• Title/Summary/Keyword: Tapered

Search Result 905, Processing Time 0.027 seconds

A STUDY ON THE ADAPTATION OF LIGHT-CURED AND SELF-CURED GLASS-IONOMER CEMENTS TO TOOTH STRUCTURE (광중합형과 자가중합형 글라스 아이오노머 시멘트의 변연 접합성에 관한 연구)

  • Park, Yil-Yoon;Cho, Young-Gon;Hur, Seung-Myun
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.148-158
    • /
    • 1994
  • The purpose of this study was to compare the adaptation to tooth structure of light - cured glass ionomer cement with that of self -cured glass ionomer cement. In this study, class V cavities were prepared on the buccal surfaces of 10 extracted human premolar teeth, and teeth were randomly assigned 2 groups of 5 teeth each. The cavities of self-curing glass ionomer cement group were restored with the Fuji n. and the cavities of lightcuring glass ionomer cement group were restored with the Fuji II LC. The surfaces of glass ionomer cements were applied with All-Bond 2 adhesive, and cured with visible light. The restored teeth were stored in 100% relative humidity at $37^{\circ}C$ for 24 hours. And then. the roots of the teeth were removed with the tapered fissure bur and the remaining crowns were sectioned occlusogingivally through the center of glass ionomer restorations. Adaptation at tooth-restoration interface was assessed occlusally. axially, and gingivally by scanning electron microscope. The results were as follows : 1. On the occlusal margin, the group of self - curing glass ionomer cement showed closer adaptation to both enamel and dentin than the group of light-curing glass ionomer cement showing 5/lm gap between cement and tooth structure. 2. On the axial wall. the group of light-curing glass ionomer cement showing 5-$7{\mu}m$ gap between cement and dentin showed closer adaptation to dentin than the group of self -curing glass ionomer cement showing 10-$15{\mu}m$ gap between cement and dentin. 3. On the gingival margin, the group of light-curing glass ionomer cement showing 2-$5{\mu}m$ gap between cement and dentin(X 1200) showed closer adaptation to dentin than the group of self-curing glass ionomer cement showing 20pm gap between cement and dentin(X 600). 4. The group of self -curing glass ionomer cement showed closer adaptation on the occlusal margin than on the gingival margin, and the group of light-curing glass ionomer cement showed similar adaptation on both occlusal and gingival margins.

  • PDF

Hemipelvectomy in a Cat with Obstipation (심한 변비를 보이는 고양이에서 반골반절제술을 이용한 외과적 치료 증례)

  • Yoon, Hun-Young;Kim, Kyung-Hee;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.30 no.2
    • /
    • pp.119-122
    • /
    • 2013
  • A 9-month-old female Korean short hair cat weighing 2.2 kg presented for evaluation of a two-week history of obstipation. The owner reported that the cat sustained pelvic fractures 4 months previous to the onset of fecal tenesmus. On physical examination, fecal tenesmus was observed and restriction of the movement of the right coxofemoral joint was evident. Rectal palpation revealed narrowing of the pelvic canal with a hard bony protuberance at the bilateral acetabulum and pubic bones. Radiographs revealed a distended colon with feces and narrowing of the pelvic canal with abnormal structure of the pelvic bone. Conservative management consisting of stool softeners and a warm water enema was instituted; however, there was no improvement in obstipation. Partial iliac, ischial, pubic, and acetabular ostectomies were performed. Postoperative radiographs and rectal palpation revealed the enlarged pelvic canal. Stool softeners (5 ml orally twice daily) was administered following surgery for 14 days and then tapered down to 2.5 ml for 14 days. A warm water enema was performed twice postoperatively. At examination 14 days postoperatively, no problems with defecation and gait were reported. There was no evidence of obstipation and lameness of the left pelvic limb 5 months postoperatively.

SEM EVALUATION OF THE PREPARED ROOT CANALS BY HAND AND Ni-Ti ROTARY ROOT CANAL INSTRUMENTS (Hand & rotary root canal instrument의 근관내 삭제 형태에 관한 전자현미경적 비교)

  • Oh, Tae-Seok;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.477-486
    • /
    • 1998
  • Recently the development of rotary instrument makes it possible that in root canal treatment operator saves much more time, maintans original curved canal shape and easily prepares continuous tapered root canal. The purpose of this experiment was to examine the smoothness of the internal surface of prepared root canal and the effectiveness of debridement in prepared root canal by SEM for the comparison of hand and Ni-Ti rotary instrument. 25 extracted human teeth were access opened and # 10 K-type file was introduced into canal until it was appeared at the apical foramen. The working length was established by subtracting 0.5mm from this measurement. Group 1. The root canal preparation was done to # 30 with working length and then step-back until # 45 with K-Flexofile (Maillefer, Swiss). Group 2. Root canal preparation was done by Naviflex Ni-Ti file (Brasseler, USA) as the same technique with group 1. Group 3. Canal was prepared by Profile .04 (Maillefer, Swiss) taper until #30. Group 4. With use of Quantec (Tycom, USA) root canal was prepared from file number 1 to 8. In group 1 and 2, the root canal irrigant was NaOCl and the other groups, NaOCl and RC-prep (Premine Dental Products, USA) was used. The prepared teeth were notched with high-speed bur as bucco-lingual direction and fractured with chisel and mallet, then examined with SEM. Group 1 showed smooth internal surface. There were scratches mainly to the axial direction. Group 2 showed similar characteristics to those in group 1. Group 3 showed more smoother and linear cutting surface with bised scratches. Group 4 has the almost same characteristics group 3 and there was no difference in the file design. Ni-Ti rotary root canal instrument prepare the dentinal wall more smoother than hand instrument. The effectiveness of debridement was not fully affected by file design. The isthmus area and accessory canals of the root canal system were not prepared in any group. According to the result, hand and rotary type instrumentation techniques were effective in removal of major amount of tissue from root canal but it was not complete. In the direction of cutting movement there was difference between them.

  • PDF

Development of UHF Band Tag Antenna using Radio Frequency Identification Multipurpose Complex Card (RFID 다기능 복합 카드용 UHF 대역 소형 태그 안테나 개발)

  • Byun, Jong-Hun;Sung, Bong-Geun;Choi, Eun-Jung;Ju, Dae-Geun;Yoo, Dae-Won;Cho, Byung-Lok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12B
    • /
    • pp.1452-1458
    • /
    • 2009
  • In this paper, Our proposed Multipurpose Complex Card UHF band RFID small-size Tag antenna. Multi purpose Complex Card UHF band RFID small-size Tag antenna that is to minimize the low efficiency of RFID Tag Read Range that generates space limitation and a conductor surrounded by inducing fingerpring system with dual(HF, UHF) Card is presented. Our proposed UHF band RFID small-size Tag antenna is for the Multipurpose Complex Card that is mounted on the fingerpring system as well as the HF Tag. It also enables to minimize and facilitates Tag chip matching by adjusting Tapered, Meander line and Loop structure. Given the card substance properties and periphery circuit, the proposed small-size Tag antenna, in this report, is designed with PET film with size of $50{\times}15mm^2$. The RFID small-size Tag method for measurements is used by EPCglobal Static Test instrument in Anechoic Chamber, which is tested with dual Card, within the car and in wallet. It is found that Read Range is 3.8m from the EPCglobal Static Test, Maximum Read Range within the car from the field test results in 7.6m. Proposed Tag antenna is will be used in the parking control security system.

Identification of Infectious Fungus in the Artificial Cultivation Rooms of Paecilomyces tenuipes (눈꽃동충하초 재배상 내에 발생된 오염균의 동정)

  • 남성희;정이연;홍인표;지상덕;장승종;한명세
    • Journal of Sericultural and Entomological Science
    • /
    • v.45 no.2
    • /
    • pp.108-111
    • /
    • 2003
  • A infectious fungus (J131) recently isolated from artificial cultivation farms of Paecilomyces tenuipes is known to cause a great yield loss and deterioration of products. In this study, its occurrence and characterization were made. The isolate (J131) was identified as Paecilomyces farinosus (Holm ex S. F. Gray) Brown & Smith. Colonies of the isolate on PDA grew moderately fast, attaining a diameter of 19mm within 14 days at 24${\pm}$1$^{\circ}C$. Vegetative hyphae are smooth-walled and hyaline. Conidiophores mainly arose from the submerged mycelium, usually measuring 1.3-1.5$\mu\textrm{m}$ wide and consisted of verticillate branches with whorls of 2 to 4 phialides. Phialides of 3.8-5.8${\times}$1.5-1.8 $\mu\textrm{m}$, with a swollen basal portion tapered into a distinct neck of about 0.6-0.8 $\mu\textrm{m}$ wide. Conidia arisen from the phialides, were ellipsoidal to fusiform, smooth-walled, hyaline, 1.8-2.4${\times}$1.1-1.4$\mu\textrm{m}$. .When silkworm larvae were injected with concentration of 1${\times}$10$\^$8/ conidia/$m\ell$ of infectious fungus J131, infection rate was 41.3% and synnemata formation rate was 23.6%. Black spots were appeared on the surface of silkworm larvae in 5-9 days after injection. The surface of larvae was covered with hyphae which were gradually turned into yellow from white color during the incubation period of 3-4 days. 1 to several 4-6mm long synnemata of yellow or orange color were formed on the surface. The matured synnemata were ramified from its end and produced much conidia of white color.

Stiffness Enhancement of Piecewise Integrated Composite Robot Arm using Machine Learning (머신 러닝을 이용한 PIC 로봇 암 강성 향상에 대한 연구)

  • Ji, Seungmin;Ham, Seokwoo;Cheon, Seong S.
    • Composites Research
    • /
    • v.35 no.5
    • /
    • pp.303-308
    • /
    • 2022
  • PIC (Piecewise Integrated Composite) is a new concept for designing a composite structure with mosaically assigning various types of stacking sequences in order to improve mechanical properties of laminated composites. Also, machine learning is a sub-category of artificial intelligence, that refers to the process by which computers develop the ability to continuously learn from and make predictions based on data, then make adjustments without further programming. In the present study, the tapered box beam type PIC robot arm for carrying and transferring wide and thin LCD display was designed based on the machine learning in order to increase structural stiffness. Essential training data were collected from the reference elements, which were intentionally designated elements among finite element models, during preliminary FE analysis. Additionally, triaxiality values for each finite element were obtained for judging the dominant external loading type, such as tensile, compressive or shear. Training and evaluating machine learning model were conducted using the training data and loading types of elements were predicted in case the level accuracy was fulfilled. Three types of stacking sequences, which were to be known as robust toward specific loading types, were mosaically assigned to the PIC robot arm. Henceforth, the bending type FE analysis was carried out and its result claimed that the PIC robot arm showed increased stiffness compared to conventional uni-stacking sequence type composite robot arm.

An Experimental Study of Demountable Bolted Shear Connectors for the Easy Dismantling and Reconstruction of Concrete Slabs of Steel-Concrete Composite Bridges (강합성 교량의 콘크리트 바닥판 해체 및 재시공이 용이한 분리식 볼트접합 전단연결재에 관한 실험적 연구)

  • Jung, Dae Sung;Park, Se-Hyun;Kim, Tae Hyeong;Kim, Chul Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.751-762
    • /
    • 2022
  • Welded head studs are mainly used as shear connectors to bond steel girders and concrete slabs in steel-concrete composite bridges. For welded shear connectors, environmental problems include noise and scattering dust which are generated during the removal of damaged or aged slabs. Therefore, it is necessary to develop demountable shear connectors that can easily replace aged concrete slabs for efficient maintenance and thus for better management of environmental problems and life cycle costs. The buried nut method is commonly studied in relation to bolted shear connectors, but this method is not used in civil structures such as bridges due to low rigidity, low shear resistance, and increased initial slip. In this study, in order to mitigate these problems, a demountable bolted shear connector is proposed in which the buried nut is integrated into the stud column and has a tapered shape at the bottom of an enlarged column shank. To verify the performance of the proposed demountable stud bolts in terms of static shear strength and slip displacement, a horizontal shear test was conducted, with the performance outcomes compared to those of conventional welded studs. It was confirmed that the proposed demountable bolted shear connector is capable of excellent shear performance and that it satisfies the slip displacement and ductility design criteria, meaning that it is feasible as a replacement for existing welding studs.

Protein Requirement Changes According to the Treatment Application in Neurocritical Patients

  • Jungook Kim;Youngbo Shim;Yoon-Hee Choo; Hye Seon Kim; Young ran Kim; Eun Jin Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.4
    • /
    • pp.451-457
    • /
    • 2024
  • Objective : Exploring protein requirements for critically ill patients has become prominent. On the other hand, considering the significant impact of coma therapy and targeted temperature management (TTM) on the brain as well as systemic metabolisms, protein requirements may plausibly be changed by treatment application. However, there is currently no research on protein requirements following the application of these treatments. Therefore, the aim of this study is to elucidate changes in patients' protein requirements during the application of TTM and coma therapy. Methods : This study is a retrospective analysis of prospectively collected data from March 2019 to May 2022. Among the patients admitted to the intensive care unit, those receiving coma therapy and TTM were included. The patient's treatment period was divided into two phases (phase 1, application and maintenance of coma therapy and TTM; phase 2, tapering and cessation of treatment). In assessing protein requirements, the urine urea nitrogen (UUN) method was employed to estimate the nitrogen balance, offering insight into protein utilization within the body. The patient's protein requirement for each phase was defined as the amount of protein required to achieve a nitrogen balance within ±5, based on the 24-hour collection of UUN. Changes in protein requirements between phases were analyzed. Results : Out of 195 patients, 107 patients with a total of 214 UUN values were included. The mean protein requirement for the entire treatment period was 1.84±0.62 g/kg/day, which is higher than the generally recommended protein supply of 1.2 g/kg/day. As the treatment was tapered, there was a statistically significant increase in the protein requirement from 1.49±0.42 to 2.18±0.60 in phase 2 (p<0.001). Conclusion : Our study revealed a total average protein requirement of 1.84±0.62 g during the treatment period, which falls within the upper range of the preexisting guidelines. Nevertheless, a notable deviation emerged when analyzing the treatment application period separately. Hence, it is recommended to incorporate considerations for the type and timing of treatment, extending beyond the current guideline, which solely accounts for the severity by disease.

A study of the arch length discrepancy and the diagnostic analysis (치열궁내 공간 부조화와 진단적 평가에 관한 연구)

  • Ryu, Young-Kyu;Ahn, Kwang-Seok
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.1-11
    • /
    • 2004
  • Predicting the arch length discrepancy by simply comparing the available arch perimeter with tooth materials is merely a 2-dimensional analysis of the teeth movement. However, the real teeth movement takes place 3-dimensionally and is affected by various factors such as, the arch fen the curve of Spee and the axis of the incisors. The purpose of this study is to clarify the relationship between the decrease in the arch perimeter and the horizontal positional change of the incisors after extraction of the 1st bicuspids, for more analytic evaluation of the arch length discrepancy at pre-treatment model analysis stage. In addition to that to evaluate the effect of the curve of Spee, teeth axis to the basal plane, and the incisional crowding to the treatment outcome. All patients were treated at the department of orthodontics, dental hospital, Yonsei university. Inclusion criteria for patients selection were as follows. $\cdot$ Angle classification I malocclusion with bialveolar protrusion $\cdot$ Extraction of 4 1st bicuspids $\cdot$ No tooth anomaly or prosthesis $\cdot$ No abnormal attrition $\cdot$ No ectopically erupted teeth $\cdot$ Angle classification I canine and molar relationship $\cdot$ Less than 3mm of crowding Model analysis of the above patients was performed and the following conclusions were obtained. 1. When the intercanine distance was maintained, the available space for the distal movement of the mandibular incisors after the extraction of the 4 1st bicuspids was larger than the space provided by the extraction of the 4 1st bicuspids. However the difference was less than 1mm. The more tapered the anterior arch form, the larger the difference. 2. Compared to the situation in which the intercanine distance was maintained, when the intercanine distance was expanded to meet the width of the Posterior teeth, the incisors could move about 3mm more distally. 3. The positional difference of the incisal tip was insignificant whether the central incisors were moved by tipping or bodily movement. 4. When the anterior crowding was solved without changing the intercanine distance, the larger the anterior arch length was, the more the anterior movement of the incisors. 5. When the curve of Spee was levelled, the increase in the arch perimeter was less than half of the deepest curve of Spee.

Mechanical analysis of the taper shape and length of orthodontic mini-implant for initial stability (교정용 미니임플랜트의 초기 안정성에 대한 원추형태와 길이에 관한 기계역학적 분석)

  • Kim, Jong-Wan;Cho, Il-Sik;Lee, Shin-Jae;Kim, Tae-Woo;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.55-62
    • /
    • 2006
  • Orthodontic mini-implants, despite its usefulness as anchorage, have some limits such as loosening. Therefore, various shapes and lengths have been studied. The aim of this study is to analyze the shape and length of mini-implants mechanically. The shapes of mini-implants (1.6 mm, Dual Top, Jeil Medical Co., Seoul, Korea) were cylindrical and taper. The lengths of mini-implants were 6 mm and 8 mm. The tested groups were 5 groups (cylindrical 6 mm, cylindrical 8 mm, taper 6 mm, taper 8 mm and taper 8 mm modified whose thread is reduced from the middle to upper part). All were inserted and removed on the polyurethane foam with the torque measured. During insertion and removal, the taper shape needed higher torque than the cylindrical shape, and the 8 mm length than the 6 mm length (p<0.001). The taper 6mm group showed superior insertion torque (p<0.001) and similar removal torque to the cylindrical 8 mm group. The taper 8 mm modified group with gradually reduced threads, showed continuous high removal torque after the peak. The initial mechanical stability can be provided by the tapered shape and also, affected by length and thread design.