• 제목/요약/키워드: Temperature Check

검색결과 578건 처리시간 0.022초

혈관성 파행 환자에 대한 적외선 체열 촬영의 진단학적 고찰 3례 보고 (3 Cases of Patients with Vascular Claudication, Focussed on the Diagnostic Advantages of Infrared Thermography)

  • 신화영;김재수;임성철;이윤규;이현종;권효정;이봉효;정태영;최우석
    • 한국한의학연구원논문집
    • /
    • 제18권1호
    • /
    • pp.53-57
    • /
    • 2012
  • Objectives : The purpose of this study was to check diagnostic performance of infrared thermography for patients with vascular claudication. Methods : 3 patients with vascular claudication were diagnosed with Digital Infrared Thermal Imaging(DITI) and compared the relative temperature difference between the right and left. Results : Symptomatic legs showed significant low body temperature and at the very site patients complained of pain on, the body temperature differed distinctly between the right and left. Conclusions : Infrared thermographic diagnosis with clinical symptoms may be helpful in diagnosing suspected vascular claudication.

경제성 평가를 이용한 프리쿨링시스템의 국내 적용성 연구 (A Study on Application of the Free Cooling System with Dry Cooler Using Economic Evaluation)

  • 윤정인;손창효;김희민;김영민
    • 동력기계공학회지
    • /
    • 제19권4호
    • /
    • pp.50-55
    • /
    • 2015
  • Recently, because of the deterioration of the nuclear generating station and increase of the cooler and heater, energy problem is increasing. To save the energy, the free cooling system is developed. The free cooling system is that cool the water to use cooled air in winter and is used in industrial process or data center. Yoon check the energy of free cooling system with dry cooler in korea. In this study, the value of the free cooling system with dry cooler is confirmed through using the NPV that is economic evaluation. when temperature degree of the cooled water is 10, in Chuncheon and Seoul the value is the most high. When temperature degree of the cooled water is 20, in Ulsan the value is the most high. As the result, because the using the temperature degree of the cooled water is high in the industrial process, the free cooling system is advantageous in korea.

고밀도 플라즈마에서 규소산화막을 마스크로 이용한 백금박막의 페터닝 (Patterning of Pt thin films using SiO$_2$mask in a high density plasma)

  • 이희섭;이종근;박세근;정양희
    • 전자공학회논문지D
    • /
    • 제34D권3호
    • /
    • pp.87-92
    • /
    • 1997
  • Inductively coupled Cl$_{2}$ plasma has been studied to etch Pt thin films, which hardly form volatile compound with any reactive gas at normal process temperature. Low etch rate and residue problems are frequently observed. For higher etch rate, high density plasma and higher process temperature is adopted observed. For higher etch rate, high density plasma and higher process temperature is adopted and thus SiO$_{2}$ is used as for patterning mask instead of photoresist. The effect of O$_{2}$ or Ar addition to Cl$_{2}$ was investigated, and the chamber pressure, gas flow rate, surce RF power and bias RF power are also varied to check their effects on etch rate and selectivity. The major etching mechanism is the physical sputtering, but the ion assisted chemical raction is also found to be a big factor. The proposs can be optimized to obtain the etch rate of Pt up to 200nm/min and selectivity to SiO$_{2}$ at 2.0 or more. Patterning of submicron Pt lines are successfully demonstrated.

  • PDF

주요 국산재 10가지 수종에 대한 Bi-Sn 저온용융 합금주입 목재복합체의 도장 효과 (Coating Effect of Low Temperature Melting Bi-Sn Metalized Wood Composites on 10 Different Korean Wood Species)

  • 박계신;서인수;이화형;강석구
    • 한국가구학회지
    • /
    • 제25권3호
    • /
    • pp.223-232
    • /
    • 2014
  • To make metalized wood composites of 10 different korean wood species, it was tested by Low temperature melting Bi-Sn alloy injection method at high temperature and high pressure condition. Metalized wood composite of each wood species had light ash color, but still maintained its own natural wood grain and wood figures. It was evaluated on coating properties. Furthermore, it also was check on effect of coating as like a changes of main color, wood grain and wood figures. The results of test were following as; a coating properties as like a cold resistance, heat resistance, acid resistance, alkali resistance, durability of abrasion, and cross-cut test was proper on the conditions of the KS standard. And, In aspect of color changes, the metalized wood composites of 10 different korean wood species had a light ash color, but still maintained its own natural wood grain and wood figures. Also, the more weight per gain of alloy is, the more grey background of metalized wood composite is.

  • PDF

Performance evaluation of bubble pump used on solar water heating system

  • Xuesong, Li;Park, Gi-Tae;Kim, Pil-Hwan;Chung, Han-Shik;Jeong, Hyo-Min
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.416-422
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and their relationship with the solar radiation intensity. The theory analysis of design bubble pump has been given and the experiment result analysis has been included in the paper.

  • PDF

Ethylene Oxide 가스 멸균물품의 유효기간에 관한 연구 - 보관환경을 중심으로 - (A Study on Expiration Date on Ethylene Oxide Gas Sterilization Products - Related to Storage Environment -)

  • 손정숙;유일경
    • 기본간호학회지
    • /
    • 제21권2호
    • /
    • pp.141-150
    • /
    • 2014
  • Purpose: This was a study on the expiration date of Ethylene Oxide (EO) gas sterilization and effects of the environmental factors of temperature, humidity and type of cabinet in sterile goods storage area on the expiration date. Methods: Sterile goods storage areas from 13 departments in one hospital were selected and 455 EO gas sterilization samples were prepared and kept in those areas over the 14 months of the study. Each sample was tested with a microbiological culture in the laboratory every week. If the result was positive, the sample was regarded as contaminated. The researcher visited once a month to check the temperature, humidity and type of cabinet. Results: With the exception of 1 sample which was positive at 56th week. 454 samples were confirmed as negative. The environment of the samples storage area was measured monthly. The annual average temperature was $24.2{\pm}1.6^{\circ}C$, and the mean relative humidity $34.7{\pm}15.2%$. The types of cabinet were 7 open and 6 closed. Conclusion: The results of the microbiological culture at 13 months showed that none of the samples were contaminated. Therefore the hospital's existing Expiration Date can be extended from 6 months to 13~14 months.

Si 선택적 성장을 위한 대형 CVD 반응기 내의 열 및 유동해석 (Analysis on the Flow and Heat Transfer in a Large Scale CVD Reactor for Si Epitaxial Growth)

  • 장연호;고동국;임익태
    • 반도체디스플레이기술학회지
    • /
    • 제15권1호
    • /
    • pp.41-46
    • /
    • 2016
  • In this study, gas flow and temperature distribution in the multi-wafer planetary CVD reactor for the Si epitaxial growth were analyzed. Although the structure of the reactor was simplified as the first step of the study, the three-dimensional analysis was performed taking all these considerations of the revolution of the susceptor and the rotation of satellites into account. From the analyses, a reasonable velocity field and temperature field were obtained. However, it was found that analyses including the upper structure of the reactor were required in order to obtain more realistic temperature results. DCS mole fraction above the satellite surface and the susceptor surface without satellite was compared in order to check the gas species mixing. We found that satellite rotation helped gases to mix in the reactor.

갈색 Type I 다이아몬드의 고압 열처리에 따른 표면 흑연화 생성 연구 (Surface Graphite Formation of the Brown Colored Type I Diamonds During High Pressure Annealing)

  • 송정호;송오성
    • 한국세라믹학회지
    • /
    • 제49권6호
    • /
    • pp.614-619
    • /
    • 2012
  • We investigated color and graphite layer formation on the surface of Type I tinted brown diamonds exposed for 5 minutes under a high-pressure high-temperature (HPHT) condition in a stable graphite regime. We executed the HPHT processes of Process I, varying the temperature from $1600^{\circ}C$ to $2300^{\circ}C$ under 5.2 GPa pressure for 5 minutes, and Process II, varying the pressure from 4.2 to 5.7 GPa at $2150^{\circ}C$ for 5 minutes. Optical microscopy and micro-Raman spectroscopy were used to check the microstructure and surface layer phase evolution. For Process I, we observed a color change to vivid yellow and greenish yellow and the growth of a graphite layer as the temperature increased. For Process II, the graphite layer thickness increased as the pressure decreased. We also confirmed by 531 nm micro-Raman spectroscopy that all diamonds showed a $1440cm^{-1}$ characteristic peak, which remained even after HPHT annealing. The results implied that HPHT-treated colored diamonds can be distinguished from natural stones by checking for the existence of the $1440cm^{-1}$ peak with 531 nm micro-Raman spectroscopy.

Transient thermoelastic analysis of carbon/carbon composite multidisc brake using finite element method

  • Ghashochi-Bargh, Hadi;Goodarzi, Mohammad-Saeed;Karimi, Masoud;Salamat-Talab, Mazaher
    • Advances in aircraft and spacecraft science
    • /
    • 제7권2호
    • /
    • pp.135-149
    • /
    • 2020
  • In the current paper, a generalization of the results of Zhao et al. (2008) on a new design of C/C composite multidisc brake system is presented. The purpose of this paper is to study the effect of thermal sensitivity of Carbon/Carbon (C/C) composite material on the temperature distributions, deformation, and stress during braking. In this regard, a transient temperature-displacement coupled analysis for C/C composite brake discs with frictional heat generation under simulated operating conditions is performed. An axisymmetric model for brake system is used for the finite element analysis according to the theory of energy transformation and transportation. The transient temperature distributions on the friction surfaces, deformation, and stress are obtained. To check the validity, the results are corroborated with other solutions available in the literature, wherever possible. The current study could be used as a guide in the initial design of a high performance multidisc brake system.

스마트 양식장 수조 내 용존 산소 및 온도 제어를 위한 시스템 구현 (An Implementation of System for Control of Dissolved Oxygen and Temperature in the pools of Smart Fish Farm)

  • 전주현;이윤호;이나은;주문갑
    • 대한임베디드공학회논문지
    • /
    • 제16권6호
    • /
    • pp.299-305
    • /
    • 2021
  • Dissolved oxygen, pH, and temperature are the most important factors for fish farming because they affect fish growth and mass mortality of the fish. Therefore, fish farm workers must always check all pools on the farm, but this is very difficult in reality. That's why we developed a control system for smart fish farms. This system includes a gateway, sensor gatherers, and a PC program using LabVIEW. One sensor gatherer can cover up to four pools. The sensor gatherers are connected to the gateway in the form of a bus. For the gateway, the ATmega2560 is used as the main processor for communication and the STM32F429 is used as a sub-processor for displaying LCD. For the sensor gatherer, ATmega2560 is used as the main processor for communication. MQTT (Message Queuing Telemetry Transport), RS-485, and Zigbee are used as the communication protocols in the control system. The users can control the temperature and the dissolved oxygen using the PC program. The commands are transferred from the PC program to the gateway through the MQTT protocol. When the gateway gets the commands, it transfers the commands to the appropriate sensor gatherer through RS-485 and Zigbee.