• Title/Summary/Keyword: Tele research

Search Result 146, Processing Time 0.025 seconds

Current Status of Layer Transfer Process in Thin Silicon Solar Cell : a review

  • U. Gangopadhyay;K. Chakrabarty;S.K. Dhungel;Kim, Kyung-Hae;Yi, Jun-Sin;D. Majumdar;H. Saha
    • Transactions on Electrical and Electronic Materials
    • /
    • 제5권2호
    • /
    • pp.41-49
    • /
    • 2004
  • Layer transfer process has emerged as a promising tool in the field of thin silicon solar cell technology. This process can use mono-crystalline silicon as a surface for the epitaxial growth of a thin layer of silicon. It requires some sort of surface conditioning of the substrate due to which the surface become suitable for homo-epitaxy and lift off after solar cell fabrication. The successful reuse of substrate has been reported. The use of the conditioned surface without any kind of epitaxial layer growth is also the issue to be addressed. This review paper basically describes the five most cost effective methods on which works are in progress. Several types of possible problems envisaged by different research groups are also incorporated here with necessary discussion. Work in Korea has already started in this area in collaboration IC Design and Fabrication Centre, Jadavpur University, India and that also has been mentioned.

Wearable Approach of ECG Monitoring System for Wireless Tele-Home Care Application

  • Kew, Hsein-Ping;Noh, Yun-Hong;Jeong, Do-Un
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 춘계학술대회
    • /
    • pp.337-340
    • /
    • 2009
  • Wireless tele-home-care application gives new possibilities for ECG (electrocardiogram) monitoring system with wearable biomedical sensors. Thus, continuously development of high convenient ECG monitoring system for high-risk cardiac patients is essential. This paper describes to monitor a person's ECG using wearable approach. A wearable belt-type ECG electrode with integrated electronics has been developed and has proven long-term robustness and monitoring of all electrical components. The measured ECG signal is transmitted via an ultra low power consumption wireless sensor node. ECG signals carry a lot clinical information for a cardiologist especially the R-peak detection in ECG. R-peak detection generally uses the threshold value which is fixed thus it bring errors due to motion artifacts and signal size changes. Variable threshold method is used to detect the R-peak which is more accurate and efficient. In order to evaluate the performance analysis, R-peak detection using MIT-BIH databases and Long Term Real-Time ECG is performed in this research. This concept able to allow patient to follow up critical patients from their home and early detecting rarely occurrences of cardiac arrhythmia.

  • PDF

부정맥 시술을 위한 마스터-슬레이브 원격제어·로봇 시스템 개발 (Development of Master-Slave Type Tele-Operation Control Robotic System for Arrhythmia Ablation)

  • 문영진;박상훈;후젠카이;최재순
    • 제어로봇시스템학회논문지
    • /
    • 제22권8호
    • /
    • pp.585-589
    • /
    • 2016
  • Recently, the robotic assist system for cardiovascular intervention gets continuously growing interest. The robotic cardiovascular intervention systems are largely two folds, systems for cardiac ablation procedure assist and systems for vascular intervention assist. For the systems, the clinician controls the catheter inserted through blood vessel to the heart via a master console or master manipulator. Most of the current master manipulators have structure of joystick-like pivoting 2 degree of freedom (DOF) handle in the core, which is used in parallel with other sliding switches and input devices. It however is desirable to have customized and optimized design manipulator that can provide clinician with intuitive control of the catheter motion fully utilizing the advantage of the use of robotic structure. A 6 DOF kinematic mechanism that can capture the motion control intention of the clinician in translational 3 DOF and rotational 3 DOF is proposed in this paper. Also, a master-slave motion relationship specially designed for the cardiac catheter manipulation motion is proposed and implemented in an experimental prototype. Design revision for implementation of more efficient motion and experiment in combination with an experimental slave robot system for catheter manipulation are underway.

보건소 한방지역보건사업 중 기공체조교실의 현황 파악 및 활성화 방안 (Vitalization Measures of the Class for Qi-gong Gymnastics in the Public Health Center)

  • 한창현;정대선;박수진;권영규
    • 한국한의학연구원논문집
    • /
    • 제13권1호통권19호
    • /
    • pp.115-124
    • /
    • 2007
  • Objectives : The study investigated the actual condition of the class for Qi-gong gymnastics among health promotion service programs using oriental medicines, which the public health center has been conducting for local residents. Method : Of a total of 964 oriental medical physician in public health center across the country, it examined 27 places consisting of public health centers and public health sub-centers, and public hospitals, all of which were running the class for Qi-gong gymnastics. Then, it carried out the tele research of those oriental medical physicians in charge of the class there. Result : As a result, area that is enforcing the Class for Qi-gong Gymnastics was expose each attempt that difference is particularly, and appeared by thing which form and practice law that operate the classroom are various. Also, in many cases, the oriental medical physicians instructed the gymnastics directly instead of inviting an external lecturer. Conclusions : In conclusion, based on the contents surveyed, by making the well-organized system of the class for Qi-gong excercise; by developing the common excercise and texts; and by publicizing and educating the oriental medical physicians engaged in public health, that the Class for Qi-gong Gymnastics is real in health promotion of local residents.

  • PDF

공간정보기반 CCTV 제원정보 자동 매핑 알고리즘 개발 (Development of Automatic Mapping Algorithm using CCTV Information based on Geo-spatial Information)

  • Cho, Myeongheum;Park, Youngjin;Lee, Junwoo;Kim, KyeHyun
    • 한국재난정보학회 논문집
    • /
    • 제12권2호
    • /
    • pp.181-188
    • /
    • 2016
  • 본 연구에서는 시범지역의 CCTV 제원정보를 전수조사 하여 CCTV 위치, 주감시방향, 감시거리, 최대감시거리, Tele mode 화각, Wide mode 화각 등 CCTV 정보를 표출하기 위한 기본요소를 DB화 하였다. 조사된 CCTV제원 정보를 기초로 하여 공간정보 기반으로 도식화, 시각화 할 수 있는 자동 매핑 알고리즘 제안하였다. 알고리즘을 적용한 결과, 일부 연구지역의 CCTV 위치가 약 11% 중복된 것으로 분석되었고, CCTV 12대 가운데 중복된 CCTV는 총 5대로 도출되었다. 향후, 제시한 알고리즘을 기반으로 CCTV제원 정보를 지도에 표출하여 CCTV 위치 재설계 및 감시방향 변경 등 보다 과학적인 근거자료로 활용이 가능할 것이다.

NGOSS 기반의 TMForum 동향분석 (Analysis of Trend of TeleManagement Forum Based NGOSS)

  • 전덕중;남기동;이준경
    • 전자통신동향분석
    • /
    • 제20권6호통권96호
    • /
    • pp.122-131
    • /
    • 2005
  • TMForum에서는 서비스 공급자 및 네트워크 운용자로 하여금 비즈니스 프로세스를자동화 할 수 있도록 하는 솔루션을 제공하여 비용 및 시간 절감 효과를 가져오기 위한 지속적인 활동을 수행하고 있으며, 비즈니스 프로세스 운용을 위한 시스템적인 지원뿐만 아니라 구조적 아키텍처를 수립하기 위해 NGOSS, ETOM, SLAM 등의 다양한 기술적인 활동이 진행되고 있다. 본 고에서는 TMForum의 활동목적과 주요 프로그램 활동 사항을 살펴보기로 한다

원격 환경 모니터링을 위한 Data Logger 개발 (Development of Data Logger for Environmental Tele Monitoring System)

  • 정광조;이재종;이수호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1097-1100
    • /
    • 2003
  • Data Loggers for environmental monitoring are mostly dispersion in installation and systems located at long distance from monitoring system. And, it requests mostly flexible functions and high performances. that can fit to various sensor inputs, sensor interfaces and conditions or system working. In this research, we developed the micro controller based Data Logger with minimum hardware construction that allows the higher flexibility of application. Finally, we developed software function for water quality monitoring and tested in real system launched at Han river.

  • PDF