• Title/Summary/Keyword: Tapping Noise

Search Result 34, Processing Time 0.022 seconds

Delamination detection in composite laminates using tapping test and wavelet transform (태핑시험과 웨이블릿 변환을 이용한 복합적층판의 층간분리 검출)

  • Kim, Sung Joon;Hwang, In Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.214-215
    • /
    • 2013
  • The tapping test has simplicity of procedure for detection of the damage in aircraft structure. However, the result of tapping test depends on the subjective experience of inspector. In this paper, more objective tapping test has proposed. The impact force histories and tapping sounds are used as reference data to evaluate the delamination. The WT(wavelet transform) is used to decompose the test data. From the results, we could know that high frequency components of force and sound are reduced due to delamination in composite laminate. On these results, the tapping force and sound caused by tapping could be used for the reference data to evaluate the delamination in composite structure.

  • PDF

Psvchoacoustical Evaluation of Floor Impact Noise (바닥충격음의 심리음향학적 평가)

  • 전진용;정정호;조문재
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.253-258
    • /
    • 2001
  • Floor impact noises in apartment buildings have been investigated as they are most annoying in living environment. Several experiments were undertaken to compare perceived noisiness of floor impact noises generated by bang and tapping machine along with children's jumping and running. Results show that bang noise is more annoying than tapping noise and floor impact noise generated by children is less annoying than the noise generated by machine. The floor impact noise generated by children's jumping and running corresponds well with the bang-machine noise in terms of loudness, unbiased annoyance, ${\Phi}$$\_$0/ and IACC. The noise generated by children is somewhat different from machine noise; in spatial impression the real noise is similar to tapping-machine noise but is less annoying that the machine noises.

  • PDF

Proper Orthogonal Mode Analysis of AFM Microcantilevers in Dynamic Mode (동적모드 AFM 마이크로캔틸레버의 적합직교모드 해석)

  • Cho, Hong-Mo;Lee, Soo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.606-611
    • /
    • 2007
  • Proper orthogonal decomposition (POD) is a method for extracting bases for modal decomposition from the ensemble of dynamic signals. Using the POD method, we analyzed the proper orthogonal modes (POMs) of AFM microcantilevers in dynamic mode operations such as Tapping Mode. The POMs and POVs (proper orthogonal values) were computed through MATLAB simulation for the 5-mode model of the microcantilever. We found that the POV portion of the higher POMs of the tapping microcanilever slightly increased in comparison with no tapping. This implies that the modal energy in the fundamental mode can be transferred to the higher modes during tapping.

  • PDF

Nanoscale Nonlinear Dynamics of Carbon Nanotube Probe Tips (탄소나노튜브 탐침의 나노 비선형 동역학)

  • 이수일
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.83-86
    • /
    • 2004
  • Carbon nanotube (CNT) tips in tapping mode atomic force microscopy (AFM) enable very high-resolution imaging, measurements, and manipulation at the nanoscale. We present recent results based on experimental analysis that yield new insights into the dynamics of CNT probe tips in tapping mode AFM. Experimental measurements are presented of the frequency response and dynamic amplitude-distance data of a high-aspect-ratio multi-walled (MW) CNT tip to demonstrate the non-linear features including tip amplitude saturation preceding the dynamic buckling of the MWCNT. Surface scanning is performed using a MWCNT tip on a SiO$_2$ grating to verify the imaging instabilities associated with MWCNT buckling when used with normal control schemes in the tapping mode. Lastly, the choice of optimal setpoints for tapping mode control using CNT probe tip are discussed using the experimental results.

  • PDF

Vibration Analysis of the Tapping AFM Microcantilevers Using Proper Orthogonal Decomposition (적합직교분해법을 이용한 AFM 마이크로캔틸레버의 진동해석)

  • Hong, Sang-Hyuk;Lee, Soo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.4
    • /
    • pp.414-421
    • /
    • 2010
  • The proper orthogonal decomposition(POD) is used to the vibration analysis of microcantilever in tapping mode atomic force microscopy(AFM). The proper orthogonal modes (POM) are extracted from vibrating signals of microcantilever when it resonates and taps the sample. We present recent ideas based on POD and detailed experiments that yield new perspectives into the microscale structures such as the tapping cantilever. The linearized modeling technique based on POD is very useful to show the principal characteristics of the complex dynamic responses of the AFM microcantilever.

Nonlinear Dynamics at the Nanoscale (나노스케일에서의 비선형 동역학)

  • Lee, Soo-Il;Hong, Sang-Hyuk;Park, Jun-Hyung;Lee, Jang-Moo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.125-128
    • /
    • 2004
  • AFM(Atomic Force Microscope) becomes a versatile tool in the nanoscale measurements and processes. Especially the tapping mode is a very useful mode in AFM operation to measure and process at the nanoscale. Although the tapping mode has a great potential for the novel techniques such as phase imaging, however, it is not clearly known the fundamental mechanics affected by complex tip-sample interactions. This paper shows the various nonlinear dynamic features in tapping mode AFM microcantilevers including hysteretic jumps and period doublings of the microcantilevers. Also it is discussed the complex dynamics of CNT(Carbon Nanotube) probes and the opportunities on the nanoscale nonlinear dynamics.

  • PDF

A Study on the Chattering Phenomena of a Check Valve (역지밸브 채터링 현상 해소방안 연구)

  • 유기완;이준신;김태룡
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.1
    • /
    • pp.36-41
    • /
    • 2002
  • The cause and the elimination method for the chattering phenomena were investigated in a check valve attached to the exit of an auxiliary cooling water pump in a Korean nuclear powerplant. From the site experiment and the numerical calculation, the incident angle of the disk was so small that it was not able to produce the sufficient lifting force to overcome the gravitational component of the disk weight. Moreover, it turned out that the installation position was not symmetric for the secondary vortical flow generated inside the elbow so that the flow structure had strongly unstable flow characteristics. From this study, the tapping noise and the chattering phenomena were eliminated exactly by changing the incidence angle of the valve disk and the installation position of the calve body.

Comparison of Standard Floor Impact Sources with a Human Impact Source (바닥충격음 측정용 표준충격원과 실충격원의 특성 비교)

  • Lee, Pyoung-Jik;Jeong, Jeong-Ho;Park, Jun-Hong;Jeon, Jin-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.8 s.113
    • /
    • pp.789-796
    • /
    • 2006
  • The characteristics of the four standard floor impact sources (impact ball, bang machine, tapping machine, modified tapping machine) and a human impact source (jumping children) were investigated. First, the mechanical impedance of each source were evaluated. Then, the impact force exposure level of each source were measured. The results showed that fundamental frequency and impedance produced by the impact ball are the most similar to those of the human impact source. The frequency characteristics of the impact ball were most similar to those of jumping children. Consequently, the impact ball more accurately reproduces human impact compared to the other standard impact sources. Therefore, the impact ball should be considered as the reliable impactor in evaluating floor impact noise.