• Title/Summary/Keyword: Tc-99m DTPA

Search Result 100, Processing Time 0.034 seconds

Determination of Appropriate Sampling Frequency and Time of Multiple Blood Sampling Dual Exponential Method with $^{99m}Tc$-DTPA for Calculating GFR (사구체여과율 계산을 위한 $^{99m}Tc$-DTPA를 이용한 다중 채혈 이중지수법의 적정 채혈 횟수 및 시간의 선정)

  • Kim, Chung-Ho;O, Joo-Hyun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • Purpose: To determine appropriate sampling frequency and time of multiple blood sampling dual exponential method with $^{99m}Tc$-DTPA for calculating glomerular filtration rate (GFR). Materials & Methods: Thirty four patients were included in this study. Three mCi of $^{99m}Tc$-DTPA was intravenously injected and blood sampling at 9 different times, 5ml each, were done. Using the radioactivity of serum, measured by gamma counter, the GFR was calculated using dual exponential method and corrected with the body surface area. Using spontaneously chosen 2 data points of serum radioactivity, 15 collections of 2-sample GFR were calculated. And 10 collections of 3-sample GFR and 12 collections of 4-sample GFR were also calculated. Using the 9-sample GFR as a reference value, degree of agreement was analyzed with Kendall's $\tau$ correlation coefficients, mean difference and standard deviation. Results: Although some of the 2-sample GFR showed high correlation coefficient, over or underestimation had evolved as the renal function change. The 10-120-240 min 3-sample GFR showed a high correlation coefficient (${\tau}=0.93$), minimal difference ($Mean{\pm}SD=-1.784{\pm}3.972$), and no over or underestimation as the renal function changed. The 4-sample GFR showed no better accuracy than the 3-sample GFR. Conclusions: In the wide spectrum of renal function, the 10-120-240 min 3-sample GFC could be the best choice for estimating the patients' renal function.

Development of Program for Renal Function Study with Quantification Analysis of Nuclear Medicine Image (핵의학 영상의 정량적 분석을 통한 신장기능 평가 프로그램 개발)

  • Song, Ju-Young;Lee, Hyoung-Koo;Suh, Tae-Suk;Choe, Bo-Young;Shinn, Kyung-Sub;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.89-99
    • /
    • 2001
  • Purpose: In this study, we developed a new software tool for the analysis of renal scintigraphy which can be modified more easily by a user who needs to study new clinical applications, and the appropriateness of the results from our program was studied. Materials and Methods: The analysis tool was programmed with IDL5.2 and designed for use on a personal computer running Windows. For testing the developed tool and studying the appropriateness of the calculated glomerular filtration rate (GFR), $^{99m}Tc$-DTPA was administered to 10 adults in normal condition. In order to study the appropriateness of the calculated mean transit time (MTT), $^{99m}Tc-DTPA\;and\;^{99m}Tc-MAG3$ were administered to 11 adults in normal condition and 22 kidneys were analyzed. All the images were acquired with ORBITOR. the Siemens gamma camera. Results: With the developed tool, we could show dynamic renal images and time activity curve (TAC) in each ROI and calculate clinical parameters of renal function. The results calculated by the developed tool were not different statistically from the results obtained by the Siemens application program (Tmax: p=0.68, Relative Renal Function: p:1.0, GFR: p=0.25) and the developed program proved reasonable. The MTT calculation tool proved to be reasonable by the evaluation of the influence of hydration status on MTT. Conclusion: We have obtained reasonable clinical parameters for the evaluation of renal function with the software tool developed in this study. The developed tool could prove more practical than conventional, commercial programs.

  • PDF

Study on Glomerular Filtration Rate comparison according to renal depth measurement of kidney donors (신 공여자에서 신장 깊이 측정에 따른 사구체여과율의 비교에 관한 고찰)

  • Lee, Han Wool;Park, Min Soo;Kang, Chun Goo;Cho, Seok Won;Kim, Joo Yeon;Kwon, O Jun;Lim, Han Sang;Kim, Jae Sam;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.48-56
    • /
    • 2014
  • Purpose $^{99m}Tc$-DTPA renal scintigraphy serves as a key indicator to measure a kidney donor's Glomerular Filtration Rate (GFR) and determine the possibility of kidney transplant. The Gates method utilized to measure GFR considers 3 variables of renal depth, injection dose, and net kidney counts. In this research, we seek to compare changes in kidney donors' GFR according to renal depth measurement methods of the 3 variables. Materials and Methods We investigated 32 kidney donors who had visited the hospital from October, 2013 to March, 2014 and received abdominal CT and $^{99m}Tc$-DTPA GFR examination. With the cross-section image of the CT and the lateral image from a gamma camera, we measured the renal depth and compared with renal depth calculation equations-Tonnesen, Taylor, and Itoh methods. Renal depth-specific GFR was calculated by using Xeleris Ver. 2.1220 of GE. Then the results were compared with MDRD (Modification of Diet Renal Disease) GFRs based on serum creatinine level. Results The renal depths measured based on the CT and gamma camera images showed high correlation. Tonessen equation gave the lowest GFR value while the value calculated by using the renal depth of CT image was the highest with a 16.62% gap. MDRD GFR showed no statistically significant difference among values calculated through Taylor, Itoh, CT and gamma camera renal depth application (P>0.05), but exhibited a statistically significant change in the value based on Tonnesen equation (P<0.05). Conclusion This research has found that, in GFR evaluation in kidney donors by utilizing $^{99m}Tc$-DTPA, Tonnesen equation-based Gates method underestimated the value than the MDRD GFR. Therefore, if a MDRD GFR value shows a huge difference from the actual examination value, using an image-based renal depth measurement, instead of Tonnesen equation applied to Gates method, is expected to give an accurate GFR value to kidney donors.

  • PDF

Surgical Outcome of Patients with Ischemic Cardiomyopathy Selected by the Results of Myocardial Viability by Preoperative F-18 FDG PET (F-18 FDG 양전자단층촬영을 이용한 생존심근 평가 후 수술한 허혈성 심근병증 환자의 수술 결과)

  • Kim, Jae-Sung;Lee, Dong-Soo;Hong, Suk-Keun;Lee, Young-Tak;Kim, Yu-Kyeong;Kim, Youn-Jung;Moon, Keon-Sik;Won, Tae-Kyoung;Hwang, Hweung-Kon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.276-284
    • /
    • 2000
  • Purpose: We investigated the operative outcome after bypass surgery in patients selected using viability criteria on F-18 FDG PET. Materials and Methods: Rest-24hr delay redistribution imaging of Tl-201 SPECT and F-18 FDG PET were performed in 11 patients. Seven of these 11 patients (6 men, 1 woman) were evaluated to have viable myocardium by F-18 FDG PET. Changes in symptoms and left ventricular ejection fraction (LVEF) after operation were evaluated. Results: In seven of 11 patients, a significant amount of viable myocardium was found on F-18 FDG PET and Tl-201 SPECT. Severity of both chest pain and dyspnea improved markedly in all patients. Mean LVEF improved from 22% to 32%. Conclusion: F-18 FDG PET could be used to select the patients who will benefit from coronary artery bypass surgery.

  • PDF

Captopril Enhanced $^{99m}Tc-DMSA$ Renal Scintigraphy in A Case of Renovascular Hypertension Due to Branch Renal Artery Stenosis (신동맥분지협착에 의한 신혈관성고혈압 예에서 캅토프릴투여후 $^{99m}Tc-DMSA$ 신 스캔)

  • Yang, W.S.;Kim, Y.S.;Earm, J.H.;Kim, S.E.;Lee, D.S.;Han, J.S.;Chung, J.K.;Kim, S.;Lee, M.C.;Lee, J.S.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.325-331
    • /
    • 1990
  • Radionuclide renal scintigraphies were performed in a 24-year-old man with right renal artery branch stenosis. Captopril enhanced $^{99m}Tc-DTPA$ renal scintigraphy revealed no abnormal finding in the right kidney. But, $^{99m}Tc-DMSA$ renal scintigraphy showed regional cortical photon deficient area corresponding to the area supplied by the stenotic branch artery. The defect size increased in captopril enhanced $^{99m}Tc-DMSA$ renal scintigrphy and nearly disappeared after successful transluminal renal angioplasty. This case suggests that the captopril enhanced $^{99m}Tc-DMSA$ renal scintigraphy may be a useful method in the evaluation of renovascular hypertension, especially due to branch renal srtery stenosis.

  • PDF

Normal Values of Cerebral Blood Flow in Korean Determined by Tc-99m DTPA (Technetium 99m DTPA를 이용(利用)한 정상(正常) 한국인(韓國人)의 뇌혈류량(腦血流量) 측정(測定))

  • Lee, Shin-Hyung;Cha, Soon-Joo;Lee, Min-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.1
    • /
    • pp.77-81
    • /
    • 1985
  • There are several methods for measurement of cerebral blood flow. A method using Tc-99m DTPA which was injected via antecubital vein and monitored extracranially with gamma camera is described here. In this method, the brain scan and CBF mesurement were performed with scan and CBF were usually studied separately. The results were as follow: 1) Total candidates were 53, male 34 and female 19, who have no evidence of neurologic, cardiac or kidney problems. 2) By this method, the normal CBF of Korean was $54.12{\pm}6.49ml/min/100g$ of brain tissue. 3) The CBF of male was $54.06{\pm}5.9ml/min/100g$ of brain tissue, female was $54.89{\pm}6.51ml/min/100g$, so there was no definite sex difference. 4) The CBF under 10 years of age was $54.12{\pm}2.5ml/min/100g$, $11\sim20years$ of age was $52.33{\pm}6.1ml/min/100g$, $21\sim60years$ of age was $52.86{\pm}5.06ml/min/100g$, and over 61years of age was $55.43{\pm}4.84ml/min/100g$, so there was no significant difference of CBF by age.

  • PDF