• Title/Summary/Keyword: Temperature/humidity

Search Result 4,333, Processing Time 0.029 seconds

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Low-Priced Generic Ceramic Panel Materials for Humidity Control - Focuses on analyzed measurements of temperature and humidity obtained from the housing units - (저가보급형 습도조절용 세라믹패널의 조습성능 평가 - 리빙랩 온·습도 모니터링 분석을 통한 실측결과를 중심으로 -)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.39-40
    • /
    • 2017
  • This study aims to evaluate the humidity control performance of low-priced generic ceramic panels that are used to control humidity. Temperature and humidity are monitored by using 'Living Lab' and the change of indoor relative humidity is measured and analyzed. According to the results of the study, the indoor relative humidity of rooms installed with ceramic panels was found to be low compared to that of living rooms by 2.2%RH (test period) and 3.2%RH (daily). In the case of maximum relative humidity, rooms installed with ceramic panels were found to be low by 6.9%RH. The results are attributable to the humidity absorption of ceramic panels. Accordingly, future ceramic panels need the improvement of performance and an appropriate construction area should be derived depending on indoor space.

  • PDF

On the Breeding of Dumbbell Bivoltine Silkworm Breeds of Bombyx mori L. Tolerant to High Temperature and High Humidity Conditions of the Tropics

  • Singh, Harjeet;Kumar, Nair Suresh
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.20 no.2
    • /
    • pp.45-59
    • /
    • 2010
  • It is well established fact that under tropical condition, unlike polyvoltines, bivoltines are more vulnerable to various stresses i.e. hot climatic conditions of tropics, poor leaf quality and improper management during summer which are not conducive for bivoltine rearing. Therefore, attempt has been made in this study to develop promising bivoltine breeds tolerant to high temperature and high humidity conditions of the tropics. In the present study, by utilizing temperature tolerant breeds six breeding lines were made and at every generation the 5th instar larvae were exposed to high temperature and high humidity and the survived ones were back crossed with the breeds moderately tolerant to diseases were made to improve the quantitative traits. From F6 generations, alternate rearing in normal temperature and high temperature were conducted. At the end of F12 generation, it was possible to isolate three dumbbell breeds viz., HH8, HH10 and HH12 with improvement in quantitative traits. The methodologies followed for the development are discussed.

Development of Realtime Temperature & Humidity Logging and Monitoring System using Ubiquitous Sensor Network (유비쿼터스 센서 네트워크를 이용한 실시간 온.습도 기록 및 모니터링 시스템 개발)

  • Cheon, Seong-Sim;Kim, Jung-Ja;Won, Yong-Gwan;Pham, Hai Trieu
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.2
    • /
    • pp.96-105
    • /
    • 2011
  • Ubiquitos sensor network(USN) is a technology which is widely used in our life. This paper introduces an example of design and implementation for a system which is based on the USN technology and can provide an efficient management tool for a space that should be precisely controlled for a certain range of uniformity in temperature and humidity. This introduced system builds a wireless sensor network using a number of sensor modules that are equipped with temperature and humidity sensors, and collects temperature and humidity information in real-time while simultaneously providing a method for monitoring the status of temperature and humidity by the graphical user interface. Also, the system will give a warning signal if the monitored values are differ from the pre-specified values of temperature and humidity for each sensor module more than a certain amount of tolerance. This temperature and humidity logging and monitoring system can perform better management for the space easily and efficiently by automating the existing manual method for data collection and management. Furthermore, using the stored data, it can make possible to perform post-analysis on the problems caused by temperature and humidity and to obtain information for environmental enhancement for the space.

An Analysis of Forest Fire Occurrence Hazards by Changing Temperature and Humidity of Ten-day Intervals for 30 Years in Spring (우리나라의 봄철 순평년 온습도 변화에 따른 산불발생위험성 분석)

  • Won, Myoung-Soo;Koo, Kyo-Sang;Lee, Myung-Bo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.8 no.4
    • /
    • pp.250-259
    • /
    • 2006
  • This study looks into forest fire occurrence hazards according to the change of temperature and humidity over thirty years at interval of ten days. We used data from the forest fire inventory from 1995 to 2004 and weather data such as average temperature and relative humidity for 30 years from 1971 to 2000. These data were expressed as a database with ten-day intervals for 76 weather stations. Forest fire hazards occurred in the spring season from the end of March to the middle of April. For the first step, the primitive surface of temperature and humidity was interpolated by IDW (the standard interpolation method). These thematic maps have a 1 km by 1 km grid spacing resolution. Next, we executed a simple regression analysis after extracting forest fire frequency, temperature and humidity values from 76 weather stations. The results produced a coefficient of determination ($R^2$) ranging from 0.4 to 0.6. Moreover, the estimation of forest fire occurrence hazards during early April was very high at Gyeongbuk Interior, Chungcheong Interior and part of Gangwon. The range of temperature and humidity having an influence on forest fire occurrence was as follows: average temperature and relative humidity in early April was $9-12^{\circ}C$ and 61-65%. At the end of March, temperature was $6-10^{\circ}C$, humidity 62-67%, and temperature was $11-14^{\circ}C$ and humidity 60-67% in the middle of April.

Observation of Moisture Content in Wood at Non-Steady State

  • Hwang, Sung-Wook;Lee, Won-Hee
    • Journal of the Korea Furniture Society
    • /
    • v.20 no.6
    • /
    • pp.599-604
    • /
    • 2009
  • For the search of unified law of moisture movement in wood, moisture distribution of Korean red pine at non-steady state was investigated. We assume that the equilibrium moisture content (EMC) in wood depends on only temperature and relative humidity, it can be control in temperature and humidity chamber. If temperature is constant and humidity or vapor pressure is changed with sin curve shape at adequate cycles, EMC in chamber can be changed as well with sin-curve shape. The setup condition of a non-steady state in humidity control chambers is a constant temperature at $20^{\circ}C$ and 15+10 sin ${\omega}t$ percent EMC. It can be found that the distribution of moisture in the specimen with varying relative humidity are illustrated various types. Moisture in wood is complicated and vibrates with the moisture sorption process. Considering a unified law of moisture movement in wood, it is considered that the most important fact is to search the method of precise diffusion & transfer coefficients.

  • PDF

Dynamic Simulation of a Dedicated Outdoor Air-conditioning System (외기 전용 공조기의 동특성 시뮬레이션)

  • Kim, Jung-Min;Kim, Young-Il;Chung, Kwang-Seop;Park, Seung-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.322-327
    • /
    • 2007
  • Dedicated outdoor air-conditioning(DOA) system that utilizes pre-cooling and desiccant dehumidification can be superior to conventional cooling and reheating system with respect to energy consumption and indoor thermal comfort. In this work, simulation has been conducted to study various factors that affect the performance of DOA. Dynamic simulation shows the transient variation of temperature and humidity as the on/off control logic is imposed. Exit humidity of process air and flow rate are varied to study the effect on exit temperature of process air, dehumidification quantity, required regeneration temperature and exit humidity of regeneration air. For an outdoor air condition of $28.5^{\circ}C$ temperature, 16 g/kg humidity ratio and 2000 cmh flow rate, the dehumidification efficiency is increased by 4.6% as the flow rate is doubled.

  • PDF

Positive Study of How Green Zones in the City Effect the Relief of Micro-Climate Control (도시녹지가 미기상조절에 미치는 실증적 연구)

  • 윤용한
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.2
    • /
    • pp.279-286
    • /
    • 2004
  • This study observed the temperature and humidity within the green zone to understand the effect that land coverage and the structure of forests have on the relief of micro-climate control. Based on this set of data, this study interpreted, through the regression analysis, the relevance of land coverage of the green zone with temperature and distribution of humidity, as well as the amount of green with the relief of microclimate control. The results of the study demonstrated that high temperature regions were formed in barren areas, and low temperature regions in forests or near the water. In particular, low temperature was found in areas covered with tall and small trees, the water surrounded by forests and areas enclosing small rivers. Furthermore, mechanisms causing low temperature were, among others, the ratio of land coverage (forest, grassland, water). In fact, the temperature reduction effect varied in accordance with the types and ratios of the land coverage. Humidity also showed a close correlation with the distribution of temperature high temperature areas had low humidity and low temperature areas had high humidity. Such a phenomenon.

A study of Agricultural fatigue shoes - A comparative study of heat load by shoe type - (농작업화에 관한 연구 - 신발종류에 따른 열적 부담 비교연구 -)

  • 이경숙;최정화
    • Korean Journal of Rural Living Science
    • /
    • v.7 no.2
    • /
    • pp.99-108
    • /
    • 1996
  • This study has intended to suggest fundamental data to develope and choose appropriate shoes for upland farming in order to prevent health deterioration of women workers and improve work effectiveness and reduce fatigue by wearing appropriate shoes. During 1995. 4. 28 - 5. 10, Fifty women workers in hot pepper farming were observed and major shoe types, which were rubber shoes, walking shoes, slippers, and rubber boots, were selected for the study. During 1995. 10. 9 - 31, two subjects were tested by wearing those shoes in the laboratory where the temperature was 24$\pm$1$^{\circ}C$ and relative humidity 50$\pm$5%RH. And the temperature & humidity on sole and in the shoes, the rectal temperature, skin temperature, blood pressure, pulse, lactate concentration of blood, Flickers' value and subjective sensation were measured. The results were as follows : 1. 84% of women workers mentioned that they need shoes improvement and the order of most frequent shoe types to be worn was rubber shoes, walking shoes, slippers, rubber boots. 2. The rate of women who were unsatisfied with shoes for upland farming is 38 percentages. The reason of unsatisfaction was that feet were in a sweat and alien substances were let into shoes. 3. The temperature & humidity on sole were the lowest in rubber boots during experiment(p<0.01). 4. The relative humidity in the shoes was the highest in rubber boots by 90% and the lowest in walking shoes by 72% during rest And the humidity in slippers and walking shoes were significantly low in experiment(p<0.001). 5. Rubber boots showed the highest rise in rectal temperature by 0.2$^{\circ}C$ showing increase of core temperature (p<0.05). 6. The mean skin temperature during experiment was highest in rubber boots by 33.8$^{\circ}C$(p<0.001).

  • PDF

Development of a Refrigeratory-Based Dehumidifier for Humidity Environment Control in Greenhouse (시설원예 습도환경 제어를 위한 냉각식 제습기 개발)

  • Kang, G.C.;Yon, K.S.;Ryou, Y.S.;Kim, Y.J.;Kang, Y.K.;Paek, Y.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.4
    • /
    • pp.247-255
    • /
    • 2007
  • During the winter season in Korea, the relative humidity of greenhouse at night often exceeds 90% because air temperature inside the greenhouse is usually controlled using a heater with all of windows closed to minimize heat loss, thereby requiring the use of a dehumidifier that can maintain optimum humidity levels of $70{\sim}80%$ to provide a good growth condition of crops. Also, such a high humid condition can cause the development of a pest, such as insects, fungi or diseases. However, the use of most conventional dehumidifiers for low temperature dehumidification is limited because their performance is degraded due to frost accumulation on the evaporator coil. This study was carried out to develop a refrigeratory-based dehumidifier suitable for low temperature dehumidification in greenhouse cultivation. The developed dehumidifier consists of a condenser and an evaporator installed separately so that relative and absolute humidity levels can be reduced when air passed through the condenser and evaporator, respectively. The prototype dehumidifier showed a dehumidification capacity of $5{\sim}7kg/h$ when air with a temperature of $15{\sim}25^{\circ}C$ and a relative humidity of $70{\sim}95%$ came into the dehumidifier. Under the condition that either temperature or relative humidity was fixed, the amount of condensed water was proportional to the levels of both temperature and relative humidity.