• Title/Summary/Keyword: Temperature-Humidity Index

Search Result 296, Processing Time 0.031 seconds

Geographical Distribution and Epidemiologic Factors of Chigger Mites on Apodemus agrarius during Autumn in Korea

  • Lee, In Yong;Lim, Jae-Won;Seo, Jang Hoon;Kim, Heung Chul;Lee, Ku Jae;Yong, Tai-Soon;Lee, Won-Ja;Yu, Jae-Ran;Sim, Seobo
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.5
    • /
    • pp.473-479
    • /
    • 2021
  • A nationwide survey of chigger mites causing scrub typhus and an investigation of epidemiologic factors for chigger mites was conducted at 16 localities in 8 provinces in Korea during autumn 2009, 2012, and 2013. A total of 233 Apodemus agrarius were captured, and all were infested with chigger mites. The chigger index was highest in Chungcheongbuk-do in 2009 (358.3) and 2012 (290.1) and Chungcheongnam-do in 2013 (294.4). The predominant chigger mite species was Leptotrombidium pallidum in the northern and central parts and L. scutellare in the southern and western parts, Korea. L. pallidum was not found in Jellanam-do and Gyeongsangnam-do and the distribution of L. scutellare had been expanded in the northern parts of Korea. The chigger index of L. pallidum was positively correlated with temperature and negatively correlated with humidity. The incidence of scrub typhus is dependent on L. scutellare index. These findings could be helpful to monitor the distribution of chigger mites and to develop a preventive measures for scrub typhus in Korea.

Effects of Land Cover Change on Summer Urban Heat Island Intensity and Heat Index in Seoul Metropolitan Area, Korea (서울 수도권 지역의 토지 피복 변화가 여름철 도시열섬 강도와 체감온도에 미치는 영향)

  • Hong, Seon-Ok;Byon, Jae-Young;Kim, Do-Hyeong;Lee, Sang-Sam;Kim, Yeon-Hee
    • Atmosphere
    • /
    • v.31 no.2
    • /
    • pp.143-156
    • /
    • 2021
  • This study investigates the impacts of land cover change due to urbanization on the Urban Heat Island Intensity (UHII) and the Heat Index (HI) over the Seoul metropolitan area using the Unified Model (UM) with the Met Office Reading Urban Surface Exchange Scheme (MORUSES) during the heat wave from 16, July to 5, August 2018. Two simulations are performed with the late 1980s land-use (EXP1980) and the late 2000s land-use (EXP2000). EXP2000 is verified using Automatic Weather Station (AWS) data from 85 points in the study area, and observation sites are classified into two categories according to the urban fraction change over 20 years; Category A is 0.2 or less increase, and Category B is 0.2 or more increase. The 1.5-m temperature and relative humidity in Category B increase by up to 1.1℃ and decreased by 7% at 1900 LST and 2000 LST, respectively. This means that the effect of the urban fraction changes is higher at night. UHII increases by up to 0.3℃ in Category A and 1.3℃ in Category B at 1900 LST. Analysis of the surface energy balance shows that the heat store for a short time during the daytime and release at nighttime with upward sensible heat flux. As a result of the HI, there is no significant difference between the two experiments during the daytime, but it increases 1.6℃ in category B during the nighttime (2200 LST). The results indicate that the urbanization increase both UHII, and HI, but the times of maximum difference between EXP1980 and EXP2000 are different.

Comparison of Vitality among Three Cool-Season Turfgrasses during Summer using Chlorophyll Fluorescence (엽록소형광을 이용한 한지형 잔디 3종의 하절기 활력도 비교 분석)

  • Koh, Seok Chan
    • Journal of Environmental Science International
    • /
    • v.30 no.7
    • /
    • pp.547-555
    • /
    • 2021
  • To compare the vitality among cool-season turfgrasses under summer weather conditions and to obtain information to improve the management of turfgrasses in golf courses and sports fields., the chlorophyll fluorescence of three cool-season turfgrasses commonly planted on golf courses in the Jeju area was measured. The turfgrasses were perennial ryegrass (Lolium perenne L.), Kentucky bluegrass (Poa pratensis L.), and creeping bentgrass (Agrostis palustris Huds.). In perennial ryegrass and Kentucky bluegrass, the chlorophyll index was low in early summer and high in late summer. In creeping bentgrass, it remained low throughout the study. Fo tended to be low in the early summer and high in late summer in the three turfgrasses. However, the difference in Fo between late summer and early summer was markedly higher in perennial ryegrass than in Kentucky bluegrass or creeping bentgrass. Fm tended to be low in early summer and high in late summer, without obvious differences among the three turfgrasses. Fv/Fm, a measure of photochemical efficiency, was also low in early summer and high in late summer in the three turfgrasses. However, Fv/Fm in late summer was mostly higher in Kentucky bluegrass and creeping bentgrass than in perennial ryegrass, indicating that the former are more resistant to the high temperature and humidity of late summer. Furthermore, Kentucky bluegrass had a high chlorophyll index in late summer and would be most resistant to the harsh conditions of late summer.

An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp (초정압 방전램프(UCD)를 적용한 안전 조명 장치에 관한 연구)

  • Jeong, Poong-Gi;Kim, Young-Chul
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.11a
    • /
    • pp.63-80
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

  • PDF

Influence of Feeding Enzymatically Hydrolyzed Yeast Cell Wall on Growth Performance and Digestive Function of Feedlot Cattle during Periods of Elevated Ambient Temperature

  • Salinas-Chavira, J.;Arzola, C.;Gonzalez-Vizcarra, V.;Manriquez-Nunez, O.M.;Montano-Gomez, M.F.;Navarrete-Reyes, J.D.;Raymundo, C.;Zinn, R.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.9
    • /
    • pp.1288-1295
    • /
    • 2015
  • In experiment 1, eighty crossbred steers ($239{\pm}15kg$) were used in a 229-d experiment to evaluate the effects of increasing levels of enzymatically hydrolyzed yeast (EHY) cell wall in diets on growth performance feedlot cattle during periods of elevated ambient temperature. Treatments consisted of steam-flaked corn-based diets supplemented to provide 0, 1, 2, or 3 g EHY/hd/d. There were no effects on growth performance during the initial 139-d period. However, from d 139 to harvest, when 24-h temperature humidity index averaged 80, EHY increased dry matter intake (DMI) (linear effect, p<0.01) and average daily gain (ADG) (linear effect, p = 0.01). There were no treatment effects (p>0.10) on carcass characteristics. In experiment 2, four Holstein steers ($292{\pm}5kg$) with cannulas in the rumen and proximal duodenum were used in a $4{\times}4$ Latin Square design experiment to evaluate treatments effects on characteristics of ruminal and total tract digestion in steers. There were no treatment effects (p>0.10) on ruminal pH, total volatile fatty acid, molar proportions of acetate, butyrate, or estimated methane production. Supplemental EHY decreased ruminal molar proportion of acetate (p = 0.08), increased molar proportion of propionate (p = 0.09), and decreased acetate:propionate molar ratio (p = 0.07) and estimated ruminal methane production (p = 0.09). It is concluded that supplemental EHY may enhance DMI and ADG of feedlot steers during periods of high ambient temperature. Supplemental EHY may also enhance ruminal fiber digestion and decrease ruminal acetate:propionate molar ratios in feedlot steers fed steam-flaked corn-based finishing diets.

An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp (초정압 방전램프(UCD)를 적용한 안전조명 장치에 관한 연구)

  • Jeong, Poong-Gi;Kim, Young-Chul
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.41-51
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

A Study on Acute Effects of Ambient Air Particles on Pulmonary Function of Schoolchildren in Ulsan

  • Yu, Seung-Do;Kim, Dae-Seon;Cha, Jung-Hoon;Ahn, Seung-Chul;Lee, Jong-Tae
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.183-186
    • /
    • 2003
  • To evaluate the effect of air pollution on respiratory health in children, we conducted a longitudinal study in which children were asked to record their daily levels of peak expiratory flow rate using potable peak flow meter (mini-Wright) far 4 weeks. The relationship between daily PEFR and ambient air particle levels was analyzed using a mixed linear regression models including gender, age in you, weight, the presence of respiratory symptoms, and relative humidity as an extraneous variable. The daily mean concentrations of PM$\_$10/ and PM$\_$2.5/ over the study period were 64.9$\mu\textrm{g}$/㎥ and 46. l$\mu\textrm{g}$/㎥, respectively. The range of daily measured PEFR in this study was 170-481 l/min. Daily mean PEFR was regressed with the 24-hour. average PM$\_$10/ (or PM$\_$2.5/) levels, weather information such as air temperature and relative humidity, and individual characteristics including sex, weight, and respiratory symptoms. The analysis showed that the increase of air particle concentrations was negatively associated with the variability in PEFR. We estimated that the IQR increment of PM$\_$10/ or PM$\_$2.5/ were associated with 1.5 l/min (95% Confidence intervals -3.1, 0.1) and 0.8 l/min (95% Cl -1.8, 0.1) decline in PEFR. Even though this study shows negative findings on the relationship between respiratory function and air particles, it is worth noting that the findings must be interpreted cautiously because exposure measurement based on monitoring of ambient air likely results in misclassification of true exposure levels and this is the first Korean study that PM$\_$2.5/ measurement is applied as an index of air particle quality.

  • PDF

Design of Energy Model of Greenhouse Including Plant and Estimation of Heating and Cooling Loads for a Multi-Span Plastic-Film Greenhouse by Building Energy Simulation (건물에너지시뮬레이션을 활용한 연동형 온실 및 작물에너지모델 설계 및 이의 냉·난방부하 산정)

  • Lee, Seung-No;Park, Se-Jun;Lee, In-Bok;Ha, Tae-Hwan;Kwon, Kyeong-Seok;Kim, Rack-Woo;Yeo, Uk-Hyeon;Lee, Sang-Yeon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.123-132
    • /
    • 2016
  • The importance of energy saving technology for managing greenhouse was recently highlighted. For practical use of energy in greenhouse, it is necessary to simulate energy flow precisely and estimate heating/cooling loads of greenhouse. So the main purpose of this study was to develope and to validate greenhouse energy model and to estimate annual/maximum energy loads using Building Energy Simulation (BES). Field experiments were carried out in a multi-span plastic-film greenhouse in Jeju Island ($33.2^{\circ}N$, $126.3^{\circ}E$) for 2 months. To develop energy model of the greenhouse, a set of sensors was used to measure the greenhouse microclimate such as air temperature, humidity, leaf temperature, solar radiation, carbon dioxide concentration and so on. Moreover, characteristic length of plant leaf, leaf area index and diffuse non-interceptance were utilized to calculate sensible and latent heat exchange of plant. The internal temperature of greenhouse was compared to validate the greenhouse energy model. Developed model provided a good estimation for the internal temperature throughout the experiments period (coefficients of determination > 0.85, index of agreement > 0.92). After the model validation, we used last 10 years weather data to calculate energy loads of greenhouse according to growth stage of greenhouse crop. The tendency of heating/cooling loads change was depends on external weather condition and optimal temperature for growing crops at each stage. In addition, maximum heating/cooling loads of reference greenhouse were estimated to 644,014 and $756,456kJ{\cdot}hr^{-1}$, respectively.

Changes in the Climate in recent 60 years and Distribution of Agroclimatic Resources in Korea (우리나라 최근(最近) 60년(年의) 기후변화(氣候變化)에 따른 농업기후자원(農業氣候資源) 분포(分布))

  • Lee, Jeong-Taek;Yun, Seong-Ho;Park, Moo-Eon
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.2
    • /
    • pp.160-167
    • /
    • 1994
  • Meteorological elements such as air temperature, relative humidity, rainfall, sunshine duration, and so on observed by Korea Meteorological Administration, were analyzed to estimate the climatic change and to establish countermeasures in agriculture. Climatic differences were compared between two periods, early($1931{\sim}1960$) and late($1961{\sim}1990$), by calculating climatic resource indices, coldness index and warmth index of the two periods. Annual mean air temperatures of Seoul, Taegu, and Pusan in 1910's were 10.7, 12.3, and $13.4^{\circ}C$, respectively, having increased by $1.3^{\circ}C$ in Seoul and Taegu and by $0.9^{\circ}C$ in Pusan in 1990's. Mean air temperature in the spring($March{\sim}May$) increased by $0.69^{\circ}C$, which is a higher increasing rate than in the other seasons ($0.26{\sim}0.33^{\circ}C$). Regional differences exist in annual mean air temperature between the early and late part of the 20th century with little increase in this experiment did not germinate at pH 1.0. At pH 2.0, the flowering cabbage and geranium in the middle northern area, while in the southern part about $1^{\circ}C$increase was recorded during the last period. In the late period the annual rainfall increased by 100mm, except for the western coast area and the middle northern area. The P/E ratio showed a trend of an annual increase in the late period, being higher in the summer and lower in the winter. Relative humidity showed slight differences in seasons and regions but annual values did not. Duration of sunshine decreased by about an hour in the spring. Coldness index and warmth index of the late period were higher by 3.7 and 1.0 than those of the early period, respectively.

  • PDF

The Effect of Fluidized-Bed Variables on Attrition of Solid Particles (유동층 공정변수의 고체입자 마모에 미치는 영향)

  • Moon, Young-Sub;Yi, Chang-Keun;Son, Jae-Ek;Ryu, Chung-Keol;Choi, Jeong-Hoo
    • Applied Chemistry for Engineering
    • /
    • v.16 no.5
    • /
    • pp.603-608
    • /
    • 2005
  • This study was conducted to investigate particle attrition characteristics in a gas desulfurization using zinc titanate sorbent in a 0.035 m i.d. by 1.34 m height gas fluidized bed reactor. Gas jetting from the distributor and bubbling in the gas fluidized bed were found to be the main causes of particle attrition. The experiment was carried out under a slow attrition rate condition to compare the performance of the batch reactor to that of a continuous reactor. The attrition index (AI) and corrected attrition index (CAI) were measured at various the gas velocity, temperature, pressure, and bed weight, in the gas fluidized bed, during the dexulfurization process. The AI (5) and CAI (5) decreased as the bed weight increased. Particle destruction occurred when the particles started to experience physical fatigue under specific impacts over several iterations. AI (5) and CAI (5) also increased as relative humidity, gas velocity and pressure increased, and as temperature decreased. Particle attrition was mainly affected by gas jetting from the distributor, and abrasion resulted in smaller particles than fragmentation did.