Abstract

Purpose: We evaluated a rapid preparation procedures for the labeling and quality control of $^{99m}Tc$-ECD, $MAG_3$, and MIBI using microwave heating and Sep-Pak cartridges. Materials and Methods: $^{99m}Tc$ labeling of ECD, $MAG_3$, and MIBI kit preparation was performed according to the package inserts with microwave heating modification. Heating time was 10-15 sec, and heating was performed with 3 mm plastic bottle with screw cap to prevent radiation contamination. Labeling efficiency was obtained with $C_{18}$ or Alumina N Sep-Pak cartridges. Results: The radiochemical purity of $93{\sim}96%$ for $^{99m}Tc$-ECD and $95{\sim}99%$ for $^{99m}Tc$-MIBI was obtained using Alumina N Sep-Pak cartridge. The optimum irradiation time of microwave method for 3 ml $^{99m}Tc$-labeled radiopharmaceutical solution was 10 sec for $^{99m}Tc$-ECD and $^{99m}Tc$-MIBI, and 15 sec for $^{99m}Tc-MAG_3$. The results of quality control data with Sep-Pak cartridges were well correlated with TLC method. The total preparation time of these radiopharmcaeuticals was $5{\sim}6min$ including quality control procedure. Conclusion: This study demonstrates that radiopharmaceuticals preparation by microwave heating and quality control by Sep-Pak cartridges can be efficiently utilized as an alternative to the recommended method by manufacturer's manual.

목적: 마이크로웨이브를 이용한 방사성 동위원소의 표지와 Sep-Pak 카트리지를 이용한 정도관리 방법의 개선으로 신속한 제조가 가능하면서도 높은 표지효율을 가진 방사성 의약품을 얻고자 하였다. 대상 및 방법: $C_{18}$ 그리고 alumina N Sep-Pak카트리지를 이용한 정도관리 방법을 $^{99m}Tc$-ECD, $^{99m}Tc$-MIBI, $^{99m}Tc-MAG_3$에 적용하였고 표지효율을 측정하였다. 마이크로웨이브를 사용하여 상기의 키트에 방사성 동위원소를 표지하여 표지효율을 비교하였다. 결과: 마이크로웨이브에 의해 생성된 세 가지방사성 의약품은 3 ml용액에 $^{99m}Tc$-ECD와 $^{99m}Tc$-MIBI는 10초, $^{99m}Tc-MAG_3$는 15초의 짧은 마이크로웨이브를 조사하여 모두 95% 이상의 표지효율을 나타내었다. $^{99m}Tc$-ECD와 $^{99m}Tc$-MIBI는 Sep-Pak alumina N 카트리지를 사용하여 짧은 시간 내에서도 정확한 정도관리 결과를 얻을 수 있었다. 방사성 의약품의 제조시간은 정도관리를 포함하여 모두 6분 이하를 나타내었다. 결론: Sep-Pak 카트리지를 이용한 정도관리 방법과 마이크로웨이브에 의한 방사성 의약품의 제조 방법은 일상적인 방사성 의약품의 제조에 적용이 가능하였으며, 방사성 의약품의 제조시간을 크게 단축시킬 수 있었다.