• Title/Summary/Keyword: Technetium

Search Result 133, Processing Time 0.031 seconds

A Case of Cholethorax following Percutaneous Transhepatic Cholangioscopy (경피경간 담도내시경술 이후에 발병한 담즙흉 1예)

  • Park, Chan Sung;Lee, Soon Jung;Do, Gi Won;Oh, Ssang Yong;Cho, Hyun;Kim, Min Su;Hong, Il Ki;Bang, Sung Jo;Jegal, Yang Jin;Ahn, Jong-Joon;Seo, Kwang Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.2
    • /
    • pp.131-136
    • /
    • 2008
  • Cholethorax (bilious pleural effusion) is an extravasation of bile into the thoracic cavity via a pleurobiliary fistula (and also a bronchobiliary fistula). It is an extremely rare complication of thoraco-abdominal injuries. It can be caused by congenital anomaly and also by hepatobiliary trauma, severe infection or iatrogenic procedures. The definitive diagnosis is made with aspiration of bilious fluid from the pleural space during thoracentesis, by finding a fistulous tract during endoscopic retrograde cholangiopancreatography (ERCP) or cholagioscopy, or with finding an abnormal pleural accumulation of radioisotope during hepatobiliary nuclear imaging. Its symptoms include coughing, fever, dyspnea and pleuritc chest pain. Herein we report on a case of cholethorax following performance of percutaneous transhepatic cholangioscopy (PTCS) to remove incidentally discovered common bile duct (CBD) stones.

Giant Cell Tumor of the Proximal Fibula Treated by En Bloc Resection (전 절제술로 치료한 근위 비골의 거대 세포종)

  • Suh, Jeung-Tak;Choi, Sung-Jong;Kim, Young-Goun;Kim, Jeung-Il;Kim, Hui-Taek;Yoo, Chong-Il
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.200-205
    • /
    • 2003
  • Purpose: To report our experiences of clinical features, treatment method and results of giant cell tumor of 5 patients in proximal fibula. Materials and Methods: Five patients managed with an en bloc resection preserving common peroneal nerve and lateral collateral ligament reconstruction with biceps femoris tendon followed up between January 1997 and July 2001. Preoperative plain radiograph and MRI and bone scan were checked. The recurrence of the tumor was judged by plain radiograph and clinical signs. Lateral instability of knee joint was checked during the outpatient follow-up. Results: The mean age of the patients at the time of operation was twenty- three (21-29). There were one male and four female patients. Dull pain was main symptom and palpable mass was seen in two patients. Peroneal nerve palsy and local recurrence were not observed except one case of temporary peroneal nerve palsy. During the outpatient follow up, one among 5 patients showed slight lateral instability and the other 4 patients showed no instabililty. Conclusion: Giant cell tumor in proximal fibula managed with an en bloc resection preserving common peroneal nerve and lateral collateral ligament reconstruction with biceps femoris tendon showed favorable results.

  • PDF

Influence of Iodinated Contrast Media and Paramagnetic Contrast Media on Changes in Uptake Counts of 99mTc

  • Cho, Jae-Hwan;Lee, Jin-Hyeok;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Jin;Moon, Deog-Hwan;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to figure out how uptake counts of technetium ($^{99m}Tc$) among radioisotopes in the human body are affected if computed tomography (CT), magnetic resonance imaging (MRI) and isotope examination are performed consecutively. $^{99m}Tc$ isotope material, iodinated contrast media for CT and paramagnetic contrast media for magnetic resonance (MR) were used as experimental materials. First, $^{99m}Tc$ was added to 4 cc normal saline in a test tube. Then, 2 cc of CT contrast media such as $Iopamidol^{(R)}$ and $Dotarem^{(R)}$ were diluted with 2 cc normal saline, and 2cc of MRI contrast media such as $Primovist^{(R)}$ and $Gadovist^{(R)}$ were diluted with 2 cc normal saline. Each distributed contrast media was a total of 4 cc and included 10m Ci of $^{99m}Tc$. A gamma camera, a LEHR (Low energy high resolution) collimator and a pin-hole collimator were used for image acquisition. Image acquisition was repeated a total of 6 times and 120 frames were obtained and uptake counts of $^{99m}Tc$ were measured (from this procedure). In this study, as a result of measuring the uptake counts of $^{99m}Tc$ using the LEHR collimator, the uptake counts were less measured in all contrast media than normal saline as a reference. In particular, the lowest uptake counts were measured when $Gadovist^{(R)}$, contrast media for MRI, was used. However, the result of measuring the uptake counts of $^{99m}Tc$ using the pin-hole collimator showed higher uptake counts in all contrast media, except for $Iopamidol^{(R)}$, than normal saline as a reference. The highest uptake counts were measured particularly when $Primovist^{(R)}$, contrast media for MRI, was used. In performing the gamma camera examination using contrast media and $^{99m}Tc$, it is considered significant to check the changes in the uptake counts to improve various diagnosis values.

Scintigraphic Evaluation of Dogs with Experimentally Transected Cranial Cruciate Ligaments Treated Using Tibial Plateau Leveling Osteotomy (실험적으로 전십자 인대를 단열한 개에서 TPLO의 핵의학적 평가)

  • Lee Jae yeong;Kim Joong-hyun;Lee Won guk;Kang Seong soo;Bae Chun sik;Choi Seok hwa
    • Journal of Veterinary Clinics
    • /
    • v.22 no.1
    • /
    • pp.21-25
    • /
    • 2005
  • This study was performed to assess therapeutic effect of the tibial plateau leveling osteotomy (TPLO) in dogs with experimentally transected cranial cruciate ligaments (CrCL). Nine healthy adult Beagle dogs were transected left CrCL under general anesthesia. The dogs were assigned to TPLO and non-TPLO control groups. The TPLO procedures for correcting the CrCL rupture in the left stifle of dogs were performed under sterile conditions. Before TPLO procedures, all dogs were screened by orthopedic and radiographic examinations. Dogs were lameness free for the previous three months, and when examined at the walk and trot on a hard surface, in a straight line and on a circle. Lateral and craniocaudal radiographs were done to confirm the soundness of the both knee joint in dogs and not detectable lesions were diagnosed. The dogs were intravenously injected with a 10 mci/kg of 99mTechnetium-methylene diphosphonate (99mTc-MDP) under general anesthesia. Scintigraphs were obtained using a large field of view gamma camera equipped a parallel-hole, low-energy about 3 hours after intravenous injection of 99mTc-MDP. Before CrCL transection and 4, 8, and 12 weeks after the procedures, scintigraphy were conducted. Bone uptake of the left stifle joint increased after the procedures in all dogs. When the bone uptake from the TPLO procedure was compared with that of the control, there was a significant difference (p < 0.05). At 12 weeks after the TPLO procedure, the dogs showed normal anatomical posture and gait. It is concluded that TPLO procedure was effective in reconstruct of the stifle joint in dogs with CrCL rupture.

Myocardial Perfusion SPECT as a Screening Test before Planned Vascular Surgery for Predicting Perioperative Cardiac Complications (혈관 수술 후 심장 합병증 발생을 예측하기 위한 선별 검사로서 심근 관류 단일 광자 단층촬영의 유용성에 대한 연구)

  • Lee, Hyung-Chae;Hwang, Youn-Ho;Wi, Jin-Hong;Jun, Hee Jae;Lee, Yang-Haeng;Cho, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Background: Patients with vascular diseases commonly have coronary artery disease and associated cardiac problems. Therefore, their underlying heart diseases may be induced or exacerbated after vascular surgery. The effectiveness of SPECT imaging, which is a relatively simple and non-invasive imaging modality, for assessing these underlying heart diseases is still controversial. This study was performed to evaluate the clinical effect of tests and treatment based on SPECT imaging prior to vascular surgery on the development of post-operation cardiac complications. Material and Method: Sixty three patients who were treated at Inje University Pusan Paik Hospital between April 2004 and September 2007 and who underwent adenosine infusion technetium-99m (Tc-99m) tetrofosmin SPECT imaging prior to vascular surgery were selected for this study and we retrospectively reviewed their records. Result: The sensitivity and specificity of detecting a perfusion defect on SPECT to predict the development of cardiac complications was relatively low at 41.2% and 52.2%, respectively. However when coronary angiographies were done on the patients with abnormal SPECT and this was followed by aggressive treatment such as coronary artery intervention and coronary artery bypass grafting based on the angiography results, there was a tendency for lower cardiac complication rates. Conclusion: SPECT imaging shows low effectiveness as a screening test for predicting cardiac complications after vascular surgery.

Inflammation Scan Using $^{99m}Tc-HMPAO$ Labelled Leukocytes ($^{99m}Tc-HMPAO$를 이용한 자가백혈구표지 및 그를 이용한 염증병소의 스캔)

  • Yang, Woo-Jin;Chung, Soo-Kyo;Shinn, Kyung-Sub;Bahk, Yong-Whee;Kim, Hoon-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.219-223
    • /
    • 1989
  • Inflammation scan using radiolabelled leukocytes has high sensitivity and specificity. Several methods for labelling leukocytes have been evaluated using P-32 diisopropyl fluorophosphate (DFP-32), H-3 thymidine, Cr-51 chromate, Ga-67 citrate and Tc-99m-sulfur colloid. In-111-oxine has proved so far to be the most reliable agent for labelling leukocytes. In-111-oxine is, however, expensive, not easily available when needed, and its radiation dose to leukocytes is relatively high. Moreover, resolution of the resultant image is relatively poor. Tc-99m is still the agent of choice because of, as compared with the indium, its favorable physical characteristics, lower cost and availability. Now the technique for labelling the leukocytes with technetium is successfully obtained using the lipophilic HAPAO with higher efficiency for granulocytes than for other cells. With this technique it is possible to label leukocytes in plasma to improve the viability of the leukocytes. Inflammation scan using Tc-99m-HMPAO has been evaluated in several laboratories, and difference in methods for separation and labelling accounts for difference in efficiency, viability and biodistribution of the labelled leukocytes. We performed inflammation scan using leukocytes labelled with Tc-99m-HMPAO in three dogs 24 hours after inoculation of live E. Coli and A. Aureus in their right abdominal wall. We separated mixed leukocytes by simple sedimentation using 6% hetastarch (HES) and labelled the leukocytes with Tc-99m-HMPAO in 20% cell free plama diluted with phosphate buffer solution(Fig. 1). Uptake was high in the liver and spleen but is was minimal in the lungs on whole body scan. Kidneys and intestine showed minimal activity although it was high in the urinary bladder(Fig. 2). Uptake of labelled leukocytes in the inflammation site was do(mite on 2 hour-postinjection scan and abscess was clearly delineated on 24 hour-delayed scan with high target-to-nontarget ratio(Fig. 3, 4). Inflammation scan using mixed leukocytes labelled with Tc-99m-HMPAO is very sensitive and specific in early detection of inflammation.

  • PDF

Comparison of Stress-rest and Rest-stress One Day Myocardial Perfusion Scintigraphies in Detecting Coronary Artery Diseases (부하-휴식과 휴식-부하 1일 심근관류영상법의 관동맥질환 진단율 비교)

  • Bom, Hee-Seung;Min, Jung-Jun;Song, Ho-Cheon;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.30-35
    • /
    • 1997
  • It has been shown that both rest and stress myocardial perfusion imagings with technetium agents can be performed on the same day using two different doses injected within few hours. The purpose of this study was to compare the two protocols (stress-rest and rest-stress) in detecting coronary artery diseases. One hundred and sixty patients (101 males, 59 females, mean age $57{\pm}9$ years) and 120 patients (79 males, 41 females, mean age $59{\pm}10$ years) underwent stress-rest myocardial perfusion SPECT and rest-stress myocardial perfusion SPECT, respectively. All of them underwent both myocardial perfusion SPECT and coronary angiography within 1 month. A coronary stenosis was considered significant when it compromised the luminal diameter by ${\geq} 50%$. The chi square test was used to compare differences in sensitivity, specificity and accuracy between the two groups. The overall sensitivity, specificity and accuracy of stress-rest protocol were 99%, 35% and 68%, respectively. Those of rest-stress protocol were 96%, 47% and 78%, respectively. There was no difference between the two protocols in identifying individual diseased coronary artery branches. Therefore, one day stress-rest and rest-stress myocardial SPECT using $^{99m}Tc$ agents were comparable and were very sensitive tests in detecting coronary artery diseases.

  • PDF

Scintigraphic Features of Choledochal Cyst Using Technetium-99m-DISIDA Hepatobiliary Scan (총담관낭종의 $^{99m}Tc$-DISIDA 간담도 스캔)

  • Choi, Chung-Il;Kim, Jeong-Gyun;Bae, Sun-Kun;Kwak, Dong-Suk;Chung, Byung-Cheon;Lee, Jae-Tae;Lee, Kyu-Bo;Zeon, Seok-Kil;Lee, Hyung-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.71-80
    • /
    • 1993
  • In order to evaluate the scintigraphic features of choledochal cyst and these diagnostic value, authors investigated the findings of fourteen patients with choledochal cyst undergone hepatobiliary scan with $^{99m}Tc$-DISIDA before surgery. Five cases demonstrated the decreased hepatic uptake at 5-minute image of which four cases revealed severe jaundice. Seven cases demonstrated visualization of the cystic dilated common bile duct within 1 hour after injection. Two cases showed the cyst activity between 1 and 12 hours, but the cyst activity was not visible in five cases. Nonvisualization of the gall bladder was noted in ten cases, while four cases demonstrated visualization of the gall bladder within 1 hour. The time of visualization of gut activity was variably delayed. The intestinal activity was found in three cases within 1 hour and appeared in three cases between 1 and 2 hours and eight cases showed no visible gut activity. In four cases, intrahepatic ductal prominence was visible on the scintigram. Seven cases showed early and persistent accumulation of tracer in the common bile duct. Three cases showed persistent photon-deficient area in the gall bladder region. Two cases showed early photon-deficient area around gall bladder region with progressive accumulation of tracer in the same region. Two cases showed no evidence of activity in the biliary tract but noted late excretion into the small intestine. We concluded that hepatobiliary scan using $^{99m}Tc$-DISIDA is a noninvasive test useful in the evaluation and the diagnosis of choledochal cyst.

  • PDF

A Study about Effects of Osmotic-Controlled Release Oral Delivery System Methylphenidate on Regional Cerebral Blood Flow in Korean Children with Attention-Deficit Hyperactivity Disorder (주의력결핍 과잉행동장애 아동에서 Osmotic-Controlled Release Oral Delivery System Methylphenidate 투여가 국소 대뇌관류에 미치는 영향)

  • Yang, Young-Hui;Hwang, Jun-Won;Kim, Boong-Nyun;Kang, Hyejin;Lee, Jae-Sung;Lee, Dong-Soo;Cho, Soo-Churl
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.27 no.1
    • /
    • pp.64-71
    • /
    • 2016
  • Objectives: The objective of this study was to examine the effects of osmotic-controlled release oral delivery system methylphenidate on changes in regional cerebral blood flow (rCBF) in children with attention-deficit hyperactivity disorder (ADHD) using single photon emission computed tomography (SPECT). Methods: A total of 26 children with ADHD (21 boys, mean age: $9.2{\pm}2.05$ years old) were recruited. Each ADHD participant was examined for changes in rCBF using technetium-99m-hexamethylpropylene amine oxime brain SPECT before and after 8 weeks methylphenidate medication. Brain SPECT images of pediatric normal controls were selected retrospectively. SPECT images of ADHD children taken before medication were compared with those of pediatric normal controls and those taken after medication using statistical parametric mapping analysis on a voxel-wise basis. Results: Before methylphenidate medication, significantly decreased rCBF in the cerebellum and increased rCBF in the right precuneus, left anterior cingulate, right postcentral gyrus, right inferior parietal lobule and right precentral gyrus were observed in ADHD children compared to pediatric normal controls (p-value<.0005, uncorrected). After medication, we observed significant hypoperfusion in the left thalamus and left cerebellum compared to pediatric normal controls (p-value<.0005, uncorrected). In the comparison between before medication and after medication, there was significant hyperperfusion in the superior frontal gyrus and middle frontal gyrus and significant hypoperfusion in the right insula, right caudate, right middle frontal gyrus, left subcallosal gyrus, left claustrum, and left superior temporal gyrus after methylphenidate medication (p-value<.0005, uncorrected). Conclusion: This study supports dysfunctions of fronto-striatal structures and cerebellum in ADHD. We suggest that methylphenidate may have some effects on the frontal lobe, parietal lobe, and cerebellum in children with ADHD.

Comparison with $^{99m}Tc$ MDP Bone Scintigraphy and Whole body $^{18}FDG$ PET for the Evaluation of Bone metastases in Patients with Lung Cancer (폐암의 골전이에서 $^{99m}Tc$ MDP 골주사와 전신 $^{18}FDG$ PET의 비교)

  • Chung, Jae Ho;Park, Moo Suk;Hahn, Chang Hoon;Moon, Jin Wook;Kim, Young Sam;Kim, Se Kyu;Chang, Joon;Lee, Jong Doo;Kim, Sung Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.3
    • /
    • pp.280-286
    • /
    • 2003
  • Background : $^{99m}Technetium$ methylene diphosphonates($^{99m}Tc$ MDP) bone scintigraphy is current method of choice for the detection of bone metastases, but whole body $^{18}F$-fluoro-deoxy-D-glucose positron emission tomography($^{18}FDG$ PET) offers superior spatial resolution and improved sensitivity. So we compared whole body $^{18}FDG$ PET with $^{99m}Tc$ MDP bone scintigraphy in patients with skeletal metastases from lung cancer. Patients and Methods : Ninety-two patients with lung cancer taken $^{18}FDG$ PET together with a $^{99m}Tc$ MDP bone scintigraphy within 1 month between March 2000 and March 2003 were investigated retrospectively. Results : The sensitivity, specificity and accuracy of the $^{99m}Tc$ MDP bone scintigraphy versus $^{18}FDG$ PET for the detection of bone metastases in lung cancers were 59% vs 82%, 71% vs 94%, and 68% vs 91%, respectively. In the diagnosis of bone metastases from lung cancer, $^{18}FDG$ PET was statistically superior to $^{99m}Tc$ MDP bone scintigraphy in its specificity and accuracy(p<0.0001). Conclusions : Whole body $^{18}FDG$ PET may be useful in detecting bone metastases among patients with lung cancer.