• 제목/요약/키워드: Temperature Trend

검색결과 1,284건 처리시간 0.039초

전기발열시트 표면가열 양생공법의 현장적용 연구 (An Experimental Study on the Application in-situ of Curing Method by Planar Surface Heater for Cold Weather Concreting)

  • 김형래;조호규;김찬수;지남용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.19-22
    • /
    • 2003
  • The purpose of this study is to analyze the curing effect of planar surface heater for concreting in cold weather. Some experiments were conducted to evaluate the temperature history of concrete structures cured with heating sheets. Results are as follows ; (1) The temperature of concrete showed continuously rising trend with the heating by planar surface heater under the cold environmental condition of 3~-12$^{\circ}C$. And after about 24 hours the maximum temperature of concrete was reached at 25~3$0^{\circ}C$. (2) The temperature of slab concrete heated by planar surface heater of 130W/$m^2$ was at least $25^{\circ}C$ higher than that of an exterior air, and the curing performance was much more effective than heating by hot wind machine. (3) Through the curing by planar surface heater for 48 hours, the concrete maturity of about 1.5 times to heating by hot wind machine was acquired.

  • PDF

NUMERICAL INVESTIGATION OF THE SPREADING AND HEAT TRANSFER CHARACTERISTICS OF EX-VESSEL CORE MELT

  • Ye, In-Soo;Kim, Jeongeun Alice;Ryu, Changkook;Ha, Kwang Soon;Kim, Hwan Yeol;Song, Jinho
    • Nuclear Engineering and Technology
    • /
    • 제45권1호
    • /
    • pp.21-28
    • /
    • 2013
  • The flow and heat transfer characteristics of the ex-vessel core melt (corium) were investigated using a commercial CFD code along with the experimental data on the spreading of corium available in the literature (VULCANO VE-U7 test). In the numerical simulation of the unsteady two-phase flow, the volume-of-fluid model was applied for the spreading and interfacial surface formation of corium with the surrounding air. The effects of the key parameters were evaluated for the corium spreading, including the radiation, decay heat, temperature-dependent viscosity and initial temperature of corium. The results showed a reasonable trend of corium progression influenced by the changes in the radiation, decay heat, temperature-dependent viscosity and initial temperature of corium. The modeling of the viscosity appropriate for corium and the radiative heat transfer was critical, since the front progression and temperature profiles were strongly dependent on the models. Further development is required for the code to consider the formation of crust on the surfaces of corium and the interaction with the substrate.

Structural and Magnetic Properties of LaFeO3-BaTiO3 Solid Solutions

  • Ramana, E.Venkata;Kwon, O-Ung;Kim, Jin-I;Jung, C.U.
    • Journal of Magnetics
    • /
    • 제14권3호
    • /
    • pp.117-119
    • /
    • 2009
  • Polycrystalline samples of LaFe$O_3$-BaTi$O_3$ were synthesized to examine the structural and magnetic behavior. X-ray diffraction confirmed that the ceramics had tetragonal symmetry with less tetragonal strain (c/a) than BaTi$O_3$. The magnetic hysteresis measured at room temperature suggested that the magnetic nature deviates from that of the parent LaFe$O_3$, which has antiferromagentic with a G-type spin structure. Improved magnetic behavior of the solid solution compound might be due to the increase in the canting angle of the spin. The presence of oxygen vacancies and fluctuating Fe valence, arising from the substitution of $Ba^{2+}$ and $Ti^{4+}$ at the A- and B-sites of the lattice, might contribute to bulk magnetization. The temperature dependent magnetization indicated that magnetization was higher at low temperatures and showed a decreasing trend with increasing temperature to room temperature. The magnetic transition temperature of these samples was 665 K and 743 K for the mixed system and LaFe$O_3$, respectively.

실물대시험에서의 양생방법 차이에 따른 한중콘크리트의 온도이력 및 강도특성에 관한 연구 (A Study on the Strength Properties and the Temperature Hysteresis of Winter Concrete according to the difference of Curing Method in Mock-up Test)

  • 원철;한천구
    • 한국건축시공학회지
    • /
    • 제3권4호
    • /
    • pp.87-94
    • /
    • 2003
  • This study is to investigate the temperature hysteresis and development of compressive strength due to the curing conditions and to evaluate the optimum curing condition of test specimens showing the same development of strength to that of real structures in cold weather. The results of temperature curve with curing conditions in mock-up tests showed the trend of decrease plain concrete with insulation form, plain concrete with heating, concrete with accelerator for freeze protection, and control concrete in turn. The strength development of plain concrete of inside and outside of shelter showed the very slow strength gains due to early freezing, but that of concrete with accelerator for freeze protection showed the gradual increase of strength with time. From this, it is clear that accelerator for freeze protection has the effects of refusing the freezing temperature and accelerating the hardening under low temperature. Strength test results of small specimens embedded in members and located in insulation boxes at the site are similar to that of cores drilled from the members at the same ages, thus it is clear that these curing methods are effective for evaluating in-place concrete strength

Development and verification of PWR core transient coupling calculation software

  • Li, Zhigang;An, Ping;Zhao, Wenbo;Liu, Wei;He, Tao;Lu, Wei;Li, Qing
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3653-3664
    • /
    • 2021
  • In PWR three-dimensional transient coupling calculation software CORCA-K, the nodal Green's function method and diagonal implicit Runge Kutta method are used to solve the spatiotemporal neutron dynamic diffusion equation, and the single-phase closed channel model and one-dimensional cylindrical heat conduction transient model are used to calculate the coolant temperature and fuel temperature. The LMW, NEACRP and PWR MOX/UO2 benchmarks and FangJiaShan (FJS) nuclear power plant (NPP) transient control rod move cases are used to verify the CORCA-K. The effects of burnup, fuel effective temperature and ejection rate on the control rod ejection process of PWR are analyzed. The conclusions are as follows: (1) core relative power and fuel Doppler temperature are in good agreement with the results of benchmark and ADPRES, and the deviation between with the reference results is within 3.0% in LMW and NEACRP benchmarks; 2) the variation trend of FJS NPP core transient parameters is consistent with the results of SMART and ADPRES. And the core relative power is in better agreement with the SMART when weighting coefficient is 0.7. Compared with SMART, the maximum deviation is -5.08% in the rod ejection condition and while -5.09% in the control rod complex movement condition.

가공 온도가 다른 STS316L의 탄성파 특성 (Elastic Wave Properties of STS316L with Different Rolling Temperature)

  • 탁영준;구경희;이금화;남기우
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.325-331
    • /
    • 2022
  • In this study, austenitic 316L stainless steel was rolled at three different temperatures (100℃, -50℃, -196℃) at five rolling degree (0, 16, 33, 50, 66 and 80%). The rolled specimen was examined for micro structure, and the volume fraction and mechanical properties were evaluated. In particular, the rolling specimen detected the elastic wave generated in tensile and investigated the relationship between the rolling degree and the dominant frequency. As the rolling degree increased, austenite decreased and martensite increased. The volume fraction of martensite more increased at lower temperatures, but increased rapidly at the rolling degree of 50% of all rolling temperature. Tensile strength increased rapidly with the increase of the rolling degree, and was larger at lower temperatures. The elongation decreased sharply to the rolling degree of 33%, but decreased gently thereafter. The dominant frequency highly appeared as the volume fraction of martensite increased, but the dominant frequency was higher at the low temperature rolling temperature. A similar trend was also observed in the relationship between tensile strength and dominant frequency.

Density Profile and Sound Absorption Capability of Ceramics Manufactured from Sawdust, Chaff and Charcoal: Effect of Carbonization Temperature and Mixing Ratio

  • Jung-Woo HWANG;Seung-Won OH
    • Journal of the Korean Wood Science and Technology
    • /
    • 제52권3호
    • /
    • pp.234-242
    • /
    • 2024
  • In this study, the effect of carbonization temperature and mixing ratio of ceramics manufactured from sawdust, chaff and charcoal on sound absorption performance and density profile was investigated. The density profile of ceramics prepared by the addition rates of sawdust, chaff and charcoal showed the highest value at 91.00% when the ratio of sawdust, chaff and charcoal was 50:25:15. However, the difference in density profile according to the addition rate was insignificant. The density profile of ceramics manufactured according to the carbonization temperature showed the highest value of 88.06% when manufactured at 800℃. However, it does not show any particular trend, so it is understood that the effect of the carbonization temperature on the density gradient is small. On the other hand, the sound absorption coefficients of ceramics prepared by the addition rates of sawdust, chaff and charcoal is between 0.3 and 0.4 at almost all frequencies when the addition rates of sawdust, chaff and charcoal are 50:30:10 and 50:35:5, respectively. Therefore, as the chaff particles increased, the sound absorption performance was improved. In addition, the sound absorption coefficients of the ceramics manufactured at each carbonization temperature showed the highest value in the ceramics manufactured at 1,200℃.

기상정보를 활용한 의류제품 판매예측 시스템 연구: S/S 시즌 제품을 중심으로 (A Study on Clothes Sales Forecast System using Weather Information: Focused on S/S Clothes)

  • 오재호;오희선;최경민
    • 한국의류산업학회지
    • /
    • 제19권3호
    • /
    • pp.289-295
    • /
    • 2017
  • This study aims to develop clothing sales forecast system using weather information. As the annual temperature variation affects changes in daily sales of seasonal clothes, sales period can be predicted growth, peak and decline period by changes of temperature. From this perspective, we analyzed the correlation between temperature and sales. Moving average method was applied in order to indicate long-term trend of temperature and sales changes. 7-day moving average temperature at the start/end points of the growth, peak, and decline period of S/S clothing sales was calculated as a reference temperature for sales forecast. According to the 2013 data analysis results, when 7-day moving average temperature value becomes $4^{\circ}C$ or higher, the growth period of S/S clothing sales starts. The peak period of S/S clothing sales starts at $17^{\circ}C$, up to the highest temperature. When temperature drops below $21^{\circ}C$ after the peak temperature, the decline period of S/S clothing sales is over. The reference temperature was applied to 2014 temperature data to forecast sales period. Through comparing the forecasted sales periods with the actual sales data, validity of the sales forecast system has been verified. Finally this study proposes 'clothing sales forecast system using weather information' as the method of clothing sales forecast.

Change in plasma cortisol and glucose levels of Oncorhynchus keta according to water temperature

  • Young Seok Seo;Hyo Bin Lee;Joo Hak Jeong;Seong Jun Mun;Han Kyu Lim
    • Fisheries and Aquatic Sciences
    • /
    • 제26권2호
    • /
    • pp.117-132
    • /
    • 2023
  • Chum salmon (Oncorhynchus keta) is a species of anadromous salmonid inhabiting coastal rivers in the North Pacific and the Arctic in the Bering and is the most widely distributed among Pacific salmon species. It is an important fish species in Korea as the salmon releasing project is being actively carried out. This study was conducted to investigate changes in the physiological activity of O. keta according to water temperature. Three experiments were conducted according to the water temperature and period, and the plasma concentrations of cortisol and glucose were analyzed from the blood samples of the experimental groups. Experiment I is a short-term water temperature experiment, in which water temperature stimulation was given for 4 hours at water temperatures of 12℃, 16℃ (control), 20℃, and 24℃, and a recovery period was given for 4 hours. Experiment II is an experiment in which water temperature stimulation was given for 24 hours, 48 hours, and 72 hours at a high temperature of 24℃, and a recovery period was given for 12 hours, respectively. Experiment III is a long-term water temperature experiment, in which the water temperature was 12℃, 16℃ (control), 20℃, and 24℃ for 8 weeks. As a result of the experiment, in Experiment I, there was no significant difference in the survival rate between the experimental groups, but the concentration of cortisol and glucose in the plasma according to the set water temperature showed a significant difference. In Experiment II, there was no significant trend according to the maintenance time of the high-temperature state, but as the temperature increased, the plasma cortisol and glucose levels significantly increased compared to the control group. In Experiment III, all of the experimental group C (24℃) died in the 1st week, and there was no significant difference in the plasma glucose at the 1st and 8th weeks among the remaining experimental groups.

인공위성 관측 자료를 이용한 해양-대기 DMS flux 추정 및 장기 추세 분석 (Estimations and Long-term Trend of Sea-to-air Dimethyl Sulfide (DMS) Flux using Satellite Observation Data)

  • 최유나;송상근;한승범;손영백;박연희
    • Ocean and Polar Research
    • /
    • 제39권3호
    • /
    • pp.181-194
    • /
    • 2017
  • The long-term linear trend of global sea-to-air dimethyl sulfide (DMS) flux was analyzed over a 16-year time span (2000~2015), based on satellite observation data. The emission rates of DMS (i.e. DMS flux) in the global ocean were estimated from sea surface DMS concentrations, which were constructed with chlorophyll a (Chl-a) concentrations and mixed layer depths (MLD), and transfer velocity from sea to air, which was parameterized with sea surface wind (SSW) and sea surface temperature (SST). In general, the DMS flux in the global ocean exhibited a gradual decreasing pattern from 2000 (a total of 12.1 Tg/yr) to 2015 (10.7 Tg/yr). For the latitude band ($10^{\circ}$ interval between $0^{\circ}$ and $60^{\circ}$), the DMS flux at the low latitude of the Northern (NH) and Southern hemisphere (SH) was significantly higher than that at the middle latitude. The seasonal mean DMS flux was highest in winter followed by in summer in both hemispheres. From the long-term analysis with the Mann-Kendall (MK) statistical test, a clear downward trend of DMS flux was predicted to be broad over the global ocean during the study period (NH: $-0.001{\sim}-0.036{\mu}mol/m^2/day\;per\;year$, SH: $-0.011{\sim}-0.051{\mu}mol/m^2/day\;per\;year$). These trend values were statistically significant (p < 0.05) for most of the latitude bands. The magnitude of the downward trend of DMS flux at the low latitude in the NH was somewhat higher than that at the middle latitude during most seasons, and vice versa for the SH. The spatio-temporal characteristics of DMS flux and its long-term trend were likely to be primarily affected not only by the SSW (high positive correlation of r = 0.687) but also in part by the SST (r = 0.685).