• Title/Summary/Keyword: Target Region

Search Result 1,200, Processing Time 0.03 seconds

Biotope Types and Mapping for Ecological Management of Tricholoma matsutake Production Area: The Case of Expressway in Yangyang-gun, Gangwon-do (송이생산지의 생태적 관리를 위한 소나무비오톱 유형화 및 지도 작성: 강원도 양양군 동서고속도로 건설구간을 중심으로)

  • Kim, Jeong-Ho;Choi, Song-Hyeon;Yoon, Yong-Han
    • Journal of Environmental Policy
    • /
    • v.11 no.3
    • /
    • pp.25-47
    • /
    • 2012
  • This research is to suggest an ecological management methods by classification of biotope type and its mapping for Tricholoma matsutake. The target area was construction site of the East Hongchun - Yangyang Highway (Yangyang section) where massive production of Tricholoma matsutakes is in place. Specifically, the 700 m long range of area around the road route, Yangyang section, which is over a total area of $19,79km^2$. The flow of this research was as follows: first studied were the characteristics of the Yangyang Tricholoma matsutakes; second, reviews on previous studies on Tricholoma matsutakes; third, the formulation of standards and processes of biotope type considering Tricholoma matsutake production; and fourth, mapping of biotope considering the production area of Tricholoma matsutake. In 24.77% of the region, slope angle measured $30{\sim}40^{\circ}C$, which is suitable for Tricholoma matsutake production. Also, 17.44% of the region had southward vegetation structures, and as for the Pinus densiflora; 26.00% had average receipts; the tree ages was $38{\pm}8.34$ years; and the average density of canopy layer was $9.55{\pm}4.89/100m^2$. The soil acidity (pH) values of 5.0 to 5.6(47.96%) > 5.6 to 7.0(42.90%) > 4.0 to 5.0(9.14%) were slightly high for Tricholoma matsutake growth; but 57.10% of the area had a soil pH of 4.0-5.6. The organic horizon (A0 layer) was $3.39{\pm}2.14cm$, and the mean depths were 4-6cm(78.03%) > 0-2cm(18.10%) > 2-4cm(3.87%). Based on the results of previous studies and field researches on the presence of vegetation (the pine dominance ratio), the topographic structure (the terrain characteristics and slopes), the receipt, the soil structure (the soil acidity and the organic layers interposed between the depths), and the vegetation density, six clusters based on the identified types of biotopes are produced in this paper. Area of distribution according to the type of biotope was Tricholoma matsutake of the potential-production (II) biotope (32.86%) > Tricholoma matsutake of the inadequate-production biotope (22.17%) > Tricholoma matsutake of the adequate (II)-production biotope (17.79%) > Tricholoma matsutake of the adequate (I)-production biotope (14.86%) > Tricholoma matsutake of the potential-production (I) biotope (9.77%) > Tricholoma matsutake of the produced biotope (2.55%).

  • PDF

Effect of an Acrylic Plate and SSD on Dose Profile and Depth Dose Distribution of 9 MeV Electron Beams (에너지 저하체로서 아크릴과 SSD 가 9MeV 전자선의 측방 및 깊이선량분포에 미치는 효과)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.65-71
    • /
    • 1998
  • The aims are to evaluate the effects of an 1.0 cm acrylic plate and SSD on the dose profile and depth dose distribution of 9 MeV electron beam and to analyse adequacy for using an acrylic plate to reduce energy of electron beams. An acrylic plate of 1.0 cm thickness was used to reduce energy of 9 MeV electron beam to 7 MeV. The plate was put on an electron applicator at 65.4 cm distance from x-ray target. The size of the applicator was 10${\times}$l0cm at 100 cm SSD. For 100cm, l05cm and 110cm SSD, depth dose on beam axis and dose profiles at d$\_$max/ on two principal axes were measured using a 3D water phantom. From depth dose distributions, d$\_$max/, d$\_$85/, d$\_$50/ and R$\_$p/, surface dose, and mean energy and peak energy at surface were compared. From dose profiles flatness, penumbra width and actual field size were compared. For comparison, 9 MeV electron beams were measured. Surface dose of 7 MeV electron beams was changed from 85.5% to 82.2% increasing SSD from 100 cm to 110 cm, and except for dose buildup region, depth dose distributions were independent of SSD. Flatness of 7 MeV ranged from 4.7% to 10.4% increasing SSD, comparing 1.4% to 3.5% for 9 MeV. Penumbra width of 7 MeV ranged from 1.52 cm to 3.03 cm, comparing 1.14 cm to 1.63 cm for 9 MeV. Actual field size increased from 10.75 cm to 12.85 cm with SSD, comparing 10.32 cm to 11.46 cm for 9 MeV. Virtual SSD's of 7 and 9 MeV were respectively 49.8 cm and 88.5cm. In using energy reducer in electron therapy, depth dose distribution were independent of SSD except for buildup region as well as open field. In case of using energy reducer, increasing SSD made flatness to deteriorate more severely, penumbra width more wide, field size to increase more rapidly and virtual SSD more short comparing with original electron beam. In conclusion, it is desirable to use no energy reducer for electron beam, especially for long SSD.

  • PDF

The Distribution and Characteristics of Use of Urban Farms - A Case Study of the Siji Region in Daegu Metropolitan City - (도시텃밭의 분포 및 이용 특성 - 대구광역시 시지지역을 사례로 -)

  • Nam, Tae-Ho;Jung, Tae-Yeol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.6
    • /
    • pp.1-9
    • /
    • 2014
  • Within the urban area, over the past decades unused land and public land such as streams and road sides have given urban residents a space for farming (urban farms). However, because this use is illegal, farming in unused and public lands could cause conflicts between urban farm users and land owners, degrade the quality of the urban landscape and contaminate the environment. Therefore, the purpose of this study is to provide a way of legalizing these farming practices that have been cultivated in unused urban areas and public lands. This study analyzed the status of distribution and use of the urban farms that have been scattered around urban areas in many different forms. The survey was conducted through on-the-spot investigation and in-person interviews with farm users and those who were operating weekend farms in the Siji region of Daegu Metropolitan City. According to the results of this study, urban farms were mainly found in green areas that were easily accessible from residential districts and prohibited from development. It was also revealed that the nearer to the border of the residential districts the sites of urban farms were, the larger the number of urban farms was. When it comes to the type of land use, although the proportion of urban farms located in farmlands was very high, the proportion of those located on state-owned lands such as roads, railroads and streams was also high, over 1/3 of that of the former sites. Among the users of urban farms, the percentage of users who were farming private-owned land for free was highest and that of state-owned land without permission ranked second. Most people who were farming unused lands or state-owned lands without permission, such as streams, roads, railroads, were the elderly. This shows the potential of farms in urban area as leisure activities spaces for the elderly. Even though this study has limitations in that the survey target area was selected in a certain area and the sizes of all urban farms were not measured by surveying apparatus and instruments, it helps to determine the characteristics of use and distribution associated with the spaces of urban farming, and to raise the importance and necessity of legalizing urban farms cultivated illegally in public land.

The current state and prospects of travel business development under the COVID-19 pandemic

  • Tkachenko, Tetiana;Pryhara, Olha;Zatsepina, Nataly;Bryk, Stepan;Holubets, Iryna;Havryliuk, Alla
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.12spc
    • /
    • pp.664-674
    • /
    • 2021
  • The relevance of this scientific research is determined by the negative impact of the COVID-19 pandemic on the current trends and dynamics of world tourism development. This article aims to identify patterns of development of the modern tourist market, analysis of problems and prospects of development in the context of the COVID-19 pandemic. Materials and methods. General scientific methods and methods of research are used in the work: analysis, synthesis, comparison, analysis of statistical data. The analysis of the viewpoints of foreign and domestic authors on the research of the international tourist market allowed us to substantiate the actual directions of tourism development due to the influence of negative factors connected with the spread of a new coronavirus infection COVID-19. Economic-statistical, abstract-logical, and economic-mathematical methods of research were used during the process of study and data processing. Results. The analysis of the current state of the tourist market by world regions was carried out. It was found that tourism is one of the most affected sectors from COVID-19, as, by the end of 2020, the total number of tourist arrivals in the world decreased by 74% compared to the same period in 2019. The consequence of this decline was a loss of total global tourism revenues by the end of 2020, which equaled $1.3 trillion. 27% of all destinations are completely closed to international tourism. At the end of 2020, the economy of international tourism has shrunk by about 80%. In 2020 the world traveled 98 million fewer people (-83%) relative to the same period last year. Tourism was hit hardest by the pandemic in the Asia-Pacific region, where travel restrictions are as strict as possible. International arrivals in this region fell by 84% (300 million). The Middle East and Africa recorded declines of 75 and 70 percent. Despite a small and short-lived recovery in the summer of 2020, Europe lost 71% of the tourist flow, with the European continent recording the largest drop in absolute terms compared with 2019, 500 million. In North and South America, foreign arrivals declined. It is revealed that a significant decrease in tourist flows leads to a massive loss of jobs, a sharp decline in foreign exchange earnings and taxes, which limits the ability of states to support the tourism industry. Three possible scenarios of exit of the tourist industry from the crisis, reflecting the most probable changes of monthly tourist flows, are considered. The characteristics of respondents from Ukraine, Germany, and the USA and their attitude to travel depending on gender, age, education level, professional status, and monthly income are presented. About 57% of respondents from Ukraine, Poland, and the United States were planning a tourist trip in 2021. Note that people with higher or secondary education were more willing to plan such a trip. The results of the empirical study confirm that interest in domestic tourism has increased significantly in 2021. The regression model of dependence of the number of domestic tourist trips on the example of Ukraine with time tendency (t) and seasonal variations (Turˆt = 7288,498 - 20,58t - 410,88∑5) it forecast for 2020, which allows stabilizing the process of tourist trips after the pandemic to use this model to forecast for any country. Discussion. We should emphasize the seriousness of the COVID-19 pandemic and the fact that many experts and scientists believe in the long-term recovery of the tourism industry. In our opinion, the governments of the countries need to refocus on domestic tourism and deal with infrastructure development, search for new niches, formats, formation of new package deals in new - domestic - segment (new products' development (tourist routes, exhibitions, sightseeing programs, special rehabilitation programs after COVID) -19 in sanatoriums, etc.); creation of individual offers for different target audiences). Conclusions. Thus, the identified trends are associated with a decrease in the number of tourist flows, the negative impact of the pandemic on employment and income from tourism activities. International tourism needs two to four years before it returns to the level of 2019.

Usefulness Evaluation of Open Mouth View when PET/CT scan In Tongue Cancer Patients (Tongue Cancer 환자에서 PET/CT 검사 시 Open Mouth 촬영법의 유용성 평가)

  • Kim, Jae Hwan;Yun, Jong Jun;Jung, Ji Wook;Kim, Jung Wook;Hwang, Ju Won;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.14-20
    • /
    • 2016
  • Purpose Tongue cancer is 1.8% of all cancer tumors occur in the tongue, it is known that the high incidence enough to account for 75% of oral cancer conducted a PET / CT examination for early diagnosis, metastasis, staging, etc. and. Tongue when PET / CT scan of a cancer patient and a Torso taken to close mouth lesions if the condition was caused due to the overlapping or corresponding artifacts are not clearly observed. The purpose of this study is to evaluate the changes that occur during PET / CT scan with open mouth and its usefulness under. Materials and Methods From June 2015 to March 2016 complained of herein by May 21 had received a diagnosis of tongue cancer underwent PET / CT scan patients were treated with a target (16 males, 5 female). The first was taken to close mouth Torso state, it was taken to add 1 bed open mouth condition. Tumor (T), measuring the Normal Tongue (NT), Lymph Node (LN) standard intake coefficient by setting a region of interest in the (standardized uptake value, SUV) SUVmean, the average value was measured SUVmax, drawn to each region of interest 3 times and Background (Carotid artery) was out of the SUV. In Chapter 3 of the slice to the tumor clearly visible by setting the region of interest to measure the change Tumor size was calculated average value. Gross Image resolution assessment were analyzed statistically through were divided into 1-5 points by the Radiation 7 people in 2, more than five years worked in specialized nuclear medicine compare to proceed with the blind test nonparametric test (wilcoxon signed rank test). (SPSS ver.18) Results $SUV_{mean}$ T's were in close mouth $5.01{\pm}2.70$ with open mouth $5.48{\pm}2.88$ (P<0.05), $SUV_{max}$ were respectively $8.78{\pm}5.55$ and $9.70{\pm}5.99$ (P<0.05). $SUV_{mean}$ in the NT were respectively $0.43{\pm}0.30$ and $0.34{\pm}0.24$ (P=0.20), $SUV_{max}$ was $0.56{\pm}0.34$ and $0.45{\pm}0.25$ (P=0.204). LN $SUV_{mean}$ were respectively $1.62{\pm}1.43$ and $1.69{\pm}1.49$ (P=0.161), $SUV_{mean}$ was $2.09{\pm}1.88$ and $1.99{\pm}1.74$ (P=0.131). Tumor size change is close mouth $4.96{\pm}4.66cm^2$ $5.33{\pm}4.64cm^2$ with 7.45% increase was (P<0.05), gross image resolution evaluation is $2.87{\pm}0.73$, $3.77{\pm}0.68$ with open mouth examinations 30.5% increase was (P<0.05). Conclusion Tumor SUV on the changes that had an increase in open mouth during inspection, the normal tongue and lymph node, but there was no significant difference in the change slightly. It is also one open mouth PET / CT scan will provide improved image to all patients with tongue cancer, but it could be confirmed that similar overall through the blind test, or tumor size changes and showing a high resolution image. It can be the perfect alternative method for problems that occur when the close mouth Open mouth PET / CT scan, but is believed to be through the open mouth to observe the boundary of overlapping or tumor of the oral cavity other structures a little more clearly. Tongue cancer patients how to recommend that the shooting further open mouth PET / CT.

  • PDF

Air Cavity Effects on the Absorbed Dose for 4-, 6- and 10-MV X-ray Beams : Larynx Model (4-, 6-, 10-MV X-선원에서 공기동이 흡수선량에 미치는 효과 : 후두모형)

  • Kim Chang-Seon;Yang Dae-Sik;Kim Chul-Yong;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.393-402
    • /
    • 1997
  • Purpose : When an x-ray beam of small field size is irradiated to target area containing an air cavity, such as larynx, the underdosing effect is observed in the region near the interfaces of air and soft tissue. With a larynx model, air cavity embedded in tissue-equivalent material, this study is intonded for examining Parameters, such as beam quality, field size, and cavity size, to affect the dose distribution near the air cavity. Materials and Methods : Three x-rar beams, 4-, 6- and 10-MV, were employed to Perform a measurement using a 2cm $(width){\times}L$ (length in cm, one side of x-ray field used 2cm (height) air cavity in the simulated larynx. A thin window parallel-plate chamber connected to an electrometer was used for a dosimetry system. A ratio of the dose at various distances from the cavity-tissue interface to the dose at the same points in a homogeneous Phantom (ebservedlexpected ratio, O/E) normalized buildup curves, and ratio of distal surface dose to dose at the maximum buildup depth were examined for various field sizes. Measurement for cavity size effect was performed by varying the height (Z) of the air cavity with the width kept constant for several field sizes. Results : No underdosing effect for 4-MV beam for fields larger than $5cm\times5cm$ was found For both 6- and 10-MV beams, the underdosing portion of the larynx at the distal surface was seen to occur for small fields, $4cm\times4cm\;and\;5cm\times5cm$. The underdosed tissue was increased in its volume with beam energy even for similar surface doses. The relative distal surface dose to maximum dose was changed to 0.99 from 0.95, 0.92, and 0.91 for 4-, 6-, and 10-MV, respectively, with increasing field size, $4cm\times4cm\;to\;8cm\times8cm$, For 6- and 10-MV beams, the dose at the surface of the cavity is measured less than the predicted by about two and three percent. respectively. but decrease was found for 4-MV beam for $5cm\times5cm$ field. For the $4cm\timesL\timesZ$ (height in cm). varying depth from 0.0 to 4.8cm, cavity, O/E> 1.0 was observed regardless of the cavity size for any field larger than about $8cm\times8cm$. Conclusion : The magnitude of underdosing depends on beam energy, field size. and cavity size for the larynx model. Based on the result of the study. caution must be used when a small field of a high quality x-ray beam is irradiated to regions including air cavities. and especially the region where the tumor extends to the surface. Low quality beam. such as. 4-MV x-ray, and larger fields can be used preferably to reduce the risk of underdosing, local failure. In the case of high quality beams such as 6- and 10-MV x-rays, however. an additional boost field is recommended to add for the compensation of the underdosing region when a typically used treatment field. $8cm\times8cm$, is employed.

  • PDF

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.

Medical Radiation Exposure Dose of Workers in the Private Study of the Job Function (의료기관 방사선 종사자의 직무별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.3-12
    • /
    • 2011
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: From January 1, 2010 December 31, 2010, medical practitioners working in the radiation is classified as a regular personal radiation dosimetry, and subsequently one year 540 people managed investigation department to target workers, dose sectional area, working period, identify the job function-related tasks for a deep dose, respectively, the annual average radiation dose were analyzed. Frequency analysis methods include ANOVA was performed. Results: Medical radiation workers in the department an annual radiation dose of Nuclear and 4.57 mSv a was highest, dose zone-specific distribution of nuclear medicine and in the 5.01~19.05 mSv in the high dose area distribution showed departmental radiation four of the annual radiation dose of Nuclear and 7.14 mSv showed the highest radiation dose. More work an average annual radiation dose according to the job function related to the synthesis of Cyclotron to 17.47 mSv work showed the highest radiation dose, Gamma camera Cinema Room 7.24 mSv, PET/CT Cinema Room service is 7.60 mSv, 2.04 mSv in order of intervention high, were analyzed. Working period, according to domain-specific average annual dose of radiation dose from 10 to 14 in oral and maxillofacial radiology practitioners as high as 1.01~3.00 mSv average dose showed the Department of Radiology, 1-4 years, 5-9 years, respectively, 1.01 workers~8.00 mSv in the range of the most high-dose region showed the distribution, nuclear medicine, and the 1-4 years, 5-9 years 3.01~19.05 mSv, respectively, workers of the highest dose showed the distribution of the area in the range of 10 to 14 years, Workers at 15-19 3.01~15.00 mSv, respectively in the range of the high-dose region were distributed. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

An Analysis on the Conditions for Successful Economic Sanctions on North Korea : Focusing on the Maritime Aspects of Economic Sanctions (대북경제제재의 효과성과 미래 발전 방향에 대한 고찰: 해상대북제재를 중심으로)

  • Kim, Sang-Hoon
    • Strategy21
    • /
    • s.46
    • /
    • pp.239-276
    • /
    • 2020
  • The failure of early economic sanctions aimed at hurting the overall economies of targeted states called for a more sophisticated design of economic sanctions. This paved way for the advent of 'smart sanctions,' which target the supporters of the regime instead of the public mass. Despite controversies over the effectiveness of economic sanctions as a coercive tool to change the behavior of a targeted state, the transformation from 'comprehensive sanctions' to 'smart sanctions' is gaining the status of a legitimate method to impose punishment on states that do not conform to international norms, the nonproliferation of weapons of mass destruction in this particular context of the paper. The five permanent members of the United Nations Security Council proved that it can come to an accord on imposing economic sanctions over adopting resolutions on waging military war with targeted states. The North Korean nuclear issue has been the biggest security threat to countries in the region, even for China out of fear that further developments of nuclear weapons in North Korea might lead to a 'domino-effect,' leading to nuclear proliferation in the Northeast Asia region. Economic sanctions had been adopted by the UNSC as early as 2006 after the first North Korean nuclear test and has continually strengthened sanctions measures at each stage of North Korean weapons development. While dubious of the effectiveness of early sanctions on North Korea, recent sanctions that limit North Korea's exports of coal and imports of oil seem to have an impact on the regime, inducing Kim Jong-un to commit to peaceful talks since 2018. The purpose of this paper is to add a variable to the factors determining the success of economic sanctions on North Korea: preventing North Korea's evasion efforts by conducting illegal transshipments at sea. I first analyze the cause of recent success in the economic sanctions that led Kim Jong-un to engage in talks and add the maritime element to the argument. There are three conditions for the success of the sanctions regime, and they are: (1) smart sanctions, targeting commodities and support groups (elites) vital to regime survival., (2) China's faithful participation in the sanctions regime, and finally, (3) preventing North Korea's maritime evasion efforts.

Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT (폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발)

  • Yoon, KyoungJun;Kwak, JungWon;Cho, ByungChul;Song, SiYeol;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.100-109
    • /
    • 2014
  • In stereotactic body radiotherapy (SBRT), the accurate location of treatment sites should be guaranteed from the respiratory motions of patients. Lots of studies on this topic have been conducted. In this letter, a new verification method simulating the real respiratory motion of heterogenous treatment regions was proposed to investigate the accuracy of lung SBRT for Volumetric Modulated Arc Therapy. Based on the CT images of lung cancer patients, lung phantoms were fabricated to equip in $QUASAR^{TM}$ respiratory moving phantom using 3D printer. The phantom was bisected in order to measure 2D dose distributions by the insertion of EBT3 film. To ensure the dose calculation accuracy in heterogeneous condition, The homogeneous plastic phantom were also utilized. Two dose algorithms; Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB) were applied in plan dose calculation processes. In order to evaluate the accuracy of treatments under respiratory motion, we analyzed the gamma index between the plan dose and film dose measured under various moving conditions; static and moving target with or without gating. The CT number of GTV region was 78 HU for real patient and 92 HU for the homemade lung phantom. The gamma pass rates with 3%/3 mm criteria between the plan dose calculated by AAA algorithm and the film doses measured in heterogeneous lung phantom under gated and no gated beam delivery with respiratory motion were 88% and 78%. In static case, 95% of gamma pass rate was presented. In the all cases of homogeneous phantom, the gamma pass rates were more than 99%. Applied AcurosXB algorithm, for heterogeneous phantom, more than 98% and for homogeneous phantom, more than 99% of gamma pass rates were achieved. Since the respiratory amplitude was relatively small and the breath pattern had the longer exhale phase than inhale, the gamma pass rates in 3%/3 mm criteria didn't make any significant difference for various motion conditions. In this study, the new phantom model of 4D dose distribution verification using patient-specific lung phantoms moving in real breathing patterns was successfully implemented. It was also evaluated that the model provides the capability to verify dose distributions delivered in the more realistic condition and also the accuracy of dose calculation.