• Title/Summary/Keyword: Temperature window

Search Result 431, Processing Time 0.024 seconds

3D Visualization System for Realtime Environmental Data (실시간 환경데이터를 이용한 3차원 시각화 시스템)

  • Kim, Jong-Chan;Kim, Kyeong-Ok;Kim, Eung-Kon;Kim, Chee-Yong
    • Journal of Digital Contents Society
    • /
    • v.9 no.4
    • /
    • pp.707-715
    • /
    • 2008
  • The ocean ecosystem and the marine farms were damaged after latest oil spill in Taean. They suffered heavily due to the expansion of the red tide on the coast and the sudden changes in water temperature. We should develop the way to deal with various factors to reduce the damage. In this paper, real time data with which are supplied us through many kinds of sensors on measure equipments will be processed to the visualized shape. Simple numeric data and 2D graph will be changed 2D or 3D graphic objects and animations using WPF, a new effect method in user interface area. This visualization system for environmental data shows us various pictures and offers multimedia data communication.

  • PDF

Rapid Grain Growth of $SrBi_2Nb_2O_9$ Thin Films for Improving Programming Characteristics of Ferroelectric Gate Field Effect Transistor (강유전체게이트 전계효과 트랜지스터의 정보저장특성 향상을 위한 $SrBi_2Nb_2O_9$ 박막의 급속 결정성장방법)

  • Lee, Chang-Woo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.4 s.37
    • /
    • pp.339-343
    • /
    • 2005
  • Pt-$SrBi_2Nb_2O_9(SBN)-Pt-Y_2O_3-Si$ gate field effect transistors (MFMISFETs) have been fabricated and the SBN thin films are rapid thermal annealed in oxygen plasma. The grain size of the SBN becomes 4 times much larger than that of furnace annealed SBN films even at the same annealing temperature of $700^{\circ}C$, remnant polarization value of Pt-SBN-Pt is improved by 2 times. Using the rapid grain growth of SBN for the MFM-ISFET, memory window and programming characteristics of on/off states are fairly well improved.

  • PDF

Numerical Analysis of Natural Convection and Surface Radiation in a Square Enclosure (정사각형 밀폐공간내에서의 자연대류와 표면복사의 수치해석)

  • 권용일;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.983-991
    • /
    • 1992
  • This investigation is carried out numerically for the two dimensional natural convection and surface radiation heat transfer in a square enclosure. The bottom and top walls are isothermal at hot and cold temperatures respectively whereas the left and right side walls are adiabatic except a transparent window on the right side partially. The exchange of radiant energy is obtained by the net radiation method and the shape factor by the crossed string method. The changes in temperature and Nusselt number distributions of the walls due to the surface radiation and insolation are also investigated.

The Experiment on The Efficiency of Heating System for Improving Farm Houses (농촌주택 개량을 위한 난방 효율 시험)

  • 이회만;최예환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.2
    • /
    • pp.3395-3409
    • /
    • 1974
  • The purpose of this study is to test and compare the efficiency of heating-system for materials and construction of the wall, ceiling and window in soil brick house, cement house and boulder house respectively, in order to construct ideal farm houses in rural area. The results obtained were as follows: 1. In heat conservation due to construction of walls the thermal efficiency of cement brick house was equivalent to 66.3% of that of soil brick house, and boulder house 60.3% 2. In the case of ceiling, the thermal efficiency of paper ceiling was amounted to 84.2% of that of the composite ceiling (thickness 6mm veneer+thickness. l0m chaffs), and the common ceiling putting on soil above the ceiling, 76% of the composite while the efficiency of the ceiling putting on chaffs above them was 15.8% higher than that of the paper. 3. In the case of improving the window, the double type was 12% higher than. the efficiency of single type. 4. The warming velocity of conventional house was slower but the velocity of radiation was quicker than that of experimental one. It was thought to be due to unscietific constructions of the room bottom, fire inlet and chimney, 5. The temperature gradient line was not dependad upon the amount of throwing into fuel in the rural farm house. 6. It was concluded that the final thermal efficiency of the conventional farm house was 10.6% lower than that of experimental farm house.

  • PDF

Characteristics of spatial distribution of cold cathode type large aperture electron beam (냉음극형 대면적 전자빔의 공간적 분포 특성)

  • Woo, S.H.;Abroyan, M.;Cho, C.H.;Kim, G.H.;Lee, H.S.;Rim, G.H.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2170-2172
    • /
    • 1999
  • A low energy large aperture(LELA) pulsed electron beam generator of a cold cathode type has been developed for environmental applications, for example, waste water cleaning, flue gas cleaning, and pasteurization etc. The operational principle is based on the emission of secondary electrons from cold cathode when ions in the plasma hit the cathode, which are accelerated toward exit window by the gradient of an electric potential. We have fabricated the LELA electron beam generator with the peak energy of 200keV and beam diameter of 200mm and obtained the large aperture electron beam in air. The electron beam current density has been investigated as a function of glow discharge current, accelerating voltage and radial distribution in front of the exit window foil. The plasma density and electron temperature have been measured in order to confirm the relation with the electron beam current density. We are going to upgrade the LELA electron beam generator in the electron energy, electron beam current and stability of operation for various applications.

  • PDF

The Performance Evaluation of R407C and R410B in a Residential Window Air-Conditioner

  • Kim, Man-Hoe;Shin, Jeong-Seob;Kim, Kwon-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.148-157
    • /
    • 1998
  • This study presents test results of a residential window air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests has been carried out for the basic and liquid-suction heat exchange cycles in a psychometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-suction heat exchange cycle was also considered to improve the system performance. Test results were compared with those for the basic R22 system. The modified system with a liquid-suction heat exchanger increased cooling capacity and energy efficiency by up to 5%.

  • PDF

Optimal Design of Passenger Airbag Door System Considering the Tearseam Failure Strength (티어심 파손 강도를 고려한 동승석 에어백 도어시스템의 최적 설계)

  • Choi, Hwanyoung;Kong, Byungseok;Park, Dongkyou
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.3
    • /
    • pp.60-68
    • /
    • 2021
  • Invisible passenger airbag door system of hard panel types must be designed with a weakened area such that the side airbag will deploy through the instrument panel as like intended manner, with no flying debris at any required operating temperature. At the same time, there must be no cracking or sharp edges in the head impact test. If the advanced airbag with the big difference between high and low deployment pressure ranges are applied to hard panel types of invisible passenger airbag (IPAB) door system, it becomes more difficult to optimize the tearseam strength for satisfying deployment and head impact performance simultaneously. It was introduced the 'Operating Window' idea from quality engineering to design the hard panel types of IPAB door system applied to the advanced airbag for optimal deployment and head impact performance. Zigzab airbag folding and 'n' type PAB mounting bracket were selected.

Quality Variable Prediction for Dynamic Process Based on Adaptive Principal Component Regression with Selective Integration of Multiple Local Models

  • Tian, Ying;Zhu, Yuting
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.4
    • /
    • pp.1193-1215
    • /
    • 2021
  • The measurement of the key product quality index plays an important role in improving the production efficiency and ensuring the safety of the enterprise. Since the actual working conditions and parameters will inevitably change to some extent with time, such as drift of working point, wear of equipment and temperature change, etc., these will lead to the degradation of the quality variable prediction model. To deal with this problem, the selective integrated moving windows based principal component regression (SIMV-PCR) is proposed in this study. In the algorithm of traditional moving window, only the latest local process information is used, and the global process information will not be enough. In order to make full use of the process information contained in the past windows, a set of local models with differences are selected through hypothesis testing theory. The significance levels of both T - test and χ2 - test are used to judge whether there is identity between two local models. Then the models are integrated by Bayesian quality estimation to improve the accuracy of quality variable prediction. The effectiveness of the proposed adaptive soft measurement method is verified by a numerical example and a practical industrial process.

A Study on LVTSCR-Based N-Stack ESD Protection Device with Improved Electrical Characteristics (향상된 전기적 특성을 지닌 LVTSCR 기반의 N-Stack ESD 보호소자에 관한 연구)

  • Jin, Seung-Hoo;Woo, Je-Wook;Joung, Jang-Han;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.168-173
    • /
    • 2021
  • In this paper, we propose a new structure of ESD protection device that achieves improved electrical characteristics through structural change of LVTSCR, which is a general ESD protection device. In addition, it applies N-Stack technology for optimized design in the ESD Design Window according to the required voltage application. The N-Well area additionally inserted in the existing LVTSCR structure provides an additional ESD discharge path by electrically connecting to the anode, which improves on-resistance and temperature characteristics. In addition, the short trigger path has a lower trigger voltage than the existing LVTSCR, so it has excellent snapback characteristics. In addition, Synopsys' T-CAD Simulator was used to verify the electrical characteristics of the proposed ESD protection device.

Preparation of Field Effect Transistor with $(Bi,La)Ti_3O_{12}$ Gate Film on $Y_2O_3/Si$ Substrate

  • Chang Ho Jung;Suh Kwang Jong;Suh Kang Mo;Park Ji Ho;Kim Yong Tae;Chang Young Chul
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.1 s.34
    • /
    • pp.21-26
    • /
    • 2005
  • The field effect transistors (FETs) were fabricated ell $Y_2O_3/Si(100)$ substrates by the conventional memory processes and sol-gel process using $(Bi,La)Ti_3O_{12}(BLT)$ ferroelectric gate materials. The remnant polarization ($2Pr = Pr^+-Pr^-$) int Pt/BLT/Pt/Si capacitors increased from $22 {\mu}C/cm^2$ to $30{\mu}C/ cm^2$ at 5V as the annealing temperature increased from $700^{\circ}C$ to $750^{\circ}C$. There was no drastic degradation in the polarization values after applying the retention read pulse for $10^{5.5}$ seconds. The capacitance-voltage data of $Pt/BLT/Y_2O_3/Si$ capacitors at 5V input voltage showed that the memory window voltage decreased from 1.4V to 0.6V as the annealing temperature increased from $700^{\circ}C$ to $750^{\circ}C$. The leakage current of the $Pt/BLT/Y_2O_3/Si$ capacitors annealed at $750^{\circ}C$ was about $510^{-8}A/cm^2$ at 5V. From the drain currents versus gate voltages ($V_G$) for $Pt/BLT/Y_2O_3/Si(100)$ FET devices, the memory window voltages increased from 0.3V to 0.8V with increasing tile $V_G$ from 3V to 5V.

  • PDF