• Title/Summary/Keyword: Teflon membrane

Search Result 23, Processing Time 0.024 seconds

EFFECT OF TEFLON MEMBRANE AND NYLON MEMBRANE ON GUIDED BONE REGENERATON IN RABBIT TIBIA (가토 경골 골결손부에서 Nylon Membrane과 Teflon Membrane의 골유도 재생 효과)

  • Kim, Kwan-Shik;Cho, Byoung-Ouck;Lee, Young-Chan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.2
    • /
    • pp.146-153
    • /
    • 2000
  • The purpose of present study is comparing the effect of Teflon Membrane and Nylon Membrane on bone regeneration in rabbit tibia. The 6 defects of $8{\times}8{\times}5mm$ size were drilled with dental handpiece in rabbit tibia, which on left side as an order of Control group(no coverage), Group 1(Nylon $5{\mu}m$ size), Group 3(Nylon $10{\mu}m$ size), and on right side Control group, Group 2($5{\mu}m$ Teflon), Group 4($10{\mu}m$ Teflon). Animals were killed at 7, 10, 14, 42 days to make specimens and observed the difference of healing potentials with light microscopy. The results were as follows ; 1. New bone formation has taken place at 14 days in Guided Bone Regeneration (GBR) group comparing to the Control group of massive inflammatory status. 2. Larger pore membrane allows more favorable healing potentials. Bone formation started earlier in larger membrane pore groups than smaller groups, until 14 days. 3. Bone forming potentials of Teflon membrane group was higher than Nylon membrane groups, Control group has the lowest bone forming potentials. 4. New bone formation was almost ended in 42 days, and there was no difference of bone formation between Nylon and Teflon membrane group of different size. There was no difference of bone formation at final stage(42 days) between Nylon membrane and Teflon membrane of same pore size. So nylon membrane may be clinically usable in guided bone regeneration case with further studies.

  • PDF

Fabrication of Polysulfone Hollow Fiber Membranes for N2/NF3 Separation (N2/NF3 분리용 폴리썰폰 중공사막 제조 연구)

  • Lim, Min Su;Kim, Seong-Joong;Kang, Ha Sung;Park, Ho Bum;Nam, Seung Eun;Park, Ho Sik;Lee, Pyung Soo;Park, You In
    • Membrane Journal
    • /
    • v.26 no.1
    • /
    • pp.76-85
    • /
    • 2016
  • Fabrication of polysulfone (PSf) hollow fiber membranes was investigated for the separation of $N_2/NF_3$ gas mixtures, which are emitted from the display and the semiconductor industries. A combination of the non-solvent induced phase separation (NIPS) and the vapor-induced phase separation (VIPS) technique was applied to develop high flux hollow fiber membranes. Thin polymer layers were further coated onto the surface of the hollow fiber membranes by using polydimethylsiloxiane (PDMS) or Teflon AF1600(R), which contributes to improve the $N_2/NF_3$ selectivity. The $N_2/NF_3$ separation performances of our PSf hollow fiber membranes were determined by the intrinsic properties of coating materials. Especially, the PSf hollow fiber membrane coated with Teflon AF 1600(R) exhibited a higher $N_2/NF_3$ selectivity (> 14) with a slightly lower $N_2$ permeance (4.5 GPU), as compared to the commercial PSf counterparts. This feature provides a good potential as a membrane structure to separate $N_2/NF_3$.

A Comparison of Lyophilized Amniotic Membrane with Cryopreserved Amniotic Membrane for the Reconstruction of Rabbit Corneal Epithelium

  • Ahn Jae-Il;Jang In-Keun;Lee Doo-Hoon;Seo Young-Kwon;Yoon Hee-Hoon;Shin Youn-Ho;Kim Jae-Chan;Song Kye-Yong;Lee Hee-Gu;Yang Eun-Kyung;Kim Ki-Ho;Park Jung-Keung
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.10 no.3
    • /
    • pp.262-269
    • /
    • 2005
  • Many researchers have employed cryopreserved amniotic membrane (CAM) in the treatment of a severely damaged cornea, using corneal epithelial cells cultured on an amniotic membrane (AM). In this study, two Teflon rings were made for culturing the cells on the LAM and CAM, and were then used to support the AM, which is referred to in this paper as an Ahn's AM supporter. The primary corneal epithelial cells were obtained from the limbus, using an ex-plantation method. The corneal epithelium could be reconstructed by culturing the third­passage corneal epithelial cells on the AM. A lyophilized amniotic membrane (LAM) has a higher rate of graft take, a longer shelf life, is easier to store, and safer, due to gamma irradiation, than a (AM. The corneal epithelium reconstructed on the LAM and (AM, supported by the two­Teflon rings, was similar to normal corneal epithelium. However, the advantages of the LAM over that of the (AM make the former more useful. The reconstruction model of the corneal epithelium, using AM, is considered as a good in vitro model for transplantation of cornel epithelium into patients with a severely damaged cornea.

Ethanol Productivity in a Hollow Fiber Membrane Module Using High Density of Saccharomyces cerevisiae (실관반응기 내의 Saccharomyces cerevisiae의 고농도 배양을 이용한 에탄올 생산성)

  • 장호남;양지원박용석정봉현
    • KSBB Journal
    • /
    • v.7 no.1
    • /
    • pp.67-71
    • /
    • 1992
  • We studied a continuous production of ethanol by Saccharomyces cerevisiae in a hollow fiber membrane bioreactor which consisted of 50 polypropylene fibers and 3 teflon fibers. The produced $CO_2$ was removed through the teflon fibers and excess biomass was removed through the shell side. We obtained the cell and ethanol concentrations of 266g/L and 205g/L based on the shell-side volume. A nitrogen deficient medium resulted in too low an ethanol productivity to be applied to a practical process.

  • PDF

Case Study on Sound Absorption Rate Measurement Method of PTFE Membrane Material (테프론(PTFE) 막재료의 흡음율 측정방법에 대한 연구)

  • Park, Hye-Na;Kim, Jung-Joong;Shon, Jang-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.645-648
    • /
    • 2005
  • The grounds of multipurpose practical use degree are built much holding world cup 2002 but material that is used in this building most external membrane ceiling is accomplishing PTEE A master and servant. Therefore, this research analyzed assessment about sound absorption special quality that measure ventilation quantitys of 10 act material and analyze correlation with Air Permeability and the sound absorption rate, and follow in change of layer of air of inside facts material. Result is as following. When Air Permeability good dimension is 5$\sim$15 cc/cm$^2$/sec and acoustic absorptivity is the best as Air Permeability result that measure acoustic absorptivity of inside facts material particularly firstly, could know 8$\sim$9 cc/cm$^2$/sec love. When establish sound absorption inside facts in external membrane as result that measure acoustic absorptivity of inside (acts material secondly, could know that acoustic absorptivity is good though become about minimum back layer of air 900mm.

  • PDF

Development of Portable-Type Electrode for the Determination of Highly Concentrated Hydrogen Peroxide (휴대용 고농도 과산화수소 측정 전극의 개발)

  • Lee, Jin Seo;Cui, Gang;Kim, Sang Jin;Cha, Geun Sig;Nam, Hakhyun;Rho, Kyung Lae;Kim, Jin Doo
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.125-129
    • /
    • 1999
  • Portable-type two electrode system for the determination of highly concentrated hydrogen peroxide (10-75%) has been studied. The electrode body was made with teflon rod (length=10 cm, diameter=1.5 cm) to withstand the highly corrosive power of hydrogen peroxide. Glass carbon rod (diameter=3 mm) was used as the working electrode and a carbon cylinder (i.d.=5 mm; o.d.=9 mm) was used as counter electrode. The applied voltage for the determination of $H_2O_2$ was 0.8 V. Diluting the highly concentrated samples taken from the industrial batch to 10% or less, it was possible to make quantitative determinations, while eliminating the interference from the stabilizer contained in the sample and preventing the surface of the electrode from oxidative corrosion. Employing hydrogen peroxide permeable membrane (teflon membrane${\leq}100{\mu}m$) for the electrode system, it was possible to measure the content of $H_2O_2$ in highly concentrated samples directly, quantitatively and reproducibly with no extra dilution step. However, it was necessary to change the internal electrolyte frequently to maintain the analytical performance of the electrode.

  • PDF

A study on the pulp and paper mills waste water Recycling by VSEP membrane system (진동막 분리장치를 이용한 제지폐수의 재이용에 관한 연구)

  • 지은상;김재우;신대윤
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.40-46
    • /
    • 2001
  • Conventional membrane systems was difficult to treatment for pulp and paper mills waste warter. Technological advances in membrane filtration systems have created opportunity for pulp and paper mills to treat effluent streams in order to meet stricter environmental constraints. "Vibratory Shear Enhanced Processing(VSEP)" developed by new logic international makes if possible to filter effluent streams without the fouling problems exhibited by conventional membrane systems. Various kinds of waste water occurred to and paper mills experiment with "VSEP" set up conventional membrane. The results were as followes : Excepting ultra filter($0.1{\mu}\textrm{m}$ Teflon, C-100, G-50), Nano filter(NTR-7450, DS-5, PVD-1) and reverse osmosis(ACM-4) was treated with very excellent weight of treatment, electric conductivity, removal COD, TDS, turbidity.

  • PDF

A Comparison Study of CFD Analysis and Flow Visualization on Behavior of Liquid Water in Cathode Channels of PEM Fuel Cells (PEM 연료전지 공기극 유로에서 물의 거동에 대한 CFD 해석과 가시화 실험의 비교 연구)

  • Kim, Hyun-Il;Nam, Jin-Hyun;Shin, Dong-Hoon;Chung, Tae-Yong;Kim, Young-Gyu;Seo, Won-Seok;Lee, Jung-Woon
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2008.04a
    • /
    • pp.101-108
    • /
    • 2008
  • Polymer electrolyte membrane (PEM) fuel cells are promising power generation devices which are ideal for residential and automobile applications, thanks to their fast transient characteristics. However, liquid water produced in PEM fuel cells should be properly managed to enhance the performances and durabilities of the cells. In this study, a visualization experiment was conducted to investigate the flow behavior of water droplets in cathode channels. The visualization experiment was done with four different model flow channels which were made by varying the material (Acrylic and Teflon) and the channel width (1 mm and 2 mm). Acrylic is hydrophilic (contact angle is about $80^{\circ}$) while Teflon is hydrophobic (contact angle is about $120^{\circ}$). A computational fluid dynamics (CFD) analysis was also performed to compare the observed and the simulated two-phase water/air flow characteristics in cathode channels. The computational models were made to be consistent with the geometries and surface properties of the model flow channels. Both the experimental and numerical results showed that the Teflon cathode channel with 1 mm width has the best water management performance among four model flow channels considered. A close correlation was found between the experimental visualization results and the numerical CFD simulation results.

  • PDF

Sulfonated Polystyrene/PTFE Composite Membranes for Direct Methanol Fuel Cell (직접 메탄올 연료전지를 위한 술폰화 폴리스티렌/테플론 복합막 제조 및 특성연구)

  • 김정훈;신정필;박인준;이수복;서동학
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.173-184
    • /
    • 2004
  • For the application of direct methanol fuel cell (DMFC), sulfonated polystyrene/teflon (PS/PTFE) composite membranes were developed by changing monomer ratio of styrene and DVB. The composite membranes were prepared as follows: first, the monomer mixtures consisting of styrene, divinyl benzene and AIBN were impregnated in porous PTFE film and then, polymerized under 8$0^{\circ}C$ to give PS/PTFE membranes. Finally, the membranes were reacted with chlorosulfonic acid in 1,2-dichloroethane to give the sulfonated composite membranes. The measurements of ATR-FTIR, SEM, solvent uptake test and ion exchange capacity (IEC) were done for the resulting membranes before or after sulfonation, respectively, which showed the composite membranes with proper crosslinking degree and sulfonic acid content were prepared well as a function of styrene/DVB ratio. ion conductivity and methanol permeability were studied for the sulfonated membranes. It was found that with decreasing the ratio of styrene/DVB, methanol permeability decreased from $6.6{\times}10^{-7}∼1.3{\timas}10^{-7}$ $\textrm{cm}^2$/s, which are much lower values than that of Nafion$^{(R)}$117($1.02{\times}10^{-6}$ $\textrm{cm}^2$/s). Under the same monomer condition, ion conductivity decreased from 0.11 S/cm ($25^{\circ}C$) to 0.08 S/cm ($25^{\circ}C$), which are similar or a little higher values compared with $Nafion^{(R)}117 (1.02{\times}10^{-6}$ $\textrm{cm}^2$/s, 0.0824 S/cm). These two results confirmed the composite membranes prepared could be applied successfully to DMFC.C.

Study on Characterization of Galvanic Oxygen Sensor (갈바니식 산소센서의 특성에 관한 연구)

  • Cho, Dong-Hoe;Park, Myon-Yong;Lee, Byoung-Cho;Chung, Koo-Chun;Park, Jongman;Lee, Kyeong-Jae;Chung, Sung-Sook;Park, Sun-Young;Lee, Kwang-Woo
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.371-378
    • /
    • 1994
  • The detection range of this galvanic oxygen sensor for oxygen concentration was 0.0% to 20.0%. By using gold or silver as cathode, reproducible response time and sensitivity to change of oxygen concentration were observed. The anode was Pb-Sn-Ca alloy. Oxygen selective permeable membrane was hydrophobic and porous Teflon film. The effect of the membranes varying in thickness have been studied on the temperature($10{\sim}50^{\circ}C$) and relative humidity(R. H 0~99%). Lead acetate buffer solution as the electrolyte has shown a high output voltage and longer life.

  • PDF