• 제목/요약/키워드: Temperature Cycling Test

검색결과 116건 처리시간 0.034초

Vivadent의 변연누출에 관한 실험적 연구 (Marginal Leakage Test on 'Vivadent' Composite Resin)

  • 권혁춘
    • 대한치과의사협회지
    • /
    • 제23권12호통권199호
    • /
    • pp.1031-1037
    • /
    • 1985
  • The purpose of this study was to evaluate the marginal sealing ability of 'vivadent.' Using freshly extracted human teeth and 2% aqueous methylene blue, the marginal leakage of dye in restorative materials such as vivadent with acid etching technique, Durafill with acid etching technique, silar with acid etching technique, Adaptic, and Amalgam were investigated at 37℃ and under temperature cycling in range of 4℃-60℃. The results were as follows; 1. All filling materials showed some degree of marginal penetration by 2% methylene blue dye. 2. Vivadent with acid etching technique revealed effective marginal sealing ability, but under temperature cycling it showed increased marginal leakage. 3. All resins showed greater marginal leakage than amalgam restoration. 4. Vivadent had the most effective marginal sealing ability in experimented resins.

  • PDF

Temperature cycling test of Cu films on anodized aluminum substrate of metal-PC application

  • 김형진;박재원
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.334-334
    • /
    • 2011
  • We applied N-ion bombardment and heat treatment to the Cu thin films deposited on aluminum oxide layer for the enhancement of adhesion. With e-beam evaporation method. $1,000{\AA}$ thick Cu pre-bombardment layer was deposited on the aluminum oxide surface and then N-ion beam was bombared in order to mix the atoms at the film/substrate interface. Additional $4,000{\AA}$-thick Cu film was the coated. Subsequently, the ion mixide Cu on aluminum oxide was annealed at $200^{\circ}C$ and $300^{\circ}C$ in vacuum.

  • PDF

Silar(Composite Resin계)의 변연누출(變緣漏出)에 관(關)한 실험적(實驗的) 연구(硏究) (MARGINAL LEAKAGE TEST ON "SILAR" COMPOSITE RESIN)

  • 권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.167-172
    • /
    • 1982
  • The purpose of this study was to evaluate the marginal sealing ability of "Silar". Using freshly extracted human teeth and 2% acquous methylene blue, the marginal leakage of dye in restorative materials such as Silar, Silar with acid etching technique, Hi-Pol, Hi-Pol Enamel Bond system, Adaptic and Amalgam were investigated at $37^{\circ}C$ and under temperature cycling in range of $4^{\circ}C-60^{\circ}C$. The results as follows; 1. All filling materials showed some degree of marginal penetration by 2% methylene blue dye. 2. Silar with acid etching technique revealed effective marginal sealing ability, but under temperature cycling it showed increased marginal leakage. 3. All composite resins showed greater marginal leakage than amalgam restoration. 4. Silar had the most effective marginal sealing ability in experimented composite resins.

  • PDF

Thermo-Mechanical Fatigue Analysis of Ribbon Wire/Ag Electrode Interfaces for PV Module

  • 박노창;홍원식;한창운;김동환
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.48.1-48.1
    • /
    • 2011
  • In this presentation, We monitored weather data, such as global irradiance, ambient temperature, temperature of PV module, relative humidity and windspeed for 2 years, for determining accelerated test condition. then, we determined the temperature limit of accelerated test through weather data and FEM analysis. Detailed procedures will be summarized in this work. After analysing outdoor stress such as thermal stress, we decided main failure modes and mechanisms of PV module, especially solder joint of ribbon wire. we carried out the measurement of material properties such as thermal expansion coefficient for planning of accelerated test. we designed accelerated test based on FEM analysis results. we carried out thermal cycling test with 1 cell mini module for 3 months. We monitored the change of electrical performance every 1 week such as Voc, Isc, Pmax, etc. and then, we analized the ribbon wire/electrode intefaces. Detailed results will be summarized in this work.

  • PDF

형상기억합금 수치해석을 위한 특성 실험 및 작동기 응용 (Experimental Test Numerical Simulation of SMA Characteristics and Device verification)

  • 김상헌;최현호;조맹효
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.145-148
    • /
    • 2005
  • In this study, adaptation of two-way shape memory effect of SMA wire to the actuator is examined . Therefore the SMA characteristics which are training, material properties, response time at different thermal cycling rates are tested. During training, permanent deformation is accumulated till a certain number of cycle and then saturated. The amow1t of two-way strain is unchangeable over all cycle and the slope of strain(or stress)-temperature curve is slower as the increase of applied stress. The rate effect is observed resulted from the thermal distribution which heating profile differs from cooling as thermal cycling time. Using the estimated SMA properties, an experimental test for the simple smart wing is performed.

  • PDF

철도차량 검측모듈의 신뢰성 검증 시험 연구 (A Study of Inspection Module for Verifying Reliability on Railway Vehicle)

  • 나경민;박영;권삼영
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1155-1161
    • /
    • 2017
  • This study examines environmental performance of the arcing measurement module according to international standards. The module assesses the collected current performance using a computer system. The module is required to assess environmental impact resulting from electromagnetic waves, shock and temperature change during train operation. The test includes testing EMI/EMC, vibration, shock and temperature cycling for interface between trains and the arcing measurement module. The module test items were determined in compliance with the standards suggested by the International Electrotechnical Commission (IEC) and Europaische Norm (EN). This study describes the method of test, test equipment operation and how to choose relevant performance standards. The analysis and test results of environmental performance for the module based on computer system are described in this study.

순수점성 비뉴톤유체의 물성치들에 대한 농도 및 온도의 영향 (Effects of the Concentration and the Temperature on the Thermophysical Properties of Purely-Viscous Non-Newtonian Fluid)

  • 조금남
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.670-680
    • /
    • 1994
  • The thermophysical properties of Non-Newtonian fluid as the function of the temperature and the concentration are needed in many rheological heat transfer and fluid mechanics problems. The present work investigated the effects of the concentration and the temperature on the thermophysical properties of purely-viscous Non-Newtonian fluids such as the isobaric thermal expansion coefficient, density, zero-shear-rate viscosity, and zero-shear-rate dynamic viscosity within the experimental temperature range from $25^{\circ}C$ to $55^{\circ}C$. The densities of the test fluids were determined as the function of the temperature by utilizing a reference density and the least square equation for the measured isobaric thermal expansion coefficient. As the concentration of purely-viscous Non-Newtonian fluid was increased up to 10,000 wppm, the densities were proportionally increased up to 0.4%. The zero-shear-rate viscosities of test fluids were measured before and after the measurements of the first thermal expansion coefficients and the densities of Non-Newtonian fluid. Even though they were changed up to approximately 22% due to thermal aging and cycling, they had no effects on the thermal expansion coefficients and the densities of Non-Newtonian fluid. The zero-shear-rate dynamic viscosities for purely-viscous Non-Newtonian fluids were compared with the values for distilled water. They showed the similar trend with the zero-shear-rate viscosities due to small differences in the densities for both distilled water and purely-viscous Non-Newtonian fluid.

알루미늄 확산코팅재료의 주기산화 특성에 관한 연구 (A Study on the Cyclic Oxidation Properties of Aluminum Diffusion Coated Materials)

  • 강석철;민경만;김길무
    • 한국표면공학회지
    • /
    • 제32권1호
    • /
    • pp.49-60
    • /
    • 1999
  • The protective oxide scales and coatings formed on high temperature materials must be preserved in high temperature atmosphere. And the thermal stresses induced by thermal cycling and the growth stresses by the formation of oxide scales can cause the loss of adherence and spalling of the oxide scales and coated layers. Among the coating processes Al diffusion coating is favored due to thermochemical stability and superior adherence in an hostile atmosphere. In this study, protective oxide forming element, Al was coated on Ni, Inconel 600 and 690 by diffusion coating process varying coating temperature and time. And the surface stability and adherence of oxide scales formed on those Al diffusion coated materials were evaluated by thermal cycling test. Al diffusion coated specimens showed superior cyclic oxidation resistance compared to bare ones and specimens coated for longer period had better cyclic oxidation resistance, due to the abundant amount of Al in the coated layer. Meanwhile Al diffusion coated Inconel 600 and 690 showed improved cyclic oxidation resistance by the effect of Al in the coated layer and Cr in the substrate. Comparing both Al diffusion coated Inconel 600 and 690, Al diffusion coated Inconel 690 maintained better adhesion between coated layer and substrate by virtue of the bridging effect resulting from the segregation of Cr in the interdiffusion zone.

  • PDF

Nb 및 Mo 첨가 페라이트계 스테인리스강의 등온 저주기 및 열기계적 피로에 따른 변형거동 (Cyclic Deformation Behaviors under Isothermal and Thermomechanical Fatigue Conditions in Nb and Mo Added 15Cr Ferritic Stainless Steel)

  • 정재규;오승택;최원두;이두환;임종대;오용준
    • 대한금속재료학회지
    • /
    • 제47권11호
    • /
    • pp.707-715
    • /
    • 2009
  • This paper deals with cyclic stress and strain responses during isothermal low cycle fatigue (LCF) and thermo-mechanical fatigue (TMF) loadings on Nb and Mo containing 15Cr stainless steel, which is used for exhaust manifolds in automobiles. The test temperatures ($T_{i}$) of the isothermal LCF were 600 and $800^{\circ}C$. The minimum temperature of the TMF test was $100^{\circ}C$ and the maximum temperaures ($T_{p}$) were varied between 500 and $800^{\circ}C$. In both loading conditions, weak cyclic softening is observed at $T_{i}=T_{p}=800^{\circ}C$, but the transition to strong cyclic hardening is completed with the temperature decrease below $T_i=600{\sim}700^{\circ}C$ for LCF and $T_{p}=500{\sim}600^{\circ}C$ for TMF. The stress-strain hysteresis loops in the TMF loading show a significant stress relaxation during compressive (heating) half cycle at $T_{p}>500^{\circ}C$, which develops tensile mean stress during cycling. Due to the stress relaxation, the TMF test sample reveals much lower dislocation density than the isothermally fatigued sample at the same temperature with $T_{p}$. A detailed correlation between fatigue microstructure and cycling deformation behavior is discussed.

극저온 환경에서 탄소섬유강화 복합재의 인장 물성에 관한 연구 (A Study on Tensile Properties of CFRP Composites under Cryogenic Environment)

  • 김명곤;강상국;김천곤;공철원
    • Composites Research
    • /
    • 제17권6호
    • /
    • pp.52-57
    • /
    • 2004
  • 본 연구에서는 환경 챔버를 이용한 극저온 환경에서, 열.하중 사이클에 따른 탄소섬유강화 복합재의 인장 물성 변화를 고찰하였다. Graphite/epoxy 일방향 복합재 시편에 대하여 시편 상온파손하중의 절반을 가한 상태에서, 상온에서 $-50^{\circ}C$, $-100^{\circ}C$, 그리고 $-150^{\circ}C$ 까지 각각 3회, 6회, 그리고 10회의 열-하중 사이클을 수행한 후 복합재의 인장 강도와 강성을 측정하였다. 그 결과, 온도가 낮아질수록 복합재의 인장 강성은 증가한 반면, 인장 강도는 감소함을 보였다. 그러나 복합재의 인장 강성은 저온 사이클 횟수에 거의 영향을 받지 않았으며 인장 강도는 사이클을 수행하지 않았을 때 보다 오히려 저온 사이클 수행 후 증가함을 확인할 수 있었다. 따라서 실험결과의 고찰을 위해 저온에서 복합재 시편의 열팽창계수를 측정하였고, 주사 전자 현미경 사진을 통해 섬유와 모재의 계면을 분석하였다.