• Title/Summary/Keyword: Targeted temperature management

Search Result 12, Processing Time 0.026 seconds

Comparison of Clinical Outcomes between Rebound Hyperthermia and Non-Rebound Hypertherma Groups in Postcardiac Arrest Syndrome Patients Undergoing Targeted Temperature Management (목표체온유지치료를 적용한 심정지 후 증후군 환자에서 반동성 고체온 발생군과 비발생군의 임상결과 비교)

  • Rhee, Ha Na;Park, Jeong Yun
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.3
    • /
    • pp.99-108
    • /
    • 2023
  • Purpose : This retrospective study aims to provide basic data for intervention to improve clinical outcomes and identify the characteristics of the rebound hyperthermia (RHG) and non-rebound hyperthermia (NRHG) groups by checking body temperature in patients with post-cardiac arrest syndrome. Method : The study involved 118 patients who completed target temperature management (TTM) in an acute-care unit. Data were analyzed for frequency, percentages, mean, standard deviation, median, and quartiles, and compared using the chi-squared test and Mann-Whitney U-test. Results : Rebound hyperthermia (RH) was observed in 74 (62.7%) patients, predominantly male (69.5%), with an average age of 64.54 ± 15.98, and a body mass index of 23.22 ± 4.75kg/m2 (overweight). Hypertension (50%) was the most common co-morbidity, followed by diabetes and heart disease (33.1%). Neuron-specific enolase levels were higher in the NRHG 24, 48, and 72 hours after recovery of spontaneous circulation (p = .037, p < .001, p = .008). The APHCHE IV was also higher in the NRHG (p < .001). RH occurred 25.49 (7.28-52.96) hours after TTM completion, lasting for 2 (1-3) hours. Temperature reduction strategies included notifying doctors, administering antipyretics, and nursing intervention, with the latter being the most common at 94.6%. Half of the subjects in the RHG and 77.3% in the NRHG fell into cerebral performance categories 3, 4, and 5 (p = .003). Conclusion : RH is more likely a body mechanism related to CPR and TTM than a result of pathogenic infection. Therefore, we require an active intervention for hyperthermia, and a patient-specific nursing intervention protocol.

Childhood Fever Management: Current Practice vs Evidence (아동의 발열관리: 현황 및 과학적 근거)

  • Kim, Jin Sun
    • Child Health Nursing Research
    • /
    • v.22 no.2
    • /
    • pp.126-136
    • /
    • 2016
  • Purpose: The purposes of this review were to address misconceptions of childhood fever and fever management practice among parents and health care providers, and to identify the scientific evidences against such misconceptions and practices. Methods: Journal databases and clinical guidelines from 2000 to 2015 were searched. The search terms were fever, fever management, misconception, myth, fiction, fact, fever phobia, child, antipyretics, tepid bath, alternating use/combined use of antipyretics, and physical cooling method. Results: There are significant gaps between current concepts and practices, and the scientific evidence. Misconceptions and unrealistic concerns about childhood fever still exist among parents and even health care providers, worldwide. The evidences suggest that antipyretics should be given carefully with the aim of relieving discomfort or pain rather than decreasing the temperature itself. Alternating use of antipyretics should be discouraged due to the risk of confusion and error. Antipyretics do not prevent febrile convulsions. Moreover, the scientific evidence does not support tepid sponge massage. Conclusion: Evidence-based childhood fever management interventions should be targeted toward parents and health care providers. By adopting an evidence-based approach to nursing interventions, pediatric nurses can ensure children receive appropriate and safe fever management.

A Study on Energy Use Monitoring and Analysis Case for Small and Medium-Sized Buildings (중소형 건물에 적합한 에너지사용량 모니터링 및 분석 사례 연구)

  • Lee, Hye-Jin;Kim, Myung-Jin;Kim, Jin-Ho;Lee, Dongho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.5
    • /
    • pp.499-509
    • /
    • 2019
  • This paper discusses energy use monitoring and analysis as part of a study on a low-cost energy supply management system that links an existing database with weather information with no real-time monitor for energy demand of buildings using renewable energy, generator and energy storage systems. This study is targeted at small and medium-sized buildings and aims to monitor energy use with a small number of sensors at low cost by applying an energy management system (EMS). The present study can help overcome the limitations of high-cost EMS applied to large commercial and public buildings. We developed current, indoor temperature and human motion sensors and installed them in an office of a company in a sample building. Through these sensors, we analyzed energy use patterns and the effects of weather information and human motion on the energy use. Furthermore, we analyzed the correlations between the total KEPCO energy use of the sample building and weather by comparing these two data. The results showed that the office energy use of a company was more affected by human motions than by weather information. The comparison between the total energy use of the Building and weather information found that external temperature had an effect on the energy use.

Determination of Veterinary Antibiotic Residues: IV. Comparable Analytical Methods with EPA Methods 1694_A Review (시료 중 잔류 항생제 분석 방법: IV. EPA method 1694와 비교 가능한 기기 분석 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.670-699
    • /
    • 2016
  • In this study, 16 antibiotics were selected from among the top 30 veterinary antibiotics sold in South Korea in 2014, as well as from among the pharmaceuticals targeted by EPA method 1694, in order to review analytical methods for the detection of trace levels of antibiotics in environmental samples: surface water, soils, animal origin foods, and manures. LC-MS/MS was heavily used. In the chromatography for the detection of the selected antibiotics, the $C_{18}$ column was mostly used at the temperature of $30{\sim}40^{\circ}C$. Water and methanol/acetonitrile were commonly chosen as a nonpolar and a polar mobile phase, respectively. Gradient elution was applied to separate multiclass antibiotics. Volatile additives, such as formic acid, acetic acid, and ammonium acetate were mixed with the mobile phase to improve the ionization efficiency of analytes and the sensitivity in MS detection. Electrospray ionization (ESI) was widely used in the LC-MS/MS and positive ionization was preferred to determine the selected antibiotics. A protonated $[M+H]^+$ molecule was selected as a precursor ion, and its two transitions were analyzed, one for quantitative measurement and the other for confirmation. This study reviewed linearity of the calibration curve, recovery, repeatability, method detection limits (MDLs), and method quantification limits (MQLs) for each target compound used to validate the developed analytical methods.

Factors Related to Sanitary Management Performance Based on HACCP System in School Foodservice - Seoul, Gyeonggi, Kangwon and Choongchung Areas in Korea - (HACCP 시스템 적용 학교급식 위생관리 수행수준에 영향을 미치는 요인 - 서울, 경기, 강원, 충청지역을 중심으로 -)

  • Kim, Gyoung-Mi;Lee, Sim-Yeol
    • Korean Journal of Community Nutrition
    • /
    • v.14 no.6
    • /
    • pp.817-830
    • /
    • 2009
  • The purpose of this study was to analysis the sanitary management performance based on HACCP system for school foodservice. This study was carried out from September 2008 until December 2008 and is targeted towards schools' dietitians that work at schools with school foodservice. The regional distribution of this research is as follows; 377 schools in Seoul, 648 schools in Gyeonggido, 160 schools in Kangwondo, 438 schools in Choongchungdo equaling 1,623 schools in total. When school foodservices were put through sanitation management achievement level analysis applied by the HACCP system, results displayed that management of temperature (3.96 points), time (4.08 points), and cross-contamination (4.07 points) were all below the average achievement level. HACCP system's achievement level based on the TQM showed that areas for strategy development, leadership, information and analysis had low achievement levels. Achievement levels for CCP are quality check, delivery/distribution process, sterilization/cleansing of food's contact surface. As a result of multiple regression analysis of the factors that influenced sanitation management achievement level of school foodservice HACCP system; sanitary job standard showed 35.6% and CCP achievement levels showed 26.8% explanatory rate. In particular, Kangwondo's number of foodservice provided to per cook was small. Also, the better the processing management was assessed, the higher the sanitary job standard achievement level became resulting to a explanatory rate of 39.5%. Elementary schools showed a higher explanatory rate of 37.0% than middle and high schools. CCP achievement levels in middle and high schools with self-operated foodservice had a 28.0% variable explanatory rate, which was the highest. The better the drainage system, leadership and assessments turned out to be, the higher the CCP achievement levels became. In summary, to revitalize HACCP system that is based on the TQM, it is considered that proper database of HACCP system for school foodservice's sanitation management be constructed and more emphasis should be put on strategy development to improve customers' satisfactory level. In addition, improvements in achievement levels of time, temperature, and cross-contamination for sanitary job standard and CCP achievement level are essential.

Research on Durability Assessment of Asbestos Stabilizer for Asbestos-containing Ceiling Materials (석면 함유 천장재에 대한 석면 안정화제 내구성 평가 연구)

  • Ha, Joo-Yeon;Shin, Hyun-Gyoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • Objectives: For testing asbestos stabilizer products which are used for the maintenance and management of asbestos-containing materials, durability assessment should accompany the evaluation of basic properties and performance. Therefore, in this study we designed a testing method and constructed a database of durability performance, thereby providing basic data for reliability studies of asbestos stabilizer. Methods: Since the ceiling materials targeted in this study are interior materials, test conditions of 95% relative humidity and 60℃ temperature were designed in consideration of the effect of high relative humidity in summer and seasonal indoor temperatures. Plate-shaped specimens treated with asbestos stabilizers were maintained in a thermo-hygrostat for 5, 10, and 20 days, and then the asbestos scattering prevention rate was measured by air erosion testing. Results: The scattering concentration tended to increase with time under the single humidity condition, and exceeded the indoor air quality standard of 0.01 f/cc, during the 20 days of maintenance. On the other hand, there was little change according to the temperature condition. In the case of a complex condition with temperature and humidity, the results were similar to the humidity test, but the scattering concentration increased more sharply at 20 days. Conclusions: The main deterioration factor that affects the durability of asbestos stabilizer is humidity, and the deterioration is caused by a mechanism in which the stabilizer coated on the surface is re-dissolved by moisture and evaporates or the coating layer is peeled off, which is accelerated by high temperatures.

Microbiological Quality and Safety Assessment of Salad in Lunchbox's according to the Holding Time and Temperature - Convenience and Franchise Stores - (보관시간과 온도에 따른 판매 도시락의 샐러드 미생물 품질 평가 - 편의점과 프랜차이즈 도시락 전문점 제품 -)

  • Choi, Jung-Hwa;Wang, Tae-Hwan;Kwak, Tong-Kyung
    • Korean journal of food and cookery science
    • /
    • v.32 no.6
    • /
    • pp.724-733
    • /
    • 2016
  • Purpose: This study was to evaluate the microbiological quality of salads in lunchbox's based on the holding time and temperature at convenience and franchise stores. Methods: Cabbage salad and crab meat salad were targeted for microbiological quality assessment. They were tested for aerobic plate counts, coliforms, Escherichia coli, Staphylococcus aureus and Enterobacteriaceae and assessment were performed by Korean Food Standards Codex. Results: In cabbage salad at convenience franchise store's at $5^{\circ}C$, the aerobic plate counts did not exceed the Korean Food Standards Codex. For cabbage salad stored at $25^{\circ}C$, the aerobic plate counts was 5.08 log CFU/g we hours after purchase, which exceeded the Korean Food Standards Codex. In case of cabbage salad in franchise store, the E. coli and S. aureus count exceeded Korean Food Standards Codex 3 hours after purchase. Microbiological analysis did not exceed the Korean Food Standards Codex at $5^{\circ}C$ in crab meat salad in convenience store. At $25^{\circ}C$, the aerobic plate count was detected at 4.45 log CFU/g after 32 hours, coliforms, E. coli, and S. aureus did not detect, but Enterobacteriaceae was found to be 2.34 log CFU/g after 9 hours in franchise store's crab salad. Coliforms was detected at 1.18 log CFU/g after 3 hours, and S. aureus was detected at 2.04 log CFU/g after 6 hours at $25^{\circ}C$ in the franchise store. The lunchbox' salad under cold storage ($5^{\circ}C$) generally meet the Korean Food Standards Codex. Conclusion: The results indicate an urgent need to implement proper management guidelines for the production of lunchbox foods to ensure microbiological safety, and to improve the shelf life from production to consumption.

A LSTM Based Method for Photovoltaic Power Prediction in Peak Times Without Future Meteorological Information (미래 기상정보를 사용하지 않는 LSTM 기반의 피크시간 태양광 발전량 예측 기법)

  • Lee, Donghun;Kim, Kwanho
    • The Journal of Society for e-Business Studies
    • /
    • v.24 no.4
    • /
    • pp.119-133
    • /
    • 2019
  • Recently, the importance prediction of photovoltaic power (PV) is considered as an essential function for scheduling adjustments, deciding on storage size, and overall planning for stable operation of PV facility systems. In particular, since most of PV power is generated in peak time, PV power prediction in a peak time is required for the PV system operators that enable to maximize revenue and sustainable electricity quantity. Moreover, Prediction of the PV power output in peak time without meteorological information such as solar radiation, cloudiness, the temperature is considered a challenging problem because it has limitations that the PV power was predicted by using predicted uncertain meteorological information in a wide range of areas in previous studies. Therefore, this paper proposes the LSTM (Long-Short Term Memory) based the PV power prediction model only using the meteorological, seasonal, and the before the obtained PV power before peak time. In this paper, the experiment results based on the proposed model using the real-world data shows the superior performance, which showed a positive impact on improving the PV power in a peak time forecast performance targeted in this study.

A Study on the Factors Affecting the Air Environment in Chungnam Province - Focusing on Cheonan, Dangjin, and Seosan (충남 대기환경 영향요인에 관한 연구 - 천안, 당진, 서산 등을 중심으로)

  • Hwang, Kyu-Won;Kim, Jinyoung;Kwon, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.118-127
    • /
    • 2021
  • Recently, the public's interest in the air environment has increased, and public health is threatened by fine particulate matter. Furthermore, the government continues efforts to improve air quality by expanding the monitoring of air pollutants and reinforcing environmental standards. Since air quality differs depending on the region in the Korean Peninsula, it is currently necessary to identify the cause and search for influencing factors. In this study, the atmospheric environment and regional differences in cities located in the Chungnam Province were observed. As a research method, regression analysis was performed for weather conditions, such as temperature, wind speed, precipitation, and season and targeted at air pollutants, such as SO2, NO2, CO, O3, PM10, and PM2.5, as well as heavy metals contained in particulate matter, such as Pb, Cd, Cr, Cu, Ni, As, Mn, Fe, Al, Ca, and Mg. In the case of PM10, the concentrations of Mn(0.4884) in Cheonan, CO(0.3329) in Dangjin, and Mg(0.5691) in Seosan were highest. In the case of PM2.5, Cheonan NO2(0.4759), Dangjin CO(0.4128), and Seosan NO2(0.3715) were significantly affected. In summary, the influencing factors vary according to the region in Chungnam province in terms of air quality, and there is a difference in the degree of contribution. Therefore, it is considered that the Korean government's management of air quality is required for each region.