• Title/Summary/Keyword: Technical complication

Search Result 101, Processing Time 0.026 seconds

The impact of frenulum height on strains in maxillary denture bases

  • Cilingir, Altug;Bilhan, Hakan;Baysal, Gokhan;Sunbuloglu, Emin;Bozdag, Ergun
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.409-415
    • /
    • 2013
  • PURPOSE. The midline fracture of maxillary complete dentures is a frequently encountered complication. The purpose of this study was to assess the effect of frenulum height on midline strains of maxillary complete dentures. MATERIALS AND METHODS. A removable maxillary complete denture was fabricated and duplicated seven times. Four different labial frenulum heights were tested for stresses occurring on the palatal cameo surface. The strains were measured with strain gauges placed on 5 different locations and the stresses were calculated. To mimic occlusal forces bilaterally 100 N of load was applied from the premolar and molar region. RESULTS. A statistically significant association between the height of the labial frenulum and the calculated stresses and strains was shown (P<.05) predominantly on the midline and especially on the incisive papilla. The results showed that stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. CONCLUSION. Within the limitations of this in vitro study, it can be concluded that the stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. Surgical or mechanical precautions should be taken to prevent short-term failure of maxillary complete dentures due to stress concentration and low cycle fatigue tendency at the labial frenulum region.

Complication incidence of two implant systems up to six years: a comparison between internal and external connection implants

  • Chae, Sung-Wook;Kim, Young-Sung;Lee, Yong-Moo;Kim, Won-Kyung;Lee, Young-Kyoo;Kim, Su-Hwan
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: This study was conducted to compare the cumulative survival rates (CSRs) and the incidence of postloading complications (PLCs) between a bone-level internal connection system (ICS-BL) and an external connection system (ECS). Methods: The medical records of patients treated with either a ICS-BL or ECS between 2007 and 2010 at Asan Medical Center were reviewed. PLCs were divided into two categories: biological and technical. Biological complications included >4 mm of probing pocket depth, thread exposure in radiographs, and soft tissue complications, whereas technical complications included chipping of the veneering material, fracture of the implant, fracture of the crown, loosening or fracture of the abutment or screw, loss of retention, and loss of access hole filling material. CSRs were determined by a life-table analysis and compared using the log-rank chi-square test. The incidence of PLC was compared with the Pearson chi-squared test. Results: A total of 2,651 implants in 1,074 patients (1,167 ICS-BLs in 551 patients and 1,484 ECSs in 523 patients) were analyzed. The average observation periods were 3.4 years for the ICS-BLs and 3.1 years for the ECSs. The six-year CSR of all implants was 96.1% (94.9% for the ICS-BLs and 97.1% for the ECSs, P=0.619). Soft tissue complications were more frequent with the ECSs (P=0.005) and loosening or fracture of the abutment or screw occurred more frequently with the ICS-BLs (P<0.001). Conclusions: Within the limitations of this study, the ICS-BL was more prone to technical complications while the ECS was more vulnerable to biological complications.

Mitral and Aortic Valce Replacement with Patch Enlargement of Narrow Aortic Annulus (협소한 대동맥판윤의 첨포확대후 대동맥 및 승모판막 대치술 치험 1예)

  • 강면식
    • Journal of Chest Surgery
    • /
    • v.12 no.1
    • /
    • pp.56-60
    • /
    • 1979
  • Replacement of the aortic valve in a normal or large aortic root can be accomplished with ease and safety in most instances. The presence of a narrowed aortic annulus remains a problem in that the replaced smaller prosthetic valve has a significant resting pressure gradient across the orifice. This narrowing causes not only technical difficulties, but also increased mortality and post-op. complication. Therefore this problem deserves special attention. This report presents our experience with a case of a small aortic root caused by rheumatic heart disease [AI and MS]. This is the method of enlargement of the aortic annulus with a woven Dacron patch and replacement of a larger prosthetic aortic valve combined with mitral valve replacement.

  • PDF

Anal Extrusion of Distal V-P Shunt Catheter after Double Perforation of Large Intestine

  • Jang, Hyun-Dong;Kim, Min-Su;Lee, Nam-Hyuk;Kim, Seong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.232-234
    • /
    • 2007
  • We describe the extrusion of a ventriculoperitoneal shunt catheter from the anus after double perforation of the large bowel in a 3-year-old girl with hydrocephalus. She was admitted because the tip of the peritoneal catheter protruded 10 cm from the anus and clear cerebrospinal fluid dripped from the tip. Emergency laparotomy was performed. The distal peritoneal catheter perforated and penetrated the sigmoid colon and re-perforated into the rectal cavity. The distal peritoneal catheter was removed, the proximal catheter was exposed for external drainage, and intravenous broad-spectrum antibiotics were administered for 2 weeks. After control of infection, the shunt system was completely removed. Bowel perforation by a peritoneal catheter is a rare complication. Diagnosis is often difficult, delayed, and its incidence is likely underestimated. Most bowel perforation is the result of infection as opposed to technical errors.

Complex Discrete Systems Graph Simulation

  • Kadirova, Delovar;Kadirova, Aziza
    • Journal of Multimedia Information System
    • /
    • v.2 no.3
    • /
    • pp.263-274
    • /
    • 2015
  • The subject of this work is the complex discrete systems simulation special features with the aid of dynamic graph models. The proposed simulation technique allows to determine the ways for tasks solutions in terms of discrete systems analysis and synthesis of various complication: one-dimensional and multidimensional, steady and unstable, with the pulse elements abnormal operating mode and others. Often complex control systems analysis and synthesis task solutions, via classical approach comes out to be insolvent, because of the computational problems. The application of graph models allows to perform clear and strict characterization and computer procedures automation. The optimal controls synthesis algorithm presented in this paper, transferring the discrete system from target initial state to target final state within the minimum time, allows to consider the zero initial conditions systems, with the initial potential energy, with the control actions limitations and complex pulse elements operating mode.

Cerebral Venous Thrombosis Complicated by Hemorrhagic Infarction Secondary to Ventriculoperitoneal Shunting

  • Son, Won-Soo;Park, Jae-chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.4
    • /
    • pp.357-359
    • /
    • 2010
  • While a delayed intracerebral hemorrhage at the site of a ventricular catheter has occasionally been reported in literature, a delayed hemorrhage caused by venous infarction secondary to ventriculoperitoneal shunting has not been previously reported. In the present case, a 68-year-old woman underwent ventriculoperitoneal shunting through a frontal burr hole, and developed a hemorrhagic transformation of venous infarction on the second postoperative day. This massive venous infarction was caused by bipolar coagulation and occlusion of a large paramedian cortical vein in association with atresia of the rostral superior sagittal sinus. Thus, to eliminate the risk of postoperative venous infarction, technical precautions to avoid damaging surface vessels in a burr hole are required under loupe magnification in ventriculoperitoneal shunting.

Tracheal Reconstruction Using Femoro-Femoral Bypass -A Case Report- (우측 소매 전폐 적출술 후 발생한 기관 협착증의 체외 순환을 이용한 수술치험 1례)

  • 최필조
    • Journal of Chest Surgery
    • /
    • v.27 no.4
    • /
    • pp.324-327
    • /
    • 1994
  • Resection and reconstruction of distal trachea or carina have posed tremendous technical challenges for surgeons. Successful outcome depends on thorough preoperative evaluation, careful anesthetic management,strict attention of surgical technique and postoperative care. We report a successful case of revision of tracheal stenosis using femoro-femoral bypass on a 13~year-old boy. The patient complained severe dyspnea about I month following right sleeve pneumonectomy. Preoperative CT scan and intraoperative bronchoscopy showed pin-point tracheal stenosis at a tracheo-bronchial anastomosis site about 1.2cm in length.At operation the lesion was severely adhesed and the lumen was nearly obstructed. The stenotic segment was resected and direct end-to-end anastomosis was done under femoro-femoral bypass for adequate oxygenation. The patient was discharged at postop. 16 days without specific complications and has continued to do well.

  • PDF

Successful Surgical Treatment of Acute Mediastinitis after Central Catheter Insertion - One case report - (중심정맥관 삽관 후 발생한 급성 종격동염의 수술치료 - 1예 보고 -)

  • Lee, Jae-Ik;Choi, Pill-Jo;Yie, Kil-Soo
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.388-391
    • /
    • 2007
  • Subclavian catheter insertion is now widely used because of its technical feasibility and effectiveness, but some complications related to this procedure have been noted. We present here a rare surgical case of post central line insertion mediastinitis with no mechanical complication.

Posterior Thoracotomy under the Prone Position in Children - Report of 3 Cases - (소아에서 복와위하의 개흉술 3례 보고)

  • 김기봉
    • Journal of Chest Surgery
    • /
    • v.24 no.10
    • /
    • pp.1000-1004
    • /
    • 1991
  • Children`s small airway precludes the use of standard methods of bronchial separation. So, we performed the posterior thoracotomy under the prone position in 3 cases to avoid endobronchial gravity spillage of secretion and infected debris from the diseased lung to the contralateral sound lung. The advantages of the posterior thoracotomy under the prone position was discussed. In two cases, empyema with total collapse of left lung and congenital cystic adenomatoid malformation [CCAM] of right lung, copious secretion was spilled through the endotracheal tube but could be removed successfully by the endotracheal suction. In the third case of bilateral peripleural abscess, bilateral posterior thoractomy was done without position change. All procedures were performed without any technical difficulty and complication.

  • PDF

The Intrathecal Drug Administration System (척수강 내 약물 주입술)

  • Nahm, Francis Sahngun;Kim, Yong Chul
    • The Korean Journal of Pain
    • /
    • v.22 no.2
    • /
    • pp.117-123
    • /
    • 2009
  • The intrathecal drug administration system (ITDAS) has recently been introduced for treating chronic intractable pain patients who have failed with conservative pain treatments. The obvious advantages of its use are the direct intrathecal delivery of drugs, which yields reduced adverse effects and the increased strength of drugs, as compared to its oral or intravenous route. This article offers a review of the ITDAS with a brief review of its evidence-based effectiveness, the technical approach, and the complications.