• 제목/요약/키워드: Tapping test

검색결과 77건 처리시간 0.03초

외상후 스트레스 장애 환자의 신경인지기능 (Neurocognitive Functions in Posttraumatic Stress Disorder)

  • 김선국;이강준;이승환;남민;정영조
    • 생물정신의학
    • /
    • 제10권2호
    • /
    • pp.147-158
    • /
    • 2003
  • Objective:The differences of various neurocognitive functions, including attention, memory, motor function, and higher cognitive function were compared between PTSD patients and normal control subjects. Also, correlation with PTSD symptom severity and neurocognitive functions were evaluated between PTSD patients and normal control subjects. Method:We assessed the neurocognitive functions by computerized neurocognitive test(CNT) batteries. The visual continuous performance test(CPT) and digit span test, finger tapping test and Wisconsin card sorting test(WCST) were executed. The Impact of Event Scale-Revised(IES-R) was used in the evaluation of the severity of PTSD. Result:The PTSD patients showed significantly impaired neurocognitive performance in all of the items, compared with normal control subjects. The relation between impairment in neurocognitive functions and symptom severity showed significant correlations. Conclusion:These results imply that PTSD patients have impaired neurocognitive functions concerning with specific brain areas, especially the frontal area. For the thorough evaluation of further neurocognitive functions, more detailed evaluation items of neurocognitive functions and brain imaging studies are necessary in the future study.

  • PDF

공구파손감지용 비젼시스템의 NC실장에 관한 연구 (A Study on the NC Embedding of Vision System for Tool Breakage Detection)

  • 이돈진;김선호;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.369-372
    • /
    • 2002
  • In this research, a vision system for detecting tool breakage which is hardly detected by such indirect in-process measurement method as acoustic emission, cutting torque and motor current was developed and embedded into a PC-NC system. The vision system consists of CMOS image sensors, a slit beam laser generator and an image grabber board. Slit beam laser was emitted on the tool surface to separate the tool geometry well from the various obstacles surrounding the tool. An image of tool is captured through two steps of signal processing, that is, median filtering and thresholding and then the tool is estimated normal or broken by use of change of the centroid of the captured image. An air curtain made by the jetting high-pressure air in front of the lens was devised to prevent the vision system from being contaminated by scattered coolant, cutting chips in cutting process. To embed the vision system to a Siemens PC-NC controller 840D NC, an HMI(Human Machine Interface) program was developed under the Windows 95 operating system of MMC103. The developed HMI is placed in a sub window of the main window of 840D and this program can be activated or deactivated either by a soft key on the operating panel or M codes in the NC part program. As the tool breakage is detected, the HMI program emit a command for automatic tool change or send alarm to the NC kernel. Evaluation test in a high speed tapping center showed the developed system was successful in detection of the small-radius tool breakage.

  • PDF

우주 발사체 구조 요소의 비파피검사 (Nondestructive Inspection of Launch Vehicle Structural Components)

  • 공철원;윤종훈;박재성;은세원;장영순;이영무
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.331-337
    • /
    • 2009
  • 우주 발사체는 매우 높은 신뢰도의 경량구조가 필요하다. 비 파괴검사 방법 등을 이용한 구조 건전성 관리가 중요하다. 본 논문에서는 우주발사체의 제작 및 검사에 실제 사용되었던 비 파괴검사 사례 중 일부를 정리하였다. 검사 방법으로는 초음파, X-ray, tapping, 음향방출 등이 사용되었고, 하드웨어로는 페이로드 페어링, 고압탱크, 체결부 및 접합부 등을 대상으로 하였다. 페이로드 페어링에서는 샌드위치 미접착 검사의 정량적 기준을 제시하였고, 고압탱크는 내압 인증시험시 내압증가에 따른 음향방출 데이터를 정리하였다. 샌드위치 체결부에서는 음향방출 신호의 주파수 변화에 따른 파손모드를 분석하였고, 이종재료 접합 구조에서는 미접착부 초음파검사를 위한 표준시편을 제시하였다. 이러한 분석 및 기록은 발사체 시스템을 구성하여 어떠한 상황이 발생하여도 신속하게 판단할 수 있는 근거가 될 수 있으며 발사체 시스템의 신뢰도를 높여주는 역할을 한다.

휴대전화 파지방법이 엄지손가락의 운동학적 변인과 근활성도에 미치는 영향 (The Effect of Smartphone Holding Techniques on Kinematic Variables and Muscle Activities in the Thumb during Tapping Numbers)

  • 김동수;채원식;정재후;이행섭
    • 한국운동역학회지
    • /
    • 제24권3호
    • /
    • pp.301-308
    • /
    • 2014
  • The purpose of this study was to determine whether there are significant differences in kinematic variables and muscle activities of the thumb between two smartphone holding techniques. Twelve right handed university students(age $25.4{\pm}3.9yrs$, height $176.2{\pm}5.1cm$, weight $75.8{\pm}11.4kg$, hand length $19.2{\pm}1.1cm$) who have no musculoskeletal disorder were recruited as the subjects and had experience in using a smartphone for more than one year. Maximum joint angle, angular velocity, muscular activities were determined for each trial. For each dependent variable, paired t-test was used to determine whether there were significant differences between one hand (OH) and two hands ([TH], ${\rho}$ <.05). The results of this study showed that there were no significant differences between OH and TH in the maximum joint angle of the thumb. The angular velocity of each joint was not statistically significant between OH and TH. The statistical analysis revealed that the main effect of the smartphone holding conditions was significant in the peak normalized muscular activities of FDI and APL. Although smartphone holding technique doesn't affect on mobility and movement of the thumb joint, it may affect on active degree of the thumb and the upper extremity in directly and indirectly.

Neurobehavioral Tests for Occupational Screening의 타당도 평가 : 파킨슨병 환자들의 검사 성적 (Validation of Neurobehavioral Tests for Occupational Screening(NTOS) : results of patients of Parkinson's disease)

  • 이채용
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권3호
    • /
    • pp.577-584
    • /
    • 1997
  • 이 연구는 최근 개발된 컴퓨터를 이용한 정신운동 기능 검사법인 Neurobehavioral Tests fur Occupational Screening(NTOS)의 타당도 평가를 위해 시도되었다. 일개 종합병원 신경과에 등록된 파킨슨병 환자 12명과 신경독성물질에 폭로된 적이 없는 근로자 21명을 대상으로 NTOS의 단순반응시간 검사, 2가지 선택반응시간 검사, 양 손의 수지타진검사를 실시하였다. 평균 단순반응시간은 근로자군은 245 msec, 환자군은 378 msec였으며, 2가지 선택반응시간은 근로자군은 444 msec, 환자군은 671 msec 로 나타나 T 검정에서 유의한 차이를 보였다. 주로 쓰는 손의 수지타진검사는 68.6회를 나타내었고, 파킨슨병 환자군은 51.6회, 주로 쓰지 않는 손은 각각 60.9회, 43.1회로 유의한 차이를 보였다. 환자군과 근로자군의 연령과 학력차이를 통계적으로 보정하고 두군에서 차이가 나는지를 알아보기 위해 공분산분석을 실시한 결과, 단순반응시간, 선택반응시간, 수지타진이 유의한 결과를 보였다. 이상으로 볼 때, NTOS는 정신운동기능의 장애를 발견할 수 있는 도구라고 생각된다. 그러나 선택반응 시간 검사의 실수 횟수 같이 상대적으로 민감하지 못한 지표에 대한 고려가 필요하며, 혼란변수를 연구 설계에서 조정할 수 있는 큰 규모의 연구와 정신운동기능의 잠재적 장애를 보이는 집단에 대한 연구들이 추후에 있어야 할 것이다.

  • PDF

Comparison of Rheological Properties of Powder Chlorella sp. Cultivated in Fermentor and Pond

  • Kang, Ki-Rim;Lee, Chung-Yung-J.;Lee, Cherl-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • 제12권5호
    • /
    • pp.740-745
    • /
    • 2002
  • The current study was conducted to identify the differences in the rheological properties of Chlorella sp. powder cultured in a fermentor and in a pond-like environment. Cells. cultured in the same media were harvested and spray dried. The biomass yield from the fermentor culture was 4.7% (dry basis), while that from the pond was 4.3% (dry basis). Measurements of the loose bulk density, tapping test, Hausner's ratio, and compressibility test all revealed differences between the rheological properties of the Chlorella sp. from the two cultivation systems. Although both the fermentor and pond cultured Chlorella sp. showed the same angle of repose, the mean size of the cells was 2.26 $\mu\textrm{m}$ and 2.89 $\mu\textrm{m}$, respectively. The weight of the Chlorella sp. tablets cultured in the fermentor and pond was 0.663 g/tablet and 0.593 g/tablet, respectively, while the friability of the tablets was 21% and 41%, respectively. Observation by Transmission Electron Microscope (TEM) showed that the cell wall of the Chlorella sp. cultured in the fermentor was thinner and more spherical than that cultured in the pond, thereby providing the main characteristic rheological properties of the powder.

Association between Low-level Mercury Exposure and Neurobehavioral Functions in Korean Adults Living in a Coastal City

  • Kim, Rock Bum;Kim, Byoung-Gwon;Kim, Yu-Mi;Hong, Young-Seoub;You, Chang-Hun;Kim, Dae-Seon
    • Environmental Analysis Health and Toxicology
    • /
    • 제28권
    • /
    • pp.15.1-15.8
    • /
    • 2013
  • Objectives The aim of this study was to determine the association between low-level mercury exposure and neurobehavioral functions in adults living in coastal regions of Korea. Methods We selected 172 adults aged 20-65 years living in a city in the coastal region of Korea. A sociodemographic survey was conducted, mercury levels in the blood, urine, and hair were measured, and the associations according to computerized neurobehavioral tests were determined using univariate analysis. After adjustment for associated variables, a multivariate linear regression analysis was performed. Results The geometric mean mercury levels in the blood, urine, and hair were $5.41{\mu}g/L$ (range, $0.00-15.84{\mu}g/L$), $1.17{\mu}g/g$-creatinine (range, $0.00-32.86{\mu}g/g$-creatinine), and 1.37 mg/kg (range, 0.42-6.56 mg/kg), respectively. Variables that were associated with simple reaction time according to the neurobehavioral test results were age and urine mercury level. Variables associated with choice reaction time were the recent use of Korean traditional medicine and urine mercury level. Variables associated with the right-hand finger tapping speed test were age, gender, smoking behavior, education level, monthly household income, and urine mercury level. Variables associated with the left-hand finger tapping speed test were age, gender, education level, and urine mercury level. After adjustment for associated variables, there was no significant association between urine mercury level and simple reaction time (${\beta}=25.96$; p =0.47), choice reaction time (${\beta}=50.37$; p =0.32), or the number of left-hand finger taps (${\beta}=-1.54$; p =0.21). However, urine mercury level was significantly associated with the number of right-hand finger taps (${\beta}=-3.86$; p =0.01). Conclusions We found no evidence that low-level mercury exposure in adults is associated with deficits in neurobehavioral functions. A longer follow-up study is required to confirm this conclusion.

소형.대용량 Metalized Film Capacitor의 용접 오차 검출 개발 (A Welding Inspection of Small-sized Metalized Film Capacitor with Large Capacity)

  • 정원영;오춘석;유영기;임종설;이서영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.135-137
    • /
    • 2004
  • In this study we'll deal with the small-sized metalized film capacitors with large capacity which head have $5mm{\times}5mm{\times}2.5mm$ dimension. The lead wire is used to weld at both sides of capacitors. At that time the position gap between the welding machine and lead wire supplier would cause the welding error. Also, during the tapping processing of metalized film capacitors, the interval error among the capacitors, the length error of lead frame attached at the capacitors, and the straightness distortion of the lead frame could happen. As mentioned, four kinds of error parameters will be measured and analyzed by using the automatic visual inspection system that is implemented with CCD camera, optical parts, background lighting, and image processing algorithms. Finally we are able to achieve success rate above 99% to detect the welding faults of capacitors in the field test.

  • PDF

Comparison of the Standard Floor Impact Sound with Living Impact Source by Subjective Evaluation

  • Park, Hyeon Ku;Kim, Kyeong Mo;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.39-48
    • /
    • 2014
  • In the previous test, the verification of the standard floor impact source was carried out comparing the physical characteristics with living impact sources. The result was appeared the validation of the standard impact source was very low because of differences of physical characteristics. This study aims to evaluate annoyance and loudness of standard impact source which is used for the measurement of floor impact sound, and to compare the annoyance and loudness of living impact sources which are produced in real life. The impact sources considered are tapping machine, tire and impact ball as standard sources, and nine real sources which were chosen from the existing researches. The result showed differences of annoyance and loudness between standard impact sources and living impact sources, which means the standard impact sources may rate the performance of floor system inappropriately. In the future, the rating method should be examined how the standard impact sources are similar with real sources in the point of rating the performance of floor system.

$SF_6$ 가스절연변압기에서 권선의 섹션에 대한 절연내력 연구 (A Study on the Dielectric Strength in Section of Winding in SF6 Gas Transformer)

  • 허우행;하영식;홍정표;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.152-158
    • /
    • 2000
  • This paper deal with the experimental discussion about the impulse and AC dielectric strength of SF6 gas insulated transformer. Test sample is measured the dielectric breakdown voltage about modeling of the first and second section which is the weakest for surge voltage. The AC breakdown voltage is appeared 1.4 times than impulse breakdown voltage, so we can estimate that the impulse breakdown voltage is severe to AC breakdown voltage, and when the impulse is applied, in case of lmm tapping with Nomex paper, the characteristics of dielectric breakdown voltage is same to that in oil immersed transformer when SF6 gas pressure is 2.2kg/$cm^2$G.

  • PDF