• 제목/요약/키워드: Temperature Difference Measurement

검색결과 446건 처리시간 0.031초

난방시 가압식 바닥취출 공조방식의 실내온열환경 평가 (An Estimation on Indoor Thermal Environment by Pressurized Plenum Under Floor Air Conditioning System in Heating)

  • 최은훈;이용호;권영철;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.92-99
    • /
    • 2010
  • The purpose of this study is to apply pressurized plenum under floor air conditioning system to office areas to understand characteristics of indoor thermal environment based on forms of diffusers. For doing this, the author conducted experiment of module measurement, and based on the results, analyzed indoor temperature distribution and velocity distribution based on direction of diffusion by using Computational Fluid Dynamics(CFD), and estimated the Predicted Mean Vote(PMV) of residents based on forms of diffusers to present the optimal air conditioning of the pressurized plenum under floor air conditioning system in heating. The results of this study are as follows. First, as for forms of diffusers, distributed diffusers rather than conical and grill diffusers were favorable in maintaining $24^{\circ}C$, the established temperature in heating, were active in velocity flowing, and were wide in a radius of diffusion. Second, as for position of pressurizing, the difference between upper and lower temperature was wider in center, lateral, and dispersed pressurizing (in order). As for velocity distribution, the velocity was more increased in lateral, center, and dispersed pressurizing(in order), indicating that dispersed pressurizing maintained uniform thermal environment. Third, as for diffusion direction, mixed direction showed less difference between upper and lower temperature and the difference in velocity between center and lateral part was 0.01m/1, indicating that it maintained uniform thermal environment. Fourth, as for the PMV of residents based on the forms of diffusers, the dispersed type showed(+) values above (0) when applied variably based on the position of diffuser, presenting thermal feeling of "being comfortable" to residents.

92 GHz Radiometer System for Remote Sensing Applications

  • Kim, Yong-Hoon;Kim, Sung-Hyun;Kang, Gum-Sil;Kim, Han-Sik;Yang, Ki-Seok
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.462-467
    • /
    • 1999
  • In this paper, very high performance millimeter-wave radiometer of 92 GHz is presented. Radiometer system design, brightness temperature measurement and calibration methods are described. The architecture of radiometer including data acquisition, storage and digital signal processing using a notebook computer are explained and some experimental data in the laboratory are introduced. The system noise figure and total gain of implemented radiometer are 12 dB and 56 dB, respectively. The system stability is evaluated from the experiment. The difference of the detector output voltage for two targets, whose brightness temperature are 80 K and 300K, is 4 mV. The mechanical scanning method is considered to get a brightness temperature Image of the earth surface scene.

  • PDF

대구 도심에 위치한 대규모 녹지공간의 냉섬 강도: 계절변화와 기상조건에의 관련성 (Cool Island Intensity in a Large Urban Green in Downtown Daegu: Seasonal Variation and Relationship to Atmospheric Condition)

  • 박명희;김해동
    • 한국환경과학회지
    • /
    • 제19권1호
    • /
    • pp.81-87
    • /
    • 2010
  • Cool island intensity urban green space was investigated based in Dalsung Park, that is one of the largest parks in Daegu. Cool island intensity(CII), which is defined as the temperature difference between the green space and its surrounding built-up areas, shows time variations. A through-year measurement(2008-2009) of ground level air temperature revealed seasonal variation and relationship to the atmospheric condition of CII. The temperature variation in the park and the reference downtown Daegu was as same order as CII. The noontime CII is larger in summer than that in winter due to the leaf fall of the park trees. On the other hand, seasonal variation of nighttime CII is not so clear. The nighttime CII was larger under the stable atmosphere.

열영동력이 수평 웨이퍼상의 입자침착에 미치는 영향 (Thermophoretic Effect on Particle Deposition Toward a Horizontal Wafer)

  • 배귀남;박승오;이춘식
    • 대한기계학회논문집
    • /
    • 제18권1호
    • /
    • pp.175-183
    • /
    • 1994
  • To investigate thermophoretic effect on particle deposition, average deposition velocity toward a horizontal wafer surface in vertical airflow is measured keeping the wafer surface temperature different from the surrounding air temperature. In the present measurement, the temperature difference is maintained in the range from -10 to $4^{\circ}$ C Polystyrene latex (PSL) spheres of diameter between 0.3 and 0.8 .mu.m are used for the experiment. The number of particles deposited on a wafer surface is estimated from the measurements using a wafer surface scanner (PMS SAS-3600). Experimental data are compared with prediction model results.

A Study on the Thermal Analysis of Circular LED Street Lights

  • So, Byung Moon
    • 반도체디스플레이기술학회지
    • /
    • 제16권3호
    • /
    • pp.99-105
    • /
    • 2017
  • This paper confirms the similarity of temperature tendency through numerical analysis and comparison with test, and it also confirms that temperature prediction of LED lightings is possible by numerical analysis. We confirmed that the temperature difference is about $10{\sim}20^{\circ}C$ except for some measurement points and shows similar tendency with the interpretation through manufacturing and performance analysis of AL heat sink applied Circular LED street lights and manufacturing and performance analysis of CMP-PLA heat sink applied Circular LED street lights. The simulations use Octree technique in SC/Tetra to set the grid size df the surface.

  • PDF

군용 열영상장비 최소분해가능온도차의 정량적 측정 방법 및 탐지거리 예측에 관한 연구 (A Study on the quantitative measurement methods of MRTD and prediction of detection distance for Infrared surveillance equipments in military)

  • 정영탁;임재성;이지혁
    • 한국산학기술학회논문지
    • /
    • 제18권5호
    • /
    • pp.557-564
    • /
    • 2017
  • 대한민국 군의 K 계열 전차에 장착되어 있는 열영상장비의 목적은 시계가 제한된 환경에서 외부의 적외선 영역의 정보를 인간이 인지할 수 있는 시각 정보로 변환하는 것이다. 열영상장비의 시계, 배율, 분해능, 변조전달함수, 잡음등가온도차, 최소분해가능온도차 등의 지표 중에서 최소 분해 가능 온도차(MRTD)는 공간주파수와 온도분해능을 복합적으로 표현할 수 있기 때문에, 열영상장비의 성능 표현에 있어 가장 중요한 파라메터이다. 그러나 NATO의 MRTD 표준 측정 방법은 많은 주관적인 요소를 포함하고 있다. 즉, 측정자의 정신 상태, 시력 등의 차이와 측정환경에 따라 측정 결과의 오차가 발생하므로 MRTD의 측정결과는 안정적이지 못하다. 따라서 본 논문에서는 정성적인 MRTD 측정 방법을 gary scale을 바탕으로 이미지 연산을 통한 정량적인 지표로 변환하였다. 흑상과 백상의 Gray scale 차이의 평균을 최소분해가능온도로 변환하여, 국방규격서에서 요구하는 성능요구조건의 충족여부를 판단할 수 있다. 또한 gray scale은 MRTD의 탐지/인지/식별의 판별기준으로 활용할 수 있다. 전차에 열영상장비가 탑재되어 작전을 수행할 때의 탐지 가능 거리를 안개, 폭우, 맑은 날씨 등의 다양한 환경조건에 따라 분석하였다.

Micro-computer를 이용(利用)한 Greenhouse의 온도제어(溫度制御) System 개발(開發)에 관한 연구(硏究) (A Study on the Development of Greenhouse Temperature Control System by Using Micro-computer)

  • 서원명;민영봉;윤용철
    • Journal of Biosystems Engineering
    • /
    • 제15권2호
    • /
    • pp.134-142
    • /
    • 1990
  • This study was carried out for the development of greenhouse temperature control system by modifying an APPLE-II microcomputer attached with several interface systems. The interface systems are composed of 12 bit A/D converter, output port, multiplexer, time clock, etc. Under the operation of developed system, the greenhouse temperature was to be manipulated within the setting temperatures assumed to be appropriate for certain plant growth. The temperature control equimpents installed in the greenhouse are one-speed propeller type fan and two-phase electric heater, which are selectively started or stopped according to the control logic programmed in the control system. The results are summarized as follows : 1. The difference between two temperatures measured by the developed system and the self-recording thermometer calibrated with standard thermometer was less than $1^{\circ}C$. 2. When the temperature were measurd by 12 bit A/D converter and both electric heater and ventilation fan were controlled by developed ON/OFF logic, greenhouse temperature showed narrow fluctuation bands of less than $1^{\circ}C$ near the setting temperatures. 3. The temperature acquisition and control system developed in this study is expected to be applicable to environment control system such as greenhouse only by modifying the logic based on long term experimental data. 4. In order to reduce the measurement error and to increase the system control efficiency, it is recommended that continuous study should be carried out in the aspect of eliminating various systematic noises and improving the environmental control logic.

  • PDF

변형 2색법에 의한 예혼합기 연소의 연소가스온도 측정에 관한 연구 (A Study on the Measurement of Burnet Gas Temperature in Premized Combustion by Modified Two-Color Method)

  • 배명환
    • 한국자동차공학회논문집
    • /
    • 제7권8호
    • /
    • pp.43-54
    • /
    • 1999
  • The effects of equivalence ratio and pressure on burnt gas temperature in premixed fuel rich propane-oxygen-inert gas combustion are investigated over the wide ranges of equivalence ration from 1.5 to 2.7 and pressure from 0.1 to 7 MPa by using a specially designed disk -type constant-voume combustion chamber, The premixtures are simultaneously ignited by eight spark plugs located on the circumference of combustion chamber with 45 degree interals. The eight converging flames compress the end gases to high pressures. The burnt gas temperature is meausured by the nmodifie dtow-colr pyrometry method. The transmissivity in the chamber center during the final stage of combustion at the hightest pressure is meausred by in situ laser extinction method. It is found that a temperature difference between the burnt gas temperature measured by mofidied and conventrational two-color method is 10 to 20 K, but the accuracy of the modified two-color methdo is higher if the local transmissivity in observed region is uniform , and the combustion at higher pressures results gas density conditions and the burnt gas temperature increases as the volume fraction of argon is increased because the specific heat of argon is lower compared to that of nitrogen with a constant equivalence ratio.

  • PDF

실내 환경의 공간 색온도 검출을 위한 이미지센서 모듈 (Image Sensor Module for Detecting Spatial Color Temperature in Indoor Environment)

  • 문성재;김영우;임영석
    • 한국전자통신학회논문지
    • /
    • 제16권1호
    • /
    • pp.191-196
    • /
    • 2021
  • 본 논문에서는 실내 환경에서 색온도 검출이 가능한 이미지센서 모듈을 구현하였다. 이미지센서로 획득한 영상정보 내 색온도 정보는 색차조도계와 정합하여 LUT(Look Up Table)로 제작하였으며, 수광된 RGB값에 따른 색온도 정보가 자동 산출이 가능하도록 알고리즘을 개발하여 MCU(Micro Control Unit)에 반영하였다. 실내에서 이미지센서로 색온도를 측정한 결과 기준값 대비 5.91% 이하의 정확한 결과를 얻을 수 있었으며, 컬러센서를 이용한 색온도 측정 결과 대비 23.5% 이상의 균일도가 우수함을 확인하였다.