Abstract
Surface temperature of supersonic wind tunnel model was measured using an infrared thermography technique. To measure the temperature quantitatively, various calibration techniques such as blackbody calibration which converts detected camera signal to temperature, distortion correction due to the camera lens and an imbalance of camera pose, and emissivity calibration which considers viewing angles to the model surface, were employed. Throughout the study, for the quantitative as well as qualitative surface temperature measurement, it was verified that the distortion correction must be considered even for the use of two-dimensional model in aerodynamics testing.
Keywords
Infrared Thermography; Emissivity; Supersonic; Calibration;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Sant, Y. L., Marchand, M., Millan, P., and Fontaine, J., "An Overview of Infrared Thermography Techniques Used in Large Wind Tunnels," Aerospace Science and Technology, Vol. 6, 2002, pp. 355-366.   DOI
2 Cardone, G., Ianiro, A., Ioio, G. D., and Passaro, A., "Temperature Maps Measurements on 3D Surfaces with Infrared Thermography," Experiments in Fluids, Vol. 52, 2012, pp. 375-385.   DOI
3 Henkels, A., and Maurer, F., "Application of Infra-Red Thermography in a Hypersonic Blowdown Wind Tunnel," Institute of Electrical and Electronics Engineers, 1989, CH276-3, pp. 516-524.
4 Schrijer, F. F. J., "Experimental Investigation of Re-Entry Aerodynamic Phenomena," Ph.D Thesis, Delft University of Technology, 2010.
5 Heikkila, J., "Geometric Camera Calibration Using Circular Control Points," Institute of Electrical and Electronics Engineers, Vol. 22, No. 10, 2000.
6 Ochs, M., Horbach, T., Schulz, A., Koch, R., and Bauer, H. J., "A Novel Calibration Method for an Infrared Thermography System Applied to Heat Transfer Experiments," Measurement Science and Technology, Vol. 20, 2009, 075103   DOI
7 Zhang, Z., "A Flexible New Technique for Camera Calibration," IEEE Transactions on Pattern Analysis and Machine Intelligence, Vol. 22, No. 11, 2000, pp. 1330-1334.   DOI
8 Schmidt, E., and Eckert, E., "Uber die Richtungsverteilung der Warmestrahlung von Oberflachen," Forschung im Ingenieurwesen Vol. 6, No. 4, 1935, pp. 175-183.   DOI