• Title/Summary/Keyword: Temperature low dependent

Search Result 551, Processing Time 0.029 seconds

Thickness Dependent Temperature Accelerated Dielectric Break-down Strength of On-wafer Low Dielectric Constant Polymer Films

  • Kim, H. K.;Lee, S. W.;F. G. Shi;B. Zhao
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.281-286
    • /
    • 2002
  • The temperature accelerated dielectric breakdown strength of on-wafer low-k dielectric polymer films with thicknesses ranging from 94 nm to 1141 nm is investigated by using the current-voltage characteristic measurements with MIS structures. The temperature dependence of dielectric strength is demonstrated to be Arrhenious for all thicknesses. However, the activation energy is found to be strongly thickness dependent. It follows an exponential relationship rather than being a single value, i.e., the activation energy increase significantly as film thickness increases for the thickness below 500 nm, but it is almost constant for the thickness above 500 nm. This relationship suggests that the change of the activation energy corresponding to different film thickness is closely related to the temperature dependence of the electron trapping/detrapping process in polymer thin films, and is determined by both the trapping rate and the detrapping rate. Thinner films need less energy to form a conduction path compared to thicker films. Hence, it leads to smaller activation energy in thinner films, and the activation energy increases with the increase in film thickness. However, a nearly constant value of the activation energy is achieved above a certain range of film thickness, indicating that the trapping rate and detrapping rate is almost equal and eventually the activation energy approaches the value of bulk material.

Transition from Cycle-Dependent to Time-Dependent Fatigue Crack Propagation at Creep Temperature of SUS 304 Steel (SUS 304鋼 의 크리이프 溫度領域 에 관한 時間依存型 및 사이클依存型 疲勞크랙 傳播 의 遷移)

  • 유헌일;주원식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.539-547
    • /
    • 1985
  • The low-cycle fatigue crack growth behavior of SUS 304 Stainless steel was investigated at 650.deg. C by the nonlinear fracture mechanics. Crack Propagation can be separated in to cycle-dependent and time-dependent, the former is correlated with .DELTA. $J_{f}$ , J-intergral range and the latter is correlated with J', modified J integral. Transition from cycle-dependent to time-dependent crack growth was successfully predicted using the .betha. hypothesis, which was proposed by the authors on the basis of an analysis on the interaction of elastic and creep strain. To investigate the reliability of .betha.-hypothesis, experimenting by the change of stress-level, stress rate and frequency, following conclusions were obtained. (1) High temperature fatigue crack propagation was separated into cycle-dependent and time-dependent. (2) Transition of crack propagation was predicted by .DELTA. $J_{c}$/.DELTA.$_{f}$ or .betha. (3) Lower limit in cycle-dependent crack propagation was obtained..

Temperature Rise Test and Temperature Distribution Analysis of Pole Mount Mold Transformer with One-body Molding (일체형 주상용 몰드 변압기의 온도분포 및 특성 비교)

  • Cho, Han-Goo;Lee, Un-Yong;Kang, Tack-Sou;Choi, In-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1154-1159
    • /
    • 2006
  • The mold transformers have been widely used in underground substations of large building and have some advantages when compared with oil-transformer. Those advantages are low fire risk, environmental compatibility, compact size and high reliability. The mold transformer is generally known to have cooling duct between low voltage and high voltage coil. To achieve better compact structure and low loss, mold transformers made by one body molding method has been developed. Nevertheless, such kinds of transformer need better cooling method because heat radiation between each winding is still of problem. The life of transformer is significantly dependent on the thermal behavior in windings. Many designers have calculated temperature distribution in transformers and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, the temperature distribution analysis of 100 kVA pole mold transformer for power distribution were investigated by FEM program and the thermal analysis results were compared with temperature rise test.

The Design and Performance Test of Mold Transformer for Outdoor Pole (50 kVA 주상용 몰드변압기의 설계 및 특성평가)

  • Cho, Han-Goo;Lee, Un-Yong;HwangBo, Kuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF

LOW CYCLE THERMAL FATIGUE OF THE ENGINE EXHAUST MANIFOLD

  • Choi, B.L.;Chang, H.;Park, K.H.
    • International Journal of Automotive Technology
    • /
    • v.5 no.4
    • /
    • pp.297-302
    • /
    • 2004
  • This paper presents the low cycle thermal fatigue of the engine exhaust manifold subject to thermo-mechanical cyclic loading. As a failure of the exhaust manifold is mainly caused by geometric constraints of the less expanded inlet flange and cylinder head, the analysis is based on the exhaust system model with three-dimensional temperature distribution and temperature dependent material properties. The result show that large compressive plastic deformations are generated at an elevated temperature of the exhaust manifold and tensile stresses are remained in several critical zones at a cold condition. From the repetition of these thermal shock cycles, maximum plastic strain range (0.454%) could be estimated by the stabilized stress-strain hysteresis loops. It is used to predict the low cycle thermal fatigue life of the exhaust manifold for the thermal shock test.

High Efficiency Dye-Sensitized Solar Cells: From Glass to Plastic Substrate

  • Go, Min-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.294-294
    • /
    • 2010
  • Over the last decade, dye-sensitized solar cell (DSSC) has attracted much attention due to the high solar-to-electricity conversion efficiency up to 10% as well as low cost compared with p-n junction photovoltaic devices. DSSC is composed of mesoporous TiO2 nanoparticle electrodes coated with photo-sensitized dye, the redox electrolyte and the metal counter electrode. The performances of DSSC are dependent on constituent materials and interface as well as device structure. Replacing the heavy glass substrate with plastic materials is crucial to enlarge DSSC applications for the competition with inorganic based thin film photovoltaic devices. One of the biggest problems with plastic substrates is their low-temperature tolerance, which makes sintering of the photoelectrode films impossible. Therefore, the most important step toward the low-temperature DSSC fabrication is how to enhance interparticle connection at the temperature lower than $150^{\circ}C$. In this talk, the key issues for high efficiency plastic solar cells will be discussed, and several strategies for the improvement of interconnection of nanoparticles and bendability will also be proposed.

  • PDF

Effect of Room Temperature Ionic Liquids Adsorption on Electromechanical Behavior of Cellulose Electro-Active Paper

  • Mahadeva, Suresha K.;Yi, Chen;Kim, Jae-Hwan
    • Macromolecular Research
    • /
    • v.17 no.2
    • /
    • pp.116-120
    • /
    • 2009
  • The cellulose smart material called electro-active paper (EAPap) is made by regenerating cellulose. However, the actuator performance is degraded at low humidity levels. To solve this drawback, EAPap bending actuators were made by activating wet cellulose films in three different room-temperature ionic liquids: l-butyl-3-methylimidazolium hexaflurophosphate ($BMIPF_6$), 1-butyl-3-methylimidazolium chloride (BMICL) and 1-butyl-3-methylimidazolium tetrafluroborate ($BMIBF_4$). In the results, the actuator performance was dependent on the type of anions in the ionic liquids, in the order of $BF_4$>Cl>$PF_6$. The BMIBF 4-activated actuator showed the maximum displacement of 3.8 mm with low electrical power consumption at relatively low humidity. However, the BMICL-activated actuator showed a slight degradation of actuator performance. Further performance and durability improvement will be possible once various ionic liquids are blended with cellulose.

Characteristics of High Temperature Oxide Thin Film Using Dichlorosilane Gas (Dichlorosilane Gas를 이용한 High Temperature Oxide Thin Film의 특성)

  • 이승석;이석희;김종철;박헌섭;오계환
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.190-197
    • /
    • 1992
  • In this study we have investigated physical and electrical properties of high temperature oxide (HTO) thin film using dichlorosilane (DCS) gas. This film had low etch rate and excellent step coverage, and its characteristics of Si-O bond were similar to those of thermal oxide. I-V curves also showed similar electrical properties to those of thermally grown oxide (SiO2) while time dependent dielectric breakdown (TDDB) results revealed 1/4 value of thermal oxide. However, defect density was measured to be much lower value than that of thermal oxide.

  • PDF

A Study on the Hot Spot Temperature in 154kV Power Transformers

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Woo, Jung-Wook;Kwak, Joo-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.312-319
    • /
    • 2012
  • The life of a power transformer is dependent on the life of the cellulose paper, which influenced by the hot spot temperature. Thus, the determination of the cellulose paper's life requires identifying the hot spot temperature of the transformer. Currently, however, the power transformer uses a heat run test is used in the factory test to measure top liquid temperature rise and average winding temperature rise, which is specified in its specification. The hot spot temperature is calculated by the winding resistance detected during the heat run test. This paper measures the hot spot temperature in the single-phase, 154kV, 15/20MVA power transformer by the optical fiber sensors and compares the value with the hot spot temperature calculated by the conventional heat run test in the factory test. To measure the hot spot temperature, ten optical fiber sensors were installed on both the high and low voltage winding; and the temperature distribution during the heat run test, three thermocouples were installed. The hot spot temperature shown in the heat run test was $92.6^{\circ}C$ on the low voltage winding. However, the hot spot temperature as measured by the optical fiber sensor appeared between turn 2 and turn 3 on the upper side of the low voltage winding, recording $105.9^{\circ}C$. The hot spot temperature of the low voltage winding as measured by the optical fiber sensor was $13.3^{\circ}C$ higher than the hot spot temperature calculated by the heat run test. Therefore, the hot spot factor (H) in IEC 60076-2 appeared to be 2.0.

Drying Characteristics and Drying Model of Red Pepper (고추의 건조특성(乾燥特性)과 건조모델에 관(關)한 연구(硏究))

  • Cho, Y.J.;Koh, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.11 no.1
    • /
    • pp.52-63
    • /
    • 1986
  • This study was performed to find out drying characteristics and develop drying model for the design of an efficient dryer or drying system of red peper. The basic model which describes drying phenomenon of red pepper was firstly established, and drying tests were conducted at 14-different drying conditions. In this test, the effects of drying air temperature and relative humidity on the rate of drying were undertaken. Finally, a new drying model based on these experimental results was developed to describe the drying characteristics of red pepper. The results from this study may be summarized as follows. 1. Drying constant of the basic model established from Lewis' experimental model and diffusion equation was theoretically deduced as a function of moisture content and inner-temperature of red pepper. 2. From the results of drying tests, drying air temperature was found to have the greatest effect on the rate of drying. However, the effect of temperature was small for the condition of high relative humidity, and for low temperature, the effect of relative humidity was found to be large even though the range of relative humidity was low. 3. Modified Henderson equation was found to be better than Chung equation as the EMC model for the estimation of the equilibrium moisture content of red Pepper. 4. Constant-rate drying period did not exist in the red pepper drying test. And falling-rate drying period was divided into three distinct phases. Drying rate was dependent on the moisture content, the inner-temperature of red pepper and the change of physical property due to drying. 5. Drying constant increased with decrease of free moisture content, but it decreased at the end of the drying period. Also, drying constant was dependent on the drying air temperature and relative humidity. 6. The new drying model developed in this study was found to be most suitable in describing the drying characteristics of red pepper. Therefore, it may be concluded that drying time could be accurately estimated by the new drying model.

  • PDF