• Title/Summary/Keyword: Tension test

Search Result 1,615, Processing Time 0.04 seconds

Interfacial Properties of Propylene Oxide Adducted Sodium Laureth Sulfate Anionic Surfactant (프로필렌 옥사이드를 부가한 소듐 라우레스 설페이트 음이온 계면활성제의 계면 특성에 관한 연구)

  • Jeong Min Lee;Ki Ho Park;Hee Dong Shin;Woo Jin Jeong;Jong Choo Lim
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.264-271
    • /
    • 2023
  • In this study, ASCO SLES-430 surfactant was synthesized by adducting 3 moles of ethylene oxide and 1 mole of propylene oxide to lauryl alcohol followed by a sulfation process, and the structure of the synthesized ASCO SLES-430 was elucidated by performing FT-IR, 1H-NMR and 13C-NMR analyses. Interfacial properties such as critical micelle concentration, static surface tension, emulsification index, and contact angle were measured, and environmental compatibility indices such as oral toxicity and skin irritation were also estimated for ASCO SLES-430. Both results were compared with ASCO SLES-226 and ASCO SLES-328 SLES surfactants possessing 2 moles and 3 moles of ethylene oxide, respectively. In particular, both foaming ability and foam stability were evaluated for ASCO SLES-430 and compared with ASCO SLES-226 and ASCO SLES-328, which have been widely used in detergent products, in order to test the potential applicability of ASCO SLES-430 in detergent product formulation for a small capacity built-in washing machine.

Self-Sensing and Interfacial Evaluation of Ni Nanowire/Polymer Composites Using Electro-Macromechanical Technique (전기적 미세역학적 시험법을 이용한 Ni nanowire강화 고분자 복합재료의 자체 감지능 및 계면 물성평가)

  • Kim, Sung-Ju;Yoon, Dong-Jin;Hansen George;DeVries K. Lawrence;Park, Joung-Man
    • Composites Research
    • /
    • v.19 no.5
    • /
    • pp.20-27
    • /
    • 2006
  • Self-sensing and interfacial evaluation of Ni nanowire/polymer composites were investigated using electro-macromechanical technique, which can be used fur a feasible sensing measurement on tensile and compressive loading/consequent unloading, temperature, and humidity. Mechanical properties of Ni nanowire with different aspect ratio and adding contents in either epoxy or silicone composites were measured indirectly using electro-pullout test under uniform and non-uniform cyclic loadings. Comparing apparent modulus with the conventional mechanical tensile modulus of Ni nanowire/epoxy composites, the trends were consistent with each other. Ni nanowire/epoxy composites showed the sensing response on humidity and temperature. Self-sensing on applied tensile and compressive loading/unloading was also responded for Ni nanowire/silicone composites via electrical contact resistivity showing the opposite trend between tension and compression. It can be due to the different electrically-interconnecting mechanisms of dispersed Ni nanowires embedded in silicone matrix.

Stress-strain Relations of Concrete Confined with Tubes Having Varying GFRP Layers (수적층 및 필라멘트 와인딩을 이용한 GFRP튜브로 구속된 콘크리트의 압축 거동)

  • Lee, Sung Woo;Choi, Sokhwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6A
    • /
    • pp.861-872
    • /
    • 2008
  • Concrete-filled glass fiber reinforced polymer tubes are often used for marine structures with the benefit of good durability and high resistance against corrosion under severe chemical environment. Current research presents results of a comprehensive experimental investigation on the behavior of axially loaded circular concrete-filled glass fiber reinforced polymer tubes. This paper is intended to examine several aspects related to the usage of glass fiber fabrics and filament wound layers used for outer shell of piles subjected to axial compression. The objectives of the study are as follows: (1) to evaluate the effectiveness of filament winding angle of glass fiber layers (2) to evaluate the effect of number of GFRP layers on the ultimate load and ductility of confined concrete (3) to evaluate the effect of loading condition of specimens on the effectiveness of confinement and failure characteristics as well, and (4) to propose a analytical model which describes the stress-strain behavior of the confined concrete. Three different types of glass fiber layers were chosen; fabric layer, ${\pm}45^{\circ}$ filament winding layer, and ${\pm}85^{\circ}$ filament winding layer. They were put together or used independently in the fabrication of tubes. Specimens that have various L:D ratios and different diameters have also been tested. Totally 27 GFRP tube specimens to investigate the tension capacity, and 66 concrete-filled GFRP tube specimens for compression test were prepared and tested. The behavior of the specimens in the axial and transverse directions, failure types were investigated. Analytical model and parameters were suggested to describe the stress-strain behavior of concrete under confinement.

Low Cost and High Sensitivity Flexible Pressure Sensor Based on Graphite Paste through Lamination after O2 Plasma Surface Treatment Process (O2 플라즈마 표면 처리 공정 후 라미네이션 공정으로 제작된 흑연 페이스트 기반의 저비용 및 고감도 유연 압력 센서)

  • Nam, Hyun Jin;Kang, Cheol;Lee, Seung-Woo;Kim, Sun Woo;Park, Se-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.21-27
    • /
    • 2022
  • Flexible pressure sensor was developed using low-cost conductive graphite as printed electronics. Flexible pressure sensors are attracting attention as materials to be used in future industries such as medical, games, and AI. As a result of evaluating various electromechanical properties of the printed electrode for flexible pressure sensors, it showed a constant resistance change rate in a maximum tensile rate of 20%, 30° tension/bending, and a simple pulse test. A more appropriate matrix pattern was designed by simulating the electrodes for which this verification was completed. Utilizing the Serpentine pattern, we utilized a process that allows simultaneous fabrication and encapsulation of the matrix pattern. One side of the printed graphite electrode was O2 plasma surface treated to increase adhesive strength, rotated 90 times, and two electrodes were made into one through a lamination process. As a result of pasting the matrix pattern prepared in this way to the wrist pulse position of the human body and proceeding with the actual measurement, a constant rate of resistance change was shown regardless of gender.

EFFECT OF THERMAL CYCLING AND AGING ON THE TENSILE STRENGTH OF GLASS-IONOMER RESTORATIVE MATERIALS (Thermal cycling과 시효처리가 Glass-Ionomer 수복재의 인장강도에 미치는 영향)

  • Baik, Byeong-Ju;Kim, Mun-Hyeon;Lee, Seung-Young;Lee, Seung-Ik;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.4
    • /
    • pp.677-687
    • /
    • 1999
  • This study was performed to evaluate the effect of aging and thermal cycling on the tensile strength of six commercially available glass-ionomer materials: two chemically set glass-ionomer materials(Fuji II, Fuji IX), two resin-modified glass-ionomer materials(Fuji II LC, Vitremer), and two polyacid-modified composite resins(Compoglass, Dyract). Rectangular tension test specimens were fabricated in a teflon mold giving 5mm in gauge length and 2mm in thickness. All samples were divided into 3 groups. Group 1 was immersed in a $37^{\circ}C$ distilled water for 1 hour. Group 2 was immersed in a $37^{\circ}C$ distilled water for 30 days. Group 3 was subjected to 10,000 thermal cycles between $5^{\circ}C$ and $55^{\circ}C$, and the immersion time in each bath was 15 seconds per cycle. Tensile testing was carried out at a cross-head speed of 0.5mm/min and fracture surfaces were examined with scanning electron microscope. The results obtained were summarized as follows; 1. The polyacid-modified composite resins were stronger than the resin-modified glass-ionomer materials, which were much stronger than the conventional glass-ionomer materials. 2. Tensile strengths were slightly increased after aging treatments for 30days. 3. Tensile strengths of conventional glass ionomers were significantly increased after thermal cycling treatment(p<0.01). 4. The highest tensile strength value of 45.4MPa was observed in the Dyract group and the lowest value of 13.3MPa was observed in the Fuji II LC group after the thermal cycling test, and the strengths of polyacid-modified composite groups were significantly higher than those of other groups. 5. The highest characteristic strength value of 48.6MPa was obtained in the Dyract group, however the highest Weibull modulus value of 8.9MPa was obtained in the Compoglass group after thermal cycling test.

  • PDF

Comparison of Clinical Results and Second-Look Arthroscopy after Anterior Cruciate Ligament Reconstruction using Hamstring Tendon Autograft, Mixed graft and Tibialis Tendon Allograft (자가슬괵건, 혼합건 및 동종 경골건을 이용하여 실시한 전방십자인대 재건술후 임상결과 및 이차관절경 검사 비교)

  • Cho, Jin-Ho
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.18-26
    • /
    • 2011
  • Purpose: This study is to compare the clinical results of ACL reconstruction between three groups using hamstring tendon autograft, mixed and tibialis tendon allograft. Materials and Methods: Between August 2003 and August 2008, we analyzed 169 cases of ACL reconstruction, 66 cases used hamstring tendon autograft, 42 cases used mixed graft and 61 cases used tibialis tendon allograft, with a minimum follow-up of 12 months. For the clinical evaluation, we evaluated the Lysholm score, Telos stress test device and IKDC score. Results: The average side to side difference in Telos stress test decreased from $7.5{\pm}1.0$ mm to $1.6{\pm}1.0$ mm in autograft group, from $7.6{\pm}1.1$ mm to $1.4{\pm}1.1$ mm in mixed graft group and from $7.4{\pm}1.3$ mm to $2.5{\pm}1.3$ mm in allograft group. The average Lysholm knee score improved from 58.6 to 92.3 in autograft group, from 60.6 to 92.6 in mixed graft group and from 55.3 to 91.5 in allograft group. There was no significant difference between three groups in clinical results. At second look arthroscopy, tension of ligament and synovial coverage were good result in autograft and mixed graft than allograft group. Conclusion: All hamstring tendon autograft, mixed graft and tibialis tendon allograft groups showed satisfactory clinical results, with no significant difference in outcomes between the groups. Both hamstring tendon autograft and mixed graft showed good synovial coverage in second look arthroscopy. So mixed graft will be considered as good alternative in case of shorter or thin harvested hamstring tendon.

  • PDF

Mechanical and Rheological Properties of Rice Plant (수도(水稻)의 역학적(力學的) 및 리올러지 특성(特性)에 관(關)한 연구(硏究))

  • Huh, Yun Kun;Cha, Gyun Do
    • Korean Journal of Agricultural Science
    • /
    • v.14 no.1
    • /
    • pp.98-133
    • /
    • 1987
  • The mechanical and rheological properties of agricultural materials are important for engineering design and analysis of their mechanical harvesting, handling, transporting and processing systems. Agricultural materials, which composed of structural members and fluids do not react in a purely elastic manner, and their response when subjected to stress and strain is a combination of elastic and viscous behavior so called viscoelastic behavior. Many researchers have conducted studies on the mechanical and rheological properties of the various agricultural products, but a few researcher has studied those properties of rice plant, and also those data are available only for foreign varieties of rice plant. This study are conducted to experimentally determine the mechanical and the rheological properties such as axial compressive strength, tensile strength, bending and shear strength, stress relaxation and creep behavior of rice stems, and grain detachment strength. The rheological models for the rice stem were developed from the test data. The shearing characteristics were examined at some different levels of portion, cross-sectional area, moisture content of rice stem and shearing angle. The results obtained from this study were summarized as follows 1. The mechanical properties of the stems of the J aponica types were greater than those of the Indica ${\times}$ Japonica hybrid in compression, tension, bendingand shearing. 2. The mean value of the compressive force was 80.5 N in the Japonica types and 55.5 N in the Indica ${\times}$ Japonica hybrid which was about 70 percent to that of the Japonica types, and then the value increased progressively at the lower portion of the stems generally. 3. The average tensile force was about 226.6 N in the Japonica types and 123.6 N in the Indica ${\times}$ Japonica hybrid which was about 55 percent to that of the Japonica types. 4. The bending moment was $0.19N{\cdot}m$ in the Japonica types and $0.13N{\cdot}m$ in the Indica ${\times}$ Japonica hybrid which was 68 percent to that of the Japonica types and the bending strength was 7.7 MPa in the Japonica types and 6.5 MPa in the Indica ${\times}$ Japonica hybrid respectively. 5. The shearing force was 141.1 N in Jinju, the Japonica type and 101.4 N in Taebaeg, the Indica ${\times}$ Japonica hybrid which was 72 percent to that of Jinju, and the shearing strength of Taebaeg was 63 percent to that of Jinju. 6. The shearing force and the shearing energy along the stem portion in Jinju increased progressively together at the lower portions, meanwhile in Taebaeg the shearing force showed the maximum value at the intermediate portion and the shearing energy was the greatest at the portion of 21 cm from the ground level, and also the shearing strength and the shearing energy per unit cross-sectional area of the stem were the greater values at the intermediate portion than at any other portions. 7. The shearing force and the shearing energy increased with increase of the cross-sectional area of the rice stem and with decrease of the shearing angie from $90^{\circ}$ to $50^{\circ}$. 8. The shearing forces showed the minimum values of 110 N at Jinju and of 60 N at Taebaeg, the shearing energy at the moisture content decreased about 15 percent point from initial moisture content showed value of 50 mJ in Jinju and of 30 mJ in Taebaeg, respectively. 9. The stress relaxation behavior could be described by the generalized Maxwell model and also the compression creep behavior by Burger's model, respectively in the rice stem. 10. With increase of loading rate, the stress relaxation intensity increased, meanwhile the relaxation time and residual stress decreased. 11. In the compression creep test, the logarithmic creep occured at the stress less than 2.0 MPa and the steady-state creep at the stress larger than 2.0 MPa. 12. The stress level had not a significant effect on the relaxation time, while the relaxation intensity and residual stress increased with increase of the stress level. 13. In the compression creep test of the rice stem, the instantaneous elastic modulus of Burger's model showed the range of 60 to 80 MPa and the viscosities of the free dashpot were very large numerical value which was well explained that the rice stem was viscoelastic material. 14. The tensile detachment forces were about 1.7 to 2.3 N in the Japonica types while about 1.0 to 1.3 N in Indica ${\times}$ Japonica hybrid corresponding to 58 percent of Japonica types, and the bending detachment forces were about 0.6 to 1.1 N corresponding to 30 to 50 percent of the tensile detachment forces, and the bending detachment of the Indica ${\times}$ Japonica hybrid was 0.1 to 0.3 N which was 7 to 21 percent of Japonica types. 15. The detachment force of the lower portion was little bigger than that of the upper portion in a penicle and was not significantly affected by the harvesting period from September 28 to October 20. 16. The tensile and bending detachment forces decreased with decrease of the moisture content from 23 to 13 percent (w.b.) by the natural drying, and the decreasing rate of detachment forces along the moisture content was the greater in the bending detachment force than the tensile detachment force.

  • PDF

A Study on Improvement for Fishing Gear and Method of Pound Net - I - Net Shapes of the Commerical Net in the Flow - (정치망 어구어법의 개발에 관한 연구-I - 현용어구의 흐름에 대한 형상 변화 -)

  • Yun, Il-Bu;Lee, Ju-Hee;Kwon, Byeong-Guk;Cho, Young-Bok;Yoo, Jae-Bum;Kim, Seong-Hun;Kim, Boo-Young
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.4
    • /
    • pp.268-281
    • /
    • 2004
  • A study was carried out in order to estimate the deformation of the pound net according to the current by the model test in the circulating water channel. The tension of the frame rope and the variation of net shape were measured to investigate the deforming of the model pound net in the flow. The results are obtained as follows; 1. The experimental equation between tensions (R) of the frame rope and velocity (ν)was found to be R=$19.58v^{1.98}$($r^2$=0.98) in case of the upperward flow with fish court net and R=$26.90v^{1.72}$($r^2$=0.95)at the upperward flow with bag net according to the velocity from 0.0m/s to 0.6m/s, respectively. 2. As the variation of flow speed inside of the model net was gradually decreased according as which is passed through netting panels, in case of the upperward flow with fish court net, the flow speed was about 70% of initial flow speed at 0.1m/s, 60% at 0.2m/s, 50% at 0.3m/s and 40% 0.4~0.6m/s at the measurement point(h) inside of the first bag net, respectively. In case of the upperward flow with bag net, as the flow speed was steeply decreased according as which if passed through the second bag net, it was 30~60% of the initial flow speed and was 20~30% inside of the first bag net and was about 10~20% inside of the inclined passage net. 3. In case of the upperward flow with fish court net, the variation of deformed angle of fish court net was from 0$^{\circ}$ to 70$^{\circ}$and that of inclined passage net was from 0$^{\circ}$ to 63$^{\circ}$and that of the second bag net was from 0$^{\circ}$ to 47$^{\circ}$ . 4. In case of the upperward flow with fish court net, the variation of deformed angle of the second bag net was changed from 0$^{\circ}$ to 70$^{\circ}$and that of the inclined passage net was from 0$^{\circ}$ to 55$^{\circ}$ and that of the fish court net was from 0$^{\circ}$ to 50$^{\circ}$. The depth ratio of the first bag net was changed from 0% to 35% and that of the second bag net was from 0% to 20% and that of the inclined passage net was from 0% to 35%. In the flow speed 0.5m/s, the inclined passage net was raised up to the entry of the bag net and then prevented it more over 90%. 5. To be increased the opening volume of pound net, it needs to attach the added weight outside of the fish court net, inclined passage net and bag net. At the same time, it needs to adjust the tension of the twine for maintenance of the shape.

Comparison of Cleaning Performance of CFC 113 and the Alternatives (CFC 113과 대체세정제의 세정성능 비교)

  • Row, Kyung Ho;Choi, Dai-Ki;Lee, Youn Yong
    • Analytical Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.521-530
    • /
    • 1993
  • According to the Montreal Protocol, CFC 113, one of the ozone-depleting substances, will be prohibited to use as a cleaning solvent essentially in the electronic industry. Therefore, the development of the alternative cleaning solvents to CFC 113 is being accelerated. A number of the alternative cleaning solvents are avialable on the market. The alternatives of Axarel 32(DuPont), Cleanthru 750H(KAO Chemical), and EC-Ultra(Petroferm) are chosen for the comparison of cleaning performance with CFC 113. The test methods for measuring the cleaning performance were composed of the measurement of the physical properties, the experiments on the material compatibility with cleaning solvents, the measurement of the evaporation rate, and finally the experiments of the removal efficiency. Normally the basic physical properties of the alternatives had higher boiling points, viscosity and surface tension, which were quite different to those of CFC 113. In terms of solubility of rosin-based flux, the solubilities of abietic acid (nonpolar organic) were similar, but those of the activator (polar organic) in the alternatives were better than CFC 113. The evaporation of the alternatives was very slow, compared to CFC 113, which had much lower boiling point. All the cleaning solvents showed the good material compatibility with FR4 and Cu-coated PCB. The better removal efficiencies of abietic acid were obtained when using the ultrasonic mechanical energy over the dipping method. The experiments also indicated the very slow-eavaporating solvent was not desirable with the dipping cleaning method, and the differences in the removal efficiency of the alternatives with the ultrasonic cleaning method were negligible. Among the alternatives, the overall cleaning performances were obsorved as almost similar. Before selecting the ultimate cleaning solvent, the application of cleaning machine, environmental issues, and economics are simultaneously considered with the cleaning performance.

  • PDF

Changes in Arterial Oxygen Tension($PaO_2$) and Cardiac Arrhvthmias after Endotracheal Suction (기관내 흡인 실시 후의 동맥혈 산소 분압 변화와 심부정맥 발현에 관한 연구)

  • Kim, Sun-Wha;Shin, Jung-Sook;Choi, Young-Hee
    • The Korean Nurse
    • /
    • v.33 no.4
    • /
    • pp.62-85
    • /
    • 1994
  • The data were analyzed by using an S. P. S. S. computerized program for mean, standard deviation, percentage and paired t-test. The results of this study were as follows: 1. The increase in $PaO_2$ after hyperoxygenation and hyperinflation was highly statistically significant(p=0.041), and the increase in $PaO_2$ immediately after suctioning was not significant (p=0.752). The time of lowest $PaO_2$ was 30 seconds after the endotracheal suction. 2. The occurrance of cardiac arrhythmia after the endotracheal suction included sinus tachycardia, sinus arrhythmia, sinus bradycardia, premature atrial contraction (PAC), and premature ventricular contraction (PVC). The most frequent cardiac arrhythmia was sinus tachycardia (a subjects). Sinus arrhythmia was observed in 5 subjects and continued till 10 minutes after suctioning in two of these. Sinus bradycardia occurred in only 3 subjects and among them, 1 subjects shows sinus arrythmia till 10 minutes after suctioning along. PAC was observed in only one subject and continued till five minutes after suctining along with sinus arrhythmia. PVC was observed in three subjects: it lasted for only 30 seconds after suctioning in two subjects. but continued for 10 minutes after suctioning in the third. 6 subjects manifested two kinds of Cardiac arrhythmia Three of them showed sinus tachycardia with PVC, another 2 showed sinus bradycardia with sinus arrhythmia, and the other subject showed sinus arrhythmia with PAC. 3. The increases in heart rate during the endotracheal suction immediately after and at 30 seconds after suctioning were statistically significant (p=0.005). The increase in heart rate at one minute after suctioning was also significant (p=0.023). The increase in heart rate continued until 10 minutes after the endotracheal suction, but was not statistically significant In this study, endotracheal suctioning with hyperoxygenation and hyperinflation was effective in preventing a decrease in $PaO_2$ after suctioning, but not in preventing cardiac arrhythmias. Nurses should be aware of the complications of endotracheal suctioning and do effective hyperoxygenation and hyperinflation before and after suctioning. Further research is needed to develop a efficient endotracheal suction method which will minimize complications. This study needs to be replicated with different population of patients intubatted or having a tracheostomy, specifically, patients who cardiac or pulmonary desease. The data were analyzed by using an S. P. S. S. computerized program for mean, standard deviation, percentage and paired t-test. The results of this study were as follows: 1. The increase in $PaO_2$ after hyperoxygenation and hyperinflation was highly statistically significant(p=0.041), and the increase in $PaO_2$ immediately after suctioning was not significant (p=0.752). The time of lowest $PaO_2$ was 30 seconds after the endotracheal suction. 2. The occurrance of cardiac arrhythmia after the endotracheal suction included sinus tachycardia, sinus arrhythmia, sinus bradycardia, premature atrial contraction (PAC), and premature ventricular contraction (PVC). The most frequent cardiac arrhythmia was sinus tachycardia (a subjects). Sinus arrhythmia was observed in 5 subjects and continued till 10 minutes after suctioning in two of these. Sinus bradycardia occurred in only 3 subjects and among them, 1 subjects shows sinus arrythmia till 10 minutes after suctioning along. PAC was observed in only one subject and continued till five minutes after suctining along with sinus arrhythmia. PVC was observed in three subjects: it lasted for only 30 seconds after suctioning in two subjects. but continued for 10 minutes after suctioning in the third. 6 subjects manifested two kinds of Cardiac arrhythmia Three of them showed sinus tachycardia with PVC, another 2 showed sinus bradycardia with sinus arrhythmia, and the other subject showed sinus arrhythmia with PAC. 3. The increases in heart rate during the endotracheal suction immediately after and at 30 seconds after suctioning were statistically significant (p=0.005). The increase in heart rate at one minute after suctioning was also significant (p=0.023). The increase in heart rate continued until 10 minutes after the endotracheal suction, but was not statistically significant In this study, endotracheal suctioning with hyperoxygenation and hyperinflation was effective in preventing a decrease in $PaO_2$ after suctioning, but not in preventing cardiac arrhythmias. Nurses should be aware of the complications of endotracheal suctioning and do effective hyperoxygenation and hyperinflation before and after suctioning. Further research is needed to develop a efficient endotracheal suction method which will minimize complications. This study needs to be replicated with different population of patients intubatted or having a tracheostomy, specifically, patients who cardiac or pulmonary desease.

  • PDF