various PT flat plate slab-column connection specimens were collected from literature, and compared to the analysis results estimated by the extended UEFM.

New three-layer-type hysteretic damper system and its damping capacity

  • Kim, Hyeong Gook;Yoshitomi, Shinta;Tsuji, Masaaki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제3권6호
    • /
    • pp.821-838
    • /
    • 2012
  • This paper proposes a new three-layer pillar-type hysteretic damper system for residential houses. The proposed vibration control system has braces, upper and lower frames and a damper unit including hysteretic dampers. The proposed vibration control system supplements the weaknesses of the previously proposed post-tensioning vibration control system in the damping efficiency and cumbersomeness of introducing a post-tension. The structural variables employed in the damper design are the stiffness ratio ${\kappa}$, the ductility ratio ${\mu}_a$, and the ratio ${\beta}$ of the damper's shear force to the maximum resistance. The hysteretic dampers are designed so that they exhibit the targeted damping capacity at a specified response amplitude. Element tests of hysteretic dampers are carried out to examine the mechanical property and to compare its restoring-force characteristic with that of the analytical model. Analytical studies using an equivalent linearization method and time-history response analysis are performed to investigate the damping performance of the proposed vibration control system. Free vibration tests using a full-scale model are conducted in order to verify the damping capacity and reliability of the proposed vibration control system. In this paper, the damping capacity of the proposed system is estimated by the logarithmic decrement method for the response amplitudes. The accuracy of the analytical models is evaluated through the comparison of the test results with those of analytical studies.

포스트 텐션 공법으로 보강된 SC 합성보의 휨 거동 (Flexural Behavior of Steel-Concrete Composite Beams Strengthened by Post Tension Method)

  • 류수현;김희철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권3호
    • /
    • pp.186-195
    • /
    • 2010
  • 본 논문은 SC합성보에 정착구의 높이, 새들의 형태, 가력시점을 변수로 하여 비부착 포스트텐션 보강을 하고 휨실험을 통해 보강방법을 평가하여 적절한 보강방법을 제시하고자 하엿다. 실험결과 보강 전 SC합성보의 최대내력은 실험값/이론값이 0.97로 나타났으나 보강 후는 1.00~1.21로 나타나 보강효과를 확인할 수 있었다. 변위 및 변형률 분석결과 정착구의 높이 및 가력시점에 상관없이 보강 후 중립축에 정착구를 설치한 D120계열 실험체가 최대하중이후 급격한 하중저하 없이 변위가 지속적으로 증가하며 각 부분의 변형률도 비교적 적게 나타나는 안정적인 거동을 했다. 보강효과면에서 선 가력 후 보강한 SCR-UD120실험체가 보강 전 SC합성보에 비해 최대내력이 1.72배 증가하여 가장 우수한 것으로 나타났다.

현장 잔존긴장력 평가를 통한 리프트오프 시험 방법 개선 (Improvement of Lift-off Tests via Field Evaluation of Residual Load in Ground Anchor)

  • 송민권;박성열;이상래;조완제
    • 한국지반공학회논문집
    • /
    • 제35권5호
    • /
    • pp.43-51
    • /
    • 2019
  • 현재 국내에서는 비탈면의 안정성 확보를 위해 그라운드 앵커공법을 적용하고 있다. 그라운드 앵커는 시간이 지남에 따라 노후화 및 환경적 영향에 의한 부식, 릴렉세이션, 크립 등으로 긴장력 감소현상이 발생하며, 이로 인해 앵커의 긴장력은 설계앵커력 이하로 감소할 가능성을 내포하고 있다. 이에 국내에서는 정기적인 점검 시 또는 이상 징후가 발생한 앵커를 대상으로 리프트오프 시험을 수행하여 앵커의 잔존긴장력을 확인하고 있으나, 현재 국내 리프트오프 시험기준(국토해양부, 2010)은 수행 및 평가방법이 자세히 명시되어 있지 않은 실정이다. 이에 본 연구에서는 선행연구들을 바탕으로 하중 재하 제하 사이클, 하중 증분방법, 긴장재 긴장 방법 등을 고려하여 리프트오프 시험을 수행하였으며 현장에서의 시공성과 시간적 제한을 고려하여 효율적인 리프트오프 시험 및 평가방법 개선안을 제시하였다.

카테너리 각도를 이용한 가공송전도체의 이도 추정 (Dip Estimation for Overhead Transmission Conductor using Catenary Angle)

  • 김성덕;손홍관;장태인
    • 조명전기설비학회논문지
    • /
    • 제21권5호
    • /
    • pp.112-119
    • /
    • 2007
  • 가공송전 도체는 정상 동작조건 하에서 전력회사의 선로 설계지침에 규정된 지상고를 안정범위 내에서 항상 유지할 수 있어야 한다. 따라서 새로운 선로를 건설하거나 노화도체의 장력을 다시 조정하거나 또는 전력용량을 최대화하기 위해 동적송전용량을 모니터링하는 경우에, 도체 이도를 측정/또는 모니터링하는 것은 매우 중요하다. 본 연구에서는 도체의 카테너리 각도로 이도 및 장력을 추정하기 위한 새로운 방법을 제안한다. 가공송전선로의 대부분의 도체들은 전형적인 카테너리 곡선을 나타내므로 철탑 측의 카테너리 각도로부터 도체의 카테너리 곡선을 유일하게 결정할 수 있다. 이 카테너리 곡선을 토대로 도체의 이도나 수평장력을 쉽게 추정할 수 있다. 몇 가지 시뮬레이션과 간단한 실험 결과를 통하여 제안된 방법이 가공송전선의 도체 이도와 장력을 측정/또는 모니터링하는데 효과적으로 사용될 수 있음을 확인하였다.

다단계 자중 프리플렉스 및 프리스트레싱 합성거더의 시공단계에 따른 휨성능 평가 (Flexural Performance of Multistage Prestressed and Self-weight Preflex Girder)

  • 최병호;김태봉;박성균
    • 한국강구조학회 논문집
    • /
    • 제29권4호
    • /
    • pp.311-321
    • /
    • 2017
  • 이 논문은 거푸집의 설치없이 간편하게 합성단면을 형성하고 다단계의 자중 프리플렉스 및 프리스트레싱을 비교적 쉽게 구현할 수 있도록 고안된 합성거더 시스템의 휨성능에 관한 것이다. 시공단계를 고려한 3차원 유한요소해석모형을 수립하고 콘크리트 타설방법과 강연선 긴장방법을 변수로 지정하여 합성거더 단면에 작용하는 선응력 분포와 강연선에 의해 도입되는 긴장효과를 수치 해석적으로 분석하였다. 변수 해석 결과를 비교하여 응력분포가 가장 유리한 해석모델의 제작과정을 표준제작단계로 선정하여 비선형비탄성 해석을 통해 극한휨강도를 평가하였다. 이를 국내 설계기준에서 제시하는 기준강도와 비교 검토해보니, 적정 공칭내하력을 보유하는 것으로 확인되어 소요 안전율을 충분히 확보 가능할 것으로 판단된다.