• Title/Summary/Keyword: Tc-To method

Search Result 1,079, Processing Time 0.032 seconds

In silico approach to calculate the transcript capacity

  • Lee, Young-Sup;Won, Kyung-Hye;Oh, Jae-Don;Shin, Donghyun
    • Genomics & Informatics
    • /
    • v.17 no.3
    • /
    • pp.31.1-31.7
    • /
    • 2019
  • We sought the novel concept, transcript capacity (TC) and analyzed TC. Our approach to estimate TC was through an in silico method. TC refers to the capacity that a transcript exerts in a cell as enzyme or protein function after translation. We used the genome-wide association study (GWAS) beta effect and transcription level in RNA-sequencing to estimate TC. The trait was body fat percent and the transcript reads were obtained from the human protein atlas. The assumption was that the GWAS beta effect is the gene's effect and TC was related to the corresponding gene effect and transcript reads. Further, we surveyed gene ontology (GO) in the highest TC and the lowest TC genes. The most frequent GOs with the highest TC were neuronal-related and cell projection organization related. The most frequent GOs with the lowest TC were wound-healing related and embryo development related. We expect that our analysis contributes to estimating TC in the diverse species and playing a benevolent role to the new bioinformatic analysis.

Development of Polymeric Drugs Utilizing Dithiocarbamate Chitosan: Formation and Antimicrobial Activities of Dithiocarbamate Chitosan-Ca(II)-Tetracycline Complex (Dithiocarbamate Chitosan을 Matrix로 이용한 고분자 약물의 개발 : Dithiocarbamate Chitosan-Ca(II)-Tetracycline Complex 의 생성 및 항균성)

  • 김윤택;김영미;한석규;정연진;유종호
    • YAKHAK HOEJI
    • /
    • v.39 no.1
    • /
    • pp.48-54
    • /
    • 1995
  • Coupling of tetracycline(Tc) to dithiocarbamate chitosan(DTCC) via chelate bond was investigated varying reaction time, concentration, temperature, pH, and Ca(II)/Tc ratio. The amount of Tc bound to matrix increased to give a maximum and decreased as the reaction proceeded. The degree and rate of dissociation of Tc complex were affected by the reaction temperature, and pH. By running the reaction at low temperature and pH, the degree of dissociation was greatly diminished. Properties of drug-release from DTCC-Ca(II)-Tc complex were studied by batch- and flow-method and release of Tc and CA(II) by flow method followed nearly zero-order. DTCC-Ca(II)-Tc showed very prolonged antimicrobial activity compared to that of free Tc.

  • PDF

Development of Polymeric Drugs Utilizing Dithiocarbamate Chitosan: Formation and Antimicrobial Activities of Dithiocarbamate Chitosan-Mg(II)-Tetracycline Complex (디치오카바메이트 키토산을 지지체로 이용한 고분자 약물의 개발 : 디치오카바메이트 키토산-Mg(II)-테트라사이클린 복합체의 생성 및 항균성)

  • 김윤택;유종호;정연진;이정수;김영미
    • YAKHAK HOEJI
    • /
    • v.39 no.4
    • /
    • pp.373-379
    • /
    • 1995
  • Coupling of tetracycline (Tc) to dithiocarbamate chitosan(DTCC) via chelate bond was carried out in the presence of Mg (II) ion by one- and two-bath process. In one-bath process, DTCC was treated with Mg(II)-Tc solution. In two-bath process, DTCC was treated with Mg(II) to produce DTCCMg(II), which was isolated and treated in turn with Tc solution. The effect of pH and temperature on binding of Tc, was investigated varying the pH of the solution from 2.6 to 3.2 at 10 and $30^{\circ}C$. Binding of Tc was not affected greatly by such variations in pH and temperature. Amount of Tc bound to 1 gm of matrix reached to 180 mg. Release of Tc from DTCC-Mg(II)-Tc was investigated by batch and flow method, and the amount of Tc released against time followed by flow method exhibited near linear relationship. DTCC-Mg(II)-Tc showed very prolonged antimicrobial activity compared to that of free Tc when it was tested against Escherichia coli TG-1 and Bacillus subtilis NA-1.

  • PDF

Safety-Economic Decision Making Model of Tropical Cyclone Avoidance Routing on Oceans

  • Liu, Da-Gang;Wang, De-Qiang;Wu, Zhao-Lin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.10a
    • /
    • pp.144-153
    • /
    • 2006
  • In order to take TC forecasts from different observatories into consideration, and make quantitative assessment and analysis for avoiding TC routes from the view of safety and cost, a new safe-economic decision making method of TC avoidance routing on ocean was put forward. This model is based on combining forecast of TC trace based on neural networks, technical method to determine the future TC wind and wave fields, technical method of fuzzy information optimization, risk analysis theory, and meteorological-economic decision making theory. It has applied to the simulation of MV Tianlihai's shipping on ocean. The result shows that the model can select the optimum plan from 7 plans, the selected plan is in accordance with the one selected by experienced captains.

  • PDF

A Convenient Method on the Methyl-Ethyl-Ketone Extraction of $^{99m}TcO^-{_4}$ ($^{99m}TcO^-{_4}$의 메틸-에틸-케톤-간편 추출법)

  • Lee, Jong-Du;Lee, Byung-Hyn
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.103-111
    • /
    • 1984
  • A convenient method of $^{99m}Tc$-methyl-ethyl-ketone (MEK) extraction technique was developed and a mobile $^{99m}Tc$-extraction generator was designed. The MEK extraction and the phase separation of $^{99m}TcO^-{_4}$ were carried out with a simple procedure in the same container. The shielding of $^{99}Mo$ radioactivity was made with one lead container. The system was simplified by shielding $^{99m}TcO_4{^-}({\gamma}_e=0.14\;MeV)$ separately. $^{99m}TcO^-{_4}\;in\;^{99m}Tc-MEK$ extract was recovered by adsorption and elution only, and therefore, the possibility of volatilization was reduced. The volume of $^{99m}TcO^{-}{_4}$-saline product was reduced to 1 ml by using a small alumina column and the column operation time was shortened. The separation time of $^{99m}Tc$ was reduced to 30 minutes, and the operation was carried out at the outside of the shielding. The system was designed to operate under the condition of bacteria-free.

  • PDF

Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges (마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리)

  • Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.430-438
    • /
    • 1999
  • Purpose: We evaluated a rapid preparation procedures for the labeling and quality control of $^{99m}Tc$-ECD, $MAG_3$, and MIBI using microwave heating and Sep-Pak cartridges. Materials and Methods: $^{99m}Tc$ labeling of ECD, $MAG_3$, and MIBI kit preparation was performed according to the package inserts with microwave heating modification. Heating time was 10-15 sec, and heating was performed with 3 mm plastic bottle with screw cap to prevent radiation contamination. Labeling efficiency was obtained with $C_{18}$ or Alumina N Sep-Pak cartridges. Results: The radiochemical purity of $93{\sim}96%$ for $^{99m}Tc$-ECD and $95{\sim}99%$ for $^{99m}Tc$-MIBI was obtained using Alumina N Sep-Pak cartridge. The optimum irradiation time of microwave method for 3 ml $^{99m}Tc$-labeled radiopharmaceutical solution was 10 sec for $^{99m}Tc$-ECD and $^{99m}Tc$-MIBI, and 15 sec for $^{99m}Tc-MAG_3$. The results of quality control data with Sep-Pak cartridges were well correlated with TLC method. The total preparation time of these radiopharmcaeuticals was $5{\sim}6min$ including quality control procedure. Conclusion: This study demonstrates that radiopharmaceuticals preparation by microwave heating and quality control by Sep-Pak cartridges can be efficiently utilized as an alternative to the recommended method by manufacturer's manual.

  • PDF

Analysis of Labelling Efficiency According to Differences of Rotating Time in a Asan Medical Center (AMC) RBC Labelling Method (서울아산병원의 적혈구 표지 방법에서 교반 시간 차이에 따른 표지 효율의 분석)

  • Chung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Shim, Dong-Oh;Lee, Yeong-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.90-93
    • /
    • 2010
  • Purpose: In our nuclear medicine department, we suggested AMC RBC labeling method improved by modifying a part of existing modified in-vitro method to raise the efficiency of $^{99m}Tc$-RBC labeling. However, it needs to be more additional time and efforts than existing modified in-vitro method because the AMC RBC labeling method has to carry out the centrifugal separation process for 3~5 minutes. Therefore, in this study, we conducted researches to aim to maintain stable labeling effects and supplement a problem about additional time by reducing rotating time when labeling $^{99m}Tc$-RBC. Materials and Methods: This research has been conducted the object of 30 patients who examined study using $^{99m}Tc$-RBC and agreed to this research at our hospital from May 2009 to September 2009. We made 4 blood samples which consisted of ACD 1 cc along with 5 cc blood from each patient and used the AMC RBC labeling method. At this moment, each labeling efficiency was calculated by different rotating time 5 min, 10 min, 15 min, and 20 min and then we compared differences. Results: As a result, When comparing the $^{99m}Tc$-RBC labeling method efficiency by using the AMC RBC labeling method which differents from rotating time, each labeling efficiency were $92.3{\pm}5.0%$ in 5 min, $95.9{\pm}5.0%$ in 10 min, $97.4{\pm}4.9%$ in 15 min and $97.7{\pm}4.8%$ in 20 min. We analyzed differences of the labeling efficiency from change of rotating time by using an one-way ANOVA and verified that in Duncan method. There was relatively efficiency low in 5min rotating time and no statistically significant change in over. Conclusions: When comparing a existing method, the AMC RBC labeling method which goes through the centrifugal separation process again offers more favorable condition to combine RBC with $^{99m}TcO4^-$ by eliminating an plasma ingredient. When using the modified in-vitro method, we have almost 20 min to rotate to acquire stable labeling efficiency. But, when using the AMC RBC labeling method, we acquire labeling efficiency well what we want within only 10 min to rotate. Decrease of rotating time can complement the AMC RBC labeling method which goes through the centrifugal separation process again and also provide more rapid study such as G-I bleeding study due to fast labeling.

  • PDF

Analysis of $^{99}Tc$ and Its Activity Level in the Korean Soil (한국 토양의 $^{99}Tc$ 분석 및 방사능 농도 준위)

  • Lee, Chang-Woo;Chung, Kun-Ho;Cho, Young-Hyun;Kang, Mun-Ja;Lee, Wan-No;Kim, Hee-Reyoung;Choi, Geun-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • An analytical method of $^{99}Tc$ concentration in soil was set up and discussed considering the $^{99}Tc$ concentration in Korean soil measured with its analytical method. A selective TEVA resin was used to separate and purify the $^{99}Tc$ in the soil sample. $^{99m}Tc$ from a commercial $^{99}Mo/^{99m}Tc$ generator was used as a yield tracer for the chemical separation of $^{99}Tc$ and its problem when using $^{99m}Tc$ as a tracer was discussed. The chemical recovery yield of $^{99}Tc$ was above 70%. The optimum conditions of inductively coupled plasma mass spectrometry system(ICP-MS) were set up to determine the $^{99}Tc$ after the separation process. The minimum detectable activity(MDA) was 15 mBq/kg-dry in this analytical procedure. The $^{99}Tc$ concentration in soils of Jeju and Kori were measured in the rage of 33.73-89.16 mBq/kg-dry. Those values were less than those reported in other countries and seemed to be originated from atmospheric fallout.

  • PDF

Comparative Studies on Detecting Methods of Fecal Indicators (Coliforms) in Surface Water (지표수에서의 분변오염지표세균 (대장균군) 검출방법의 비교연구)

  • Park, Ji-Eun;Kim, Sun-Duck;Cho, Ju-Rae;Kim, Sang-Hyun;Lee, Hae-Jin;Lee, Young-Ok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1052-1059
    • /
    • 2006
  • For monitoring the fecal pollution at Nak-Dong River, one of the eutrophicated rivers, the differences between total coliforms (TC) and fecal coliforms (FC) using both of membrane filtration (MF)/MPN method, and also fecal streptococcus (FS) by MF-method was investigated. To evaluate the correlation between TC, FC, and FS statistical analyses were performed by using Minitab. And a part of the presumptive TC/FC and background colonies was purified and identified using API 20E kit (Biomeriux). As results, most (89%) of presumptive FC by MF was identified as Escherichia coli while only 14% (MPN) and 11% (MF) of TC were identified as E. coli. Furthermore, FC by MF was correlated significantly with other fecal indicators (TC/FS by MF and FC by MPN), while TC by MPN was not correlated with any other indicators. Thus, the detection of FC by MF-method may be the most reasonable for monitoring the fecal pollution.

A study on the eddy current losses on the high-Tc superconducting power cable system

  • Song M.K.;Lee S.J.;Jang H.M.;Sim K.D.;Cho J.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.4
    • /
    • pp.32-36
    • /
    • 2005
  • The structure of a high-Tc superconducting power cable system is composed of these parts; (from the outer section) a liquid nitrogen cryostat, a vacuum cryostat, multi-layer high-Tc superconducting cable cores and a stabilizer and both cryostats during the stable operating period of the high-Tc superconducting power cable system are calculated by the numerical method. And the optimal conditions of the stabilizer and both cryostats, that minimize the eddy current losses, are derived from the analyzed results. The optimal results can be applied to the design and manufacture of the high-Tc superconducting power cable system.