• Title/Summary/Keyword: Tapered

Search Result 905, Processing Time 0.026 seconds

Effect of Die Geometry on Expansion of Corn Flour Extrudate (사출구 구조에 따른 옥수수가루 압출성형물의 팽화특성)

  • Gu, Bon-Jae;Ryu, Gi-Hyung
    • Food Engineering Progress
    • /
    • v.15 no.2
    • /
    • pp.148-154
    • /
    • 2011
  • The objective of this study was to determine the effect of die geometry on expansion index of extruded corn flour. Water solubility index, water absorption index and specific mechanical energy (SME) input were analyzed to observe the relationship with die geometry. The feed moisture content was 20 and 25%. Die dimensions were tapered angle (57, 95o) and length/diameter (L/D) ratio of die land (0.67, 1.67 and 2.67). The SME input was the highest at 20% moisture content and 2.23E-10 m3 die constant. The sectional and volumetric expansion indices at 20% moisture were increased with increase in die constant. However, die constant did not influence sectional expansion index of corn flour extrudate at 25% moisture content. The extruded corn flour at 25% moisture content had higher longitudinal expansion index than those of extruded corn flour at 20% moisture content. Sectional expansion and longitudinal expansion index were negatively correlated. The water absorption index and water solubility index were not affected with the die constant.

Psychotic Symptoms of Hashimoto's Encephalopathy: A Diagnostic Challenge

  • Savarimuthu, Monisha K;Tsheringla, Sherab;Mammen, Priya
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.30 no.1
    • /
    • pp.42-44
    • /
    • 2019
  • Hashimoto's encephalopathy (HE) is a rare and underdiagnosed neuropsychiatric illness. We present the case of a 17-year-old girl who was admitted to a tertiary-care psychiatric center with acute onset psychosis and fever. Her psychotic symptoms were characterized by persecutory and referential delusions, as well as tactile and visual hallucinations. Her acute behavioral disturbance warranted admission and treatment in a psychiatric setting (risperidone tablets, 3 mg/day). She had experienced an episode of fever with a unilateral visual acuity defect approximately 3 years before admission, which was resolved with treatment. Focused clinical examination revealed an enlarged thyroid, and baseline blood investigations, including thyroid function test results were normal. Abnormal laboratory investigations revealed elevated anti-thyroid peroxidase (anti-TPO) and anti-thyroglobulin (anti-TG) levels (anti-TPO of 480 IU/mL; anti-TG of 287 IU/mL). Results of other investigations for infection, including cerebrospinal fluid examination, electroencephalography, and brain magnetic resonance imaging were normal. She was diagnosed with HE and was treated with intravenous corticosteroids (methylprednisolone up to 1 g/day; tapered and discontinued after a month). The patient achieved complete remission of psychotic symptoms and normalization of the anti-thyroid antibody titers. Currently, at the seventh month of follow-up, the patient is doing well. This case highlights the fact that in the absence of well-defined clinical diagnostic criteria, a high index of suspicion is required for early diagnosis of HE. Psychiatrists need to explore for organic etiologies when dealing with acute psychiatric symptoms in a younger age group.

Influence of Helicobacter pylori Infection on Endoscopic Findings of Gastric Adenocarcinoma of the Fundic Gland Type

  • Ishibashi, Fumiaki;Fukushima, Keita;Ito, Takashi;Kobayashi, Konomi;Tanaka, Ryu;Onizuka, Ryoichi
    • Journal of Gastric Cancer
    • /
    • v.19 no.2
    • /
    • pp.225-233
    • /
    • 2019
  • Purpose: Gastric adenocarcinoma of the fundic gland type (chief cell predominant type) (GA-FG-CCP) was first reported as a rare adenocarcinoma found in the normal fundic mucosa. Recent studies have proposed the possibility that GA-FG-CCPs were also generated in the atrophic mucosa after Helicobacter pylori (HP) eradication therapy. However, little is known on the endoscopic findings of GA-FG-CCP generated in the atrophic mucosa due to its extreme rarity. Materials and Methods: A total of 8 patients who underwent endoscopic submucosal resection and were diagnosed with GA-FG-CCP generated in the HP-uninfected mucosa (4 cases, HP-uninfected group) or HP-eradicated atrophic mucosa (4 cases, HP-eradicated group) were retrospectively analyzed, and their endoscopic findings, including magnifying endoscopy with narrow band imaging (M-NBI), and pathological features were compared. Results: While GA-FG-CCPs in the 2 groups displayed similar macroscopic appearance, M-NBI demonstrated that characteristic microvessels (tapered microvessels like withered branches) were specifically identified in the HP-eradicated group. Pathological investigation revealed that a decreasing number of fundic glands and thinned foveolar epithelium covering tumor ducts were thought to lower the thickness of the covering layer over tumor ducts in the HP-eradicated group. Moreover, dilation of vessels just under the surface of the lesions contributed to the visualization of microvessels by M-NBI. Conclusions: The change in background mucosa due to HP infection influenced the thickness of the covering layer over the tumor ducts and M-NBI finding of GA-FG-CCP.

Optimization of Optical Coupling Properties of Active-Passive Butt Joint Structure in InP-Based Ridge Waveguide (InP계 리지 도파로 구조에서 활성층-수동층 버트 조인트의 광결합 효율 최적화 연구)

  • Song, Yeon Su;Myeong, Gi-Hwan;Kim, In;Yu, Joon Sang;Ryu, Sang-Wan
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.47-54
    • /
    • 2020
  • Integration of active and passive waveguides is an essential component of the photonic integrated circuit and its elements. Butt joint is one of the important technologies to accomplish it with significant advantages. However, it suffers from high optical loss at the butt joint junction and need of accurate process control to align both waveguides. In this study, we used beam propagation method to simulate an integrated device composed of a laser diode and spot size converter (SSC). Two SSCs with different mode properties were combined with laser waveguide and optical coupling efficiency was simulated. The SSC with larger near field mode showed lower coupling efficiency, however its far field pattern was narrower and more symmetric. Tapered passive waveguide was utilized for enhancing the coupling efficiency and tolerance of waveguide offset at the butt joint without degrading the far field pattern. With this technique, high optical coupling efficiency of 89.6% with narrow far field divergence angle of 16°×16° was obtained.

Design of Compact Wideband Loop Antenna with Horizontal Slits for Terrestrial DTV and UHD TV Applications (지상파 DTV 및 UHD TV용 수평 슬릿이 추가된 소형 광대역 루프 안테나 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.581-586
    • /
    • 2020
  • In this paper, the design process and method for a compact wideband loop antenna for terrestrial digital TV (DTV) and ultra high definition (UHD) TV applications was proposed. Horizontal slits were added on the two circular sectors of the proposed loop antenna in order to miniaturize the existing wideband loop antenna consisting of a square loop and two circular sectors. A CPW transmission line was inserted in the center of the lower circular sector as a feed line. The CPW feed line was designed using the 75 ohm port impedance for DTV and UHD TV applications, and a tapered center-signal line was designed to improve the impedance matching. The final designed antenna was fabricated on an FR4 substrate with a thickness of 0.8 mm. The experiment results show that the proposed compact loop antenna operates in the frequency band of 444.3-820.1 MHz for a VSWR < 2, which fully covers the DTV and UHD TV bands.

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.5
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

Correlations between abnormalities of morphological details and DNA fragmentation in human sperm

  • Nguyen, Hiep Tuyet Thi;Dang, Hong Nhan Thi;Nguyen, Thai Thanh Thi;Nguyen, Trung Van;Dang, Thuan Cong;Nguyen, Quoc Huy Vu;Le, Minh Tam
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.49 no.1
    • /
    • pp.40-48
    • /
    • 2022
  • Objective: As the associations of sperm DNA fragmentation with morphology have not been examined in detail, this study aimed to investigate the relationship between abnormalities of morphological details and DNA integrity in human sperm. Methods: In this cross-sectional study, men from infertile couples were enrolled at Hue Center for Reproductive Endocrinology and Infertility, Vietnam. Conventional semen parameters, including morphological details, were analyzed following the World Health Organization 2010 criteria. Sperm DNA fragmentation was evaluated using a sperm chromatin dispersion assay. The relationships and correlations between semen parameters, sperm morphology, and the type of halosperm and the DNA fragmentation index (DFI) were analyzed. Results: Among 130 men in infertile couples, statistically significant differences were not found in the sperm halo type between the normal and abnormal sperm morphology groups. The percentage of round-head spermatozoa was higher in the DFI >15% group (16.98%±12.50%) than in the DFI ≤15% group (13.13% ±8.82%), higher values for amorphous heads were found in the DFI >15% group, and lower values for tapered heads were observed in the DFI ≤15% group; however, these differences were not statistically significant. Small-halo sperm and the DFI were positively correlated with round-head sperm (r=0.243, p=0.005 and r=0.197, p=0.025, respectively). Conclusion: The rate of general sperm morphological abnormalities in semen analysis was not related to sperm DNA integrity. However, round sperm heads were closely associated with sperm DNA fragmentation.

Evaluation of Liquefaction Model using Dynamic Centrifuge Test (포화된 경사 사질토 지반의 액상화 수치모델 거동평가)

  • Lee, Jin-Sun;Lee, Sang-Un
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.11
    • /
    • pp.31-42
    • /
    • 2022
  • This study verified numerical analysis of the liquefaction phenomenon using LEAP-2017 international round-robin centrifuge test results. Dynamic centrifuge test is performed by applying a 1 Hz tapered sine wave to the model soil deposit, which was formed under a water table in a surface slope of 5° using Ottawa F-65 sand. A numerical model was made on a prototype scale and analyzed using the finite difference method in 2D and 3D conditions. The analyses were verified for acceleration and pore-water pressure histories with depth and residual displacement. Verification results revealed that all numerical liquefaction models agree reasonably with the test result for acceleration histories but not for pre-water pressure histories. Numerical analyses showed much smaller residual displacement than the centrifuge test. Thus, it is necessary to compare the results of numerical analysis with the centrifuge test performed by other institutes in the future.

Treatment of central diabetes insipidus with anemia in a dog

  • Kim, Sol;Lee, Han Joon;Seo, Kyoung Won;Song, Kun-Ho
    • Korean Journal of Veterinary Service
    • /
    • v.45 no.2
    • /
    • pp.139-143
    • /
    • 2022
  • A 10-year-old, spayed female miniature schnauzer was referred to the Veterinary Medical Teaching Hospital of Chungnam National University due to evaluation of sudden polyuria (PU) and, polydipsia (PD) (540 mL/kg/day) with severe anemia and weight loss. Blood examination results were normal except for severe anemia (hematocrit, [HCT]: 11.8%). Urinalysis revealed a urine specific gravity (USG) of 1.003, whereas urine sediment was not specific. Urine osmolality was 90 mOsm (reference range: 800~2500 mOsm), and plasma osmolality was 303 mOsm. No specific lesions were found using diagnostic imaging including radiography, ultrasonography and magnetic resonance imaging (MRI). The serum cortisol level was normal in cosyntropin stimulation test. Plasma arginine vasopressin (AVP) concentration was <0.4 pg/mL (reference range: 3.49~5.45 pg/mL). Blood transfusion was initiated in addition to an oral prescription of desmopressin acetate (DDAVP, 0.1 mg/head) thrice a day for one week. The patient was rechecked for clinical signs, urine osmolality, and USG; the clinical signs of PU/PD were resolved, urine osmolality increased to 1106 mOsm, and, USG increased to 1.021. Considering the improved clinical signs, and increased urine osmolality, and USG after DDAVP treatment, the dog was diagnosed with central diabetes insipidus. USG and urine osmolality increased to >1.030 and 2200 mOsm, respectively. Anemia also gradually improved and HCT increased to >37%. DDAVP was tapered to 0.1 mg/head twice a day and all clinical signs in the patient have completely resolved.

A Broadband High Gain Planar Vivaldi Antenna for Medical Internet of Things (M-IoT) Healthcare Applications

  • Permanand, Soothar;Hao, Wang;Zaheer Ahmed, Dayo;Falak, Naz;Badar, Muneer;Muhammad, Aamir
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.12
    • /
    • pp.245-251
    • /
    • 2022
  • In this paper, a high gain, broadband planar vivaldi antenna (PVA) by utilizing a broadband stripline feed is developed for wireless communication for IoT systems. The suggested antenna is designed by attaching a tapered-slot construction to a typical vivaldi antenna, which improves the antenna's radiation properties. The PVA is constructed on a low-cost FR4 substrate. The dimensions of the patch are 1.886λ0×1.42λ0×0.026λ0, dielectric constant Ɛr=4.4, and loss tangent δ=0.02. The width of the feed line is reduced to improve the impedance bandwidth of the antenna. The computed reflection coefficient findings show that the suggested antenna has a 46.2% wider relative bandwidth calculated at a 10 dB return loss. At the resonance frequencies of 6.5 GHz, the studied results show an optimal gain of 5.82 dBi and 85% optimal radiation efficiency at the operable band. The optometric analysis of the proposed structure shows that the proposed antenna can achieve wide enough bandwidth at the desired frequency and hence make the designed antenna appropriate to work in satellite communication and medical internet of things (M-IoT) healthcare applications.