지역난방의 일반제어 및 열량제어 에너지 시뮬레이션 (Energy Simulation for Conventional and Thermal-Load Controls in District Heating)

  • 이성욱;홍희기;조성환
    • 설비공학논문집
    • /
    • 제27권1호
    • /
    • pp.50-56
    • /
    • 2015
  • Korea district heating systems have mainly used setting temperature control and outdoor reset control. Different from such conventional normal methods, a thermal-load control proposed in Sweden can decrease the return temperature and reduce pump power consumptions because the control is able to provide the appropriate amount of required heat. In this study, further improved predictive optimal control in addition to the conventional controls were simulated in order to verify its effect in district heating system using TRNSYS 17. $200m^2$ apartment housing which accounts for 25% in Korea and is used as a calculation model;. the number of households in the simulation was 9. As a result, a higher temperature difference and decreasing flow rate at primary loop were shown when using thermal-load control.

공랭식 변유량 냉매 냉동기를 적용한 수조 온도의 정밀 제어 (Precision Control of Water Bath Temperature using Air Cooled Variable Refrigerant Flow Chiller)

  • 정광주;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.27-34
    • /
    • 2018
  • This study compared constant water bath performances of conventional water-cooled refrigerator and electric heater with an air-cooled VRF chiller and electric heater equipped with optimal control algorithm. In heating mode, the air cooled VRF chiller and electric heater combination reduced the set temperature arrival time by an average of 42 minutes, and energy was also reduced by 18%. In cooling mode, the two systems took 70 minutes to reach the set temperature and showed no difference. Energy was reduced by 33.5% with the new system. For constant temperature maintaining experiment, after reaching the set temperature of $15^{\circ}C$, $20^{\circ}C$ and $22^{\circ}C$, temperature deviations were all in the range of $-0.2^{\circ}C$ to $+0.1^{\circ}C$. Energy was reduced by an average of 84.9%. Through this study, possibility of precise temperature control by an air cooled VRF chiller system was confirmed.

벼 등숙기 고온이 잎의 엽록소구성과 광합성 및 생리적 변화에 미치는 영향 (Effect of High Temperature on Leaf Physiological Changes as Chlorophyll composition and Photosynthesis Rate of Rice)

  • 손지영;김준환;이충근;양운호
    • 한국작물학회지
    • /
    • 제60권3호
    • /
    • pp.266-272
    • /
    • 2015
  • 등숙기 고온이 잎의 생리적 활력과 등숙에 미치는 영향을 알아보고자, 동안과 일품 두 품종을 등숙기에 고온 처리하여 등숙 형질을 분석하고, 잎의 광합성, 엽록소 함량 및 엽록소 a/b율 등을 알아보았다. 등숙기 고온($27{\pm}4^{\circ}C$)처리에서 두 품종 모두 등숙률, 완전립률, 천립중이 감소하였으나 일품은 동안에 비해 모두 감소율이 컸다. 엽록소 함량은 등숙초기 고온에서 적온보다 두 품종 모두 증가하였으며, 등숙중기이후 엽록소감소양상은 온도처리에 따른 차이가 없었다. 엽록소 a/b율은 고온에서 감소하였다가 출수후 15일 이후 증가하였으며 적온에서는 출수 이후 지속적으로 증가하였다. 잎의 단백질농도 변화는 고온에서 등숙초기 약간 높은 경향이었으나 이후 처리 간 차이없이 등숙후기까지 지속적으로 감소하였다. 최대 광합성량은 유숙기인 출수 후 14일에 고온이 적온보다 높았고 출수후 7일과, 등숙후기(출수후 34일)에는 유의한 차이가 없었다. 잎의 유리당 함량은 고온이 적온보다 낮았다. 결론적으로 등숙기 고온은 잎의 생리적 활력을 적온보다 오히려 증가 시켜 엽록소함량과 광합성율이 증가하였으므로, 고온에 의한 이삭의 등숙저하는 이삭으로의 전류나 전분축적기작 과정의 문제가 더 클 것으로 생각된다.

물주머니를 이용한 가온요법이 고위험신생아의 체온과 산소요구도, 호흡수, 혈당에 미치는 효과 (The Effects of Warm Water-Filled Bag on Body Temperature, $FiO_2$, Respiration Rate, and Blood Sugar in High Risk Neonates)

  • 김희영;박호란;문영임;박진희
    • Child Health Nursing Research
    • /
    • 제11권4호
    • /
    • pp.390-395
    • /
    • 2005
  • Purpose: To investigate the effects of a warm water-filled bag on body temperature, Oxygen demand, respiratory rate and blood sugar in high risk neonates. Method: The infants were assigned to two groups, 16 in the experimental and 20 in the control group. Infants in the experimental group was received $40{\~}42^{\circ}C$ warm water-filled bag therapy for 2 hours under radiant warmers. Infants in the control group were placed under the same kind of radiant warmers but without the warm water-filled bag. The following were measured every 30 minutes: rectal temperature, $O_2$ demand ($FiO_2$), and respiratory rate. Blood sugar was measured hourly. Result: Body temperatures increased significantly in the experimental group (P=0.0138), and there was a difference according to time (P=0.0001). Significant difference were found between the two groups fur $FiO_2$ (P=0.0180). There was no difference in respiratory rates between the two groups and rates according to time for the experimental group were also not significant (P=0.3569). No significant difference between two groups was found for blood sugar (P=0.2152), but there was a significant difference according to the times (P=0.0001). Conclusion: This results of this study indicate that a warm-filled bag is an effective means of resorting body temperature and reducing $O_2$ demand in high risk neonates.

  • PDF

바닥복사 난방시스템의 실내 열환경 특성에 대한 실험적 연구 (Experimental Study on the Indoor Thermal Characteristics for Floor Radiant Heating System)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.1-12
    • /
    • 2021
  • In this study, the effects of various operational conditions for floor radiant heating system were researched by experiments. Hot water supply set temperature, indoor air set temperature and supply water flowrate were considered as operational conditions. The control method for this system is On-Off control of automatic thermostatic valve. The purpose of this study is to evaluate indoor thermal control characteristics and energy performance, respectively. As a result, if lower supply water temperature is applied, the supply and return temperature difference is reduced and energy consumption of heat supply is also reduced.

An automated control system for concrete temperature development in construction

  • Qiang, Sheng;Leng, Xue-jun;Wang, Xiang-rong;Zhang, Jing-tao;Hua, Xia
    • Computers and Concrete
    • /
    • 제24권5호
    • /
    • pp.437-444
    • /
    • 2019
  • PLC and its expansion module, electric ball valve and cooling pipe, electric heating steel plate and various components of the system, which is used to control test and process data. By automatically adjusting the opening of the valve, the system makes the top temperature and cooling speed develop along the ideal temperature diachronic curve. Moreover, the system enables the temperature difference between inside and surface of test block limited in a given range by automatically controlling the surface board heating. The method of physical simulation test by sandbox with built-in cooling water pipe and heating rod is adopted. On the premise of a given standard value, the operation of the system is checked under different working conditions. Further, an extension of this system is proposed, which enables its application to obtain some thermal parameters when cooperating with numerical simulation.

CCTV통신용 함체내의 항온항습 자동제어 장치 개발 (Internal communication as CCTV Automatic Climate Control System Development)

  • 김희철
    • 한국전자통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.433-439
    • /
    • 2015
  • CCTV용 함체 내부는 일정한 습도와 온도를 유지시켜 습윤에 의한 단락방지, 온도차에 의한 결로방지, 고온방지 등의 항온항습장치가 요구되며 이를 대응한 함체에 최적화된 형태와 구조, 에너지활용 정도의 항온항습 자동제어장치개발이 필요하다. 함체내부에 있는 고가의 영상장비를 온도 변환에 따른 해저드로부터 장치보호, 단락사고를 예방할 수 있는 항온항습 제어장치가 필요하다. 이는 영상기록 및 현장상황에 신뢰성 있는 영상의 저장 및 전송을 위한 부속장치가 절대적으로 요구되는 시스템이다.

한지창호의 실내 온.습도 조절효과에 관한 실험적 연구 (An Experimental Study on the Effect of Hanji Windows on Indoor Air Temperature and Humidity Control)

  • 장길수;박사근;송민정;신훈
    • 한국주거학회논문집
    • /
    • 제17권2호
    • /
    • pp.125-134
    • /
    • 2006
  • The tightness of windows have devoted to the improvement of thermal insulation and energy saving in buildings. But it is known that this tightness causes some side effects such as low ventilation, low capacity to humidity and temperature control and these are not profitable for inhabitants. To act on these side effects, Korean traditional windows which are composed of Han-Ji(Koreand traditional paper) and Chang-Sal(Korean traditional wooden frame) have been studied to get a reasonable solutions for these problems. In this study, to compare the thermal and humidity control performance of current window(12 mm pair) and Korean traditional windows, frames which are made of existing window and Korean traditional windows are adapted to scale model house and then humidity and temperature of in and out of scale model house are measured and analysed. The results of this study are followings ; 1) When Korean traditional window charges 20cm(1/8 of total window area) from total window area, Han-Ji window has higher thermal insulation than that of existing window in daytime. There is the most big thermal difference when double faced with double-ply Han-Ji window is placed to mock-up house. In night-time, the temperature difference is very small so this means that Korean traditional window is good to cover direct sunlight in daytime and reduce the temperature of balcony. One faced with one-ply han-Ji window has the best humidity penetration performance among three type of Korean traditional windows. 2) When Korean window area enlarged to 40cm(1/4 of total window area), the function of 40cm width Han-Ji window is higher than that of 20cm's. This means that enlargement of Han-Ji window cover direct sunlight more and is more efficient in humidity penetration.

임상 간호사의 교대근무 기간이 circadian rhythm 변화에 미치는 영향 (Effect of Shift Interval for the Clinical Nurse on the Circadian Rhythm)

  • 황애란;정현숙;임영신;이혜원;김조자
    • 대한간호학회지
    • /
    • 제21권2호
    • /
    • pp.129-149
    • /
    • 1991
  • Circadian rhythm is entrained in the 24-hour time interval by periodic factors in the environment, known as zeitgeber. But most rotating work schedules are outside the range of the entrainment of the pacemaker timing the human circadian sleep - wake cycle. It has been postulated that physiological and emotional disturbances occur in most human functions when the circadian rhythm is disturbed. So application of circadian principles to the design of shift schedules can aid in maintaining the temporal integrity of the circadian system and thereby minimize for the shift worker any detrimental consequences of circadian disruption. This study was a quasi-experimental study to test the effect of shift intervals for the clinical nurse on the circadian rhythm. Twenty nurses newly employed in general units of two hospitals were selected as an experimental group and twelve college nursing students as a control group. Both groups were selected according to an established criteria using a purposive sampling technique. Ten subjects were assigned to a weekly shift group and another ten to a biweekly shift group engaged in a semi -continuous shift schedule(sunday off) with a backward direction, that is, morning -evening - night shift. The control group worked a morning shift for 42 days. Oral temperature rhythm, waking tim, sleep - wake cycle, fatigue, and mental performance were measured during the experimental period. The data collection period was from April 30, 1990 to June 10, 1990. MANOVA, paired t-test, ANOVA, and Student Newman Keuls method were used for statistical analysis. The results are summarized as follows. 1. Phase delay in the acrophase of temperature rhythm was shown according to the backward rotating shift. A complete adaptation to work on the night shift was achieved between the sixth and ninth day of the night shift. 2. There was no difference in either waking time or sleep- wake cycle according to the duration of the working day for every shift group. Significant difference was found in the waking time and the sleep -wake cycle for subjects on the morning, evening, and night shift in both of the shift groups(weekly shift group : λ=0.121, p<0.01, λ=0.112, p<0.01, biweekly shift group : λ=0.116, p<0.01, λ=0.084, p<0.01). 3. There was no difference in fatigue between the first working day and the last working day for the control group and for the biweekly shift group. In the weekly shift group, physical fatigue was significantly different for the first day and the sixth day of the night shift(t=-2.28, p<0.05). Physical fatigue and total fatigue on the first day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=5.79, p<0.01, F=4.56, p<0.05). There was a significant difference between the shift groups and the control group(p<0.05), Physical fatigue, neurosensory fatigue and total fatigue on the last day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=12.65, p<0.01, F=7.77, p<0.01, F=9.68, p<0.01). There was a significant difference between the shift groups and the control group(p<0.05). 4. No difference in mental performance was seen between the first day and the last day of work in each case. An arithmatic test on the first day of the night shift revealed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=3.79, p<0.05). There was a significant difference between the shift groups and the control group(p<0.05) . The digital symbol substitution test and the arithmetic test on the last day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=3.68, p<0.05, F=5.55, p<0.01), and both showed a significant difference between the shift groups and the control group(p<0.05). Accordingly, this study showed that during night duty, the waking time, sleep- wake cycle, and fatigue increased and mental performance decreased compared with morning and evening duty. It was also found that the weekly shift group had a higher fatigue score on the sixth day of night duty as compared to the -first day, but the waking time, sleep- wake cycle, and mental performance revealed no difference for the duration of the night duty or between shift groups, and complete adaptation of temperature rhythm was achieved between the sixth and ninth day of night duty. It is possible to conclude from these results that for intermediate circadian type in a healthy young woman, a biweekly shift system is more compatible with the circadian timing system than weekly shift system.

  • PDF

슬래브축열의 최적제어방책에 관한 연구 -평가요소로 복사열의 고려 유무에 의한 차이- (A Study on the Optimal Control Strategy of Air-Conditioning System with Slab Thermal Storage - The Difference by the Presence of Radiant Heat as a Criterion Factor -)

  • 정재훈;신영기
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.287-296
    • /
    • 2006
  • In this paper, optimal control strategy of the air-conditioning system with slab thermal storage was investigated based on the optimal control theory. An optimal heat output to the plenum chamber and the air-conditioned room was determined based on two kinds of criterion functions. The first one requires small deviation in room air temperature from a set-point value and low energy consumption. It is shown that the optimized control is to store heat through the whole storage time and to increase storage rate gradually with time. As the second case, a criterion that both a deviation of operative temperature from a set-point temperature and the energy consumption should be minimized was adopted. The room air temperature was a little high and the cooling load during storage time was reduced, compared with the results when a criterion function considering only the room air temperature is used.