Study on Glomerular Filtration Rate comparison according to renal depth measurement of kidney donors

신 공여자에서 신장 깊이 측정에 따른 사구체여과율의 비교에 관한 고찰

  • Lee, Han Wool (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Park, Min Soo (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kang, Chun Goo (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Cho, Seok Won (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kim, Joo Yeon (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kwon, O Jun (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Lim, Han Sang (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kim, Jae Sam (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Park, Hoon-Hee (Department of Radiological Technology, Shingu College)
  • 이한울 (연세의료원 세브란스병원 핵의학과) ;
  • 박민수 (연세의료원 세브란스병원 핵의학과) ;
  • 강천구 (연세의료원 세브란스병원 핵의학과) ;
  • 조석원 (연세의료원 세브란스병원 핵의학과) ;
  • 김주연 (연세의료원 세브란스병원 핵의학과) ;
  • 권오준 (연세의료원 세브란스병원 핵의학과) ;
  • 임한상 (연세의료원 세브란스병원 핵의학과) ;
  • 김재삼 (연세의료원 세브란스병원 핵의학과) ;
  • 박훈희 (신구대학교 방사선과)
  • Received : 2014.09.26
  • Accepted : 2014.10.25
  • Published : 2014.11.08

Abstract

Purpose $^{99m}Tc$-DTPA renal scintigraphy serves as a key indicator to measure a kidney donor's Glomerular Filtration Rate (GFR) and determine the possibility of kidney transplant. The Gates method utilized to measure GFR considers 3 variables of renal depth, injection dose, and net kidney counts. In this research, we seek to compare changes in kidney donors' GFR according to renal depth measurement methods of the 3 variables. Materials and Methods We investigated 32 kidney donors who had visited the hospital from October, 2013 to March, 2014 and received abdominal CT and $^{99m}Tc$-DTPA GFR examination. With the cross-section image of the CT and the lateral image from a gamma camera, we measured the renal depth and compared with renal depth calculation equations-Tonnesen, Taylor, and Itoh methods. Renal depth-specific GFR was calculated by using Xeleris Ver. 2.1220 of GE. Then the results were compared with MDRD (Modification of Diet Renal Disease) GFRs based on serum creatinine level. Results The renal depths measured based on the CT and gamma camera images showed high correlation. Tonessen equation gave the lowest GFR value while the value calculated by using the renal depth of CT image was the highest with a 16.62% gap. MDRD GFR showed no statistically significant difference among values calculated through Taylor, Itoh, CT and gamma camera renal depth application (P>0.05), but exhibited a statistically significant change in the value based on Tonnesen equation (P<0.05). Conclusion This research has found that, in GFR evaluation in kidney donors by utilizing $^{99m}Tc$-DTPA, Tonnesen equation-based Gates method underestimated the value than the MDRD GFR. Therefore, if a MDRD GFR value shows a huge difference from the actual examination value, using an image-based renal depth measurement, instead of Tonnesen equation applied to Gates method, is expected to give an accurate GFR value to kidney donors.

$^{99m}Tc$-DTPA 신장 신티그래피는 신공여자에게서 사구체 여과율을 평가하고, 신장 이식 가능여부를 결정하는데 있어 중요한 지표가 된다. 사구체 여과율을 측정하는데 이용되는 Gates법은 신장 깊이, 주사량, 순 신장 계수의 3가지 변수들을 고려해야 한다. 본 연구에서는 3가지 변수 중 신장 깊이 측정방법에 따른 신공여자의 사구체 여과율 변화를 비교 평가하고자 한다. 2013년 10월부터 2014년 3월까지 본원에 내원하여 복부 CT와 $^{99m}Tc$-DTPA 사구체 여과율 검사를 시행한 32명의 신공여자를 대상으로 하였다. CT에서의 횡단면 영상과 감마카메라에서 획득한 측면 영상으로 신장 깊이를 측정하고, 신장 깊이 산출 공식인 Tonnesen, Taylor, Itoh법과 비교하였다. GE사의 Xeleris Ver. 2.1220을 이용하여 신장 깊이에 따른 사구체 여과율을 산출한 후, 혈청 크레아티닌 수치를 이용한 MDRD(Modification of Diet Renal Disease) 사구체 여과율과 비교 분석하였다. CT와 감마카메라 영상에서 측정한 신장 깊이는 높은 상관관계를 보였다. 사구체 여과율은 Tonessen 공식을 적용하여 산출한 값이 최소치로 나타났고, CT 영상에서의 신장 깊이를 대입하여 산출한 값이 최대치로 나타났으며, 이를 적용한 사구체 여과율은 16.62%의 차이를 보였다. MDRD 사구체 여과율은 Taylor, Itoh, CT 및 감마카메라에서의 신장 깊이를 적용한 값에서는 통계적으로 유의한 차이를 보이지 않았으나 (p>0.05), Tonnesen 공식을 적용하여 산출한 값에서는 유의하게 나타났다(p < 0.05). CT 측정값을 대입하여 산출한 사구체 여과율 또한 MDRD, Taylor, Itoh, 감마카메라에서의 측정 깊이를 적용한 산출값과는 통계적으로 유의한 차이를 보이지 않았으나(p > 0.05), Tonnesen 공식을 적용하여 산출한 값에서는 유의하게 나타났다(p < 0.05). 본 연구에서는 신공여자에게서 $^{99m}Tc$-DTPA를 이용한 사구체 여과율 평가 시 Tonnesen 공식을 적용한 Gates법이 MDRD 사구체 여과율에 비하여 과소평가됨을 알 수 있었다. 따라서, MDRD 사구체 여과율과 검사 결과 산출된 값이 큰 차이를 보이는 경우 기존 Gates법에 적용되는 Tonnesen 방정식을 대신하여 Itoh 방정식을 적용 하거나 영상을 기반으로 측정한 신장 깊이를 적용하면 보다 정확한 사구체 여과율 평가가 가능할 것으로 사료된다.

Keywords