• Title/Summary/Keyword: Temperature test equipment

Search Result 330, Processing Time 0.029 seconds

An Experimental Study on Quality Management of Strength in High Strength Mass Concrete Structure Using Thermal Insulation Material (보온재를 사용한 고강도 매스 콘크리트의 품질관리에 관한 연구)

  • Cho, Kyu-Hyun;Back, Min-Soo;Kim, Sung-Sik;Lim, Nam-Gi;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.2
    • /
    • pp.113-118
    • /
    • 2004
  • This study is a basic experiment on quality management of the compression strength of high strength concrete, aiming. at quality management of high strength mass concrete by giving the temperature hysteresis of the mass test pieces to managerial test pieces. Different from ordinary concrete, high strength concrete generally shows the temperature high rising caused by hydration heat inside the concrete. It is known that, in mass concrete, thermal stress occurs due to the difference in temperature between the inside and the outside, which causes a significant difference in compression strength between structure beams and managerial test pieces. It is also reported that there is a large difference between the compression strength of cylindrical managerial test pieces of standard underwater curing and the strength of structure beam concrete. Thus, this study made concrete test pieces in an optimal mix ratio for each strength level, and also created thermal insulation curing box and managerial test pieces. Then it carried out comparative analysis in relation to core strength and suggested equipment and a technique that can control the strength of high strength concrete mass more conveniently and accurately.

The Influence of Specimen Volume on the Adiabatic Temperature Rise of Concrete (콘크리트 단열온도 상승량에 미치는 시험체 용적의 영향)

  • Bae, Jun-Young;Cho, Sung-Hyun;Shin, Kyung-Joon;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.659-666
    • /
    • 2012
  • To secure the thermal crack resistance of mass concrete, researches and the field applications of low heat portland cement (LPC), ternary blended cement (TBC) which is produced by blending ordinary portland cement with blast furnace slag and fly ash, and early strength low heat blended cement (EBC) increased in recent years. Although the model for adiabatic temperature rise is necessary for estimating the risk of thermal cracking of concrete structures, sufficient data have not been accumulated for these mixtures. In addition, the differences in adiabatic test results have been reported for the volume of test specimens. Therefore, the present study evaluated the characteristics of adiabatic temperature rise based on the type of binder and the volume of the adiabatic test specimen. Test results indicated that the maximum temperature rise ($Q_{\infty}$) and the reaction factor (r) of TBC were the lowest. Test results also showed that $Q_{\infty}$ and r changed with respect to the volume of test specimen. $Q_{\infty}$ and r obtained from 6l equipment were lower than those of 50l equipment. Therefore, corrections with respect to this phenomenon was confirmed and the corrections factors are presented.

Electrical Machines and Drives for Potentially Explosive Atmospheres

  • Grantham, Colin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.128-134
    • /
    • 2012
  • This paper gives an overview of the requirements for electrical equipment in potentially explosive atmospheres and describes how these are applied to electrical machines and drives in hazardous areas. The method by which equipment can be shown to be safe in a whole range of gases, by testing in a single test gas, is covered. It is shown how the more recently introduced methods of protection for hazardous areas, increased safety and nonsparking, are ideally suited to AC machines and drives. A novel method of measuring the fullload temperature rise of electrical machines for hazardous, and other areas, without the need to connect a mechanical load to the machine's drive shaft is explained.

Tasks for Development of Autogenous Pressurization System and Construction of Test Equipment (자가증기 가압시스템 개발과제 및 모사시험설비 구성)

  • Cheulwoong Kim;Jisung Yoo;Sangyeon Ji;Jae Sung Park
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.27 no.1
    • /
    • pp.49-57
    • /
    • 2023
  • The autogenous pressurization has been widely adopted for propulsion systems of next-generation reusable rockets due to its low cost and high reliability. The autogenous pressurization has a simple structure, but an understanding of the heat and mass transfer occurring inside the tank is essential. For this reason, a simulation test of the autogenous pressurization was conceived. The experiment equipment was constructed based on overseas pressurization test facilities cases and expert advice. Unlike the actual autogenous pressurization system, the propellant tank was insulated to exclude external influences. The pressurized gas supply line and the propellant pipe were separated. Using the manufactured autogenous pressure experiment equipment, it is possible to evaluate the condensation phenomenon of pressurants in cryogenic propellants, comparison of the efficiency of pressurization using helium and evaporated gas and the pressurization capacity according to the temperature of pressurant.

A Development of Test Equipment for Thermal Protection Performance on Insulator used in Solid Rocket Motor (고체로켓 추진기관용 연소관단열재의 내열성능평가를 위한 시험장치 개발)

  • Kang, Yoongoo;Yun, Deokjin;Kim, Suyoung;Lee, Jongsung;Kwon, Taeha
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.543-546
    • /
    • 2017
  • Test equipment was designed and manufactured to evaluate thermal reaction characteristic of internal insulators of solid rocket motor. Test is allowed up to chamber pressure 2,500 psi, burn-time 40 s. It is possible to observe and to compare thermal reaction characteristic for a few materials simultaneously, under the condition that the ablation occurs. In efficient average chamber pressure 878 psi, efficient burn-time 10.7 s and gas velocity 100 m/s, test was executed for confirming safety of equipment, being 4 test materials inserted simultaneously. Basic data for understanding thermal characteristic of internal insulator, that is, pressure-time curve, temperature-time curve in the test sample, and thermal destruction depth of test samples was gained successfully.

  • PDF

Robust fuzzy self-organizing control system of temperature environmental test equipment (온도환경 시험장비의 강인한 퍼지 자기조성 제어 시스템)

  • 김인식;윤일선;남세규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.1086-1088
    • /
    • 1993
  • A robust fuzzy self-organizing controller(SOC) is proposed for an environmental temperature chamber. Although fuzzy SOC can improve the performance of nonlinear system, the controller is ineffective to solve the performance degradation owing to the time varying factors. In this paper, we construct the fuzzy SOC with a predictive scheme based on the 386PC. The usefulness of the proposed scheme is shown through the comparison of the PI controller and the fuzzy controller.

  • PDF

A Study on Wired LogiC for Type Unit for PLC Output Driving (PLC 출력 구동을 위한 Wired Logic for Type Unit에 관한 연구)

  • 위성동;김태성
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.51-57
    • /
    • 1999
  • This thesis is written about the Wired Logic Type Unit in developing equipment that the load is driven, that the interface unit connect with 1 Scan time to PO30 of operated PLC output contact with that a sensing signal of Temperature Sensor RSD Pt $100\Omega$ let generate the relay output of temperature controller and input the PLC. The PLC Test Kit in country that the PLC to be programmed at the PLC education place is able to drive the load, is done to do a education of PLC on status that interface process between PLC and load are disregarded. As Developing Kit for supplement this point, when the relay output of temperature controller to use Pt 100 of temperature sensor as mentioned on the former among every kinds of sensor feed back to the input of the PLC, as the equipment to act with real time system that the output contact of PLC operated to insert the WLTIJ among PC, PLC and the load, it can understand and see very easy the main principle of PLC use. The structure of WLTU to be a interface unit of load separated as to the point of contact and noncontact, sensor, indicating lamp and A contact and B contact that is belong to driving part, and a motor is belong to loading part.

  • PDF

A study on performance of outdoor air flow rate through viovent for hybrid ventilation equipment (자연급기구내 플리머필터 설치 시 외기 침기량 분석에 관한 연구)

  • Yi, Seong-Hwan;Choi, Jong-Ak
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1337-1342
    • /
    • 2009
  • This test was progressed in the test house of KICT as sectional research of Center for Sustainable Housing. It included a ventilation rate of hybrid ventilation equipment, temperature, and gas test using the SF-6. The purpose of this test is to demonstrate the performance of viovent by estimating an outdoor air flow rate through viovent which the flimmer filter is installed and decide the leakage after operating the constant airflow fan within a house. First, the outdoor airflow rate through viovent measured $130\;m^3/h$ more than a legal required ventilation rate, $104\;m^3/h$. And then it sufficiently satisfy a legal standard, 0.7 air change/h. Secondly, the result of this test exposes that the leakage in the residence is about $20{\sim}25%$. Especially, the outdoor air flowing through the gate occupies 50% of the total leakage.

  • PDF

Hydraulic fitting impulse tester development (유압 피팅 충격압시험기 개발)

  • 김형의;이용범
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.917-921
    • /
    • 1991
  • Hydraulic fitting impulse tester is equipment which produce impulse pressure waveform that specified foreign standard of SAE, JIS etc. Test conditions of SAE J1453 about waveform standard indicates frequency of 35-70 cycle/min, pressure of 560 bar, oil temperature of 93 .+-.3.deg. C etc. and required cycle is a million over. In additions, Test condition operated continuously equipment. This development item adopted new pattern method such as intensifier and rotary distributor is different from already established fitting impulse tester applied servo valve and high pressure direct directional control valve. Therefore, this development item which compares already established item is good reliability, low cost of manufacture and save of electric energy. especially, Domestic small and medium enterprise uses this tester because of economical cause. We develope appropriateness tester which conforms to demand of user.

  • PDF

Effect of Grain Size on Corrosion Resistance and High Temperature Oxidation Behavior of 22Cr-15Ni-5W Super Austenitic Stainless Steels (22Cr-15Ni-5W 슈퍼 오스테나이트계(系) 스테인리스강(鋼)의 고온산화(高溫酸化) 및 내식성(耐蝕性)에 미치는 결정립(結晶粒) 크기의 영향(影響))

  • Kim, H.J.;Lee, H.W.;Lee, J.M.;Kang, C.Y.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.51-57
    • /
    • 2006
  • The effect of grain size on corrosion resistance and high temperature oxidation behavior was studied in 22Cr-15Ni-5W super austenitic stainless steels for desulfurization equipment as a heat power station. In the high temperature oxidation test, oxidation rate was increased as the temperature increased from $600^{\circ}C\;to\;800^{\circ}C$. In vapor, oxidation rate was faster than that in air. Because the vapor was inhibited nucleation of $Cr_2O_3$ film. And the high temperature oxidation resistance at $600^{\circ}C{\sim}800^{\circ}C$ was excellent from all specimens and specimen of the smallest grain size was the most excellent. Because increasing of diffusion course through the grain-boundary was promoted nucleation and growth of $Cr_2O_3$ film. In the test temperature at $600^{\circ}C{\sim}800^{\circ}C$, Cr rich round particle oxide was formed in air, whereas Fe rich needle type oxide was developed in vapor.