Uncertainty in the Calibration of Coaxal Thermal Noise Sources using a Noise Figure Measuring Equipment

  • Kang, Tae-Weon;Kim, Jeong-Hwan;Park, Jeong-Il
    • Journal of electromagnetic engineering and science
    • /
    • 제4권2호
    • /
    • pp.79-86
    • /
    • 2004
  • In this paper, the uncertainty in the calibration of coaxial thermal noise sources using a noise figure measuring (NFM) equipment is evaluated. Contributions to the uncertainty such as the calibration uncertainty of the standard noise source, mismatch, measurement of adapter efficiency, ambient temperature variation, and repeatability are evaluated in the frequency range of 10 MHz to 18 ㎓. Results show that the expanded uncertainty(k=2) is 0.23 ㏈ for the noise sources of 5 ㏈ and 15 ㏈ ENR, and 0.27 ㏈ for those of 21 ㏈.

CALIBRATION OF PHYSICAL QUANTITIES IN DDO PHOTOMETRIC SYSTEM

  • Sung, Hwan-Kyung;Lee, See-Woo
    • 천문학회지
    • /
    • 제20권2호
    • /
    • pp.63-94
    • /
    • 1987
  • Using many homogeneous data of DDO and UBV colors for all luminosity classes and physical quantities known from spectroscopic observations, new calibration schemes with DDO photometric parameters are presented for metal abundance, effective temperature and surface gravity of stars. And an intrinsic color relation is derived for the reddening estimate.

  • PDF

헬륨을 이용한 열유속센서 검정방법의 실험적 연구 (An Experimental Study on Calibration Method of Heat Flux Sensor by using Helium Gas)

  • 양훈철;송철화;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1219-1224
    • /
    • 2004
  • The objective of this study is to propose an experimental calibration facility in which a heat flux sensor can be calibrated under conductive condition by using helium gas. The heat flux calibration facility was designed, simulated and manufactured for use in a high heat transfer condition. It delivers heat fluxes up to a maximum of 35 KW $m^{-2}$. A copper block heated electrically with 3.5 KW power is designed to produce uniform temperature up to 600 K across its face. High heat fluxes are provided between hot plate and cold plate by 1 mm height helium filled gap. A cold plate is maintained around 300 K through pool boiling using a refrigerant and water-cooled heat exchanger. A simulation was conducted to verify the design of the main test section. To verify the performance of calibration facility, a heat flux sensor was examined. The measured heat fluxes were compared to the calculated one.

  • PDF

ABSOLUTE RADIOMETRIC CALIBRATION OF 1M SATELLITE IMAGERY

  • Lee Sun-Gu;Lee Dong-han;Seo Doo-chun;Song Jeong Heon;Kim Yongseung;Paik Hongyul
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.616-619
    • /
    • 2005
  • CALNAL team of Korea Aerospace Research Institute(KARI) performed field campaigns for absolute radiometric calibration of 1m satellite image on Daejeon and the cal/val site of Goheung. The satellite image have spatial resolution of 1m in panchromatic spectral band of 450-900nm. The performed cal/val method is the reflectance-based of vicarious calibration methods. We collected ground-based and meteology data such as temperature, surface pressure and reflectance of targets, and radiosonde data used only to test in Goheung. Data collected on each field served as input to radiative transfer codes to generate a top-of-atmosphere(TOA) radiance estimate. Derived TOA is compared with DN of overpass satellite to calculate calibration coefficient of gain and offset.

  • PDF

CIO capacitance가 작은 analog ZQ calibration 의 설계 (A design of analog ZQ calibration with small CIO capacitance)

  • 박경수;최재웅;채명준;김지웅;곽계달
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.577-578
    • /
    • 2008
  • This paper proposes new analog ZQ calibration scheme. Proposed analog ZQ calibration scheme is for minimizing the reflection which degrade the signal integrity. And this scheme is for minimizing CIO capacitance. It is simulated under 1.5v supply voltage and samsung 0.18um process. Power consumption of proposed analog ZQ calibration circuit was improved by 32%. Under all skew, temperature from $30^{\circ}C$ to $90^{\circ}C$ and Monte carlo simulation, quantization error of RZQ(=$240{\Omega}$) is less han 1.07%.

  • PDF

동력식 조립공구의 측정불확도 산출방법 개발 (Calibration Methods for Measurement Uncertainty of Power Assembly Tools)

  • 오세헌;강기영;홍민성
    • 한국생산제조학회지
    • /
    • 제24권5호
    • /
    • pp.496-501
    • /
    • 2015
  • In this study, calibration procedure of power assembly tools is suggested and methods are developed for calculating measurement uncertainty. Fist of all, the calibration of joint simulator bench (JSB) was carried out for maintaining traceability and the uncertainty components of JSB were analyzed. The influences of tool speed, tolerance, temperature and length of the adapter were examined by the torque measurement values through experiments. From this research, credibility for calibration results could be enhanced. This experimental results, being used as an effective tool for calibration of power assembly tools, will provide and improve the accuracy of the use of the power assembly tools.

밀리미터파 라디오미터를 이용한 인체의 내부 밝기온도 측정에 관한 연구 (Study on the Brightness Temperature Measurement in the Human Body Using Millimeter-wave Radiometer)

  • 정민규;김태훈;나승욱
    • 전자공학회논문지
    • /
    • 제53권5호
    • /
    • pp.163-167
    • /
    • 2016
  • 본 논문은 밀리미터파 라디오미터를 이용한 의료응용의 한 분야인 인체 내부의 밝기온도 측정에 관한 연구이다. 밀리미터파 대역 중에서 Ka - band의 주파수 영역에서 동작하는 렌즈, 직접 검출 수신기, 캘리브레이션 소스 등을 설계 제작하여 라디오미터 시스템을 구성하였다. 밀리미터파 렌즈 초점에 수신안테나를 스캔하는 방식을 통하여 미약한 신호를 수신하였으며, 렌즈 수차를 감소시키기 위해 광선 추적 방법을 사용하여 비구면 렌즈를 설계 하였다. 직접 검출 수신기는 Dicke 타입 수신기 형태로 설계되었으며, 제작된 수신기의 잡음지수는 3.3 dB, 온도감도는 0.1 K으로 측정되었다. 라디오미터의 수신기 교정은 밀리미터파 대역에서 사용가능한 새로운 형태의 블랙바디(Black body)를 제작하여 물체의 등가 잡음온도와 출력전압의 관계를 도출하였다. 제작된 시스템을 이용하여 1.7 m 거리에서 인체의 상반신을 측정하여 약 $38^{\circ}$[C]의 밝기온도를 측정하였다. 적외선 영상과 라디오미터 영상의 비교를 통해 상반신의 밝기온도 영상을 통하여 밀리미터파 라디오미터의 의료응용 가능성을 제시하였다.

원격자료수신장비 소형반사판 안테나 G/T 예측 및 측정 (The calculation and Measurement Methods for G/T of the Telemetry Small Aperture Antenna)

  • 김춘원;안나균;김동현;조병록
    • 한국항공우주학회지
    • /
    • 제50권9호
    • /
    • pp.657-662
    • /
    • 2022
  • 본 논문에서는 나로우주센터에서 운용 중인 원격자료수신장비의 G/T에 대한 시뮬레이션 활용 계산 결과와 측정 방법 2개에 대하여 분석하였다. 안테나 이득과 잡음 온도는 ICARA와 Antenna Noise Temperature Calculator를 이용하여 계산하였다. 시스템 G/T는 안테나 이득/잡음돈도와 LNA 이득/잡음온도, 케이블 손실을 반영하여 산출하였다. 첫 번째 G/T 측정 방법은 Y팩터 측정법으로 LNA 입력단에 안테나와 50ohm 터미네이션을 각각 연결했을 때의 신호 레벨 차이값을 LNA 열잡음 온도와 비교하여 G/T를 산출하는 방법이다. 두 번째 방법은 태양과 최저 레벨 지점을 바라보았을 때의 잡음 레벨 값 차이를 비교하여 G/T를 구하는 Solar Calibration 측정법이다. 마지막으로 G/T 계산결과와 두 측정법 비교를 통해 정확성을 검토하고 이로부터 안테나 성능, 운용환경에 따른 최적 측정법을 제시하였다.

A 12-bit Hybrid Digital Pulse Width Modulator

  • Lu, Jing;Lee, Ho Joon;Kim, Yong-Bin;Kim, Kyung Ki
    • 한국산업정보학회논문지
    • /
    • 제20권1호
    • /
    • pp.1-7
    • /
    • 2015
  • In this paper, a 12-bit high resolution, power and area efficiency hybrid digital pulse width modulator (DPWM) with process and temperature (PT) calibration has been proposed for digital controlled DC-DC converters. The hybrid structure of DPWM combines a 6-bit differential tapped delay line ring-mux digital-to-time converter (DTC) schema and a 6-bit counter-comparator DTC schema, resulting in a power and area saving solution. Furthermore, since the 6-bit differential delay line ring oscillator serves as the clock to the high 6-bit counter-comparator DTC, a high frequency clock is eliminated, and the power is significantly saved. In order to have a simple delay cell and flexible delay time controllability, a voltage controlled inverter is adopted to build the deferential delay cell, which allows fine-tuning of the delay time. The PT calibration circuit is composed of process and temperature monitors, two 2-bit flash ADCs and a lookup table. The monitor circuits sense the PT (Process and Temperature) variations, and the flash ADC converts the data into a digital code. The complete circuits design has been verified under different corners of CMOS 0.18um process technology node.

액체 질소의 흐름 조절을 통한 저온 정밀 온도 제어 (Precise Temperature Control by Adjusting Flow of Liquid Nitrogen)

  • 양인석;이지호
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.65-70
    • /
    • 2016
  • We devised a method to control the temperature of a liquid bath as low as $-100^{\circ}C$ using the duty cycle control of a solenoid valve. The solenoid valve controls the flow of liquid nitrogen that we used as a cryogen in this system. By controlling the duty cycle of a solenoid valve using feedback from the measured temperature of the liquid bath, we were able to achieve temperature stability within ${\pm}19mK$ around $-100^{\circ}C$. We also demonstrated that by taking average values of the temperature readings for sequence of measurements from more than one thermometer, it is possible to use this system for the calibration of thermometers within 3 mK. This system and the control method can be used for the precise temperature control in the range between $0^{\circ}C$ and $-100^{\circ}C$, where commercially available precision baths are much expensive and hard to be built in customized configurations.