• 제목/요약/키워드: Technology Factor

검색결과 11,874건 처리시간 0.037초

Resonance Elastic Scattering and Interference Effects Treatments in Subgroup Method

  • Li, Yunzhao;He, Qingming;Cao, Liangzhi;Wu, Hongchun;Zu, Tiejun
    • Nuclear Engineering and Technology
    • /
    • 제48권2호
    • /
    • pp.339-350
    • /
    • 2016
  • Based on the resonance integral (RI) tables produced by the NJOY program, the conventional subgroup method usually ignores both the resonance elastic scattering and the resonance interference effects. In this paper, on one hand, to correct the resonance elastic scattering effect, RI tables are regenerated by using the Monte Carlo code, OpenMC, which employs the Doppler broadening rejection correction method for the resonance elastic scattering. On the other hand, a fast resonance interference factor method is proposed to efficiently handle the resonance interference effect. Encouraging conclusions have been indicated by the numerical results. (1) For a hot full power pressurized water reactor fuel pin-cell, an error of about +200 percent mille could be introduced by neglecting the resonance elastic scattering effect. By contrast, the approach employed in this paper can eliminate the error. (2) The fast resonance interference factor method possesses higher precision and higher efficiency than the conventional Bondarenko iteration method. Correspondingly, if the fast resonance interference factor method proposed in this paper is employed, the $k_{inf}$ can be improved by ~100 percent mille with a speedup of about 4.56.

The influence of magnetic field on the alignment of steel fiber in fresh cementitious composites

  • Li, Hui;Li, Lu;Li, Lin;Zhou, Jian;Mu, Ru;Xu, Mingfeng
    • Computers and Concrete
    • /
    • 제30권5호
    • /
    • pp.323-337
    • /
    • 2022
  • This paper proposes a numerical model to simulate the rotational behavior of steel fiber in fresh cement-based materials in the presence of a magnetic field. The results indicate that as the aspect ratio of fiber increases, the required minimum magnetic field intensity to make fiber rotate in viscous fluid increases. The optimal magnetic field intensity is 0.03 T for aligning steel fiber in fresh cement-based materials to ensure that the applying time of the magnetic field can be conducted concurrently with the vibrating process to increase the aligning efficiency. The orientation factor of steel fiber in cement mortar can exceed 0.85 after aligning by 0.03 T of the uniform magnetic field. When the initial angle of the fiber to the magnetic field direction is less than 10°, the magnetic field less than 0.03 T cannot make the fiber overcome the yield stress of fluid to rotate. The coarse aggregate in steel fiber-reinforced concrete is detrimental to the rotation and alignment of the steel fiber. But the orientation factor of ASFRC under the 0.03T of the magnetic field can also exceed 0.8, while the orientation factor of SFRC without magnetic field application is around 0.6.

Acute Toxicity Study of Recombinant Granulocyte-Macrophage Colony Stimulating Factor (LBD-005) in ICR mice

  • Kim, Hyoung-Chin;Song, Si-Whan;Cha, Shin-Woo;Shin, Chun-Chul;Ha, Chang-Su;Han, Sang-Seop
    • Biomolecules & Therapeutics
    • /
    • 제1권2호
    • /
    • pp.270-274
    • /
    • 1993
  • The acute toxicity of a recombinant granulocyte-macrophage colony stimulating factor (code name: LBD-005) was evaluated in both sexes of ICR mice, 5~6 weeks old, by the oral, subcutaneous and intravenous routes of administration. Based on the results of the acute toxicity study, LBD-005 was not considered to induce any toxic effect on the mice in mortalities, clinical findings, body weights and gross findings. It is suggested that $LD_50$ values in mice would be >48 mg/kg in the oral route and >24 mg/kg in the subcutaneous or intravenous route.

  • PDF

푸쉬풀 퀀텀 직렬공진형 정류기의 3레벨 예측형 역률개선 기법 (Three-Level Predictive Power Factor Correction Technique for Push-Pull Quantum Series Resonant Rectifier)

  • 문건우;백인철;정영석;이준영;;윤명중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.368-370
    • /
    • 1995
  • A new three-level push-pull type quantum series resonant rectifier for the power factor correction is proposed. The proposed single phase rectifier enables a zero-current switching operation of all the power devices allowing the circuit to operate at high switching frequencies and high power levels. With the proposed control technique, an unity power factor and greatly reduced line current harmonics can be obtained.

  • PDF

X선영상증배관의 상대변환계수 측정에 관한 검토 (The Study on Measurement of Relative Conversion Factor in X-ray Image Intensifier)

  • 김성철;신성일;이선숙;허준;김성수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.28-33
    • /
    • 1997
  • For the Evaluation of X-ray image intensifier, we measured radiation dose at input of I. I., brightness and fluorescence at output of I. I. by using X-ray exposure meter, optometer and fluorescence meter for the relative conversion factor. Especially, by using fluorescence meter, we could easily get relative conversion factor without having regulated machine by JIS. Since using, the quality of image intensifier is going down. Consequently, it needs continuous quality maintenance.

  • PDF

Bridgeless Buck PFC Rectifier with Improved Power Factor

  • Malekanehrad, Mahdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.323-331
    • /
    • 2018
  • Buck power factor correction (PFC) converters, compared with conventional boost PFC converters, exhibit high efficiency performance in the entire range of universal line voltage. This feature has gotten more attention for eliminating the zero crossing dead angle of buck PFC rectifiers. Furthermore, bridgeless structures for the reduction of conduction losses have been proposed. The aim of this paper is to introduce a single-phase buck rectifier that simultaneously has unity power factor (PF) and bridgeless structure while operating in the continuous conduction mode (CCM). For this purpose, two auxiliary flyback converters without any active switches are applied to a bridgeless buck rectifier to eliminate the zero crossing dead angle and achieve unity power factor, low total harmonic distortion (THD) and high efficiency. The operation and design considerations of the proposed rectifier are verified on a 150W, 48V prototype using a conventional peak-current-mode control. The measurement results show that the proposed rectifier has nearly unity power factor, THD less than 7% and high efficiency.

Single-Stage High-Power-Factor Electronic Ballast with a Symmetrical Class-DE Resonant Rectifier

  • Ekkaravarodome, Chainarin;Jirasereeamornkul, Kamon
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.429-438
    • /
    • 2012
  • This paper presents the use of a novel, single-stage high-power-factor electronic ballast with a symmetrical class-DE low-$d{\upsilon}$/$dt$ resonant rectifier as a power-factor corrector for fluorescent lamps. The power-factor correction is achieved by using a bridge rectifier to utilize the function of a symmetrical class-DE resonant rectifier. By employing this topology, the peak and ripple values of the input current are reduced, allowing for a reduced filter inductor volume of the EMI filter. Since the conduction angle of the bridge rectifier diode current was increased, a low-line current harmonic and a power factor near unity can be obtained. A prototype ballast, operating at an 84-kHz fixed frequency and a 220-$V_{rms}$, 50-Hz line input voltage, was utilized to drive a T8-36W fluorescent lamp. Experimental results are presented which verify the theoretical analysis.

유역인자 분석에서 DTED의 효용성 분석 (A Usefulness Analysis of DTED in the analysis of a watershed factor)

  • 양인태;천기선;박재훈
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.35-41
    • /
    • 1998
  • A watershed terrain factor is known to the very important in studies of a stream and a watershed. We have obtained the terrain factor in map directly or we have generated it in a digitalized map. In this study, DTED(Digital Terrain Elevation Data) offering in DMA(Defense Mapping Agency) was used to create a stream and a watershed and to extract the terrain factor. As comparison of the factors gererated in digitalized map the terrain factors extracted in DTED, DTED could be used to extract a terrain factor for a watershed management.

  • PDF

고역률을 갖는 단일 전력변환 AC-DC 컨버터 (Single Power-conversion AC-DC Converter with High Power Factor)

  • 조용원;박천윤;권봉환
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.23-30
    • /
    • 2014
  • This paper proposes a single power-conversion ac-dc converter with a dc-link capacitor-less and high power factor. The proposed converter is derived by integrating a full-bridge diode rectifier and a series-resonant active-clamp dc-dc converter. To obtain a high power factor without a power factor correction circuit, this paper proposes a suitable control algorithm for the proposed converter. The proposed converter provides single power-conversion by using the proposed control algorithm for both power factor correction and output control. Also, the active-clamp circuit clamps the surge voltage of switches and recycles the energy stored in the leakage inductance of the transformer. Moreover, it provides zero-voltage turn-on switching of the switches. Also, a series-resonant circuit of the output-voltage doubler removes the reverse-recovery problem of the output diodes. The proposed converter provides maximum power factor of 0.995 and maximum efficiency of 95.1% at the full-load. The operation principle of the converter is analyzed and verified. Experimental results for a 400W ac-dc converter at a constant switching frequency of 50kHz are obtained to show the performance of the proposed converter.

중소기업의 ERP 시스템 도입요인에 대한 중요도 분석 (The Importance Analysis on SME's ERP System Introduction Factors)

  • 오상권;이선규
    • 한국콘텐츠학회논문지
    • /
    • 제15권4호
    • /
    • pp.490-499
    • /
    • 2015
  • 본 연구에서는 선행연구에서 제시된 ERP시스템의 도입 요인들에 대해서 델파이 기법과 계층화 의사결정법(AHP)을 이용하여 각 도입 요인들에 대한 중요도를 분석하였다. 1차 계층의 도입 요인들에 대한 중요도를 분석한 결과 혁신요인, 정보기술요인, 사용자 요인, 공급사 요인 중 중요도가 가장 높은 요인은 공급사 요인으로 분석되었고, 1차 계층의 중요도를 고려한 2차 계층에 대한 가중치 분석에서는 공급사 요인의 표준업무 모델의 적합성 요인이었으며, 혁신요인의 최고경영층의 참여 요인(.086)이 2번째로 중요한 도입요인으로 분석되었다. 이러한 분석 결과는 국내 중소기업의 입장에서는 이미 개발된 ERP 시스템을 도입하여 운영을 하여야 하기 때문에 해당 기업의 특성이나 경영전략 등이 잘 적용된 시스템을 선정하여 도입하기를 희망하고 있는 것으로 판단할 수 있었으며, 이 과정에서 최고 경영자의 참여 역시 매우 중요한 요인임을 알 수 있었다.