Measurement of the Spatial Dose Rates During PET/CT Studies (전신 PET/CT 검사에서 공간선량률 측정)

  • Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.257-260
    • /
    • 2006
  • In order to evaluate the exposure to the radiologic technologists from patients who had been administrated with radiopharmaceuticals, we measured the spatial dose rates at $5{\sim}300\;cm$ from skin surface of patients using an proportional digital surveymeter, 1.5(PET scan) and 4hr(bone scan) after injection. In results, the exposure to the technologists in each procedure was small, compared with the dose limits of the medical workers. However, the dose-response relationships in cancer and hereditary effects, referred to as the stochastic effects, have been assumed linear and no threshold models ; therefore, the exposure should be minimized. For this purpose, the measurements of spatial dose rate distributions were thought to be useful.

  • PDF

The Influence of Air Cavity on Interface Doses for Photon Beams (X선치료 조사야 내 공동의 존재에 따른 선량분포의 측정)

  • Chung Se Young;Kim Young Bum;Kwon Young Ho;Kim You Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.69-77
    • /
    • 1998
  • When a high energy photon beam is used to treat lesions located in the upper respiratory air passages or in maxillary sinus, the beams often must traverse an air cavity before it reaches the lesion. Because of this traversal of air, it is not clear that the surface layers of the lesion forming the air-tumor tissue interface will be in a state of near electronic equilibrium; if they are not, underdosing of these layers could result. Although dose corrections at large distances beyond an air cavity are accountable by attenuation differences, perturbations at air-tissue interfaces are complex to measure or calculate. This problem has been investigated for 4MV and 10MV X-ray beams which are becoming widely available for radiotherapy with linear accelerator. Markus chamber was used for measurement with variouse air cavity geometries in X-ray beams. Underdosing effects occur at both the distal and proximal air cavity interface. The magnitude depended on geometry, energy, field sizes and distance from the air-tissue interfaces. As the cavity thickness increased, the central axis dose at the distal interface decreased. Increasing field size remedied the underdosing, as did the introduction of lateral walls. Fellowing a $20{\times}2{\times}2\;cm^3$\;air\;cavity,\;4{\times}4\;cm\;field\;there\;was\;an\;11.5\%\;and\;13\%\;underdose\;at\;the\;distal\;interface,\;while\;a\;20{\times}20{\times}2\;cm^3\;air\;cavity\;yielded\;a\;24\%\;and\;29\%$ loss for the 4MV and 10MV beams, respectively. The losses were slightly larger for the 10MV beams. The measurements reported here can be used to guide the development of new calculation models under non-equilibrium conditions. This situation is of clinical concern when lesions such as larynx and maxillary carcinoma beyond air cavities are irradiated.

  • PDF

The Evaluation about the Information Fidelity in the External Image Information Input - Using DICOM Validation Tool - (외부영상정보 입력 시 DICOM정보 충실성에 대한 평가 - DICOM Validation Tool 이용 -)

  • Lee, Song-Woo;Lee, Ho-Yeon;Do, Ji-Hoon;Jang, Hye-Won
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.33-38
    • /
    • 2011
  • Now a days, there's many change over for PACS among the most of hospital and it standard for DICOM 3.0. These kind of using of DICOM 3.0 improves increasing of medical imaging exchange and service for patient. However, there's some problems of compatibility caused during carry out CD and DVD from hospital. For this reason, this thesis analyzed patients image targeting those storages requested to hospitals in Seoul by using Validation Toolkit which is recommended from KFDA. The analyze type is like this. Make 100 data, total 500, each of MRI CT Plain x-ray Ultrasound PET-CT images and analyzed type of error occurred and loyalty of information. If express percentage of error occurred statistically, we can get a result as follows MRI 5%, Plain x-ray 11%, CT 18%, US 25%, PET-CT 30%. The reson why percentage of error occurred in PET-CT is because of imperfective support and we could notice that we weren't devoted to information. Even though, PET-CT showed highest percentage of error occurred, currently DICOM data improved a lot compare to past. Moreover, it should be devoted to rule of IHE TOOL or DICOM. In conclusion, we can help radiographer to analyze information of image by providing clues for solving primary problem and further more, each of PACS company or equipment company can enhance fidelity for following standard of image information through realizing the actual problem during transfer of image information.

  • PDF

Analysis of Medical Image with CD-RAD Phantom (CD-RAD Phantom을 이용한 의료영상의 분석)

  • Kim, Chang-Bok;Kim, Young-Keun;Cho, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.369-369
    • /
    • 2007
  • The physical and visual evaluation of the identical X-rays are analyzed for medical image clarity with CD-RAD Phantom on this study. The method of measurement is to research CD-RAD by X-rays and to acquire images through image processing equipment, the image analyses are carried out by physical evaluation with statistical method through CD-RAD analyser program, and the visual evaluation of the identical X-rays is carried out by blind test for 20 observers. The result of it is that IQF value of the physical evaluation of Contrast-detail curve is 25 and IQF value of the visual evaluation is 30, so it is revealed that the physical evaluation is superior to the visual one. The special qualities of medical images have much importance of the transmission capacity of information to the image analyser, so it is concluded that 0비ective methods of the physical and visual analyses should be carried out side by side.

  • PDF

Cross-Calibration of Domestic Devices and GE Lunar Prodigy Advance Dual-Energy X-Ray Densitometer Devices for Bone Mineral Measurements (국산 이중에너지 방사선흡수 골밀도 장치와 GE Lunar Prodigy의 교차분석 식 도출에 관한 연구)

  • Kim, Jung-Su;Rho, Young-Hoon;Lee, In-Ju;Kim, Kyoung-Ah;Lee, In-Ja;Kim, Jung-Min
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.27-31
    • /
    • 2017
  • Reliable follow-up of bone mineral density (BMD) by dual energy X-ray absorptiometry (DXA) is essential in clinical practice. When there is a difference in the BMD values from DXA systems in the same patient, cross calibration equation is required for the reliable follow-up. Unfortunately, no equation is existed in BMD measure between GE Lunar Prodigy Advance (US, GE Healthcare; LPA) and Osteosys Dexxum T (Korea, Osteosys; ODT) DXA systems. In this study, we evaluate the agreement of BMD values between LPA and ODT and suggest the cross calibration equation using European spine phantom (ESP) with two systems. We performed BMD measurements using ten scans with ESP in each DXA systems. We compared BMD values and calculated cross calibration equation by linear regression analysis. The comparison between the LPA and ODT bone densitometers used the ESP. Compared to the ESP BMD values, ODT underestimated 14.36% and LPA overestimated 12.96%. The average of total BMD measurement values acquired with ODT were 21.44% lower than those from LPA. Cross-calibration equation for LPA and ODT was derived from ESP. We calculated simple cross calibration equation for LPA and ODT DXA systems. Cross-calibration equation is necessary for the reliable follow-up of BMD values in two different systems.

A Study on the Measurement Linearity of Photoluminescent Dosimeter (형광유리선량계의 계측 직선성 연구)

  • Jeong, Kyeong-Hwan;Jung, Dong-Kyung;Seo, Jeong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.841-847
    • /
    • 2021
  • Related institutions that use radiation are diverse in Korea, such as research, medical care, and education. Recently, the number of examinations and visits to medical institutions is increasing. As a result, the number of radiological examinations in medical institutions is increasing. Radiation safety management is necessary as well as exposure of radiation workers. For safety management, first of all, it is necessary to wear the personal exposure dosimeter correctly and measure it accurately after wearing it. This study tries to evaluate and verify the measurement straightness of PLD devices by radiation of a diagnostic generator. Radiation division irradiation time interval was measured after irradiating 10 times at 10, 30, and 60 sec and irradiating the irradiation distance from 30 to 100 cm at 10 cm intervals to measure the change in absorbed dose depending on the distance. As a result, there was no difference in absorbed dose by time interval. This is considered to be helpful in various studies by using a diagnostic generator for the study of high absorbed dose.

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

A Comparison Analysis of CT Effective Dose and Image Quality according to Abdominal Diameter (복부직경에 따른 CT유효선량 및 화질변화 비교 분석)

  • Yoon, Joon;Kim, Hyeonju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.821-826
    • /
    • 2018
  • This study was performed randomly from all the patients who visited the University Hospital in Gyeonggi-do from January 1, 2018 to June 30, 2018 for the abdominal CT scan. We divided the patients into three groups and evaluated the extent of effective dose and image quality according to the area of the abdominal CT image. As a result, the effective dose was 7.34 mSv in the average area group, 8.39 mSv in the average area and 5.89 mSv in the average area. For the analysis of image quality, ROI was plotted in the same three regions according to the abdominal area. As a result, CT values were significantly different in the abdominal area classified into 3 groups (p <0.05). The results of this study can be used as a basic data for the development of a protocol that can be applied in actual clinical practice. It is thought that it can help to reduce the image quality and the radiation dose.

Evaluating the Effects of Inferiority Management Using a Group Counseling Program for University Students in Health Science (보건계열 대학생의 집단상담 프로그램을 활용한 열등감 관리의 효과 분석)

  • Lee, Myung Hwa;Park, Young Joon;Jang, Hyon Chol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.557-563
    • /
    • 2019
  • The objective of this study was to identify factors affecting the positive and negative responses of undergraduate students to inferiority by using a group counseling program to manage the inferiority of undergraduate students majoring in health science. This study sampled 30 undergraduate students attending the health science department of S University and divided them into a treatment group and a control group. The treatment group received an inferiority management group counseling program twice a week 120 minutes each from November 20, 2018, to January 2, 2019 eight sessions in total. The inferiority response criterion was applied before-treatment, after-treatment, and follow-up to verify the effectiveness of the program. The analysis results showed that the inferiority management group counseling program significantly decreased the negative response of undergraduate students to inferiority and significantly increased the positive response to inferiority. These results suggest that the inferiority management counseling program can lower the negative attitude and enhance the positive attitude toward the inferiority, which is caused by comparing themselves with their peers.

Usefulness of Application of Tube Voltage Changes to Reduce Patient Dose during Abdominal CT Follow up (반복적인 복부 컴퓨터단층촬영 시행 시 환자선량 감소를 위한 관전압 변화 적용의 유용성)

  • Yoon, Joon;Kim, HyeonJu
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.293-299
    • /
    • 2021
  • In order to reduce the irresistible radiation exposure of patients who perform periodic examinations using a CT among various scan parameters a method to reduce patient dose was investigated through changes in the tube voltage close to X-ray penetrating power. As a result of the experiment 100 kVp was applied instead of 120 kVp which is commonly used in clinical practice and CTDI decreased by about 41% during scan. In addition the degree of change in image quality was measured as 1046.1±3.7 HU for CT value and 71.4±7.9 for Pixel value and statistical analysis showed no significant difference (0.05