• Title/Summary/Keyword: Tapping test

Search Result 77, Processing Time 0.033 seconds

Neurocognitive Functions in Posttraumatic Stress Disorder (외상후 스트레스 장애 환자의 신경인지기능)

  • Kim, Sun-Kook;Lee, Kang-Joon;Lee, Seung-Hwan;Nam, Min;Chung, Young-Cho
    • Korean Journal of Biological Psychiatry
    • /
    • v.10 no.2
    • /
    • pp.147-158
    • /
    • 2003
  • Objective:The differences of various neurocognitive functions, including attention, memory, motor function, and higher cognitive function were compared between PTSD patients and normal control subjects. Also, correlation with PTSD symptom severity and neurocognitive functions were evaluated between PTSD patients and normal control subjects. Method:We assessed the neurocognitive functions by computerized neurocognitive test(CNT) batteries. The visual continuous performance test(CPT) and digit span test, finger tapping test and Wisconsin card sorting test(WCST) were executed. The Impact of Event Scale-Revised(IES-R) was used in the evaluation of the severity of PTSD. Result:The PTSD patients showed significantly impaired neurocognitive performance in all of the items, compared with normal control subjects. The relation between impairment in neurocognitive functions and symptom severity showed significant correlations. Conclusion:These results imply that PTSD patients have impaired neurocognitive functions concerning with specific brain areas, especially the frontal area. For the thorough evaluation of further neurocognitive functions, more detailed evaluation items of neurocognitive functions and brain imaging studies are necessary in the future study.

  • PDF

A Study on the NC Embedding of Vision System for Tool Breakage Detection (공구파손감지용 비젼시스템의 NC실장에 관한 연구)

  • 이돈진;김선호;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.369-372
    • /
    • 2002
  • In this research, a vision system for detecting tool breakage which is hardly detected by such indirect in-process measurement method as acoustic emission, cutting torque and motor current was developed and embedded into a PC-NC system. The vision system consists of CMOS image sensors, a slit beam laser generator and an image grabber board. Slit beam laser was emitted on the tool surface to separate the tool geometry well from the various obstacles surrounding the tool. An image of tool is captured through two steps of signal processing, that is, median filtering and thresholding and then the tool is estimated normal or broken by use of change of the centroid of the captured image. An air curtain made by the jetting high-pressure air in front of the lens was devised to prevent the vision system from being contaminated by scattered coolant, cutting chips in cutting process. To embed the vision system to a Siemens PC-NC controller 840D NC, an HMI(Human Machine Interface) program was developed under the Windows 95 operating system of MMC103. The developed HMI is placed in a sub window of the main window of 840D and this program can be activated or deactivated either by a soft key on the operating panel or M codes in the NC part program. As the tool breakage is detected, the HMI program emit a command for automatic tool change or send alarm to the NC kernel. Evaluation test in a high speed tapping center showed the developed system was successful in detection of the small-radius tool breakage.

  • PDF

Nondestructive Inspection of Launch Vehicle Structural Components (우주 발사체 구조 요소의 비파피검사)

  • Kong, Cheol-Won;Youn, Jong-Hoon;Park, Jae-Sung;Eun, Se-Won;Jang, Young-Soon;Yi, Yeong-Moo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.331-337
    • /
    • 2009
  • Space launch vehicles require highly reliable, lightweight structures. It is thus important to monitor the structural health of these components with nondestructive inspections. In this paper, we studied an example of a nondestructive inspection that was partially applied to the manufacture and inspection of a launch vehicle. Ultrasonic tests, X-rays, tapping, and acoustic emissions comprised the inspection method. A payload fairing, high pressure tank, fastener part, and bonding part were used as hardware to be inspected. We proposed a quantitative standard for debonding inspection of the payload fairing and acoustic emission data for the proof test of the high pressure tank. We analyzed the fracture mode of the sandwich fastener part according to frequency changes. We also proposed a standard specimen for ultrasonic inspection of bonds of different materials. The present analyses and results provide data for evaluation of the launch operation sequence to ensure launch vehicles afford high reliability.

The Effect of Smartphone Holding Techniques on Kinematic Variables and Muscle Activities in the Thumb during Tapping Numbers (휴대전화 파지방법이 엄지손가락의 운동학적 변인과 근활성도에 미치는 영향)

  • Kim, Dong-Soo;Chae, Woen-Sik;Jung, Jae-Hu;Lee, Haeng-Seob
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.3
    • /
    • pp.301-308
    • /
    • 2014
  • The purpose of this study was to determine whether there are significant differences in kinematic variables and muscle activities of the thumb between two smartphone holding techniques. Twelve right handed university students(age $25.4{\pm}3.9yrs$, height $176.2{\pm}5.1cm$, weight $75.8{\pm}11.4kg$, hand length $19.2{\pm}1.1cm$) who have no musculoskeletal disorder were recruited as the subjects and had experience in using a smartphone for more than one year. Maximum joint angle, angular velocity, muscular activities were determined for each trial. For each dependent variable, paired t-test was used to determine whether there were significant differences between one hand (OH) and two hands ([TH], ${\rho}$ <.05). The results of this study showed that there were no significant differences between OH and TH in the maximum joint angle of the thumb. The angular velocity of each joint was not statistically significant between OH and TH. The statistical analysis revealed that the main effect of the smartphone holding conditions was significant in the peak normalized muscular activities of FDI and APL. Although smartphone holding technique doesn't affect on mobility and movement of the thumb joint, it may affect on active degree of the thumb and the upper extremity in directly and indirectly.

Validation of Neurobehavioral Tests for Occupational Screening(NTOS) : results of patients of Parkinson's disease (Neurobehavioral Tests for Occupational Screening의 타당도 평가 : 파킨슨병 환자들의 검사 성적)

  • Lee, Chae-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.577-584
    • /
    • 1997
  • Validation and Standardization of neurobehavioral instrument in Korean occupational setting has not been studied ever. This study tried to validate the newly developed computerized psychomotor tests, Neurobehavioral Tests for Occupational Screening (NTOS). Male patients with Parkinson's disease(n=12) and male workers who never exposed to occupational neurotoxic materials and didn't have neurologic disease(n=21), performed some tests from NTOS; simple reaction time, choice reaction time(2 choice), and finger tapping(both hands). In simple analysis, difference between patient group and worker group was significantly great. Adjusted for age and education years, simple reaction time and finger tapping(both hand) were statistically significantly different between two groups(p<.05). Choice reaction time was also different(p<.1) but error frequency of choice reaction time test was not. Generally, this results showed NTOS could detect impairment of psychomotor function. But insensitive results of choice reaction time was partly due to small sample size and confounding variables and so required future study and refinement at improvement of NTOS.

  • PDF

Comparison of Rheological Properties of Powder Chlorella sp. Cultivated in Fermentor and Pond

  • Kang, Ki-Rim;Lee, Chung-Yung-J.;Lee, Cherl-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.5
    • /
    • pp.740-745
    • /
    • 2002
  • The current study was conducted to identify the differences in the rheological properties of Chlorella sp. powder cultured in a fermentor and in a pond-like environment. Cells. cultured in the same media were harvested and spray dried. The biomass yield from the fermentor culture was 4.7% (dry basis), while that from the pond was 4.3% (dry basis). Measurements of the loose bulk density, tapping test, Hausner's ratio, and compressibility test all revealed differences between the rheological properties of the Chlorella sp. from the two cultivation systems. Although both the fermentor and pond cultured Chlorella sp. showed the same angle of repose, the mean size of the cells was 2.26 $\mu\textrm{m}$ and 2.89 $\mu\textrm{m}$, respectively. The weight of the Chlorella sp. tablets cultured in the fermentor and pond was 0.663 g/tablet and 0.593 g/tablet, respectively, while the friability of the tablets was 21% and 41%, respectively. Observation by Transmission Electron Microscope (TEM) showed that the cell wall of the Chlorella sp. cultured in the fermentor was thinner and more spherical than that cultured in the pond, thereby providing the main characteristic rheological properties of the powder.

Association between Low-level Mercury Exposure and Neurobehavioral Functions in Korean Adults Living in a Coastal City

  • Kim, Rock Bum;Kim, Byoung-Gwon;Kim, Yu-Mi;Hong, Young-Seoub;You, Chang-Hun;Kim, Dae-Seon
    • Environmental Analysis Health and Toxicology
    • /
    • v.28
    • /
    • pp.15.1-15.8
    • /
    • 2013
  • Objectives The aim of this study was to determine the association between low-level mercury exposure and neurobehavioral functions in adults living in coastal regions of Korea. Methods We selected 172 adults aged 20-65 years living in a city in the coastal region of Korea. A sociodemographic survey was conducted, mercury levels in the blood, urine, and hair were measured, and the associations according to computerized neurobehavioral tests were determined using univariate analysis. After adjustment for associated variables, a multivariate linear regression analysis was performed. Results The geometric mean mercury levels in the blood, urine, and hair were $5.41{\mu}g/L$ (range, $0.00-15.84{\mu}g/L$), $1.17{\mu}g/g$-creatinine (range, $0.00-32.86{\mu}g/g$-creatinine), and 1.37 mg/kg (range, 0.42-6.56 mg/kg), respectively. Variables that were associated with simple reaction time according to the neurobehavioral test results were age and urine mercury level. Variables associated with choice reaction time were the recent use of Korean traditional medicine and urine mercury level. Variables associated with the right-hand finger tapping speed test were age, gender, smoking behavior, education level, monthly household income, and urine mercury level. Variables associated with the left-hand finger tapping speed test were age, gender, education level, and urine mercury level. After adjustment for associated variables, there was no significant association between urine mercury level and simple reaction time (${\beta}=25.96$; p =0.47), choice reaction time (${\beta}=50.37$; p =0.32), or the number of left-hand finger taps (${\beta}=-1.54$; p =0.21). However, urine mercury level was significantly associated with the number of right-hand finger taps (${\beta}=-3.86$; p =0.01). Conclusions We found no evidence that low-level mercury exposure in adults is associated with deficits in neurobehavioral functions. A longer follow-up study is required to confirm this conclusion.

A Welding Inspection of Small-sized Metalized Film Capacitor with Large Capacity (소형.대용량 Metalized Film Capacitor의 용접 오차 검출 개발)

  • Jeong, Won-Young;Oh, Choon-Suk;Ryu, Young-Kee;Lim, Jong-Seul;Lee, Seo-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.135-137
    • /
    • 2004
  • In this study we'll deal with the small-sized metalized film capacitors with large capacity which head have $5mm{\times}5mm{\times}2.5mm$ dimension. The lead wire is used to weld at both sides of capacitors. At that time the position gap between the welding machine and lead wire supplier would cause the welding error. Also, during the tapping processing of metalized film capacitors, the interval error among the capacitors, the length error of lead frame attached at the capacitors, and the straightness distortion of the lead frame could happen. As mentioned, four kinds of error parameters will be measured and analyzed by using the automatic visual inspection system that is implemented with CCD camera, optical parts, background lighting, and image processing algorithms. Finally we are able to achieve success rate above 99% to detect the welding faults of capacitors in the field test.

  • PDF

Comparison of the Standard Floor Impact Sound with Living Impact Source by Subjective Evaluation

  • Park, Hyeon Ku;Kim, Kyeong Mo;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.39-48
    • /
    • 2014
  • In the previous test, the verification of the standard floor impact source was carried out comparing the physical characteristics with living impact sources. The result was appeared the validation of the standard impact source was very low because of differences of physical characteristics. This study aims to evaluate annoyance and loudness of standard impact source which is used for the measurement of floor impact sound, and to compare the annoyance and loudness of living impact sources which are produced in real life. The impact sources considered are tapping machine, tire and impact ball as standard sources, and nine real sources which were chosen from the existing researches. The result showed differences of annoyance and loudness between standard impact sources and living impact sources, which means the standard impact sources may rate the performance of floor system inappropriately. In the future, the rating method should be examined how the standard impact sources are similar with real sources in the point of rating the performance of floor system.

A Study on the Dielectric Strength in Section of Winding in SF6 Gas Transformer ($SF_6$ 가스절연변압기에서 권선의 섹션에 대한 절연내력 연구)

  • Heo, U-Haeng;Ha, Yeong-Sik;Hong, Jeong-Pyo;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.152-158
    • /
    • 2000
  • This paper deal with the experimental discussion about the impulse and AC dielectric strength of SF6 gas insulated transformer. Test sample is measured the dielectric breakdown voltage about modeling of the first and second section which is the weakest for surge voltage. The AC breakdown voltage is appeared 1.4 times than impulse breakdown voltage, so we can estimate that the impulse breakdown voltage is severe to AC breakdown voltage, and when the impulse is applied, in case of lmm tapping with Nomex paper, the characteristics of dielectric breakdown voltage is same to that in oil immersed transformer when SF6 gas pressure is 2.2kg/$cm^2$G.

  • PDF