• Title/Summary/Keyword: Technology Value Assessment

Search Result 598, Processing Time 0.024 seconds

Thermoelectric Properties of ZnkIn2O3+k(k=1∼9) Homologous Oxides (Homologous 산화물 ZnkIn2O3+k(k=1∼9)의 열전 특성)

  • Nam, Yun-Sun;Choi, Joung-Kyu;Hong, Jeong-Oh;Lee, Young-Ho;Lee, Myung-Hyun;Seo, Won-Seon
    • Korean Journal of Materials Research
    • /
    • v.13 no.8
    • /
    • pp.543-549
    • /
    • 2003
  • In order to investigate the thermoelectric properties of $Zn_{k}$ $In_2$$O_{ 3+k}$ homologous compounds, the samples of $Zn_{k}$ /$In_2$$O_{3+k}$ / (k = integer between 1 and 9) were prepared by calcining the mixed powders of ZnO and $In_2$$O_3$fellowed by sintering at 1823 K for 2 hours in air, and their electrical conductivities and Seebeck coefficients were measured as a function of temperature in the range of 500 K to 1150 K. X-ray diffraction analysis of the sintered samples clarified that single-phase specimens were obtained for $Zn_{k} /$In_2$$O_{3+k}$ with k = 3, 4, 5, 7, 8, 9. Electrical conductivity of the $Zn_{k}$ $In_2$$O_{3+k}$ / decreased with increasing temperature, and decreased with increasing k for k $\geq$ 3. The Seebeck coefficient was negative at all the temperatures for all compositions, confirming that $Zn_{k}$ $In_2$$O_{3+k}$ / is an n-type semiconductor. Absolute values of the Seebeck coefficient increased linearly with increasing temperature and increased with increasing k for k $\geq$ 3. The temperature dependence of the Seebeck coefficient indicated that Z $n_{k}$I $n_2$ $O_{3+k}$ could be treated as an extrinsic degenerate semiconductor. Figure-of-merits of Z $n_{k}$I $n_2$ $O_{3+k}$ were evaluated from the measured electrical conductivity and Seebeck coefficient, and the reported thermal conductivity. Z $n_{7}$ I $n_2$ $O_{10}$ has the largest figure-of-merit over all the temperatures, and its highest value was $1.5{\times}$10$^{-4}$ $K^{-1}$ at 1145 K.5 K.

Management of small yellow croaker stock in Korean waters based on production value-per-recruit analysis (가입당 생산액 분석에 의한 한국 해역 참조기 Larimichthys polyactis 자원의 관리)

  • Zhang, Chang-Ik;Lee, Eun-Ji;Kang, Hee-Joong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.4
    • /
    • pp.467-475
    • /
    • 2014
  • This study was performed to estimate optimum fishing mortality (F) and the age at first capture ($t_c$) for small yellow croaker in Korean waters. We first estimated optimum F and $t_c$ using traditional yield-per-recruit (YPR) analysis, and the results were 0.8/year and 2.5 years old, respectively. However, the individual fish price per unit weight of small yellow croaker in Korea increases dramatically by size. Thus, we developed an alternative method, which is called as production value-per-recruit (PPR) analysis. We developed two types of the PPR analysis, that is, the discrete function and the continuous function method. We estimated optimum F and $t_c$ using the two types of the PPR analysis and compared the results. The optimum F and $t_c$ from the discrete function method, were 0.3/year and 5.0 years old, respectively, while those from the continuous function method were 0.5/year and 3.5 years old, respectively. These PPR estimates were much more conservative for the stock management than the traditional YPR analysis, which can prevent the fish stock from the economic overfishing. As a result, the PPR analysis could be more proper approach for stock assessment in the case that the individual fish price per unit weight increases dramatically by size like small yellow croaker in Korea.

Forest Degradation and Spatial Distribution of Forest Land Development (산지개발의 공간분포와 산림훼손)

  • Yu, Jaeshim;Choi, Wontae;Lee, Sanghyuk;Choi, Jaeyong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.19 no.6
    • /
    • pp.101-110
    • /
    • 2016
  • Development activities in forest areas are analysed based on degree of slope, altitude, land cover, and prefectures in order to improve the capacity of existing regulations of 'feasibility of forest land conversion' and 'assessment of forest land characteristics' in this research. 959 land based developments between year 2007 and 2013 have been analysed. A development site includes over 50% of forest is categorized as a forest type, degree of slope is steeper than $8.5^{\circ}$ as mountain type, and a development included in the both categories as combined type. Distribution characteristics of the above three types are analysed by development categories and regions adopting Relative Mountain Development Index(RMDI). In results, 44.94% of total development activities have been carried out in Gyeongsang Do in order of urban development, industrial complex, sports facilities, and soil and stone collection quarrying. Developments less than $0.3km^2$ which are exempt from the feasibility of forest land conversion regulation consist 86 cases of forest type, 78 cases in mountain type, and 78 cases in combined type. SAI by slope range showed the highest value of 1.55 in less than $5^{\circ}$ and the lowest value of 0.69 between $20^{\circ}-25^{\circ}$. RMDI value in Gyeongsang Do where mountain ratio is 67.05% appeared 1.17, which is 5 times more than Gangwon Do where mountain area ratio is 81.30%, and 2 times more than Chungchung Do where mountain area ratio is 51.24%. Development activities in forestland in Korea showed unequal distributions and 26% of those developments were not subjected to the feasibility of forest land conversion regulation.

Characteristics of Ultimate Load in a Wind Turbine for IEC 61400-1 DLC1.1 and DLC1.3 (IEC 61400-1 DLC1.1과 DLC1.3에 대한 풍력터빈의 극한하중 특성)

  • Kim, Chung-Ok;Nam, Hyun-Woo;Eum, Hark-Jin;Kim, Gui-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.15-24
    • /
    • 2012
  • IEC 61400-1 requires design lifetime of wind turbines at least 20 years, thus wind turbine should be assured for structural safety through load assessment. DLCs have been defined with respect to the load assessment in IEC 61400-1. In addition, if the extreme design values for DLC1.3 are equal or exceed the extreme design value for DLC1.1, DLC1.1 may be omitted. To omit DLC1.1, scale factor (c) will be increased in DLC1.3. However, this particular adjustment is not specified guidelines. Thus, this study was conducted. DLC1.1 was calculated for extrapolation of 50 years-extreme events using several probability distribution functions and fitting methods. And DLC1.3 was calculated for up to seven different values of scale factor (c) with $2{\leq}c{\leq}5$ in steps of 0.5. Finally, in this study, scale factor (c) that was the value of 4.51 was determined.

The Development of Korean Life Cycle Impact Assessment Index Based on a Damage Oriented Modeling (한국형 피해산정형 전과정 영향평가 지표 개발)

  • Park, Pil-Ju;Kim, Mann-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.499-508
    • /
    • 2010
  • This study proposed a life cycle impact assessment index that can indicate the environment-related information of the product in monetary value such that the national geographical, environmental, and social features are fully reflected based on a damage-oriented model. First, the estimation process was classified into characterization, damage assessment, and integration stages considering the six biggest impact categories: resource depletion, global warming, ozone depletion, acidification, eutrophication, and photochemical oxidant creation. Moreover, this study came up with the 16 category endpoints related to the 6 impact categories, and the damage function, to the 4 largest safeguard subjects. The integration indices of finally identified impact categories were KRW 21.8/kg Sb, KRW 6.19/kg$CO_2$, KRW 53,000/kg CFC-11, KRW 13,100/kg $SO_2$, KRW 2,310/kg ${PO_4}^{3-}$, and KRW 3,030/kg $C_2H_4$. Using the results of this research, environmental impacts based on the environmental load generated throughout the entire life cycle of a product can serve as a single index in monetary value; thus enhancing understanding and utilization of the results of life cycle impact assessments.

Study of the Floc Size Distribution for the Efficiency Assessment of Flocculation Process in Water Works (플럭크기를 이용한 응집공정 진단에 관한 연구)

  • Jung, Jin-Hong;Choi, Gye-Woon;Park, Jae-Roh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7438-7442
    • /
    • 2014
  • An assessment of flocculation was performed by measuring the distribution of the floc size during sedimentation in water works. The size and number of flocs have a greater effect on an evaluation of the efficiency of flocculation rather than the turbidity. The data was collected in situ using particle image velocimetry and image analysis. The measurements were carried out at a water depth of 1m. The removal efficiency of the total organic compounds, UV absorbance and turbidity depended on the size and floc size distribution in flocculation as the G value. The G value of 50 sec-1, 30 sec-1 and 10 sec-1 showed the highest degree of efficiency in the case of an inlet water turbidity of 5 NTU, and the highest degree of efficiency was observed at a G value of 65 sec-1, 40 sec-1 and 10 sec-1 when the inlet water turbidity was 263 NTU. The number of flocs with a distribution of above $1,200{\mu}m$ was 14. The dynamics between two important growth mechanisms were investigated as the energy input changed. This is a certain method that makes use of the size and number of flocs as an efficiency assessment.

Mathematical representation to assess the wind resource by three parameter Weibull distribution

  • Sukkiramathi, K.;Rajkumar, R.;Seshaiah, C.V.
    • Wind and Structures
    • /
    • v.31 no.5
    • /
    • pp.419-430
    • /
    • 2020
  • Weibull distribution is a conspicuous distribution known for its accuracy and its usage for wind energy analysis. The two and three parameter Weibull distributions are adopted in this study to fit wind speed data. The daily mean wind speed data of Ennore, Tamil Nadu, India has been used to validate the procedure. The parameters are estimated using maximum likelihood method, least square method and moment method. Four statistical tests namely Root mean square error, R2 test, Kolmogorov-Smirnov test and Anderson-Darling test are employed to inspect the fitness of Weibull probability density functions. The value of shape factor, scale factor, wind speed and wind power are determined at a height of 100m using extrapolation of numerical equations. Also, the value of capacity factor is calculated mathematically. This study provides a way to evaluate feasible locations for wind energy assessment, which can be used at any windy site throughout the world.

A Multi-attribute Index for Evaluating of National Nuclear R&D Projects: A Case Study of Korea (다속성 효용이론을 이용한 평가지표개발 - 원자력연구개발사업의 사후평가를 중심으로 -)

  • 곽승준;유승훈;김찬준
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2001.05a
    • /
    • pp.389-408
    • /
    • 2001
  • Evaluating the results of National Nuclear R&D projects has critical importance in nuclear management aspect. This paper uses multi-attribute utility theory as a basis for obtaining a value Index to assess the results of nuclear R&D projects and applies the theory to a specific Korean case study. To structure and quantify basic values for the . evaluation, we elicited important attributes, then refined and structured them into a hierarchy. A multi-attribute index is constructed as a multi-attribute utility function, based on value judgments provided by a group of technical experts, policy makers, and decision-makers. The implications of the results are also discussed. We found that the work and results can provide valuable insights for assessment of nuclear R&D consequences.

  • PDF

An Assessment of the Potential Area of Mountainous Wetland Using AHP (AHP를 이용한 산지습지 가능지역 평가)

  • Moon, Sang Kyun;Koo, Bonhak
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.1
    • /
    • pp.27-43
    • /
    • 2014
  • The purpose of this research is to assess potential area of mountainous wetland by GIS and AHP (Analytic Hierarchy Process). Mountainous wetland is topographically located at high altitude, so it's difficult to approach for researchers. And, it's difficult to investigate systematically because of the insufficient information of mountainous wetland. Therefore, it's necessary to study on potential area of mountainous wetland for systematic and efficient investigation. This research selected slope, wetting index, land-cover map and soil map as assessment items indicating environmental characteristics of mountainous wetland and established them by GIS DB. And, spatial value of mountainous wetland for each assessment item was drawn by existing investigation data and overlap analysis of mountainous wetland. Based on the numerical results of each assessment item, a survey was conducted and relative importance for each assessment item was decided by AHP. As the result, slope was the highest as 0.550 and ground coverage was the lowest as 0.083. The subject of this research was Yangsan-si and Ulsan of Gyeongnam and an analysis was conducted for mountainous wetland in those research areas. As the result, all of wetland was distributed in the range of potential area. And, field survey and literature search were conducted for the point that the distribution of mountainous wetland is expected. As the result, mountainous wetland was distributed. Therefore, mountainous wetland should be excavated through the results of this research and it should be helpful for effective investigation as providing information necessary to the following studies on mountainous wetland.

Radiological safety assessment of lead shielded spent resin treatment facility with the treatment capacity of 1 ton/day

  • Byun, Jaehoon;Choi, Woo Nyun;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.273-281
    • /
    • 2021
  • The radiological safety of the spent resin treatment facility with a14C treatment capacity of 1 ton/day was evaluated in terms of the external and internal exposure of worker according to operation scenario. In terms of external dose, the annual dose for close work for 1 h/day at a distance of more than 1 m (19.8 mSv) satisfied the annual dose limit. For 8 h of close work per day, the annual dose exceeded the dose limit. For remote work of 2000 h/year, the annual dose was 14.4 mSv. Lead shielding was considered to reduce exposure dose, and the highest annual dose during close work for 1 h/day corresponded to 6.75 mSv. For close work of 2000 h/year and lead thickness exceeding 1.5 cm, the highest value of annual dose was derived as 13.2 mSv. In terms of internal exposure, the initial year dose was estimated to be 1.14E+03 mSv when conservatively 100% of the nuclides were assumed to leak. The allowable outflow rate was derived as 7.77E-02% and 2.00E-01% for the average limit of 20 mSv and the maximum limit of 50 mSv, respectively, where the annual replacement of the worker was required for 50 mSv.