A Study on the Calibration Technique of an Electrical Temperature Calibrator (전기식 온도 교정기 교정기법 연구)

  • Oh, Kwang-Suk;Lee, Wang-Heon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.11
    • /
    • pp.944-951
    • /
    • 2016
  • Resistance temperature detectors (RTDs) and thermocouple sensors are broadly used to measure temperatures in the engineering and research fields. The contents of this standard calibration procedure (SCP) describe procedures related to the calculation of an electrical temperature calibrator and show different ways to indicate the calibration results, such as measurement uncertainty. As an SCP for the electrical temperature calibrator has not been developed yet, we studied the SCP and found a solution to this problem. In this paper, we present a mathematical model of the data and measurement variations with the calibration data results.

Calibration of Strain Gauge for Thermal Expansion Coefficientof Fiber Reinforced Composites at Cryogenic Temperature (극저온 환경에서의 섬유강화 복합재료의 열팽창 계수 측정을 위한스트레인 게이지의 보정에 관한 연구)

  • Lee, Won-Oh;Lee, Sang-Bok;Yi, Jin-Woo;Um, Moon-Kwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.1-6
    • /
    • 2010
  • Since the fiber reinforced polymeric (FRP) composites are considered in next generation of space transportation systems, reliable thermal expansion properties should be well provided for structural design of composite materials. To obtain accurate mechanical behaviors at a cryogenic temperature, precise strain measurement and calibration must be provided. In this work, apparent strains (or thermal output) of temperature self-compensated strain gages were deliberately investigated for epoxy, CTBN modified epoxy and carbon fabric composite system from room temperature to liquid nitrogen temperature. Also, fourth-order thermal output curves were presented for the further calibration. The results showed that the thermal output is heavily dependent on test materials and a large amount of apparent strains were observed for the polymer resins.

Development and Application of the Calibration Method of Individual Building Energy Consumption (개별건물 에너지소비량 보정기법 개발 및 적용방안)

  • Kim, Dongil;Lee, Byeongho
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.15-24
    • /
    • 2020
  • Building energy consumption generally depends on living patterns of residents and outdoor air temperature changes. Although outdoor air temperature changes effect on building energy consumption, there is no calibration method for the comparison before and after Green Remodeling or BEMS installation etc., Big data of building energy consumption are collected and managed by 『National Integrated Management System of Building Energy』 in Korea, and they are utilized for the development of a calibration method for individual buildings as shown as the calibration method for small-area building stocks in the previous research. This study aims to develope a calibration method using big data of building energy consumption of individual buildings and outdoor air temperature changes, and to propose application of appropriate calibration methods for individual buildings or small-area building stocks according to the calibration purpose and conditions.

A Study on Calibration of Heat Flux Sensor by using Convective Heat Transfer (대류방식을 이용한 열유속센서의 검정에 관한 연구)

  • Yang, Hoon-Cheul;Song, Chul-Hwa;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1358-1363
    • /
    • 2004
  • The objective of this work is to propose calibration facility in which a thin film type heat flux sensor can be calibrated under convective flow condition by using a small wind tunnel with the constant temperature plate condition. A small wind tunnel has been built to produce a boundary layer shear flow above a constant temperature copper plate. 12-independent copper blocks, thin film heaters, insulators and temperature controllers were used to keep the temperature of flat plate constant at a specified temperature. Three commercial thin film-type heat flux sensors were tested. Convective calibrations of these gages were performed over the available heat flux range of $1.4{\sim}2.5kW/m^2$. The uncertainty in the heat flux measurements in the convective-type heat flux calibration facility was ${\pm}2.07%$. Non-dimensional sensitivity is proposed to compare the sensitivity calibrated by manufacturer and that of experiment conducted in this study.

  • PDF

Study on the Partially Premixed Flames Produced by a Coflow Burner as Temperature Calibration Source (동축류 버너에서 생성된 부분 예혼합 화염을 이용한 화염 온도 측정 검정원 연구)

  • Park, Chul-Woung;Hahn, Jae-Won;Shin, Hyun-Dong
    • Journal of the Korean Society of Combustion
    • /
    • v.5 no.1
    • /
    • pp.91-98
    • /
    • 2000
  • We investigated a uniform temperature zone, produced by double flame structure of a co flow CH4/air partially premixed flame, to be used as a temperature calibration source for laser diagnostics. A broadband N2 CARS(coherent anti-Stokes Raman spectroscopy) system with a modeless laser was used for temperature measurement. When the stoichiometric ratio was 1.5, we found the uniform temperature zone in radial direction of the flame of which the averaged temperature was 2110 K with standard deviation 24 K. In the stoichiometric ratio range between 2.0 and 2.5, we found very stable temperature-varying zones in vertical direction at the center of the flame. The size of the zone was approximately 15 mm and it covered a temperature range from 300 K to 1900 K. We also suggest that this zone can be used as a calibration source for 2-D PLIF(planar laser induced flurescence) temperature measurement.

  • PDF

Automated Cold Volume Calibration of Temperature Variation in Cryogenic Hydrogen Isotope Sorption Isotherm (극저온(20K) 수소동위원소 흡착 등온선의 온도 변화에 대한 자동 저온 부피 교정)

  • Park, Jawoo;Oh, Hyunchul
    • Korean Journal of Materials Research
    • /
    • v.29 no.5
    • /
    • pp.336-341
    • /
    • 2019
  • The gas adsorption isotherm requires accurate measurement for the analysis of porous materials and is used as an index of surface area, pore distribution, and adsorption amount of gas. Basically, adsorption isotherms of porous materials are measured conventionally at 77K and 87K using liquid nitrogen and liquid argon. The cold volume calibration in this conventional method is done simply by splitting a sample cell into two zones (cold and warm volumes) by controlling the level sensor in a Dewar filled with liquid nitrogen or argon. As a result, BET measurement for textural properties is mainly limited to liquefied gases (i.e. $N_2$ or Ar) at atmospheric pressure. In order to independently investigate other gases (e.g. hydrogen isotopes) at cryogenic temperature, a novel temperature control system in the sample cell is required, and consequently cold volume calibration at various temperatures becomes more important. In this study, a cryocooler system is installed in a commercially available BET device to control the sample cell temperature, and the automated cold volume calibration method of temperature variation is introduced. This developed calibration method presents a reliable and reproducible method of cryogenic measurement for hydrogen isotope separation in porous materials, and also provides large flexibility for evaluating various other gases at various temperature.

Variable Temperature Cryostat for Cryogenic Temperature Sensor Calibration

  • Kim, Myung Su;Choi, Yeon Suk;Kim, Dong Lak
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.4
    • /
    • pp.46-49
    • /
    • 2012
  • The selection of the temperature sensor in the cryogenic system depends on the temperature range, shape and accuracy. The accuracy of the temperature sensor is essential to improve the reliability of experiment. We have developed the variable temperature cryostat using a two-stage cryocooler. In order to reduce heat load, thermal shield is installed at the first stage with MLI (Multiple layer insulation). We have also developed the sensor holder calibrating more than twenty sensors at the same time for saving time and money. The system can calibrate sensor at variable temperature by controlling electric heater. In this paper, we present design and fabrication of variable temperature cryostat and representative result of Cernox sensor calibration.

Measurement of local wall temperature and heat flux using the two-thermocouple method for a heat transfer tube

  • Ahn, Taehwan;Kang, Jinhoon;Jeong, Jae Jun;Yun, Byongjo
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1853-1859
    • /
    • 2019
  • The two-thermocouple method was investigated experimentally to evaluate its accuracy for the measurement of local wall temperature and heat flux on a heat transfer tube with an electric heater rod installed in an annulus channel. This work revealed that a thermocouple flush-mounted in a surface groove serves as a good reference method for the accurate measurement of the wall temperature, whereas two thermocouples installed at different depths in the tube wall yield large bias errors in the calculation of local heat flux and wall temperature. These errors result from conductive and convective changes due to the fin effect of the thermocouple sheath. To eliminate the bias errors, we proposed a calibration method based on both the local heat flux and Reynolds number of the cooling water. The calibration method was validated with the measurement of local heat flux and wall temperature against experimental data obtained for single-phase convection and two-phase condensation flows inside the tube. In the manuscript, Section 1 introduces the importance of local heat flux and wall temperature measurement, Section 2 explains the experimental setup, and Section 3 provides the measured data, causes of measurement errors, and the developed calibration method.

Distortion Correction of Surface Temperature Measurement Using an Infrared Camera (적외선 카메라를 이용한 표면온도측정의 왜곡 보정)

  • Lee, Sungmin;Kim, Ikhyun;Lee, Jong Kook;Byun, Yunghwan;Park, Gisu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.7
    • /
    • pp.545-551
    • /
    • 2016
  • Surface temperature of supersonic wind tunnel model was measured using an infrared thermography technique. To measure the temperature quantitatively, various calibration techniques such as blackbody calibration which converts detected camera signal to temperature, distortion correction due to the camera lens and an imbalance of camera pose, and emissivity calibration which considers viewing angles to the model surface, were employed. Throughout the study, for the quantitative as well as qualitative surface temperature measurement, it was verified that the distortion correction must be considered even for the use of two-dimensional model in aerodynamics testing.

A New Liquid Crystal Color Calibration Technique Using Neural Networks and Median Filtering

  • Lee, Dae-Hee;Chung, Jae-Hun;Won, Se-Youl;Kim, Yun-Taek;Boo, Kwang-Suk
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.113-120
    • /
    • 2000
  • This study has developed a new liquid crystal calibration technique using Neural networks with median filtering and applied this technique to heat transfer measurements. To verify the validity of this new measurement technique, the local Nusselt numbers on a flat plate surface subjected to an axisymmetric impinging jet were measured and compared with the results by the conventional Hue-temperature calibration technique under the same conditions. Because the Neural networks predict the non-linear relations between temperatures and corresponding R, G, B values, Neural networks-median filtering calibration technique can utilize a much wider color band in the experiment than the Hue-temperature calibration technique, resulting in a significant reduction in the experimental time.

  • PDF