• 제목/요약/키워드: Tedlar bag

검색결과 32건 처리시간 0.027초

Bio 필터를 이용한 Toluene 제거에서 미생물분해에 관한 연구 (A Study on Microbial Degradation for Removal of Toluene Vapour by Biofilter)

  • 하상안;강신묵
    • 환경위생공학
    • /
    • 제14권1호
    • /
    • pp.24-30
    • /
    • 1999
  • A biological filter for treatment of toluene among volatile organic compounds was studied. The investigation was conducted using specially built stainless steel columns packed with granular activated carbon and cold for removal of toluene. The G.A. and mold as filter material was also coated with Pseudomonas putida microorganisms.The biofilter unit was operated in the condition of moisture content vairation at gas loading rate of 12.5 l/min. Gaseous toluene taken from tedlar bag was analyzed by the use of G.C equipped with F.I.d detector. The removal efficiency of gaseous toluene was 95% at average inlet concentration of 950 ppm during bio-degradation operating condition. Effective removal efficiency was obtained with moisture content 27.5% at activated carbon and 32% at mold in this study. The effective operating condition were obtained with pH 6-8, temperature 28-42℃ for microbial degradation at gas loading rate of 12.5 l/min in packed material.

  • PDF

Bio필터를 이용한 VOC 가스 중 Toluene 제거율과 필터특성 연구 (A Study on Toluene Removal of VOC and Characteristics of Material Using Biofilter)

  • 강신묵;하상안
    • 환경위생공학
    • /
    • 제13권2호
    • /
    • pp.88-94
    • /
    • 1998
  • This study was investigated the application of biofiltration using cometabolic process to remediate gaseous toluene that are highly recalcitrant to adsorption, absorption and biodegradation. The investigation was conducted using specially built steel columns packed with granular activated carbon for removal of toluene and G.A.C was also coated with Pseudomonas putida microorganisms by addition of KH$_{2}$PO$_{4}$. The biofilter unit was operated in the condition of dry and 27.5% moisture content at gas loading rate of 12.5 l/min. Gaseous toluene taken from tedlar bag was analyzed by the use of G.C. equipped with F.I.D. detector. The removal efficiency of gaseous toluene was 85% at average inlet concentration of 970 ppm during dry operating condition. For gaseous toluene, 91% removal efficient was obtained at the filter material with moisture content and 97% removal efficiency was obtained with Pseudomonas putida microorganisms at gas loading rate of 12.5 l/min.

  • PDF

산적 액체 화물 작업중 배출되는 VOCs 분석방법 및 오염 측정 연구 (A study on the Analysis Method and Pollution Measure of existed VOCs during the Bulk Liquid Cargo Operation at Vessels)

  • 정광현;이인호
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2007년도 춘계학술발표회
    • /
    • pp.21-26
    • /
    • 2007
  • [ ${\ulcorner}$ ]1978년 의정서 및 1997년 의정서에 의하여 개정된 선박으로부터의 오염방지를 위한 1973년 국제협약${\lrcorner}$의 부속서 VI ${\ulcorner}$선박으로부터의 대기오염방지를 위한 규칙${\lrcorner}$이 발효 (2005.5.19) 함에 따라 동 내용의 수용을 위한 개정 (2005.12.29, 공포, 2006. 6.29. 시행)이 되었음에도 유중기배출제어장치의 설치가 되어있지 않았거나 설치되어 있어도 사용하지 않는 유류 터미널이 대부분이다. 본 연구의 목적은 다양하고 체계화되지 않은 VOCs 의 시료채취 및 분석방법을 고찰하고 산적 액체 위험물작업중에 배출되는 VOCs의 현 실태를 파악하여 VOCs 에 대한 보다 체계화된 접근을 시도해보고자 하였다. VOCs 에 대한 시료채취방법 중 Tedlar bag 은 화학반응 및 흡착현상에 의한 농도감소현상이, 용매추출을 이용한 방법은 추출시의 실험오차요인이, 흡착관은 흡착시 파과에 의한 오차요인이 분석의 신뢰도를 떨어뜨리는 원인으로 작용하고 있으며 Canister를 이용한 방법은 상기 방법의 단점을 보완한 가장 안정한 방법으로 파악된다. 선박에서 산적 액체 화물 작업중 배출된 유해성대기오염물질의 분석자료와 오염물질에 관한 VOCs 배출 연구분석자료는 충분하지 않다. 그러므로, 향후 선박 작업중에 배출되는 VOCs 관리에 대한 지속적인 Monitoring이 필요하다고 사료되며 선원들의 건강상 안전을 위해서라도 이 분야에 대한 연구가 활발히 진행되었으면 한다.

  • PDF

국내 수종별 BVOCs 방출량 (1) (Emission Rates of Biogenic Volatile Organic Compounds (BVOCs) from Various Tree Species in Korea (I))

  • 장한나;손정아;제선미;오창영;조민석;김주완;김재현;최원실;이영규
    • 한국산림과학회지
    • /
    • 제110권4호
    • /
    • pp.543-553
    • /
    • 2021
  • 피톤치드는 식물체에서 방출되는 생물유래 휘발성유기화합물(BVOCs)에 포함되어있는 isoprene, monoterpene, sesquiterpene과 같은 화합물들 형태로 존재한다. 또한 피톤치드는 중요한 산림치유 인자인 동시에 질소화합물과 광학반응을 하여 오존 및 이차 유기에어로졸 생성에 영향을 미치는 물질로 보고되고 있다. 본 연구에서는 우리나라 도시숲 주요 30 수종을 선정하여 표준환경조건(온도: 30℃, 광도: 1,000 μmol/m2/sec)에서 400 L Tedlar bag의 순환형 챔버를 이용하여 시료를 포집하여 열탈착-GC/MS로 분석하였고, 해당 수종의 잎을 건조시켜 건중량 당 수종별 isoprene 및 terpene류의 방출량을 분석하였다. Isoprene 방출량은 전체 수종 중에서 왕대에서 가장 높았으며 졸참나무, 굴거리나무, 회양목이 주요 isoprnen 방출 수종으로 나타났다. Monoterpene 방출량은 리기다소나무에서 가장 높았으며 고로쇠, 일본잎갈나무, 백목련, 메타세쿼이아, 잣나무, 소나무, 전나무가 주요 monpterpene 방출 수종으로 나타났다. Monotrerpene 주요 물질은 α-pinene, myrcene, limonene, β-pinen, sabinene이였으며, sesquiterpene의 주요 물질은 caryophyllene, farnesene으로 나타났다. Oxygenated monoterpene의 주요 물질은 pulegone, borneol, menthol, eucalyptol, nerol이였고 oxygenated sesquiterpene에서는 carypphyllene oxide가 주요 물질로 검출되었지만 30개 수종에서 sesquiterpene과 oxygenated sesquiterpene의 방출량은 상대적으로 낮았다.

국내 수종별 BVOCs 방출량(II): 도시 숲 주요 수종 (Emission Rates of Biogenic Volatile Organic Compounds from Various Tree Species in Korea (II): Major Species in Urban Forests)

  • 장한나;손정아;김주완;김준혁;김영성;최원실;이영규
    • 한국산림과학회지
    • /
    • 제111권4호
    • /
    • pp.490-501
    • /
    • 2022
  • 식물체에서 isoprene, monoterpene, sesquiterpene과 같은 화합물들 형태로 방출되는 피톤치드를 포함한 VOCs를 총칭하여 생물유래 휘발성유기화합물 BVOCs (biogenic volatile organic compounds)로 구분하고 있다. 피톤치드는 중요한 산림치유 인자인 동시에 질소화합물과 광학반응을 하여 오존 및 이차 유기에어로졸 생성에 영향을 미치는 물질로 보고되고 있다. 본 연구에서는 우리나라 도시숲 주요 32 수종을 선정하여 3년생 이하 묘목을 연구 대상으로 표준환경조건(온도: 30℃, 광도: 1,000 μmol/m2/sec)에서 400 L Tedlar bag을 순환형 챔버를 이용하여 도시숲 주요 수종에서 방출되는 기체시료를 포집하여 열탈착-GC/MS로 분석하였다. 해당 수종의 잎을 건조시켜 건중량 당 수종별 isoprene 및 terpene류 38종의 방출량을 분석하였다. Isoprene 방출량은 전체 수종 중에서 신갈나무에서 가장 높게 나타났으며 버드나무, 아까시나무, 왕버들이 주요 isoprene 방출 수종으로 분류되었다. Monoterpene 방출량은 스트로브잣나무가 가장 높았으며 참죽나무, 박태기나무가 주요 monoterpene 방출 수종으로 나타났다. Monoterpene 주요 물질은 α-pinene, myrcene, camphene, limonene이였으며, oxygenated monoterpene의 주요 물질은 eucalyptol이였다. Oxygenated sesquiterpene에서는 caryophyllene oxide가 주요 물질로 검출되었지만 32개 수종에서 sesquiterpene과 oxygenated sesquiterpene의 방출량은 상대적으로 낮았다.

소나무와 잣나무에서 배출되는 주요 테르펜의 배출특성에 관한 비교연구 (A Study on the Comparison to Source Profile of the Major Terpenes from Pine Tree and Korean Pine Tree)

  • 지동영;김소영;한진석
    • 한국대기환경학회지
    • /
    • 제18권6호
    • /
    • pp.515-525
    • /
    • 2002
  • A field study was conducted to estimate the emission rate of biogenic volatile organic compounds (BVOCs) from pine trees. In addition, the influences of meteological variables on their distribution characteristics have been investigated. A vegetation enclosure chamber was designed and constructed of Tedlar bag and acril. Sorbent tubes made up of Tenax TA and Carbotrap were used to collect biogenic VOCs emitted from each individual tree. Analysis of BVOCs was performed using a GC-FID system. The fundamental analytical parameters including linearity, retention time, recovery efficiency, and breakthrough volume were examined and verified for the determination of monoterpene emission rates. Total average concentration of each component is found to be $\alpha$-pinene (16.5), $\beta$-pinene (4.61) from pine trees, and $\alpha$-pinene (42.4), $\beta$-pinene (18.7 ng(gdw)$^{-1}$ hr$^{-1}$ ) from Korean pine trees. On the basis of our study, $\alpha$-pinene was found to be the major monoterpene emitted from both pine and Korean pine trees which were accompanied by $\beta$-pinene, camphene, and limonene. In ambient air, variable monoterpene compositions of emissions from pine trees were similar to Korean pine trees. Emission rates of monoterpene from each tree were found to depend on such parameters as temperature and solar radiation.

교통량특성과 거리에 따른 대기 오염물질 분포에 관한 연구(성남시의 $NO_{x}$, Co를 중심으로) (Distribution of $NO_{x}$ and CO among the Ambient air by traffic volume characteristics and distance from roadside (The Sungnam City Case))

  • 권우택;김형철
    • 환경위생공학
    • /
    • 제12권3호
    • /
    • pp.41-49
    • /
    • 1997
  • In South Korea since 1970s the rapid development of economic growth has brought about "Urbanization" in many areas and also raised the level of people's life in many ways. At the same time, however, the industrialization and overpopulated districts in many areas have caused the problems of air pollution in necessary. Among those air pollution, in particular, in large cities has become more serious since 1990s than before. Air pollution, like TSP and SO$_{x}$ caused by heating, generation of electric power and industrialization in 1980s, showed as that of the type of an underdeveloping country and was not hazardous enough to people in the least. Unfortunately, in 1990s NO$_{x}$, CO and O$_{3}$ caused by the soaring numbers of many types of cars have exhausted air pollutant more hazardous as the same air pollution type of many developed countries. So, the purpose of this study would be to analyze the changes of concentration of NO$_{x}$ and CO on environmental air by traffic volume and from the side drive way to the degree of distance in Sungnam City, and recognize the citizens' consciousness to air pollution and suggest the best walking point in part, and plan to design the reasonable use of cars and finally make the air quality improve toward the better-ment in part. From the research result we can know that people walking in the street would be protected from the hazardous air pollutant caused by the cats if they walk apart from a drive way as far as they can in the street. Accordingly, it might, to minimize th affect of air pollution, be thought to be desirable that the consideration of in introduction the system that the vehicle using the diesel engine motor should use the centered-lane aparted from road. Another to be desirable is that along side the road, the trees inhaled the pollution should be planted.

  • PDF

부산광역시 지하철역 지하공간의 대기오염 특성 (Analysis of air pollution in subway area of Busan Metropolitan City)

  • 이화운;장난심;곽진;이희령;김희만
    • 한국환경과학회지
    • /
    • 제11권3호
    • /
    • pp.169-176
    • /
    • 2002
  • The purpose of this study is designed to estimate the air quality of subway stations that have the underground platforms in Pusan Metropolitan City, from September to November 2000, over seven times. The subjects include Yonsan-dong station, Somyon station, Pusan station, Nampo-dong station, and Tushil station. The samplings were conducted at three points of each station, i.e. gate, ticket gates, and platforms. The major materials for analysis were CO, NO, NO$_2$, and $O_3$. The experiment was conducted at 7:00 pm with KIMOTO HS-seven Handy sampler and Tedlar Bag of SKC INC(U.S.A). In order to more fully understand station environments, we also measured temperature at each point. The results showed that $O_3$ average concentration at Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at ticket gate and platform at Somyon station(119 ppb, 122 ppb), Nampo-dong station(102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls was higher than others. At Somyon station having a junction station, NO and NO$_2$ concentration level of platform-2(noncrowded) was higher than platform-1(crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems.

자동차 배출가스 중 BTEX의 비율과 C2-benzenes의 상관성 연구 (A Study on the BTEX Ratio and Correlation of C2-benzenes in Vehicle Exhaust)

  • 문선희;정택호;정성운;김선문;서석준;이승환;김정화;홍유덕;홍희경
    • 한국분무공학회지
    • /
    • 제23권4호
    • /
    • pp.185-191
    • /
    • 2018
  • Benzene, toluene, ethylbenzene and xylene (BTEX) were well known as ozone precursors from photochemical reactions and contribute to the formation of photochemical smog which pose health hazards. Also, some of these compounds directly affect the human health due to their toxicity such as benzene. In this study, BTEX ratios and correlation of $C_2$-benzenes (xylenes, ethylbenzene) in vehicle exhaust from recreational vehicle (RV) and multi-purpose vehicle (MPV) were characterized using a chassis dynamometer. VOCs were collected by tedlar bag and a GC/MS system was used for their quantification. Among all of the BTEX, toluene has the highest concentration(more than 30% in composition of BTEX). The average ratio of toluene to benzene emissions (T/B ratio=2.2) was found in vehicle exhaust. The average m,p-xylene/ethylbenzene and m,p-xylene/o-xylene ratios were 1.0 and 3.0 respectively. As a result, it showed a good correlation between the $C_2$-benzenes ($R^2=0.98{\sim}0.99$). In the future, it can be used as a marker for effect evaluation to atmospheric environment by vehicle exhaust.

활성탄관법을 이용한 공기중 이황화탄소 농도 측정법에 관한 연구 (Evaluation of the Charcoal Tube Sampling Method for Carbon Disulfide in Air)

  • 이나루;백남원
    • 한국산업보건학회지
    • /
    • 제3권1호
    • /
    • pp.22-36
    • /
    • 1993
  • This study was conducted to evaluate the charcoal tube sampling method for carbon disulfide in the air. Breakthrough was investigated according to flow rate, sampling time and air volume. Also the storage stability by storage method and time was investigated. The results are summarized as follows. 1. The samples stored at room temperature($28.2^{\circ}C$), refrigerator($3.8^{\circ}C$) and freezer($-15.6^{\circ}C$) were analyzed every week to five weeks. At one week storage at room temperature, 3.5% of $CS_2$ in the front section of the charcoal tube migrated into the back section and 57.7% at five weeks. The amount of $CS_2$ in the back section of the charcoal increased continuously by storage time. Migration of $CS_2$ was slow at refrigerator, and stopped occur at freezer. Recovery rate $CS_2$ was 52-82% at room temperature and 92-101% at refrigerator, based on the amount at freezer as a reference value. Thus loss was observed at room temperature. 2. When 6-48 L of fresh air were passed through tubes with spiked amounts of 0.379 and 0.759mg sample, the amounts of $CS_2$ in the back section of charcoal were 5.7-132.4 and 0-92% of the amount in the front section, respectively. The total recovery rates of$CS_2$ from 0.379 and 0.759mg spiked sample were 35.7-101.0% and 9l.3-100.1%, respectively. $CS_2$ loss was observed in 0.379mg spiked sample, but not in 0.759mg spiked sample. In the spiked samples, the amount of $CS_2$ in the back section of charcoal was not affected by flow rate when the air volume was controlled. The amount of $CS_2$ in the back section of charcoal increased over sampling time. And the faster the flow rate, the more the migration amount when the sampling time was the same. 3. A known concentration, 10 ppm of $CS_2$, was produced in a 200 L Tedlar bag. When the air volume was 24, 36, 48 L, breakthrough was 5.8, 16.9, 47.4%, respectively. The sampling flow rate of 0.05, 0.1, 0.2 Lpm did not change the breakthrough rate. Breakthrough increased over sampling time. And the faster the flow rate, the more the breakthrough, when the sampling time was the same.

  • PDF