• Title/Summary/Keyword: Temperature window

Search Result 431, Processing Time 0.031 seconds

한지창호의 실내 온.습도 조절효과에 관한 실험적 연구 (An Experimental Study on the Effect of Hanji Windows on Indoor Air Temperature and Humidity Control)

  • 장길수;박사근;송민정;신훈
    • 한국주거학회논문집
    • /
    • 제17권2호
    • /
    • pp.125-134
    • /
    • 2006
  • The tightness of windows have devoted to the improvement of thermal insulation and energy saving in buildings. But it is known that this tightness causes some side effects such as low ventilation, low capacity to humidity and temperature control and these are not profitable for inhabitants. To act on these side effects, Korean traditional windows which are composed of Han-Ji(Koreand traditional paper) and Chang-Sal(Korean traditional wooden frame) have been studied to get a reasonable solutions for these problems. In this study, to compare the thermal and humidity control performance of current window(12 mm pair) and Korean traditional windows, frames which are made of existing window and Korean traditional windows are adapted to scale model house and then humidity and temperature of in and out of scale model house are measured and analysed. The results of this study are followings ; 1) When Korean traditional window charges 20cm(1/8 of total window area) from total window area, Han-Ji window has higher thermal insulation than that of existing window in daytime. There is the most big thermal difference when double faced with double-ply Han-Ji window is placed to mock-up house. In night-time, the temperature difference is very small so this means that Korean traditional window is good to cover direct sunlight in daytime and reduce the temperature of balcony. One faced with one-ply han-Ji window has the best humidity penetration performance among three type of Korean traditional windows. 2) When Korean window area enlarged to 40cm(1/4 of total window area), the function of 40cm width Han-Ji window is higher than that of 20cm's. This means that enlargement of Han-Ji window cover direct sunlight more and is more efficient in humidity penetration.

자동차 후면 유리 열선의 열전달특성에 따른 성애제거 성능평가 및 성능검증 방법에 관한 연구 (A Study on the Performance Test and Verification of Heat Transfer characteristics in Automobile Rear Window Heater)

  • 전환영;이찬규;배효준;이상재
    • 동력기계공학회지
    • /
    • 제9권2호
    • /
    • pp.73-80
    • /
    • 2005
  • Both theoretical and experimental investigations were conducted to analyze defrosting behavior of a window heater operating in the low outdoor temperature($-20^{\circ}C$). To achieve this purpose, first a warm-chamber experiment($23^{\circ}C$) was performed to measure inner and outer surface temperature of the rear window(heated by the electric heater supplying 195 W) as functions of both time and position. Secondly, a cold chamber experiment was made to continuously record defrosting process of the frosted window. From the comparisons of the two experimental results, it was found that there was a similarity between the spatial distributions of both temperature and remaining frost. Thus, the temperature data from the warm-chamber experiments can be utilized to predict an expected zone covered with remaining frosts, and this approach can also be adopted in the inspection process in order to economically guarantee optimized performance of the window heater. Finally, an analytical model based on one-dimensional, steady-state heat transfer theories was proposed and successfully predicted the outer surface temperature of the rear window surrounded by cold air($-20^{\circ}C$) for the given operating conditions(heater power, inside and outside heat transfer coefficients, and surrounding air temperature, etc.).

  • PDF

열 차단 필름의 적용에 따른 냉난방 부하 분석에 관한 연구 (A Study on the Analysis of Heating and Cooling Load through Applying Window Film Insulation)

  • 김석현;조영흠
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.47-53
    • /
    • 2013
  • In order to reduce the energy consumption of the building, much effort is being made. The problems are that excessive solar radiation in summer and the heat loss in winter by the increase of window area. To prevent this problems, government limited the window area ratio or the performance of windows in new buildings. In order to reduce energy consumption of the existing buildings, the window film insulation is spotlight because the window film insulation was simple to installation. This study confirmed the performance of the window film insulation and affect to heating & cooling load of buildings. The impact of the window film insulation coating was confirmed by experiment. And this study confirmed the annual heating & cooling load by simulation. As a results, the surface temperature of coated window was higher than the surface temperature of existing window. The window film insulation was increased surface temperature of window. And this study confirmed that the increased surface temperature was slightly affected the room air temperature through experiment of the insulation box. The results of the heating and cooling load by simulation, this study confirmed that the case of coated window film insulation decreased cooling load in summer and increased heating load in winter. Also the annual total heating & cooling load was increased a little in the case of coated the window film insulation.

열처리 온도 및 산화층 두께에 따른 ReRAM 특성 연구 (The Study on the Characteristics of ReRAM with Annealing Temperature and Oxide Thickness)

  • 최진형;이승철;조원주;박종태
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 추계학술대회
    • /
    • pp.722-725
    • /
    • 2013
  • 본 연구에서는 열처리를 하지 않은 소자와 열처리 소자의 기본 특성을 비교, 분석하고 온도에 따른 특성 변화를 확인하였다. 사용된 소자는 상부전극이 Pt/Ti(150nm), 하부전극은 Pt(150nm), 산화층은 $HfO_2$(70nm)이고, 열처리 온도는 $500^{\circ}C$, $850^{\circ}C$ 이다. 측정 소자 성능은 Set/Reset 전압, sensing window(저항상태 차이)다. 측정결과 세 종류의 소자의 기본 특성은 열처리별 온도가 높을수록 Set/Reset전압과 sensing window가 증가하였다. 온도에 따른 기본특성 분석 실험 결과 온도가 증가함에 따라 Set/Reset전압과 sensing window가 감소하였다. Set/Reset 전압의 온도에 따른 변화율은 $850^{\circ}C$ 열처리한 소자가 제일 작았고, sensing window의 변화율은 $500^{\circ}C$ 열처리 소자에서 가장 작은 변화율을 보였다. Set/Reset 전압의 변화율 과 sensing window를 고려했을 때 $500^{\circ}C$ 열처리 소자가 좋은 메모리 특성을 보였다.

  • PDF

효율적인 냉각 방식 선정을 위한 탐색창 냉각 특성 해석 연구 (A Numerical Study on the Cooling Characteristics of Seeker Windows for Selecting Efficient Cooling Method)

  • 김만식;이동민
    • 한국군사과학기술학회지
    • /
    • 제20권2호
    • /
    • pp.246-254
    • /
    • 2017
  • In this paper, cooling characteristics of seeker windows were examined using the Sinda-Fluint software. Various cooling methods were considered to satisfy the limit temperature of the cooled seeker window which would be exposed to excessive aerodynamic heating conditions by varying coolant type and mass flow rate of coolant. Due to the enhanced heat transfer between the coolant and the seeker window, internally cooled seeker window which uses liquid coolant showed lowered temperature distribution in the window compared to internally cooled seeker window which uses gas coolant. External film cooled seeker window also showed good cooling characteristics because it reduces the convective heat flux to the seeker window fundamentally. It was also confirmed that the temperature and the temperature gradient of seeker windows were significantly reduced for the cases which use external film cooling additionally to the gas and liquid cooled seeker window.

3.60wt%C-2.50wt%Si-0.80wt%Cu 조성 오스템퍼드 구상흑연주철의 프로세싱 윈도우에 미치는 열처리 조건의 영향 (Effect of Heat Treatment Condition on the Processing Window of 3.60wt%C-2.50wt%Si-0.80wt%Cu Austempered Ductile Cast Iron)

  • 박정재;서갑성;권해욱
    • 한국주조공학회지
    • /
    • 제29권2호
    • /
    • pp.86-94
    • /
    • 2009
  • The effect of austenitizing temperature and time on the processing window of 3.60wt%C - 2.50wt%Si - 0.80wt%Cu ductile cast iron and that of the amount of copper added were investigated. The second stage reaction at 400oC was retarded with increased austenitizing temperature. The widest processing window was obtained at the lower austempering temperature with the increased time at the same austenitizing temperature. The width of the widest processing window was decreased with the increase of time at the same austenitizing temperature. The width of processing window was increased with the increased amount of copper added.

스팬드럴 부분 BIPV창호 적용 및 후면마감재 구성에 따른 온도특성 분석 연구 (The Evaluation of the Temperature Characteristics at the Spendrels of Curtain wall with a-Si BIPV Window System)

  • 김동수;오명환;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.165-170
    • /
    • 2012
  • This study aims to analyze the characteristics of temperature variation of Spandrels. According to the change of SHGC of Window system, air space, insulation performance and absorption factor of inner surface at the Spandrels, It was firstly estimated by using simulation. Secondly, measured to minimize the temperature-rise of inner surface temperature and the intermediate air temperature by using Full-scale Mock-up based on the result of simulation analysis. As a result, it turns out that low SHGC window system such as BIPV system had an advantage of reducing the window surface temperature, and the surface temperature of clear window system was all higher than BIPV system on simulation results. In the experiment results, it had some advantages of increasing the Spandrels volume, decreasing insulation performance and lower absorption factor.

  • PDF

투명전극을 이용한 display용 김서림 방지장치 개발 (Development of transparent anti-fog window device using ITO)

  • 김창규;유근호
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2008년도 하계학술발표회 논문집
    • /
    • pp.353-354
    • /
    • 2008
  • in the environment with high temperature and humidity, surface temperature of the display window should be increased more than the temperature of water-vapor in order to get rid of fog. In this study, we manufacture anti-fog window device which has better transparence and gets high temperature by using ITO.

  • PDF

표면 온도 저하율에 따른 창호부 결로성능 예측에 관한 연구 (Study on Estimate of Window Condensation performance Due to Temperature Depreciation Ratio)

  • 성욱주;조수;장철용;이진성;백상훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1255-1260
    • /
    • 2006
  • This present study analyzed temperature depreciation ratio of window inside surface by KS F 2295 'Procedure for determining fenestration product condensation resistance values'. it estimated window indoor surface condensation due to variable environmental condition. Performance of condensation resistance by using temperature depreciation ratio until applied Low-e and Ar glazing improved about 45% from 24 mm clear. Temperature depreciation ratio by KS F 2295 considers analytic index of window condensation due to variable boundary condition.

  • PDF

CFD를 이용한 Window Defrosting 평가 (The evaluative study of window defrost using Computational Fluid Dynamics)

  • 이인수;임효남;최재웅
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.179-182
    • /
    • 2011
  • The purpose of this study is to evaluate a defrost model for the possibility of defrosting on wheelhouse window and the heat capacity if defrosting nozzle by using the commercial CFD solver FLUENT. A detailed simulation model has been created which contains the defrosting nozzle, window and the interior/exterior forced convection boundary. In this numerical study, the heat and mass transfer coupled during defrosting and investigated the defrost time for different hot gas temperature, external wind speed and temperature condition.

  • PDF