• Title/Summary/Keyword: Tear film

Search Result 60, Processing Time 0.032 seconds

The Effect of Artificial Tear Components on Tear Film Stability of Dry Eyes in the Early Stage of Soft Contact Lenses Wear (소프트콘택트렌즈를 착용한 건성안의 착용초기 눈물막 안정성에 인공눈물 성분 조성이 미치는 영향)

  • Kim, So Ra;Lim, Jung A;Jung, Ji Hye;Byun, Hyun Young;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.191-201
    • /
    • 2016
  • Purpose: In the present study, the effect of artificial tears with different ingredients on tear film stability and subjective symptoms of dry eyes in the early stage of soft contact lenses wear was investigated. Methods: The three kinds of artificial tears and saline solution were respectively applied onto 50 dry eyes which wore soft contact lenses made of etafilcon A. Then, non-invasive tear film break-up time (NIBUT) was measured at every five minutes for 30 minutes right after the instillation of artificial tears, and the changes in blink rate and subjective symptoms were estimated after 30 minutes from the instillations. Results: All three kinds of artificial tears increased NIBUT larger than saline. The effect of increasing NIBUT immediately after the instillation of artificial tears was the largest when the artificial tear containing viscosity enhancer was used. The duration time of the effect was the longest when the artificial tear having both surfactant and viscosity enhancer was applied. The blink rate was not significantly changed when both artificial tears and saline solution were instilled. Subjective symptoms were significantly improved by the instillation of both artificial tears and saline solution and dryness, irritation, tiredness, stiffness, dazzling were improved by the use of most solutions. However, the subjective symptoms were rebounded to the level before the instillation of artificial tears after 30 minute-instillation. Conclusions: It was revealed that both artificial tears and saline solution could improve the subjective symptoms of dry eye in the early stage of soft contac lenses however, the effect of these solutions on the tear film stability was different according to the components. From the results, it is suggested that the proper selection of artificial tears is necessary for the improvement of dry eye symptoms at the early stage of soft contact lenses wear in dry eye.

Change in Axial Rotation of Toric Soft Contact Lens according to Tear Volume (눈물양에 따른 토릭 소프트콘택트렌즈의 축 회전양 변화)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.445-454
    • /
    • 2015
  • Purpose: The present study was aimed to investigate the effect of tear volume on a change of axial rotation according to wearing time of toric soft contact lens and gaze directions. Method: Toric soft contact lenses with double thin zone design applied on 62 eyes. Then, changes in non invasive tear film break-up time and the rotational direction/amount of lens when changing gaze direction were respectively measured after 15 minutes and 6 hours of lens wear. Results: Lens rotation to temporal direction was more found when changing gaze direction after lens wear. However, its rotation was varied according to wearing time and the subjects' tear volume. Furthermore, the frequency of lens rotation to temporal direction was higher in dry eyes compared with normal eyes at nearly all gaze directions after 15 minutes and 6 hour of lens wear. The rotational amount of lens was generally greater in dry eyes after 15 minutes of lens wear. However, its difference between normal eyes and dry eyes was not great after 6 hours of lens wear. Conclusion: The present study revealed that axial rotation of toric soft contact lens was varied according to the wearer's tear volume and lens rotational patterns at the initial, and extending periods of lens wear were different. The change in rotational pattern of toric soft contact lens from these results means the possibility of visual change after extending lens wear, and the identification of its correlation with tear volume suggests the necessity of considering factors for choosing appropriate toric soft contact lens.

Association of serum 25-hydroxyvitamin D concentrations with Schirmer tear test 1 and tear film breakup time in dogs

  • Youngsam Kim;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.2
    • /
    • pp.32.1-32.10
    • /
    • 2023
  • Background: The association between vitamin D and canine keratoconjunctivitis sicca (KCS) has not been investigated in dogs. Objectives: To investigate the association of serum 25-hydroxyvitamin D [25(OH)D] concentrations with Schirmer tear test 1 (STT-1) and tear film breakup time (TFBUT) in dogs. Methods: Sixty-one clinically healthy, client-owned dogs were enrolled. STT-1 and TFBUT were measured in 122 (61dogs) and 82 (41 dogs out of total 61 dogs) eyes, respectively. Serum 25(OH)D concentrations were evaluated by quantitative chemiluminescent immunoassay. The dogs were classified into 6 groups according to the evaluations (STT-1: group 1, normal [≥ 15 mm/min] in both eyes; group 2, normal in one eye and abnormal [< 15 mm/min] in the fellow eye; group 3, abnormal in both eyes; TFBUT: group 4, normal [≥ 20 sec] in both eyes; group 5, normal in one eye and abnormal [< 20 sec] in the fellow eye; group 6, abnormal in both eyes). Results: STT-1 was positively correlated with TFBUT (p < 0.001). Among the STT-1 groups, the mean serum 25(OH)D concentration in group 1 was significantly higher than in groups 2 and 3 with positive correlation (p < 0.001). However, there were no significant differences among the TFBUT groups 4, 5, and 6. Conclusions: In dogs, it was found that serum 25(OH)D concentrations had a greater effect on quantitative KCS than qualitative KCS. Therefore, it is considered that measurement of serum 25(OH)D concentration could be included in the diagnostic tests in canine quantitative KCS patients.

The Study of tear film stability for normal eyes in adults (성인 정상안의 눈물 안정성에 대한 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Sim, Sang-Hyun;Choi, Sun-Mi;Oh, Seung-Jin
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.4
    • /
    • pp.85-91
    • /
    • 2016
  • This study is to research the tear film stability for 48 eyes, agreed the purpose of study, didn't have no contact lens wearing and were tested all two times in a day. Their visual acuity was more than 0.8, corrective visual acuity more than 0.8, the fattest K-reading, apical corneal radius, was in 7.40~8.40mm, corneal astigment was less than 1.00D and orthophoria. The tests, tear scope test, tear film break up time test(TBUT) and schirmer test order, were performed their functions before and after their working at interval of 6 hours over. The tearscope test results was no difference, TBUT was no difference, although 1.2 seconds more in the afternoon, shcirmer test was decreased 2.0mm in the afternoon.

Comparison Among the Four Examination Methods for Dry Eye (OQAS test, TBUT, Schirmer Test, McMonnies test) (4가지 건성안 분석방법(OQAS test, TBUT, Schirmer test, McMonnies test)의 비교)

  • Park, Chang Won;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.519-526
    • /
    • 2015
  • Purpose: To evaluate the changes of OSI value according to tear-film instability measured serially by OQAS(Optical Quality Analysis System, Visiometrics, Spain) every seconds. The presented study analyzed the relationship of the OQAS parameter with the results of the tear-film break-up time, Schirmer test, and the McMonies score. Methods: 147 eyes of 82 subjects were randomly selected from university students (age: $21.51{\pm}3.97$, male 45, female 37). Subjects were measured tear-film break-up time, Schirmer test, McMonies score and once every second for 15 seconds after blinking by continuous measurements from OQAS system. Results: The normal eye groups presented OSI values of $2.13{\pm}1.16$ while the dry eye groups had OSI values of $3.76{\pm}1.42$. Therefore, a significant difference between the normal eye group and dry eye group was discovered (p<0.05). In addition, the OSI value of all subjects increased over time. The OSI value, which was measured every second after blinking occurred, significantly increased between 6 seconds and 7 seconds after the start of the measurement (p<0.05). OSI cut off of 30% (sec.) showed a greater correlation; TBUT (r = 0.855, p = 0.000), McMonies test (r = -0.351, p = 0.003), Schirmer (r = 0.316, p = 0.012). Conclusions: Continuous measurement of OQAS showed a high correlation with the value of the existing dry eye tests. Therefore, Analysis of OSI values by utilization of OQAS could be useful in objectively evaluation of tear film in patients.

Reference values for selected dry eye tests in normal Beagle dogs: a pilot study

  • Kim, Youngsam;Kang, Seonmi;Kim, Sunhyo;Shim, Jaeho;Go, Seokmin;Seo, Kangmoon
    • Journal of Veterinary Science
    • /
    • v.23 no.1
    • /
    • pp.10.1-10.12
    • /
    • 2022
  • Background: Dry eye disease (DED) cannot be diagnosed by a single test because it is a multifactorial disorder of the ocular surface. Although studies on various dry eye tests (DETs) in dogs have been reported, standard criteria have not been established except for the Schirmer tear test 1 (STT-1). Objectives: To establish reference values for DETs in dogs with normal STT-1 values (≥ 15 mm/min) and to analyze the correlation between DETs. Methods: The STT-1 was performed in 10 healthy Beagle dogs (20 eyes). After 20 min, interferometry (IF) for estimating the lipid layer thickness (LLT) of the tear film, tear meniscus height (TMH), non-invasive tear breakup time (NIBUT), and meibomian gland loss rate of the upper eyelid (MGLRU) and lower eyelid (MGLRL), were measured using an ocular surface analyzer. Results: Mean values for STT-1, TMH, and NIBUT were as follows: 21.7 ± 3.4 mm/min, 0.41 ± 0.21 mm, and 19.1 ± 9.5 sec, respectively. The most frequent LLT range, measured by IF, was 30-80 nm (11 eyes), followed by 80 nm (5 eyes) and 80-140 nm (4 eyes). MGLRU ≤ 25% was measured in 11 eyes and 26%-50% in 9 eyes; MGLRL ≤ 25% in 8 eyes and 26%-50% in 12 eyes. Besides positive correlation between TMH and NIBUT (P = 0.038), there were no significant associations between DETs. Conclusions: Data obtained in this study provided normative references that could be useful for diagnosing DED and for further research into correlation between DETs in dogs with DED.

Physical Properties of Chitosan Film made from Crab Shell (꽃게 껍질에서 분리제조한 키틴산 필름의 물성에 관한 연구)

  • Cho, Jeong-Suk;Han, Jeong-Jun;Lee, Cherl-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.574-580
    • /
    • 1992
  • Chitin was isolated from the residue of enzymatically hydrolyzed crab, Portunus trituberculatus, and further deacetylated by alkaline boiling to make chitosan. The physical properties of chitosan solution and its film forming properties were examined. The functional characteristics of chitosan film were compared to those of cellophane, polyvinyl chloride (PVC) and polyethylene (PE) films. The proximate chemical composition of chitin obtained from crab residue was 6.95% nitrogen, 0.3% crude ash and 4.57% moisture and the product yield was 12.8% based on a dry material basis. The degree of deacetylation of chitosan was $79{\sim}92%$ and $70{\sim}86%$ as determined by IR spectroscopy, and $70{\sim}86%$ as determined by colloid titration method each respectively. The chitosan at 1% acetic acid solution showed distinct pseudoplastic flow behavior. The flow behavior index and consistency index were 0.8886, 0.2084 $MPa{\cdot}s^n$ for 0.4% solution and 0.8498, 0.6190 $MPa{\cdot}s^n$ for 0.8% solution, respectively. The chitosan film had the highest tensile strength $(888 kg/cm^2)$ and water permeability $(100\;g/m^2{\cdot}24\;hrs)$ among the tested films, but relatively low elongation property (49%). It showed the similar tear strength (90kg/cm) and light permeability (87.7%) to other films tested in spite of the relatively high haze value (12.5%). As the thickness of chitosan film increased from 0.025 to 0.050 mm, the tensile strength of film decreased distictively, and the degree of elongation, tear strength, and water permeability of film also decreased slightly. Whereas the light permeability of film did not change and the haziness of film slightly increased by the increase of film thickness.

  • PDF

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.

The Box-office Success Factors of Films Utilizing Big Data-Focus on Laugh and Tear of Film Factors (빅데이터를 활용한 영화 흥행 분석 -천만 영화의 웃음과 눈물 요소를 중심으로)

  • Hwang, Young-mee;Park, Jin-tae;Moon, Il-young;Kim, Kwang-sun;Kwon, Oh-young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.6
    • /
    • pp.1087-1095
    • /
    • 2016
  • The study aims to analyze factors of box office utilizing big data. The film industry has been increasing in the scale, but the discussion on analysis and prediction of box-office hit has not secured reliability because of failing in including all relevant data. 13 films have sold 10 million tickets until the present in Korea. The study demonstrated laughs and tears as an main interior factors of box-office hit films which showed more than 10 milling tickets power. First, the study collected terms relevant to laugh and tear. Next, it schematizes how frequently laugh and tear factors could be found along the 5-film-stage (exposition - Rising action - crisis - climax - ending) and revealed box-office hit films by genre. The results of the analysis would contribute to the construction of comprehensive database for the box office predictions on future scenarios.

Effects of Humidity Changes on Eyes (습도 변화가 눈에 미치는 영향)

  • Sun-Hee Han;Bong-Hwan Kim;So-Bin Kim;Min-Jung Kim;Hee-Kyung Park;Hyun-Ji Kim;Heon-Tae Kim;Hyeong-Su Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1616-1624
    • /
    • 2023
  • Purpose. The purpose of this study was to investigate the effect of changes in tear break-up time, accommodative response amount, and accommodative microwave on the eyes due to changes in humidity. Methods. A total of 48 adult men and women in their 20s (21.1±1.56 years old) were surveyed on dry eye questionnaires (OSID questionnaires), tear destruction time was measured by humidity (40%, 60%, 80%), and controlled reactions and controlled fine waves were measured through tactile tests. Result. As a result of the OSID questionnaire, there were 10 normal patients, 8 mild dry eyes, 1 moderate dry eye, and 5 severe dry eyes. The initial tear film destruction time was 7.34±4.67 seconds at 40% humidity, 8.99±4.75 seconds at 60% humidity, 10.26±4.52 seconds at 80% humidity, and the average tear film destruction time was 9.51±4.07 seconds at 40% humidity, 10.99±3.82 seconds at 60% humidity, and 12.05±3.42 seconds at 80% humidity. The accommodative response was -0.41~1.79D at 40% humidity, -0.34~1.79D at 60% humidity, and -0.30~2.01D at 80% humidity. The accommodative microwave was measured as 56.39~63.43dB when it was 40%, 56.41~62.64dB when it was 60%, and 55.96 ~61.13dB when it was 80%. Conclusion. As the humidity (40~80%) increased, the tear break-up time increased, and as the accommodative stimulus amount increased, the accommodative response amount increased. It was found that the accommodative microwave according to the amount of accommodative stimulation increased, and as the humidity increased, the accommodative microwave decreased.